Loading...
HomeMy WebLinkAbout20211154 Ver 1_ePCN Application_20210726DWR mrlslon of Water Resources Pre -Construction Notification (PCN) Form For Nationwide Permits and Regional General Permits (along with corresponding Water Quality Certifications) June 1, 2021 Ver4.1 Initial Review Has this project met the requirements for acceptance in to the review process?* r Yes r No Is this project a public transportation project?* r Yes r No Change only if needed. BIMS # Assigned 20211154 Is a payment required for this project?* r No payment required r Fee received r Fee needed - send electronic notification Reviewing Office* Mooresville Regional Office - (704) 663-1699 'Information for Initial Review la. Name of project: 506 W. Tremont Avenue la. Who is the Primary Contact?* Kelly Roth 1b. Primary Contact Email:* roth@mcadamsco.com Date Submitted 7/26/2021 Nearest Body of Water Irwin Creek Basin Catawba Water Classification C Site Coordinates Latitude: Longitude: 35.211769-80.869598 A. Processing Information County (or Counties) where the project is located: Mecklenburg Is this a NCDMS Project r Yes r No Is this project a public transportation project?* r Yes r No Pre -Filing Meeting Information Version#* 1 What amout is owed?* IT $240.00 r $570.00 Select Project Reviewer* Alan Johnson:eads\adjohnson1 1c. Primary Contact Phone:* (919)287-0716 Is this a courtesy copy notification?* r Yes r No ID# Version Pre -fling Meeting or Request Date 5/12/2021 Attach documentation of Pre -Filing Meeting Request here: nick the upload button or drag and drop files here to attach document 01-RWR20000-Tremont-Pre-filing request-2021-05-12.pdf File type mast be FCF 1a. Type(s) of approval sought from the Corps: V Section 404 Permit (wetlands, streams and waters, Clean Water Act) r Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) Has this PCN previously been submitted?* r Yes r No 1b. What type(s) of permit(s) do you wish to seek authorization? W Nationwide Permit (NWP) r Regional General Permit (RGP) r Standard (IP) 1c. Has the NWP or GP number been verified by the Corps? r Yes r No Nationwide Permit (NWP) Number: NWP Numbers (for multiple NWPS): 1d. Type(s) of approval sought from the DWR: fJ 401 Water Quality Certification - Regular r Non-404 Jurisdictional General Permit r Individual 401 Water Quality Certification 29 - Residential Developments le. Is this notification solely for the record because written approval is not required? For the record only for DWR401 Certification: For the record only for Corps Permit: 793.8KB r 401 Water Quality Certification - E>q)ress r Riparian Buffer Authorization 1f. Is this an after -the -fact permit application?* r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No 1h. Is the project located in any of NC's twenty coastal counties? r Yes r No 1j. Is the project located in a designated trout watershed? r Yes r No B. Applicant Information 1d. Who is applying for the permit? r Owner fJ Applicant (other than owner) le. Is there an Agent/Consultant for this project?* r Yes r No 2. Owner Information 2a. Name(s) on recorded deed: SC7, LLC c/o DMI 2b. Deed book and page no.: DB 34281; PG 664 2c.Contact Person: Ivan D. Rohrer, III r Yes r No r Yes r No 2d.Address Street Address 5950 Fairview Road Address Une 2 Ste 525 City Charlotte Postal / Zip Code 28210 2e. Telephone Number: (704)343-0056 2g. Email Address:* idriii@dmi-nc.com 3. Applicant Information (if different from owner) 3a. Name: Matthew Beck 3b. Business Name: RangeWater Real Estate 3c.Address Street Address 5605 Glenridge Drive, NE Address Line 2 Ste 775 City Atlanta Postal / Zip (ode 30342 3d. Telephone Number: (202)288-8022 3f. Email Address:* mbeck@liverangewater.com 4. Agent/Consultant (if applicable) 4a. Name: Kelly Roth 4b. Business Name: McAdams 4c.Address Street Address 2905 Meridian Parkway Address Une 2 CRY Durham Postal / Zip Code 27713 4d. Telephone Number: (919)287-0716 4f. Email Address:* roth@mcadamsco.com C. Project Information and Prior Project History 1. Project Information 1b. Subdivision name: (d appropriate) NA 1c. Nearest municipality/ town Charlotte State / Province / ftim NC Country USA 2f. Fax Number: State / Province / Pegim GA Country USA 3e. Fax Number: State / Province / Piegim NC Country USA 4e. Fax Number: Project Identification 2a. Property Identification Number: 11906427 2b. Property size: 3.5 2c. Project Address Street Address 536 W Tremont Ave Address tine 2 CKY Charlotte Postal / Zip Code 3. Surface Waters 3a. Name of the nearest body of water to proposed project:* Irvin Creek 3b. Water Resources Classification of nearest receiving water:* C 3c. What river basin(s) is your project located in?* Catawba 3d. Please provide the 12-digit HUC in which the project is located. 030501030101 4. Project Description and History State / province / Region NC Country USA 4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application:* The project area has been used for an auto salvage yard and landfill in the past and is a Brownfield site. Successional mixed hardwood/pine has grown up on approximately one-half of the project area. The remaining areas have herbaceous vegetation and some remaining bare areas. Land use in the vicinity of the project consists of industrial, commercial, single- family residences and multi -family developments. Figure 1 depicts the location of the project area on the US Geological Survey (USGS) Charlotte East, NC 7.5-minute quadrangle topographic map. Figure 2 show the location of the project area on the Web Soil Survey map. Figure 3 depicts the subject property on an aerial photograph of the area. 4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?* r Yes r No r Unknown 4f. List the total estimated acreage of all existing wetlands on the property: 0 4g. List the total estimated linear feet of all existing streams on the property: 242 4h. Explain the purpose of the proposed project:* The purpose of the project is to construct a multi -family development to serve the current and future residents of Charlotte. 4i. Describe the overall project in detail, including indirect impacts and the type of equipment to be used:* The project is a 5-story, multi -family residential development With approximately 300 units. The development consists of some retail space, necessary infrastructure, and residential amenities including a parking garage, stormwater control measures, pool courtyard area, and an open space area to be developed by others. The attached Impact Coordination Map depicts the proposed project and impacts to jurisdictional and non -jurisdictional areas. As part of the project, W. Tremont Avenue must be widening, which Will impact a perennial stream channel that begins at a culvert under the road. A non -jurisdictional and DWR isolated wetland will be filled (0.08 ac) to create open space to be used for outdoor recreation. This impact is covered by the State General Permit for Impacts to Isolated and Other Non-404 Jurisdictional Wetlands and Surface Waters (Permit Number IWGP100000). 5. Jurisdictional Determinations 5a. Have the wetlands or streams been delineated on the property or proposed impact areas?* r Yes r No Comments: An AJD request has been submitted but has not been issued. 5b. If the Corps made a jurisdictional determination, what type of determination was made?* r Preliminary r Approved r Not Verified r Unknown r N/A Corps AID Number: Not assigned 5c. If 5a is yes, who delineated the jurisdictional areas? Name (if known): Jennifer Burdette Agency/Consultant Company: McAdams Other: 6. Future Project Plans r Unknown 6a. Is this a phased project?* r Yes r No Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity? D. Proposed Impacts Inventory 1. Impacts Summary 1a. Where are the impacts associated with your project? (check all that apply): r Wetlands W Streams -tributaries F Buffers r Open Waters r Pond Construction 3. Stream Impacts 3a. Reason for impact (?) 3b.lmpact type * 3c. Type of impact* 3d. S. name* 3e. Stream Type * 3f. Type of 3g. S. width* 3h. Impact ❑ (?) 11 Jurisdiction" length* S1 Road WideningPermanent Culvert UT to Irwin Creek Perennial Both 8 17 Average (feet) (linearfeet) 3Y Road Widening -No Loss Permanent Rip Rap Fill UT to Irwin Creek Perennial Both 5 32 Average (feet) (lir�rfeet) S3 Road Widening Temporary Other UT to Irwin Creek Perennial Both Average (feet) (lir�rfeet) � SW Outlet Protection Permanent Fill JUT to Irwin Creek Perennial Both 8 6 Average (feet) (linearfeet) 31. Total jurisdictional ditch impact in square feet: 0 31. Total permanent stream impacts: 55 31. Total stream and ditch impacts: 64 31. Total temporary stream impacts: 9 3j. Comments: Temporary impacts to the stream downstream of the riprap are necessary for construction access. Pre -construction contours will be restored after the installation of the culvert extension and riprap. E. Impact Justification and Mitigation 1. Avoidance and Minimization 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project: Because widening of W. Tremont Avenue is required, impact to the stream is unavoidable. This stream is deeply incised with actively eroding banks. The proposed riprap dissipator will dissipate the energy from this wasting stormwater discharge. Impact to the remaining stream will be avoided except for riprap on the streambank below the stormwater outlet to protect it against future erosion. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques: The riprap dissipator Will be buried in the streambed to maintain the stream channel dimensions. A Sediment and Erosion Control Plan for the project will be developed and approved by the City of Charlotte and the project will comply with the supplementary NPDES Construction Stormwater Permit (NCG010000). 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? r Yes r No 2c. If yes, mitigation is required by (check all that apply): f DWR W Corps 2d. If yes, which mitigation option(s) will be used for this project? r Mitigation bank W Payment to in -lieu fee r Permittee Responsible program Mitigation 4. Complete if Making a Payment to In -lieu Fee Program 4a. Approval letter from in -lieu fee program is attached. r Yes r No 4b. Stream mitigation requested: (linear feet) 4c. If using stream mitigation, what is the stream temperature: 17 warm 4d. Buffer mitigation requested (DWR only): (square feet) 4e. Riparian wetland mitigation requested: (acres) 4f. Non -riparian wetland mitigation requested: (acres) 4h. Comments 4g. Coastal (tidal) wetland mitigation requested: (acres) it is our understanding from previous projects that stream and wetland mitigation is required for any amount of impact in the Charlotte watershed. The attached NCSAM assessment indicates the stream is of low quality. Therefore, we propose stream mitigation at a 1.5:1 ratio, which is doubled to account for mitigation that is only available in the expanded service area, for a total of 51 stream credits required. F. Stormwater Management and Diffuse Flow Plan (required by DWR) 1. Diffuse Flow Plan 1a. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? r Yes r No If no, explain why: There is no State riparian buffer on the site. 2. Stormwater Management Plan 2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250?* r Yes r No 2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)? r Yes r No 2c. Does this project have a stormwater management plan (SMP) reviewed and approved under a state stormwater program or state -approved local government stormwater program? r Yes r WA - project disturbs < 1 acre 3. Stormwater Requirements r No 3a. Select whether a completed stormwater management plan (SMP) is included for review and approval or if calculations are provided to document the project will not cause degradation of downstream surface waters.* r Stormwater Management r Antidegradation Plan Calculations Comments: This project is subject to the City of Charlottes's Post Construction Stormwater Ordinance (PCSO). The project is located in a Distressed Business District within the City of Charlotte. This project is meeting the requirements of the ordinance by providing volume reduction in the one year storm, and flowrate reduction (detention) in the two-year, ten-year, and 25-year storm events. These reductions are comparing the post -project to pre -project volumes and flow rates computed on the site, and should prevent future flooding and degradation of the receiving channel by controlling velocities in the channel during these design storm events. The existing property has a variety of existing gravel and old paved surfaces, as the site was a previous junk yard for vehicles. There are no stormwater controls present on site to control the existing impervious surface. The proposed storm water controls ignore the existing impervious surfaces on -site, and analyze the stormwater from a 50 % open, 50 % wooded baseline (pre -development) condition. This results in the computed pre -project target flowrate (and velocity) being less than the actual pre -project flowrate (and velocity). That said, the runoff from the proposed condition should be improved over the existing conditions. Point of analysis results are listed on the impact map. U G. Supplementary Information :�; I 1. Environmental Documentation 1a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?* r Yes r No 2. Violations (DWR Requirement) 2a. Is the site in violation of DWR Water Quality Certification Rules (15ANCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or Riparian Buffer Rules (15A NCAC 2B .0200)? * r Yes f• No 3. Cumulative Impacts (DWR Requirement) 3a. Will this project result in additional development, which could impact nearby downstream water quality?* r Yes r No 3b. If you answered "no," provide a short narrative description. The proposed project is an apartment complex that is not anticipated to result in additional development. 4. Sewage Disposal (DWR Requirement) 4a. Is sewage disposal required by DWR forth is project?* r Yes r Nor WA 4b. Describe, in detail, the treatment methods and dispositions (non -discharge or discharge) of wastewater generated from the proposed project. If the wastewater will be treated at a treatment plant, list the capacity available at that plant. The project will be connected to the City of Charlotte's sanitary sewer system. 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or habitat?* r Yes r No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts?* r Yes f No 5c. If yes, indicate the USFWS Field Office you have contacted. Asheville 5d. Is another Federal agency involved?* r Yes r No r Unknown 5e. Is this a DOT project located within Division's 1-8? r Yes r No 5f. Will you cut any trees in order to conduct the work in waters of the U.S.? r Yes r No 5g. Does this project involve bridge maintenance or removal? r Yes r No 5h. Does this project involve the construction/installation of a wind turbine(s)?' r Yes r No 51. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.? r Yes r No 5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? McAdams used USFWS IPaC Information for Planning and Consultation Tool to obtain the attached official species list. The attached May Affect Verification letter from USFWS indicates the project is consistent with activities analyzed in the PBO. The project area contains suitable habitat for Michau)es sumac, smooth coneflower, and Schweinitits sunflower. A survey will be completed as soon as smooth coneflower and Schweinitits sunflower are observable closer to the optimal survey windowfor these species and within the windowfor Michaux's sumac. The perennial stream channel is of low quality and not suitable habitat for Carolina heelsplitter. A complete protected species assessment will be prepared and submitted to USFWS after the plant surveys are completed. 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as an Essential Fish Habitat?* r Yes r No 6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?* The Essential Fish Habitat (EFH) Mapper (https://www.habitat.noaa.gov/protection/efh/efhmapper) was accessed on June 16, 2021. 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?* r Yes r No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources?* According to HPOWEB 2.0, the project is located adjacent to the Wilmore Local Historic District 2010 (MK3252). An environmental review request was submitted on June 17, 2021. SHPO's response Will be provided upon receipt. 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA-designated 100-year floodplain?* r Yes r No 8c. What source(s) did you use to make the floodplain determination?* FIRM Map Number 3710454300L, effective 9/2/2015 Miscellaneous Please use the space below to attach all required documentation or any additional information you feel is helpful for application review. Documents should be combined into one file when possible, with a Cover Letter, Table of Contents, and a Cover Sheet for each Section preferred. Qick the upload button or drag and drop files here to attach docunent 03-Tremont PCN Attachments.pdf 6.76MB File crust be FDF or ME Comments Signature ® By checking the box and signing below, I certify that: • The project proponent hereby certifies that all information contained herein is true, accurate, and complete to the best of my knowledge and belief; and The project proponent hereby requests that the certifying authority review and take action on this CWA 401 certification request within the applicable reasonable period of time. • I have given true, accurate, and complete information on this form; • I agree that submission of this PCN form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND I intend to electronically sign and submit the PCN form. Full Name: Kelly Roth Signature Date 7/26/2021 ROY COOPER Governor JOHN NICHOLSON Interim Secretary TIM BAUMGARTNER Director Matthew Beck RangeWater Real Estate 5605 Glenridge Dr, Ste 775 Atlanta, GA 30342 Project: 536 W Tremont Avenue NORTH CAROLINA Environmental Quality June 15, 2021 Expiration of Acceptance: 12/15/2021 County: Mecklenburg The purpose of this letter is to notify you that the NCDEQ Division of Mitigation Services (DMS) is willing to accept payment for compensatory mitigation for impacts associated with the above referenced project as indicated in the table below. Please note that this decision does not assure that participation in the DMS in -lieu fee mitigation program will be approved by the permit issuing agencies as mitigation for project impacts. It is the responsibility of the applicant to contact permitting agencies to determine if payment to the DMS will be approved. You must also comply with all other state, federal or local government permits, regulations or authorizations associated with the proposed activity including G.S. § 143-214.11. This acceptance is valid for six months from the date of this letter and is not transferable. If we have not received a copy of the issued 404 Permit/401 Certification within this time frame, this acceptance will expire. It is the applicant's responsibility to send copies of the permits to DMS. Once DMS receives a copy of the permit(s) an invoice will be issued based on the required mitigation in that permit and payment must be made prior to conducting the authorized work. The amount of the in -lieu fee to be paid by an applicant is calculated based upon the Fee Schedule and policies listed on the DMS website. Based on the information supplied by you in your request to use the DMS, the impacts for which you are requesting compensatory mitigation credit are summarized in the following table. The amount of mitigation required and assigned to DMS for this impact is determined by permitting agencies and may exceed the impact amounts shown below. River Basin Impact Location 8-di it HUC Impact Type Impact Quantity Catawba 03050103 Warm Stream 20 *DMS proposes to utilize the Catawba 03 Expanded Service Area to meet the mitigation requirement. Upon receipt of payment, DMS will take responsibility for providing the compensatory mitigation. The mitigation will be performed in accordance with the In -Lieu Fee Program instrument dated July 28, 2010. Thank you for your interest in the DMS in -lieu fee mitigation program. If you have any questions or need additional information, please contact Kelly.Williams@ncdenr.gov. Sincerely, FOR James. B Stanfill Asset Management Supervisor cc: Jennifer Burdette, agent D EQ �� North Carolina Department of Environmental Quality Division of Mitigation Services 217 West Jones Street 1 1652 Mail Service Center I Raleigh, North Carolina 27699-1652 NORTH CAROLINA oePanmem or enmrommemai ouai� / 919.707.8976 536 W. Tremont List of Application Attachments Property Owner Certification Agent Authorization Form Figure 1. USGS Topographic 7.5-Minute Quadrangle Figure 2A. Web Soil Survey Map Figure 3. Aerial Map Figure 4. Approved Jurisdictional Determination Request Map EX -A. Impact Coordination Map Property Owner Certification Project Name: W Tremont Project Manager: Brandon Plunkett/ Jennifer Burdette Property Owner Certification Information Parcel Information Street Address: S36 W Tremont Avenue City, State: Charlotte, North Carolina County: Mecklenburg Parcel Index Number(s) (PIN): 11906427 Property Owner Information Name: SC7 LLC c/o DMI Title (if applicable):c�-, Mailing Address: 5950 Fairview Road, Ste 525 Charlotte, NC 28210 Telephone Number. — Electronic Mail Address: 0% Property Access Certification By signing below, I authorize representatives of the Wilmington District, U.S. Army Corps of Engineers (Corps) to enter upon the property herein described for the purpose of conducting on -site investigation, if necessary, and issuing a jurisdictional determination pursuant to Section 404 of the Clean Water Act and/or Section 10 of the Rivers and Harbors Act of 1899. I, the Undersigned, am either a duly authorized owner of record of the property identified herein or acting as the duly authorized agent of the owner of record of the property.* kc Print Name Capacity: ® Owner D Authorized Agent Date T Signature �c) �1@ Project Number: RWR-20000 Agent Authorization Form J MCADAMS AGENT AUTHORIZATION FORM All Blanks To Be Filled In By The Current Contract Purchaser PIN (s): 11906427 Name: RangeWater Real Estate- POC: Matthew Beck Address: 5605 Glenridge Drive NE, Suite 775 Atlanta, Georgia 30342 Phone: 202-288-8022 Email: mbeck@liverangewater.com Project Name: W Tremont Project Number: RWR-20000 Project Manager: Brandon Plunkett/Jennifer Burdette US Army Corps of Engineers — Wilmington District Asheville Regulatory Field Office 151 Patton Avenue, Room 208 Asheville, NC 28801-5006 Re: Wetlands Related Consulting and Permitting To Whom It May Concern: NC Division of Water Resources 401 & Buffer Permitting Branch 512 N. Salisbury Street Raleigh, NC 27604 I hereby designate and authorize The John R. McAdams Company, Inc. to act on my behalf as my agent in obtaining verification of wetland delineations and processing of permit applications for the project listed above. I, the undersigned, a duly authorized owner of record of the property/properties identified herein, do authorize representatives of the Wilmington District, U.S. Army Corps of Engineers (Corps) and NC Division of Water Resources to enter upon the property herein described for the purpose of conducting on -site investigation and issuing a determination associated with Waters of the U.S. subject to Federal jurisdiction under Section 404 of the Clean Water Act/Section 10 of the Rivers and Harbors Act of 1899 and/or Waters of State and/or Riparian Buffer Rules. This notification supersedes any previous correspondence concerning the agent for this project. NOTICE: This authorization, for liability and professional courtesy reasons, is valid only for government officials to enter the property when accompanied by The John R. McAdams Company, Inc. staff. Matthew Beck Aj ,- Print Contractor Purchaser Name *Signature Manager, Development 7.21.21 Title (if applicable) *Date creating experiences through experience 2905 Meridian Parkway, Durham, NC / 919. 361. 5000 Figure 1. USGS 7.5-minute Topographic Map wiiz 1. USGS; 7.5 MINUTE, QUADS CHARLOTTE EAST, NORTH CAROLINA; 2019 LAT: 35.211769, LONG:-80.869598 a 49� 0k'' ggmf •,yam. �� E� t 27 49 SSiI 0 1,000 2,000 FIGURE 1. USGS TOPOGRAPHIC MAP Feet 536 W TREMONT 1 inch = 2,000 feet CHARLOTTE, MECKLENBURG COUNTY, NC VERSION: 1 DATE: 6/1 /2021 McADAMS JOB NO: RWR-20000 DRAWN BY: pierzga Figure 2A. Web Soil Survey Map Unit Symbol Map Unit Name Hydric CuB Cecil -Urban land complex, 2 to 8 percent slopes No CuD Cecil -Urban land comDlex. 8 to 15 oercent slopes No ir < •fj ii �. �t �7�5 t Ate' ` ��• ^ J. � ) �`_.. .__ � a 44 it .47 Imo' ,),� TREMONTAV .111,0111119 _ �,,�► ►��'�� `tom ..N ,-. Legend )� Project Area Soil Map Unit �„ 20�11/r1N,CCGIA. N)C9 B.. )d Soil Survey SSURGO Spatial Data: Mecklenburg County (Version 6, Sep 16, 2019) 0 50 100 J FIGURE 2. NRCS WEB SOIL SURVEY Feet 536 W TREMONT 1 inch =100 feet CHARLOTTE, MECKLENBURG COUNTY, NC VERSION: 1 DATE: 6/1 /2021 McADAMS JOB NO: RWR-20000 DRAWN BY: pierzga Figure 3. Aerial Map Figure 4. Approved Jurisdictional Determination Map a 0 PROJECT AREA a b ' L End TREMONT LEGEND Project Area Wetlands 50-ft Post -Construction Buffers — — Streams Streets 2-ft Contours ��r�cciu� o Q 4,--,CD CD a Waters of the U.S. ° Stream Feature A- (a)(2) Perennial Tributary +/-` 421FF� fed-Wetland— W1 -(b)(1)� +/- 0.086 ac P a�a 0 50 100 Feet FIGURE 4. APPROVED JURISDICTIONAL DETERMINATION MAP 536 W TREMONT 1 inch = 100 feet VERSION: 1 CHARLOTTE, MECKLENBURG COUNTY, NC DATE: 6/15/2021 MCADAMS JOB NO: RWR-20000 DRAWN BY: manning M:\Projects\RangeWater\RWR-20000\04-Production\Natural Resources\GIS\RWR20000-Tremont-Fiq 4AJD Map.mxd, 6/15/2021 8:52:41 AM, manning EX -A. Impact Coordination Map Z a a z a sozsz vnlnoavO H18olu'3>l018vH:) ;3 z Q s - 3nN3AViNOW3di'M9£S S9NIMVW] Noii:)ndiSNOJ p m z $ Y 3nN3AV 1NOW3Hl 'M 9£S o G W^W ---- L�-� -�--- - - - , 1 i - - 1 I Y111\I 11111111111 \ V 4 II1111111\11�11 yl 11111111111 III _4� 'i' I �1 1111 Il 11 xl 1L I' 111111111111 I \\i __ .. �II } Mi 'r r - v i�A•, �,�hp �� ; vv� —� ' /�P / ���\��„� ,API°; � j 11 ❑ ❑ � � '�� (. I � — IIIII •\'.. � �� !/ ��m , � �� se �'� III I'I �Iljp�t ; ;�-- �Tmmmm.a ; .�� ,. � � � �� V • I � I I III y I,I illillipillimilill--1 �-- 1111111111111 .. I - VVI 111114111IV\\ iv I. 1 1 I 11 i Y 1 � h III 1I w III'\' re�o�oQ @x oSw'w= w_�o� o lz- olz ou.00u,a Burdette, Jennifer From: Iaserfiche@ncdenr.gov Sent: Wednesday, May 12, 2021 10:30 AM To: Burdette, Jennifer Subject: Pre -Filing Meeting Request Acknowledgement - 536 W Tremont - Ver Attachments: DWR Pre -Filing Meeting Request Form.pdf CAUTION: This email is NOT from McAdams. DO NOT click links or open attachments unless you verify the sender and content. The North Carolina Division of Water Resources has received the Pre -Filing Meeting Request Form for 536 W Tremont that you submitted on 5/12/2021. Attached is a copy of your request. All certification requests (applications) must include documentation that a pre -filing meeting request was submitted to the certifying authority at least 30 days prior to submitting the certification request. The Division can not accept an application for your project earlier than 30 days from this pre -filing meeting request. Applications that do not meet this 30-day requirement will be returned. Please save this email/attachment; it must be submitted with your application to document that this requirement has been met. This email was automatically generated by Laserfiche workflow. Please do not respond to this email address, as responses are not monitored. Contact Name* Contact Email Address* Project Owner* Project Name* Project County* Owner Address:* Is this a transportation project?* Jennifer Burdette burdette@nicadanisco.com RangeWater Real Estate 536 W Tremont Mecklenburg Street Address 5605 Glenridge Dr NE, Ste 775 Address Line 2 aty Atlanta Postal / Zip axle 30342 C Yes c: No Type(s) of approval sought from the DWR: W 401 Water Quality Certification - F- 401 Water Quality Certification - Regular Express F- Individual Permit F- Modification F- Shoreline Stabilization Does this project have an existing project ID#?* C Yes (: No State / Province / Pegion GA Country USA Do you know the name of the staff member you would like to request a meeting with? Alan Johnson Please give a brief project description below and include location information.* The proposed development is for a 5-story apartment development with appro)amately 300 units and structured parking and site amenities. The site of the proposed apartment development is located north of W Tremont Avenue in the Wilmore Neighborhood of Charlotte. The site is composed of one parcel and identified by Mecklenburg County GIS with Parcel ID of 119-064-27. The site is appro)amately 3.45 acres, undeveloped and vacant, but appears to have been developed or used for industrial land uses. By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section 401 Certification Rule the following statements: This form completes the requirement of the Pre -Filing Meeting Request in the Clean Water Act Section 401 Certification Rule. 1 understand by signing this form that I cannot submit my application until 30 calendar days after this pre -filing meeting request. 1 also understand that DWR is not required to respond or grant the meeting request. Your project's thirty -day clock started upon receipt of this application. You will receive notification regarding meeting location and time if a meeting is necessary. You will receive notification when the thirty -day clock has expired, and you can submit an application. Signature * Submittal Date 5/12/2021