Loading...
HomeMy WebLinkAboutNCG030255_MONITORING REPORT_20201123STEELE V "" November 18, 2020 Division of Water Quality Mooresville Regional Office 610 East Center Avenue/Suite 301 Dear Stormwater Enforcement Group: f FCEIVJE�o Nov n3 2020 IWO LanD Qt,a ,,`L�;Cf or kect"o nal Mce Please find enclosed the Stormwater Discharge Outfall Monitoring Reports for 2020 bi-annual reporting for permit numbers NCG030255 and NCSOQ0018 for J.C. Steele and Sons Inc. located in Statesville. All outfall results were below benchmark values. If you have any questions please feel free to contact Curtis Daniels of J. C. Steele & Sons, Inc. at (704) 768-3230 or (704) 872-3681 Ext. 151. Sincerely, Marian Clark President J. C. Steele & Sons, Inc. J.C. STEELE & SONS, INC • 710 S. Mulberry Street • Statesville, NC 28677 • P.O. Box 1834 (28687) +1.704.872.3681 • 800.278.3353 • www.jcsteele.com NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMUR Regional Office. Certificate of Coverage No. NCG03 0 2 5 5 Person Collecting Samples: Curtis Daniels Facility Name: J.C. Steele and Sons Inc Laboratory Name: Statesville Analytical Facility County: Iredell Laboratory Cert. No.: 440 Discharge during this period: X Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions for any benchmark exceedances? ❑ Yes N No If so, which Tier (I, II, or III)? Analytical Monitoring Requirements for Outfalls with Industrial Activities— Benchmarks in (Red) Parameter Parameter Outfal l 1 Outfall 3 Outfall Outfall Outfall Code N/A Receiving Stream Class C C N/A Date Sample Collected MM/DD/YYYY 10/28/2020 10/28/2020 46529 24-Hour Rainfall in inches .28" .28" 00552 Non -Polar Oil & Grease in mg/L (15) <5.10 <5 C0530 TSS in mg/L (100 or 50*) 6.326 1 <2.747 00400 pH in standard units (6.0-9.0) 6.7 6.7 NCOIL New Motor/Hydraulic Oil Usage in O O gal/month 01119 Copper, total recoverable in mg/L (0.010 FW, 0.005 SW) ,OO5Z .008 01051 Lead, total recoverable in mg/ L <O.00Z (0.07S FIN, 0.220 SW) ,OOZ3 01094 Zinc, total recoverable in mg/ L (0.326 O74 0.074 FW, 0.095 SW) 78141 Total Toxic Organics (TTO) in mg/L(1) * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HOW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L. Notes (optional): Outfall #1 is representative of Outfall 2, sample taken at Outfall 1. Ouffall 3 is representative of Outfall 3a, sample is taken at OuHall 3 "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for 11 /18/2020 of Permitte'bjor Delegated Authorized Individual Date