Loading...
HomeMy WebLinkAboutNCG030394_Monitoring (Report)_20210723a] I �& -0 1 July 2021 Mr. James Moore NCDEQ Division of Energy, Mineral, and Land Resources Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 Subject: Report of Stormwater Sampling— First Half 2021 Commercial Fabricators, Inc. 2045 Industrial Drive Newton, Catawba County, North Carolina NCDEQ Certificate of Coverage #NCG030394 Dear Mr. Moore: Attached is a stormwater sampling report for the subject facility. If you have any questions regarding this submittal, please contact the undersigned at 336-382-6849. Sincerely, Jeff Gerlock, L.G. NC Licensed Geologist #1141 Attachments — SW Discharge Monitoring Report Form Cc: Mr. John R. Tucker, Jr, Commercial Fabricators Operations Excellence, Inc., 2235-E Lewisville-Clemmons Road, Clemmons, North Carolina 27012— 336-766-2913 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for N00030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office Certificate of Coverage No. NCG03® Person Collecting Samples: Jeff Gerlock Facility Name: Commercial Fabricators Laboratory Name: Meritech Facility County: Guilford Laboratory Cert. No.: 165 Discharge during this period: ❑ Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions for any benchmark exceedances? ❑ Yes ❑ No If so, which Tier (I, 11, or III)? II Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall 1 Outfall 2 Outfall Outfall Outfall Code N/A Receiving Stream Class C C N/A Date Sample Collected MM/DD/YYYY 06/07/2021 06/07/2021 46529 24-Hour Rainfall in inches 1.7 1.7 00552 Non -Polar Oil & Grease in mg/L (15) <5 10 C0530 TSS in mg/L (100 or 50*) 4 <2.5 00400 pH in standard units (6.0-9.0) 6.13 6.67 New Motor/Hydraulic Oil Usage in NCOIL gal/month 01119 Copper, total recoverable in mg/L 0.003 0.008 (0.010 FW, 0.005 SW) 01051 Lead, total recoverable in mg/ L <0.0 1 0 <0.0 1 0 (0.075 FW, 0.220 SW) Zinc, total recoverable in mg/ L (0.126 0.079 0.213 01094 FW, 0.095 SW) 78141 Total Toxic Organics (TTO) in mg/L(1) NA NA * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L. Notes (optional): I "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permittee or DeVgated Authorized Individual 7 z ® zo21 Date