HomeMy WebLinkAboutNCG100110_Outfalls Update_20210629McCoy, Suzanne
From:
Brandon Walsh <bswalsh@LKQCORP.com>
Sent:
Tuesday, June 29, 2021 5:45 PM
To:
McCoy, Suzanne
Subject:
[External] Outdated information for outfalls at NCG100110
Attachments:
1143 Map.pdf
Follow Up Flag:
Follow up
Flag Status:
Flagged
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to
Report Spam.
Ms. McCoy,
I was referencing the stormwater permit summary report for the LKQfacility in Lagrange to set up the eDMR application,
and noticed that the outfalls listed seem to be outdated. There are 5 outfalls and they all discharge to an unnamed
tributary then to Whitelace Creek. The attached map has geographic coordinates for each outfall. Is there any other
information you need to correct this issue? Thank you for your time!
-Brandon S. Walsh, CPISM, CPSWQ
Environmental Compliance Manager
LKQ Corp.
5846 Crossings Blvd.
Antioch, TN; 37013
O: (615) 988-3371
C: (615) 477-9833
F: (855) 286-7954
e: bswalsh@lkgcorp.com
Link: LKQ's Safetv. Health & Environmental Web Site
Please remember to practice social distancing and limit gatherings to ten people or fewer
when conducting safety meetings, training, or department safety briefs.
1
STORM WATER DRAINAGE TOTAL: / \ \7
ACRES-25 /+
\ NORTH
IMPERVIOUS- 60
OUTFALL 001 1 X 550-GALLON DIESEL FUEL AST /+ SCALE
ACRES -1 1 X 250-GALLON USED OIL AST \ \
IMPERVIOUS-25% (IN SECONDARY CONTAINMENT)
OUTFALL 002 + \
ACRES-8
IMPERVIOUS-25% 25G-GALLON USED OIL +/MECH PAPo(` \ \
OUTFALL 003-1 AST (DOUBLE -WALLED +/ SHOP
IMPERVIOUS
OUTFALL004 OD -GALLON WASTEWATER AST
ACRES-1 WASH WATER • CE
IMPERVIOUS-25
OUTFALL005 RECYCLE FOR PRESSURE g SAS \
ACRES-13 SHEET METAL W AREA COUNTER
IMPERVIOUS-60% NEW ENGINE O \
/ ARI}IOUSE STORAGE • �" \ \ \ \
OUTFALL 002 SIC CODE 5015 �+ • • �SHIPPI AREA
3516'12.22'N • ` • �� LARGE TRUCKS \ \ \ \
3516'12.22'N `1
DISCHARGES TO UNNAMED / • p$�G • DOVERFLOW
\ \
1RIBWFITELACE THEN INTOCREEK �+ • • g1 • RADIATORS�- > \ \
FLUID STORAGE BUILDING: +/ /. • • CORES �� • / \� 4.000-GALLON \ \
1 X 500-GALLON GASOLINE AST \ • / �� + DIESEL FUEL AST
1 500-GALLON WASTE GASOLINE AST }/(DOUBLE WALLED)+ >• �\ • • : / ��` (DOUBLE -WALLED)
1 X Soo -GALLON USED OIL AST VEHICLE
/•
% +
1 X 200-GALLON USED OIL AST / ( HOLDING .6 i ��. • . / VEHICLE � AREA 4 / � • HOLDING
+/ 16 / �� • • AREA INSIDE DISMANTLING
�� j ( �� • �� �� 1 X 275-GALLON USED OIL AST
�� / )1 • ♦ OUTSIDE DISMANTING (DOUBLE -WALLED
/ VEHICLE ���• • �� 1 2 X 275-GALLON USED OIL / 4 X 55-GALLON USED OIL DRUM
HOLDING / • ♦� ( AST (DOUBLE -WALLED)
� AREA � ^ • • �� /i
• / / • �� ( • SIC 5015
/ • �J / • • • \ • 35' 16' 5.41'
• y �� -7T 44'-25.94'
lj • �� VEHICLE DISCHARGES TO UNNAMED TRIBUTARY THEN INTO
CRUSHING • ( • �� STORAGE I WHITELACE CREEK
AREA •
11 • � AREA •
� • OUTFALL 004
_ • • • • �� •� • SIC 5015
35' 16' 4.45'
I • • • • \\\��\ // DISCHARGE'S TO UNNAMED TRBUTARY THEN INTO
/ • • �v / WHITELACE CREEK
/ VEHICLE / • • OUTFALL 001
STORAGE j � • • SIC 5015
I ! AREA ! / 35' 16' 3.32'
-77' 44'-26.52'
DISCHARGES TO UNNAMED TRIBUTARY THEN INTO
/ ( ! ! I I •� \ WHITELACE CREEK
WHITELACE CREEK DISCHARGES INTO
\ \ \ I ( I THE NEUSE RIVER ESTUARY (APPROVED
\ \ \\ L I VEHICLE I TMDL FOR TOTAL NITROGEN)
\ \ \ I I STORAGE I
\\ VEHICLE \ I AREA
\ STORAGE \\ \\\\
\ AREA \
DRNNAGE \\ \\ \ I L 1
I L
SCALE IN FEET DITCH
0 57.5 115 230
DRAINAGE
LEGEND PIPES 1 1 1 1 OUTFALL 005
SITE BOUNDARY SIC
5015 �.
— x— x— FENCE LINE OURS -7T 44'-26.3'
• • • *DRAINAGE BOUNDARY DISCHARGES TO UNNAMED TRIBUTARY THEN INTO
NHITELACE CREEK
^a DIRECTION OF SURFACE RUN-OFF DESCRIPTION: DRAWN: FIGURE:2
UNDERGROUND CORRUGATED PIPES JB SITE LAYOUT AND DRAINAGE MAP
DRAINAGE DITCH - - - - - - CONCRETE PIPING LKQ EAST CAROLINA#1143 SCALE:
7135 US HIGHWAY 70 EAST GRAPHIC
UNDERGROUND PIPING LAGRANGE, SC 29334 W
Q• STORM WATER OUTFALL 3/6/19 LLr+