Loading...
HomeMy WebLinkAboutNCS000548_2021 DMR_20210715; 4� DUKE Ir ENERGY® July 15, 2021 DUKE ENERGY CORPORATION Marshall Steam Station 8320 East NC Highway 150 Terrell, NC 28682 NC Dept. of Environmental Quality Attention: Central Files Division of Water Resources 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: Duke Energy Carolinas, LLC NPDES Stormwater Discharge Monitoring Report for: Marshall Steam Station - NCS000548 — Catawba County Year 1 Period 2 monitoring Dear Sir or Madam: In accordance with Part E-2. of the above referenced NPDES Stormwater permit, the original and one copy of the Stormwater Discharge Outfall (SDO) monitoring reports containing results of the Tier II monthly sampling is attached. Representative samples were collected from stormwater outfalls SW002, SW003, SW007, SW008, SW011, SW012, SW022 and SW025 on June 7, 2021. The attached summary of corresponding analytical results indicate that three outfalls are reported with targeted constituents above corresponding permit benchmarks. These include the following: • SWO02 (Mercury, 12.1 ng/L) • SWO03 (total suspended solids, 130 mg/L; Copper, 0.0139 mg/L; and Mercury, 13.5 ng/L) • SWO07 (Zinc, 0.151 mg/1) In response to the benchmark exceedances, Tier 1 inspections were performed at these outfalls on June 29, 2021. A Tier 1 status email notification was submitted to the agency on June 30, 2021, Feasible corrective actions were identified in the Tier 1 reports and are currently in the process of being implemented at the facility. As directed to the agency, outfall SWO12A was abandoned in 2020 and the grade was adjusted to allow for sheet flow of stormwater in this area. To date, outfall SW026 has not been constructed. Please direct any correspondence or questions concerning the Marshall Steam Station NPDES Stormwater Program to Scott La Sala (828-478-7820) or Don Safrit at (919) 546-6146. Sincerely, Rick R. "Roper General Manager III Marshall Steam Station attachment www.duke-energy.com cc w/attachment: James Moore, MRO be w/attachment: Scott La Sala Don Safrit r"__ rrM r1 Ir r•If . Ll.r- r-n.3 UPS Tracking Number 1Z8955X40399668801 Raleigh Central Office 1Z8955X40399128411 James Moore, MRO DUKE ENERGY CORPORATION Marshall Steam Station 8320 East NC Highway 150 Terrell, NC 28682 www.duke-energy.com Permit Number NCS000548 FACILITY NAME PERSON COLLECTING SAMPLE(S) CERTIFIED LABORATORY(S) Part A: Specific Monitoring Requirements STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Marshall Steam Station J Scott La Sala Duke Energy Pace Huntersville Office Shealy Environmental Services, Inc. SAMPLES COLLECTED DURING CALENDAR YEAR: 2021 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) Lab # 248 Lab # 530 Lab # 329 COUNTY PHONE NO Catawba (904) 631-8042 SIGNATURE OF PERMITTEE OR DESIGNEE REQUIRED ON PAGE 12338 Outfall No. Date Sample Collected 00400 01077 01002 01022 01012 01027 01034 01042 Total Rainfall pH Silver, Total (as Ag) Arsenic, Total (as As) Boron, Total (as B) Beryllium, Total (as Be) Cadmium, Total (as Cd) Chromium, Total (as Cr) Copper, Total (as Cu) mo/dd/ r inches unit m /L m /L m /L m /L m /L m /L m /L SW002 6/7/2021 0.59 7.2 <0.0003 0.00133 <0.05 <0.001 <0.001 0.00254 0.00323 SW003 6/7/2021 0.59 7.8 <0.0003 0.00376 <0.05 <0.001 <0.001 0.00775 0.0139 SW007 6/7/2021 0.59 7.2 <0.0003 <0.001 <0.05 <0.001 <0.001 <0.001 0.00648 SW008 6/7/2021 0.59 17.4 SWO11 6/7/2021 0.59 17.0 1 1 1 1 1<0.001 <0.001 SW012 6/7/2021 0.59 17.6 SW012A --- outfall permanently abandonded SW022 6/7/2021 0.59 17.4 SW025 6/7/2021 0.59 17.5 SW026 --- outfall not yet constructed Outfall No. Date Sample Collected 01067 01051 01097 01147 01059 01092 71900 CO530 00556 Nickel, Total (as Ni) Lead, Total (as Pb) Antimony, Total (as Sb) Selenium, Total (as Se) Thallium, Total (as Ti) Zinc, Total (as Zn) Mercury, Total Method 1631 E Solids, Total Suspended - Concentration Oil & Grease mo/dd/ r m /L m /L m /L m /L m /L m /L n /L m /L m /L SW002 6/7/2021 <0.001 0.00146 <0.001 <0.001 <0.0002 0.057 12.1 35 SW003 6/7/2021 0.00263 0.00625 <0.001 0.0022 0.000257 0.059 13.5 130 SW007 6/7/2021 <0.001 <0.001 <0.001 <0.001 <0.0002 0.151 5.20 8.9 <4.9 SW008 6/7/2021 1 1 1 7.9 SWO11 6/7/2021 <0.001 1 10.036 1 7.2 SW012 6/7/2021 19 SW012A 6/7/2021 outfall abandonded SW022 6/7/2021 17.4 SW025 6/7/2021 139 SW026 6/7/2021 outfall not yet constructed Benchmark exceedances include Zinc, Total (as Zn) at SW007 Benchmark exceedances include Solids, Total Suspended - Concentration and Copper, Total (as Cu) and Mercury, Total Method 1631 E at SW003 Benchmark exceedances include Mercury, Total Method 1631 E at SW002 Form SWU-247, last revised 4/1/2021 Permit Number NCS000548 Page 1 of 1 Does this facility pertorm Vehicle Maintenance Activities using more than 55 gallons of new motor oil per months yes (it yes, complete Part B) Part B: Vehicle Maintenance Activity Monitoring Requirements STORM EVENT CHARACTERISTICS: Mail Original and one copy to: Date 06/07/2021 Division of Water Quality Total Event Precipitation (inches): 0.59 Attm Central Files Event Duration (hours): (only if applicable see permit.) 1617 Mail Service Center Raleigh, North Carolina 77699 1617 (if more than one storm event was sampled) Date Total Event Precipitation (inches): Event Duration (hours): (only if applicable— see permit.) "1 certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. 1 am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (iFoti R:dk i Date) no Form SWU-247, last revised 4/1/2021 Permit Number NC5000549 Page 2 of 2 UPS CampusShip: View/Print Label 1. Ensure there are no other shipping or tracking labels attached to your package. Select the Print button on the print dialog box that appears. Note: If your browser does not support this function select Print from the File menu to print the label. 2. Fold the printed label at the solid line below. Place the label in a UPS Shipping Pouch. If you do not have a pouch, affix the folded label using clear plastic shipping tape over the entire label. 3. GETTING YOUR SHIPMENT TO UPS Customers with a Daily Pickup Your driver will pickup your shipment(s) as usual. Customers without a Daily Pickup Take your package to any location of The UPS Store®, UPS Access Point(TM) location, UPS Drop Box, UPS Customer Center, Staples® or Authorized Shipping Outlet near you. Items sent via UPS Return Services(SM) (including via Ground are also accepted at Drop Boxes. Tu Gilu the location aarcctyo tease visit than Rp-mirnes area of CampusShip and select UPS Locations. Schedule a same day or future day Pickup to have a UPS driver pickup all your CampusShip packages. Hand the package to any UPS driver in your area. UPS Access PointTM UPS Access Polntn" UPS Access Point" ADVANCE AUTO PARTS STORE 6631 MICHAELS STORE # 3710 CVS STORE # 3803 696 RIVER HWY 590 RIVER HWY 559 RIVER HWY MOORESVILLE ,NC 28117 MOORESVILLE ,NC 28117 MOORESVILLE ,NC 28117 FOLD HERE W- uL 0 a m o' rA a J W0 Zce=)� LuLu0d% ZZW°� W 0UW O J ZUFW-N rj a V to f 0 LL.Ly LL oN M 03O/ v�go�N 2Z�UI-d ndOLLJ�J JZ Ln ItLQz� w 1gy ~71 OOOK Ln000m 001— N O Q1 N V — O•i �r �rFCi`y 0 00 tp o X Do N Z c O W o �1s° Lnu IL QU�N�0 or' J VI N ED tY t}a