HomeMy WebLinkAboutSW1210503_Plansheet - C2.0 (Proposed Site)_202107301412.00 PROJECT DESCRIPTION - PROJECT ENTRANCE THE PURPOSE OF THIS PROJECT IS TO INSTALL A MICROGRID LAT: 35.888357 '11, k CONSISTING OF 4.4 MW14.4 MWH BATTERY ENERGY STORAGE Jo SYSTEM AND A 1.96 MWac SOLAR PV SYSTEM. THE INSTALLATION F 10I LONG: -82.827317 16'WIDE SITE ACCESS ROAD R41 0 ONSIST OF FIXED STRUCTURES WITH MOUNTED PHOTOVOLTAICS. PER 02/C5.0 7 3.3 ACRES WILL BE DISTURBED DURING THE CONSTRUCTION 1416 PERIOD. THE LIMITS OF CONSTRUCTION AREA IS 15.8 ACRES LENGTH = 548' R25.0 LOCATED IN MADISON COUNTY. BUA = NOT APPLICABLE PER < 1420.05 A-4 FOR ROADS USED LESS �216.0 THAN OR EQUAL TO TWICE A MONTH. R200.0 NCDOTT YPE 4 CONCRETE BARRIER PER 03/C5.2 R25.0 R41.0� 142 .02 �j 52.4' LEASE LINE Zt TO FENCE 4%* k 0111 GROUNDING TRANSFORMER VEGETATIVE SCREENING %* SEE INSET - 2 14 R200.0 (SEE SHEET C3.2) SOUTH RN RAILWAY THIS SHEET MV SWITCHGEAR �rls 200'R/W( RP.B.3,PG.15) TEMPORARY 24" RCP R LENGTH = 40' n, 24'ACCESS GATE BESS TRANSWITCHER PER 05/C5.2 PER 01/C5.2 R25.0 11111iL SITE CONTROL TEMPORARY ACCESS PER 02/C5.0 BUILDING BUA 216 SF A"k 0." , 1,2"1111 #57 STONE AREA = 10615 S f 11P DEPTH 4 INCHES BESS INVERTER #1 AND #2 VEGETATIVE SCREENING BUA = 1623 SF (IMPERVIOUS OIL CONTAINMENT AREA) 'D (SEE SHEET C3.2) 711,38 2111 /* 1, x j'r 141 GRIDSOLV BATTERY �j 1 36 CONTAINER #1 AND #2 P7 LEASE LINE BUA = 700 SF TO FENCE AUXILIARY PANEL AND BESSTRANSFORMER TRANSWITCHER PAD PEDESTRIAN GATE BUA 100 SF\�� EQUIPMENT PAD FOR PV SWITCHBOARD AND PV TRANSFORMER /'BUA 684 SF (IMPERVIOUS OIL CONTAINMENT AREA) SEEINSET-1 THIS SHEET ZU.U' ul�-�-Zljtz I �-KUIVI lop- LEASE LINE, TYP. PROPOSED WOODS LINE PV PANEL, TYP.�-, CEMETERY TRACK 1415 1116 142'0 TRENCHING 14,35 INVERTER GROUP, TYP. 20.6' 1440 46 12. 1' 144,9 '0I 41p EXISTING JIL G 441v 41p 1495 4kp SX- 1416.00 77.20 7.1 4jV 4#r 1500 21.4' 24.1 SX- 4ir 5.0 20.0' 1420.05 ?9-3 PERIMETER FENCE 505 S/,-- At 4w LENGTH = 3,595' NCDOTTYPE4 41, 4kp PER 02/C5.2 CONCRETE BARRIER, TYP. 4kp 17 \Sll�- 4kp ft, 5.1 5.0 .1' 142 A 4W 27.4 40 11 MI, 6.9 15� d 9.11 6.1 19.01 IS m 011 2.6 76' 15.0' /120.0 ,�!24000 IN, 266 15.0' 26.5' Ilk 26.9 01 Z.0 1424.02 0 30' 60' 14% 0 30' 60' A PEDESTRIAN GATE 100.0 1,540 INSET INSET - 2 PROJECT LEGEND EXISTING PROPOSED TOP OF BANK PV EQUIPMENT PAD ADJOINER LINE BATTERY CONTAINER PROPERTY LINE INVERTER OVERHEAD POWER TRANSFORMER/AUX. PAD CURB & GUTTER . ......................................................................... MV SWITCHGEAR RIGHT OF WAY CONTROL ROOM EASEMENT LINE PV PANEL SANITARY SEWER TRENCHING STORM DRAINAGE INVERTER GROUP ...... GAS LINE VEGETATIVE SCREENING WATER LINE LIMITS OF CONSTRUCTION UNDERGROUND ELECTRIC SECURITY FENCE -0- UNDERGROUND CABLE SITE ACCESS ROAD WOODS LINE RAILROAD MAJOR CONTOUR -100 MINOR CONTOUR LEASE LINE WOODED AREA TO -BE -REMOVED CONCRETE PROPOSED WOODS LINE ASPHALT FLOODWAY 100-YR FLOOD 500-YR FLOOD MAJOR CONTOUR 100 MINOR CONTOUR GUY WIRE UTILITY POLE TREE STUMP WATER SUPPLY 0 60' 120' Know what's below. Call before you dig. CIVIL DESIGN r '/6- SEI Engineering "�Z, lk'tl' ErIgir)LenngaWoI�d F�om?red bySolarltnelgy SEI PROFESSIONAL SERVICES 39845 MATHEWS LANE PAONIA, CO 81428 INFO@SEISOLARPROS.COM 970.527.3920 ENGINEER EPC CONTRACTOR wATZTSILA WARTSILA NORTH AMERICA, INC 11710 N. GESSNER ROAD, SUITE A HOUSTON, TX 77064 (571) 325-6481 DUKE PROJECT NUMBER 446-14 DUKE SHEET NUMBER HSPOO-SI-C-PL-03 Q 0 0 Z 0 3Z W D Z CO W -qT > r-- < 00 C14 C) Z W - 0� W 0 (D Z Z < U) U 0 W 0 00 V- CLIENT 000UNITED"' 101 REI,d"'OIABLE ENE R'G Y UNITED RENEWABLE ENERGY 5895 SHILOH RD STE 104 ALPHARETTA, GA 30005 (Ij Z ILL] 0 �E U) u) �E 0) Z 0 L 1i Lij C) C) < Ljj 06 5: Z 0 b 0 a_ a- < C) �E U-] < U-] a- U) cl� W < U-] Uj U) 0 0 U) 0 U-] c) < (D W co 0) 00 < (D (D (14 C) Lo IT r-- (D C3 C:) W CO 'T 12� PHASE IFC REV3 DATE 2/10/21 AS SHOWN NOTE If this drawing is not 24x36" it has been revised from its original size the scales noted on drawing/details are no longer applicable. DRAWN BY DRAWN BY REB I DRAWING NAME PROPOSED SITE PLAN C2.0