HomeMy WebLinkAboutNCG200513_ROS Request_20210728Division of Energy, Mineral & Land Resources Stormwater Program , National Pollutant Discharge Elimination System Environmental REPRESENTATIVE OUTFALL STATUS (ROS) nunuty FOR AGENCY USE ONLY Date Received Year Month Day If a facility is required to sample multiple discharge locations with very similar Stormwater discharges, the permittee may petition the Director for Representative Outfall Status (ROS). DEQ may grant Representative Outfall Status if stormwater discharges from a single outfall are representative of discharges from multiple outfalls. Approved ROS will reduce the number of outfalls where analytical sampling requirements apply. If Representative Outfall Status is granted, ALL outfalls are still subject to the Qualitative monitoring requirements of the facility's permit —unless otherwise allowed by the permit (such as NCG020000) and DEQ approval. The approval letter from DEQ must be kept on site with the facility's Stormwater Pollution Prevention Plan. The facility must notify DEQ in writing if any changes affect representative status. For questions, please contact the DEQ Regional Office for your area (see page 3). (Please print or type) 1) Enter the permit number to which this ROS request applies: Individual Permit (or) Certificate of Coverage N C S N I C I G 2 0 0 15 11 13 2) Facility Information: Owner/Facility Name United Scrap Metal NC, LLC Facility Contact John Dergo Street Address 9925 Brookford Street City Charlotte State NC ZIP Code 28273 County Mecklenburg E-mail Address ldergo@unitedscrap.com Telephone No. 704 587-2701 Fax: 3) List the representative outfall(s) information (attach additional sheets if necessary): Outfall(s) 2 is representative of Outfall(s) 1 & 2 Outfalls' drainage areas have the same or similar activities? Outfalls' drainage areas contain the same or similar materials? Outfalls have similar monitoring results? XYes ❑ No XYes ❑ No X Yes ❑ No ❑ No data* Outfall(s) 3 is representative of Outfall(s) 3 & a Outfalls' drainage areas have the same or similar activities? XYes Outfalls' drainage areas contain the same or similar materials? D(Yes Outfalls have similar monitoring results? XYes Outfall(s) is representative of Outfall(s) Outfalls' drainage areas have the same or similar activities? Outfalls' drainage areas contain the same or similar materials? Outfalls have similar monitoring results? ❑ No ❑ No ❑ No ❑ No data* ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ No data* *Non-compliance with analytical monitoring prior to this request may prevent ROS approval. Specific circumstances will be considered by the Regional Office responsible for review. Page 1 of 3 SWU-ROS-2009 Last revised 12/30/2009 Representative Outfall Status Request 4) Detailed explanation about why the outfalls above should be granted Representative Status: (Or, attach a letter or narrative to discuss this information.) For example, describe how activities and/or materials are similar. Outfalls 1 & 2 and 3 & 4 have similar industrial activities exposed to stormwater Outfalls 1 & 2 - Both drain covers with fibrous filters. Outfall 2 also has petrol storage tanks. Outfalls 3 & 4 - Both outfalls outfitted with a stormwater control measure (regenerative storm conveyance system) in the drainage swale to mitigate the impact of TSS in the stormwater runoff. Outfall 3 has open flow prior to the roadway drainage ditch which makes it a better option for sampling. 5) Certification: North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). 1 hereby request Representative Outfall Status for my NPDES Permit. I understand that ALL outfalls are still subject to the qualitative monitoring requirements of the permit, unless otherwise allowed by the permit and regional office approval. I must notify DEQ in writing if any changes to the facility or its operations take place after ROS is granted that may affect this status. If ROS no longer applies, I understand I must resume monitoring of all outfalls as specified in my NPDES permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: John Dergo Title: General Manager _ Of 6/11/2021 (Date Signed) Please note: This application for Representative Outfall Status is subject to approval by the NCDEQ Regional Office. The Regional Office may inspect your facility for compliance with the conditions of the permit prior to that approval. Final Checklist for ROS Request This application should include the following items: ❑ This completed form. ❑ Letter or narrative elaborating on the reasons why specified outfalls should be granted representative status, unless all information can be included in Question 4. ❑ Two (2) copies of a site map of the facility with the location of all outfalls clearly marked, including the drainage areas, industrial activities, and raw materials/finished products within each drainage area. ❑ Summary of results from monitoring conducted at the outfalls listed in Question 3. ❑ Any other supporting documentation. Page 2 of 3 SWU-ROS-2009 Last revised 12/30/2009 Representative Ouftll Status Request Mail the entire package to: NCDEQ DEMLR at the appropriate Regional Office (See map and addresses below) Notes The submission of this document does not guarantee Representative Outfall Status (ROS) will be granted as requested. Analytical monitoring as per your current permit must be continued, at all outfalls, until viritten approval of this request is granted by DEQ. Non-compliance with analytical monitoring prior to this request may prevent ROS approval. Specific circumstances will be considered by the Regional Office responsibie for review. For questions, please congac� the ®EQ Regional Office for your area. Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Washington Regional Office Phone (828) 296-4500 943 Washington Square Mall Washington, NC 27889 FAX (828) 299-7043 Phone (252) 946-6481 Fayettevilie Regional Office FAX (252) 975-3716 Systel Building, 225 Green St., Suite 714 Wilmington Regional Office Fayetteville, NC 28301-5094 127 Cardinal Drive Extension Phone (910) 433-3300 Wilmington, NC 28405 FAX 910/ 486-0707 Phone (910) 796-7215 M®oresvillce Regional Office FAX (910) 350-2004 610 East Center Ave. Winston-SMem Regional Office Mooresville, NC 28115 585 Waughtown Street Phone (704) 663-1699 Winston-Salem, NC 27107 Phone (336) 771-5000 FAX (704) 663-6040 Water Quality Main FAX (336) 771-4630 RMeigh Regional Office Central Office 1628 Mail Service Center Raleigh, NC 27699-1628 1612 Mail Service Center Raleigh, NC 27699-1612 Phone (919) 791-4200 FAX (919) 571-4718 Phone (919) 807-6300 FAX (919) 807-6494 Page 3 of 3 SWU-ROS-2009 Last revised 12/30/2009 n n ❑UTFALL 004 ❑UTFALL 003 Total Site Area = 9,94 Acres (Includes areas w/ no industrial activity) Drainage Area 1 (DA1) Drainage Area 2 (DA2), Drainage Area 3 (DA3), Drainage Area 4 (DA4)l Total Area, 3,5 acres Total Areas 0.3 acres Total Areas 1,1 acres Total Areas 2.4 acres Impervious Areas 2,7 acres Impervious Areas 0.27 acres Impervious Areas 0,37 acres Impervious Area, 0,60 acres BR❑❑KF❑RD ST 773,29' SCALES ASPHALT ROAD >> > »> > > >i > >>> > >>> > »> a a DA 4 n n LO GRASS ¢ w ? wj GRASS FW W ^ ^ NCL Ua U a CL �CM ^ n a ^ ^ ti a GRASS GRASS CL SCM ASPHALT ROAD SHELTER D A 2 GRASS SHEET RUN-OFF FIGURE 2: Site Drainage & Potential Pollutant Source Map United Scrap Metal, Inc. 9925 Brookfiord Street Charlotte, NC 28273 MAINTENANCE SK AREA 0-GAL \POLY TANKS F&CL CABINET SK ❑FFICE 32' X 50' DA 1 BUILDING 215,67' x 421.5' <90903,5 SF) ASPHALT PKG LOT n '� D A 1 AIR L❑CK 40' N AIR GRASS DA 3 MAKEUP a UNITS a > w \ oN TOTE(S) & �' C 80-GAL POLY BAILER D A 1 / TANKS ® S/R SK F&CL CABINET SK S/R F- S D O EMPTY R❑LPL-OFF BINS AB ii SHEET RUN-OFF 11 GRASS I Is GRASS ❑UTFALL 002 742,16' SCALE 0' LEAF ENVIRONMENTAL & ENGINEERING, P.C. 1 426 E. NC HWY 54, 5TE C DURHAM, NO 27713 200' ❑UTFALL 001 KEY A N❑N-HIGHWAY ULTRA L❑W SULFUR DIESEL FUEL TANK (1500-GAL) B HIGHWAY ULTRA L❑W SULFUR DIESEL FUEL TANK (2000-GAL) C FUEL TANKER PARKING AREA D L❑CATI❑N ❑F EMERGENCY ST❑P SWITCH AND FUEL PUMP DISC❑NNECTS ❑T TRANSF❑RMER ® CATCH BASIN SW RUNOFF FLOW DIRECTI❑N �D TRASH DUMPSTER DA DRAINAGE AREA S/R SHIPPING/RECEIVING GRASS LINED DRAINAGE CHANNEL F&CL FLAMMABLE & C❑MBUSTIBLE LIQUIDS SCM ST❑RM W ATER C❑NTR❑L MEASURE SK SPILL KIT UNDERGROUND STORM DRAIN PIPE PROJECT NO.: 239016 DATE: January, 2021 DRAWN BY: KJK APPROVED BY: TWM FILE: United Scrap Metal/Stormwater DRAINAGE AREA BOUNDARY PR❑PERTY BOUNDARY (FULLY FENCED) RAILR❑AD TRACKS SCALE: AS SHOWN