HomeMy WebLinkAboutWQ0041633_Application_20210727DWR Division of Water Resources RECEIVED/NCDEQ/DWR JUL 2 7 2021 State of North Carolina Department of Environmental Quality WQROS Division of Water Resources MOORESVILLE REGIONAL OFFICE 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION O Application Number: kk)(2(� C) 91633,o be "14completed DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: The Charlotte Mecklenburg Hospital Authority (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal 3. Signature authority's name: Tom Washington per 15A NCAC 02T .0106(b) Title: Director 4. Applicant's mailing address: 9401 Arrowpoint Blvd., Office 306 City: Charlotte State: NC Zip: 28273-8166 5. Applicant's contact information: Phone number: (704) 667-9428 Email Address: Tom.WashingtonAatriumhealth.org ❑ Other II. PROJECT INFORMATION: 1. Project name: Atrium Union West - Private 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ0041633 and issued date: 12/15/2020 If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Union 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.083° Longitude: -80.667° 5. Parcel ID (if applicable): 071-020-23A (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Corey W. M. King License Number: 048981 Firm: Kimley-Hom and Associates, Inc. Mailing address: 200 South Tryon Street, Suite 200 City: Charlotte State: NC Zip: 28202-0095 Phone number: (704) 954-7477 Email Address: corey.king(ciikimley-horn.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Crooked Creek WRF Permit Number: NC0069841 Owner Name: Union County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0001158 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Union County FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ZN/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) 0 Residential Leased ❑ Retail with food preparation/service 0 School / preschool / day care ® Medical / dental / veterinary facilities ® Food and drink facilities ❑ Church ❑ Businesses / offices / factories 0 Nursing Home 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) ❑ Car Wash ❑ Hotel and/or Motels 0 Swimming Pool /Clubhouse 0 Swimming Pool/Filter Backwash Z Other (Explain in Attachment) >Is there a Pretreatment Program in effect? ® Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ® No )=. If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow Hospitals, medical 300 gal/Bed 0 GPD Central Energy Plant 8,760 gal/Building 0 GPD Medical Office 250 gal/Practitioner-Shifts 0 GPD gal/ GPD gal/ GPD gal/ GPD Total 0 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ® Flow has already been allocated in Permit Number: WQ0041633 O Rehabilitation or replacement of existing sewer with no new flow expected O Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 6" -1,089 PVC 6" -182 DIP 8" -149 PVC 8" 1 DIP 12" 36 DIP > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: . Longitude: - ° 3. Design flow of the pump station: 4. Operational point(s) of the pump(s): millions gallons per day (firm capacity) gallons per minute at 5. Summarize the force main to be permitted (for this Pump Station): feet total dynamic head (TDH) Size (inches) Length (feet) Material 6. Power reliability in accordance with 15ANCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches > 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. > **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage > If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N/A > This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? > Information can be obtained from the 401 & Buffer Permitting Branch ❑ Yes ® No 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes No ❑ N/A > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 DocuSign Envelope ID: 35AB5E2E-7517-4A98-8944-3DAE82B9E36B X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ®Yes ❑No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I, Corey W. M. King (Professional Engineer's name from Application Item III.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Toni Washington, Director �ocISignesEAl { e r 03448 y • • 13QO 74194FD..„reel *Zj' W� i�{ /„1C�3/2021 8alilIl 5 (Signature Authority's name & title from Application Item L3.) attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. DocuSigned by: Signature: ` I Date: 7/26/2021 CF75A9AD530543E... FORM: FTA 04-16 Page 5 of 5 Kimley>»Horn July 26, 2021 NCDEQ Mooresville Regional Office 610 E. Center Avenue Mooresville, NC 28115 RECEIVED/NCDEQ/DWR JUL 2 7 2021 WQROS MOORESVILLE REGIONAL OFFICE Subject: Fast Track Sewer System Extension Permit Modification Application Existing Permit No. WQ0041633 - Private Atrium Union West 1459 Stallings Rd Stallings, NC 28104 To Whom it May Concern, Submitted is the fast track sewer system extension application for the modification of Existing Permit No. WQ0041633 dated December 15, 2020 for the Atrium Union West hospital and associated development located in Stallings, NC for your review and approval. The modification to the existing permit includes changes to the sanitary sewer lengths based on as -built conditions and due to the removal of sanitary sewer laterals from the NCDEQ Fast Track Sewer System Extension Permit. The existing permit included a total of approximately 1,163 LF of 6" PVC, 182 LF of 6" DIP, 488 LF of 8" PVC, 1,218 LF of 8" DIP, and 13 LF of 12" DIP private sanitary sewer pipe designed to serve a 200- bed hospital, a 40 practitioner -shift medical office building, and a central energy plant. The modification requested for this permit includes the subtraction of 107 LF of 6" PVC, 17 LF of 6" DI, and 124 LF of 8" PVC as well as the addition of 1 LF of 8" DIP and 36 LF of 12" DIP private sanitary sewer pipe based on as -built conditions. An additional subtraction of 982 LF of 6" PVC, 165 LF of 6" DIP, and 25 LF of 8" PVC is requested for the removal of sanitary sewer laterals from the NCDEQ Fast Track Sewer System Extension Permit. This results in a net subtraction of 1,089 LF of 6" PVC, 182 LF of 6" DI, and 149 LF of 8" PVC and net addition of 1 LF of 8" DIP and 36 LF of 12" DIP private sanitary sewer pipe to the existing permit. The included application is for a net total of approximately 74 LF of 6" PVC, 0 LF of 6" DIP, 339 LF of 8" PVC, 1,219 LF of 8" DIP, and 36 LF of 12" DIP private sanitary sewer pipe designed to serve a 200- bed hospital, a 40 practitioner -shift medical office building, and a central energy plant. As in the existing permit, these buildings will be serviced by a proposed 8" public sanitary sewer which discharges to an existing 8" public sanitary sewer. Although the nature of all wastewater flows is classified as domestic/commercial, Union County is requiring a private grinder station as pre- treatment. These changes are summarized in the chart on the following page. �r .. o 2000 South Boulevard, Suite 440, Charlotte, NC 28203 704 333 5131. Kimley»>Horn Page 2 Type Description Permit No. WQ0041633 Quantity Removal of Laterals Correction for As-Builts Total Change Net Amount Length (FT) 6" PVC 1,163 -982 -107 -1,089 74 Length (FT) 6" DIP 182 -165 -17 -182 0 Length (FT) 8" PVC 488 -25 -124 -149 339 Length (FT) 8" DIP 1,218 0 1 1 1,219 Length (FT) 12" DIP 13 0 36 36 49 This package includes the following: • $480 Application Fee • NCDEQ Fast Track Sewer System Extension Application (FTA 04-16), including o Design flows per 15A NCAC 02T .0114(c) • Flow Tracking/ Acceptance Form (FTSE 04-16) (Signed copy on file) • Site Maps • Existing Permit No. WQ0041633 • Onsite Water and Sewer Asbuilt Plans Should you have any questions or comments, please do not hesitate to contact me by phone or by e- mail at 704-954-7477 or corey.king@kimley-horn.com. Sincerely, KIMLEY-HORN AND ASSOCIATES, INC. Corey King, PE Project Engineer Enclosure le horn.co 2000 South Boulevard, Suite 440, Charlotte, NC 28203 704 333 5131 Atrium Union West — Aerial Vicinity Map Hospital Site Proposed Private Sanitary Sewer Proposed Public Sanitary Sewer Tie -In Location #Wg001158 i+a>irttiy Forest Park Lift Station :l.IQV+1:9. >31owj), ^`.fintar 0,:r•:!'yr.teOt'c-11, 97 tJ.5c .8,;lameMD, len, INiY3c31.0 i�0t4ir Atrium Union West — Topo Quad Map Proposed Public Sanitary Sewer 'Proposed Private Sanitary Sewer Tie -In Location I4W Q001158