Loading...
HomeMy WebLinkAboutWQ0010794_Application (FTSE)_19950322I MEMO TO: State Review Group FROM: Ricky Revels RA" - Environmental Technician IV SUBJECT: Procedure Four (4) WQ0010794 E. Fayetteville/NC 24 Sewer Extension - Public PWC/City of Fayetteville Cumberland County Division of Environmental Management Fayetteville Regional Office 4/27/95 Date State Review Group Review Engineer Buzz Crosby Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: PWC of Fayetteville - Rockfish Creek Wastewater Treatment Plant 2) WWTP design capacity 12.0 MGD 3) NPDES Permit No.: NC0050105 Expiration Date: 5/31/96 4) Compliance Information: Present treatment plant performance for previous 12 months - beginning 3/94 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 486,360 GPD domestic 4% ; industrial 96% ; other 6) Volume from previously approved projects not yet tributary to WWTP 4,913,040 GPD 7) Regional Recommendations: Approval RR/rr Enclosure X Denial }F%2002 17,00,29 TERMINAL CONNECTED TO IM% IM% ;KEX88/MP COMPLIANCE EVALUATION ANALYSIS REPORT 04/26/05 PAGE i PERMIT--NC0050iO5 PIPE--001 REPORT PERIOD: 9483-9502 LOC---E TACILITY--FAYETTEVILLE - PWC ROCKFISH CK DESIGN FLOW-- i2.0000 CLASS--,i -OCATION--FAYETTEVILLE REGION/COUNTY--06 CUMBERLAND 50050 80310 00530 00610 3i6i6 50060 00300 TGP3B 4ONTH Q/MGD BOD RE%/T%% NH3-N FEC COLI CHLORINE DO CERI7DPF WIT F12.0000 F 12.00 F 30.0 F 2.00 F 200.0 NOL NOL NOL R4/03 7.5709 3.7i 1.2 .09 46.2 .363 9.52 WIT Fi2.0000 F 6.00 F i.00 F 200.0 NOL NOL NOL 14/04 7.0600 2.i3 i.O .04 95.9 8.57 i 14/05 6.7483 3.20 i.5 .47 24.7 /4/06 6.8833 2.90 i.2 .04 25.9 9.i8 `4/07 i.i 32.7 8.49 i 14/08 7.5354 4.3i 1.3 .04 18.i 8.93 14/09 7.6O66 i.0 9.5 8.78 /400 7.5096 4.i3 1.6 .09 33.2 30.285 i .IMIT Fi2.0000 F 12.00 F 30.0 F 2.00 F 200.0 NOL NOL NOL 14/ii 7.2066 4.01 i.7 .08 9.2 258.850 9.06 14/12 7.i677 3.93 i.7 .04 8.3 442.050 9^69 15/0i 7.5967 4.83 2.11 i3.2 363.500 9.60 i /5/02 8.i214 4.90 1.8 .04 18.9 388.080 9.73 WRAGE 7.3427 3.74 i.4 .08 27.9 352.721 9.i7 \ iAXIMUM 10.5000 8.50 3.4 2.55 5500.0 760.000 ii.20 i 1INIMUM 6.i000 i.00 .3 .0i LE%%THAN .00 8.00 i /NIT MGD MG/L MG/L MG/L 4/100ML UG/L MG/L PA%%/FAI ;KEX88/MP . COMPLIANCE EVALUATION ANALYSIS REPORT 04/26/95 PAGE 2 PERMIT--NC005005 PIPE--00i REPORT PERIOD: 9403-9502 LOC--- E _ �ACILITY--FAYETTEVILLE - PWC ROCKFISH CK DESIGN FLOW-- 12.0000 CLASS-4 'OCATION--FAYETTEVILLE REGIGN/CGUNTY--06 CUMBERLAND 000i0 00400 00600 00665 0042 0i05i iONTH TEMP PH TOTAL N PHO%-TOT COPPER LEAD .!MIT NOL 9.0 6.0 NOL NOL NOL NOL Q/03 17.47 7.4-6.6 W700 i.5000 .0000 .0000 WIT NOL 9.0 6.0 NOL NOL NOL NOL 24/04 19.60 7.9-7.0 i5.600 1.5600 .00OO .O00O 2i.33 7.7-6.7 i7.800 i.8iO0 .0000 .00O0 /4/06 24.31 8.3-6.9 i3.600 i.6i00 .0000 .000O 14/07 26.00 7.9-6.8 15.500 i.5008 .0000 .00O0 P4/08 26.84 i3.700 i.6200 .0008 .0000 ;4/09 25.85 13.800 i.57OO 2.i000 /400 23.76 i3.i00 i.5300 .0000 .000O .!MIT NOL 9.0 6.0 NOL NOL NOL NOL ?4/ii 22.40 7.4-6.8 13.400 i.8000 .00OO .000O 04/12 20.10 7.5-6.5 i3.500 2.0980 .0000 .00W)i p5/01 i7.65 15.400 i.iBoo .O000 .0000 15/02 i6.55 14.400 i.27OO .0008 .000O AVERAGE 241.82 i4.54i 1.5866 .0008 .i750 iAXIMUM 28.00 8.300 17.800 2.0900 WIMUM 15.00 6.500 i3.iOO i.i800 -------' 2.iO00 ]NIT DEG.0 %U MG/L MG/L UG/L UG/L State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt. Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director March 22, 1995 MR M.J. NOLAND PWC/FAYE I 1 EVILLE PO DRAWER 1089 FAYE I./ EVILLE, NORTH CAROLINA 28302 Dear MR NOLAND: MAR 29 1995 ENV. MANAGEMENT FAYETTEVILLE REG. OFFICE Subject: -Application No. WQ0010794 E. Fayetteville/NC 24 Sewers -Public Cumberland County P-Lt The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on March 20, 1995. This application has been assigned the number listed above. PLEASE REFER TO THE ABOVE WATER QUALITY NUMBER WHEN MAKING INQUIRES ON THIS PROJECT. Your project has been assigned to Buzz Crosby for a detailed engineering review. Should these be any questions concerning your project, the reviewer will contact you with an additional information letter. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project. prior to final action by the Division. If you have any questions, please contact Buzz Crosby at (919) 733-5083 extension 527. If the engineer is unavailable. you may leave a message on their voice mail and they will respond promptly. Please reference the above application number when leaving a message. Si,pcerel y, ICU L• \ (t. .: _> Carolyn Mc askill Supervisor, State Engineering Review Group cc: Fayetteville Regional Office Moorman, Kizer & Reitzel, Inc. Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Tel:phone 919-733-7015 An Equal Opportunity Affirmative Action En;^i)yer �� r✓t_i Y �«J '.. _i-'I i-DEM-WO Ni TS s._ ENGiN. UHi ; " ?tit AmIn: 17 State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management Non -Discharge Permit Application (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) GRAVITY SEWER EXTENSION PUMP STATIONS, AND PRESSURE SEWERS I. GENERAL INFORMATION: 1. Applicant (corporation, individual, or other ): Public Works Comnission of The City of Fayetteville, NC 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): Water Resources M.J. Noland, PE, Director of 3. Mailing Address: PO Drawer 1089 City: Fayetteville State: NC Zip: 28302-1089 Telephone No.: ( 910 ) 483-1401 Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.): East Fayetteville (NC 24) Gravity Sewer and Force Main 5. Application Date: August 17, 1994 7. County where project is located: II. PERMIT INFORMATION: Cumberland Fee Submitted: $ 400.00 1 . Permit No. (will be completed by DEM): 2. Specify whether project is: X new; renewal*; modification. *If renewal, complete only sections I through III and applicant signature (on pg.9). Submit only pgs. 1, 2, 9 (original and 3 copies of each). Engineer signature not required for renewal. 3. If this application is being submitted as a result of a renewal or modification to an existing permit, list the existing permit number and issue date 4. Specify whether the applicant is X public or private. \OQ(0010-194-- FORM: GSPS 4/91 Page 1 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 2 (4/91) III. INFORMATION ON WASTEWATER: Nature of Wastewater: 04 % Domestic; % Commercial, 96 % Industrial; % Other waste (specify): Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: Apparel manufacturing; residential subdivision 3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels: 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? 5. Volume of wastewater generated by this project: 486 , 360 gallons per day 6. Explanation of how wastewater volume was determined: 360 gp_d x 170 1 ots single family dwelling; church 1800 gpd, apparel manufacturing plant 423,360 qpd. IV. DESIGN INFORMATION: 1. Brief project description: Construct 24" sanitary sewer main and 16" force main 2. Name of wastewater treatment facility receiving wastewater Rockfish Creek a, Facility permit no.: NC 0050105 b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: discharges into East Fayetteville 0utfall with excess capacity. 2 of 10 y • • • • GRAVITY SEWER EXTENSION & PUMP STATION PAGE 3 (4/91) 3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C factor or N factor is used and circle C or N below: Dia_ Length Pipe C or N Min. Max. Minimum Max. Minimum (In.) (Lin. Ft) Material Factor Slope % Slope % Velocity (fps) Vel.(fps) Cover (in) 8 30 VCP .013 0.40 0.4 2 8 36 24___ 2589- Cnnc _013 n nR n nR 2 8 36 NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be as follows: a. 36 feet separation for slopes of 21 % to 35%; b. 24 feet separation for slopes of 36% to 50%; c. 16 feet separation for slopes of 50% and greater. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control measures must be specified. For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? 5. Maximum sewer reach length between manholes: 481 linear feet. Sta. Sta. 6. This sewer line segment occurs between manhole no. 11+80 and manhole no. 16+16 7. Does the owner/operator have the ability to clean this length? X Yes No. 8. Sewer subject to existing or planned traffic bearing loads? X Yes No. If yes, what measures are being taken to enable the sewers to withstand the loads? Minimum 3' cover, Class III, IV Concrete Pipe, Class "C" Bedding, Compaction of trench in 8" lifts. 9. Outside drop manholes are provided where invert separations exceed: 2. S feet. 10. Identify (by manhole number) those manholes that have drop connections: N/A 3 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 4 (4/91) Maximum allowable infiltration/exfiltration test rate: Note: Must not exceed XCPD/ pipe dia. in./ mile. 100 100 GPD/ pipe dia. in./ mile 12_ Minimum separation distances as shown on the plans or addressed in the specifications: a) 100 ft. horizontal separation from wells or other water supplies? X Yes No b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? X Yes _ No c) 10 ft horizontal separation from water mains or 18 in. vertical separation (water over sewer) or ferrous pipe specified? 13. Are manholes subject to flooding? 14. If yes, are manhole rim elevations 1 foot above 100-year flood level, (100 year flood elevation should be indicated on plans) 15. Or are manholes watertight and vented 1 foot above the 100-year flood elevation ( should be shown on plans): X Yes No X Yes No X Yes No Yes No 16. Identify (by manhole number) those manholes that are vented: None 17. Does this project involve any stream crossings? yes X no. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: 4 of 10 r • �• GRAVITY SEWER EXTENSION & PUMP STATION PAGE 5 of 10 (4/91) V. PUMP STATION INFORMATION I. Pump Station No.: (A separate sheet V.1 through V.15 should be submitted for each pump station) 2. Name of closest downslope surface waters: 3. Classification of closest downslope surface waters: (as established by the Environmental Management Commission & specified on page 6 of this applic.). 4. If a power failure at this pump station could impact waters classified as WS, SA, B, or SB, describe which of the measures are being implemented to prevent such impact, as required in 15A NCAC 2H .0200: 2nd Source of Power 5. What size pumps are provided? T10; 2200 GPM 6. How many pumps are provided? 2 7. What is the maximum capacity of the pump station? 3,873,600 GPD 8. What is the design total dynamic head? 54.10 feet 9. How many pumping cycles will occur at the design flow rate? 3.7 cycles per hour 10. Check if provided at pump station: Alternate Power Source x Wet Well Vented with Screen x Fillets in Wet Well x Check Valves and Gate Valves x Security Fencing x Lockable Wet Well Cover x Area Light x 110V Electrical Convenience Outlet x Flood/Buoyancy Protection x High Water Alarm x Audible and Visual x Auto Dialer 11. Diameter (Inches) 16 Summary of force main Length Pipe (Linear Ft) Material 7117 DI (by diameter size and pipe material): High Low Minimum Elevation Elevation Velocity(fps) 90 74 2 fps Maximum Minimum Vel.(fps) Cover (in) 8 36 12. Are air release valves provided at all high points along the force main (must be provided where the elevation differencd exceeds 10 feet)? yes X no 13. Is pump station subject to flooding? x yes no. If yes, what measures are being taken to protect against flooding? wet wel 1 top and mechani cal equi pment 11 above 100 year flood. 14. If subject to flooding, specify the 100-year flood elevation: 84.00 Feet MSL 15. Are there existing or planned pump stations downstream of this station? X yes _. no If yes, the engineer shall evaluate the ability of those pump stations to adequately handle the subject flows. GRAVITY SEWER EX 1 ENSION & PUMP STATION PAGE 6 (4/91) TO: REGIONAL WATER QUALITY SUPERVISOR Please provide me with the classification of the surface waters identified in number 5 below and on the attached map segment: Name of surface waters: c L ( C.,P2-e_. Classification (as established by the Environmental Management Commission): Proposed Classification, if applicable: Signature of regional office personnel: I 1` ti A � OCi 2 ``�,, A 0f INSTRUCTIONS TO ENGINEER ENV. A E REG- ()MCCGAYET In order to determine whether provisions for dual or standby power may required for the subject facility, the classification of the closest downslope surface waters (the surface waters that any overflow from the facility would flow toward) must be determined. You are required to submit this form, with items 1 through 10 completed, to the appropriate Division of Environmental Management Regional Water Quality Supervisor (see attached listing). At a minimum, you must include an 8.5" by 11" copy of the portion of a 7.5 minute USGS Topographic Map which shows the subject surface waters. You must identify the location of the facility and the closest downslope surface waters (waters for which you are requesting the classification) on the submitted map copy. The application may not be submitted until this form is completed and included with the submittal. 1. Applicant (corporation, individual, or other ): Publ i c Works Commi ssi on 2. Name and Complete Address of Engineering Firm: Moorman, Kizer & Rei tzel , Inc. 115 Broadfoot Avenue, PO Box 53774 City: Fayetteville State: NC Zip: 28305 Telephone No. (910) 484-5191 3. Project Name: East Fayetteville NC 24 Gravity Sewer & Force Main 4. Pump station design flow: 3,168,000 GPD; 2200 GPM 5. Name of closest downslope surface waters: Locks Creek 6. County(s) where project and surface waters are located: 7. Map name and date: Vander 1956 8. North Carolina Professional Engineer's Registration No. 14951 9- Print Name of Engineer Jeffrey B. Reitzel 10. Seal and Signature (specify date): Cumberl and 6 of 10 - DIVISION OF ENVIRONMENTAL MANAGEMENT REGIONAL OFFICES (4/91) Asheville Regional WQ Super. 59 Wooditn PIAce Asheville, NC 28802 704/251-6208 Avery Macon Buncombe Madison Burke McDowell Caldwell Mitchell Cherokee Polk Clay Rutherford Graham Swain Haywood Transylvania Henderson Yancy Jackson Fayetteville Regional WQ Super. Wachovia Building, Suite 714 Fayeueville, NC 28301 919/486-1541 Anson Moore Bladen Robeson Cumberland Richmond Harnett Sampson Hoke Scotland Montgomery Winston-Salem Regional WQ Super. 8025 North Point Boulevard, Suite 100 Winston-Salem, NC 27106 919/161-2351 Alamance Rockingham Alleghany Randolph Ashe Stokes Caswell Surry Davidson Watauga Davie Wilkes Forsyth Yadkin Guilford Washington Regional WQ Super. P O Box 1507 Washington, NC 27889 919/946-6481 Beaufort Jones Bertie Lenoir Camden Martin Chowan Pamlico Craven Pasquotank Cumtuck Perquimans Dare Pitt Gates Tyrell Greene Washington Hertford Wayne Hyde Mooresville Regional WQ Super. 919 North Main Street Mooresville, NC 28115 704/663-1699 Alexander Cabarrus Catawba Gaston Iredell Lincoln Mecklenburg Rowan Stanly Union Cleveland Raleigh Regional WQ Super. 3800 Barrett Dr., Suite 101 Raleigh, NC 27609 919/733-2314 Chatham Durham FAgecombe Franklin Granville Halifax Johnston Lee Nash Northampton Orange Person Vance Wake Warren Wilson Wilmington Region. WQ Super. 127 Cardinal Drive Extension Wilmington, NC 28405-3845 919/395-3900 Brunswick Carteret Columbus Duplin New Hanover Onslow Pender 7 of 10 i GRAVITY SEWER EXTENSION & PUMP STATION PAGE 8 (4/91) THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required hems a. One original and three copies of the completed and appropriately executed application form. b. Three sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, details on the pump station, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the first page of the specifications must be signed and sealed. Three copies of the existing permit if a renewal or modification. c. Three copies of all calculations, including pump selection, fraction calculations, cycle time, pump curves (including system curves applicable with one pump running, two pumps running, three pumps running, etc.), and evaluation of downstream pump stations. These items must be submitted under the signature and seal of the North Carolina Professional Engineer. d. The appropriate permit processing fee, in accordance with 15A NCAC 2H 0205(c)(5). e. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents. a homeowners association, or a developer 8 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 9 (4/91) Name and Complete Address of Engineering Firm: Moorman, Kizer & Rei tzel , Inc. Engineers, Planners & Surveyors City: Fayettevi 1 l e State: NC Zip: 28305 Telephone No. (910) 484- 5191 Professional Engineer's Certification: 1, Jeffrey B. Rei tzel , attest that this application for East Fayetteville (NC 24) Gravity Sewer & Force Main has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. . North Carolina Professional Engineer's Registration No. 14951 Print Name of Engineer Jeffrey B. Rei tzel Seal and Signature (specify date) Applicant's Certification: 1, M.J. Noland, PE , attest that this application for East Fayettevi l l e (NC 24) Gravity Sewer & Force Main Ott L 60EBEE SEAL o � _ ..,, 14951 € t%:3NtimEt0/ d40888Q17ss9e 0, has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. Signature l4/ Date /U - 26 T OMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: 919/733-5083 9 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 10 (4/91) PERMIT APPLICATION PROCESSING FEES (effective October 1, 1990) CATEGORY jsIEW APPLICATIONS/ RENEWALS WITHOUT MODIFICATIONS MODIFICATIONS > 1,000,000 GPD Industrial $400 $300 Domestic/Cooling Water $400 $300 10,001 - 1,000,000 GPD Industrial $400 Domestic/Cooling Water $400 $250 $250 1,001 - 10,000 GPD Industrial $400 $200 Domestic/Cooling Water $400 $200 < or = 1,000 GPD and Single Family Dwelling Sludge < or = 300 Acres Sludge > 300 Acres oft $240 $120 $400 $400 $250 $250 Sewer Extensions (nondelegated) $400 0 Sewer Extensions (delegated) $200 0 Closed -Loop Recycle or Evaporative $400 $200 NOTE: The Fees for Soil Remediation Projects are the same as for Sludges. Under the Sewer Extension Fee, "delegated to municipalities" applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the Division of Environmental Management. 10 of 10 4. State of North Carolina Department of Environment. Health, and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh. North Carolin:: 2 -(,2(,-tl; ,` G_ur_. i . Ever::a. !III) James G. Martin, Governor \Vill.am W. Cobey, Jr.. Sec:tary Memorandum To: Delegated Municipalities From: Steve W. Tedder. Chief. (` . Water Quality Section Suo,ect: Delegated Munic:p,i! t:es for Revised [.on -Disc dr•'e P ernu ppllc [i ;1:; The Division of Environmental Management's Water Quality Section has revised the Gravity Sewer Non -Discharge Permit Application Form. The form now incorporates the basil information that the Division feels is necessary in order for the delegated municipalities to perform review on a gravity sewer project for the Division; therefore, the Division will no longer require that the "Delegated Municipalities Gravity Sewer Design Checklist" be completed and submitted. We do. however, require that the delegated municipality perform the same type of review as always required and complete the bottom portion of this page and attach it as the last page of a!1 gravity sewer applications that are being submitted as a delegated municipalities project. If you have any questions on this matter, please contact Mr. Randy Jones at 919/133-5083. DELEGATED MUNICIPALITY GRAVITY SEWER CF,RTIFIC ATTO (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) May 1, 1991 Applicant: pURI.TC WOnYS Q)MMTSSTON GF THE Project Name: EAST FAYETTEVILLE (NC 24) GRAVITY SEWER & FORCE MAIN Delegated Municipality Reviewer's Certification: I, VICTOR GAN.IEHSANT , attest that the subject plans and specifications have been reviewed under my supervision and that those plans and specifications are consistent with the information that has been specified on the Non -Discharge Application and the. Division of Environmental Management's minimum design requirements for gravity sewer projects. Delegated Municipality Reviewer's NC Professional Engineer's Registration No.: Seal and Signature (specify date): FORM: DMGS 4/91 PAGE 1 OF 1 's p� nIJQ: N CARO/7 to 1 V N '' z -' .SSIO� • :� v E. iei' SEA1- � v�9S1AL 14368 i ( �C',Fj�GI N�F.� ��, �iT, G AN `c�, A!?::udu5A 5 5 MI_ ob • • RI FORT BRAGG r; MI. (FAY ETTEV'LLE) , I '-OQI . "u `\ \` eii \�, • State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director April 10, 1995 M.J. Noland, P.E. Director of Water Resources Public Works Commission of the City of Fayetteville Post Office Drawer 1089 Fayetteville, North Carolina 28302-1089 Dear Mr. Noland: Afir3511 1=3 591BIAF3 APR 1.7 1)95 ENV. MANAGEMENT FAYETTEVILLE REG. OFFICE Subject: Project Return (WQ0010794) Public Works Commission of the City of Fayetteville NC 24 Sewer Extension Cumberland County This letter is being sent in reference to the subject project and your application for a permit, which was received on March 20, 1995. Pursuant to North Carolina General Statute 150B-14, the Department of Environment, Health, and Natural Resources has establish conditions which require an environmental assessment for certain projects. Specifically, the condition which requires an environmental assessment for the subject project is for a pump station with a capacity in excess of 1.0 MGD. The Division has received the 13 copies of the Environmental Assessment and has forwarded them to Monica Swihart, Water Quality SEPA Coordinator, for processing. The Environmental Assessment must be reviewed by the Department, sent through State Clearinghouse review, and a statement of "Finding of No Significant Impact (FONSI)" issued. This review period may take approximately 4 to 5 months. This FONSI must be included in the permit application package prior to a permit action by the Division of Environmental Management. Therefore, the Division must return the application package as incomplete until the environmental assessment review is completed and a FONSI is issued. In addition, any significant comments and/or requirements, which may develop during the review of the environmental documents, regarding the proposed design must be addressed and finalized before re -submitting the sewer application package to the Division for review. , The Division is forwarding your permit application, application processing fee, and all supporting materials under separate cover. If you have any questions concerning this matter, please contact Buzz Crosby at 919/733-5083. Sincerely, Ocuu3k,k, A Presto cc: Permit File WQ0010794 Fayetteville Regional Office Moorman Kizer and Reitzel, Inc. Howard, Jr'., P.E. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper 1