Loading...
HomeMy WebLinkAboutNCG110022_INSPECTION REPORT_20200521ROY COOPER Governor MICHAEL S. REGAN secretary BRIAN WRENN Aafnq Dtrecmr City of Monroe Attention: Kyle Ketchum 775 Treeway Drive Monroe, North Carolina 28110 NORTH CAROLINA EhvftarureeftJ'QU99fity May 21, 2020 Subject: Compliance Evaluation Inspection City of Monroe NPDES Certificate of Coverage — NCG 110022 Union County, North Carolina Dear Mr. Ketchum, Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection we conducted at the Monroe WWTP on May 19, 2020. Please note that in the stormwater inspection report summary we ask that you address the erosion issues. The report should be self-explanatory; however, should you have any questions, please do not hesitate -to contact me at (704) 663-1699 or by E-mail at james.moore@ncdenr.gov. Sincerely, CJ es Moore Assistant Regional Engineer Enclosure cc: Laserfiche NCG110022 North Carolina Department of Environmental Quality. I DMslon of Energy, Mineral and. Land Resources e-do DE Mooresville Regional Office 1 610 East Center Avenue, Suite 3011 Mooresville. North Carolina 28115' Compliance Inspection Report Permit: NCG110022 Effective: 06/01/18 Expiration: 05/31/23 Owner: City of Monroe SOC: Effective: Expiration: Facility: Monroe WWTP County: Union 775 Treeway Dr Region: Mooresville Monroe NC 28110 Contact Person: Kyle Ketchum Title: Phone: 704-282-4612 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 05/19/2020 Primary Inspector: Lily C Kay Secondary Inspector(s): Certification: Phone: Entry Time 01:15PM Exit Time: 02:OOPM Phone: 704-663-1699 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Municipal WWTP > 1 MGD, Stormwater Discharge, COC Facility Status: Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 Permit: NCG110022 Owner - Facility: City of Monroe Inspection Date: 05/19/2020 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: The Stormwater Pollution Prevention Plan (SWPPP) and related documentation was complete including employee training records, monitoring records, and the annual certification. The facility appeared well operated and maintained with some erosion issues. If you have questions, contact me at Lily.Kay@ncdenr.gov or by phone at (704) 235 2137. Page 2 of 3 Permit: NCG110022 Owner - Facility: City of Monroe Inspection Date: 05/119/2020 Inspection Type, Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ■ ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ■ ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ■ ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ■ ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? i ❑ ❑ ❑ # Does the Plan include a BMP summary? ■ ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ ❑ ❑ ❑ # Does the facility provide and document Employee Training? ■ ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ■ ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ■ ❑ 1111 # Does the Plan include a Stormwater Facility Inspection Program? ■ ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ■ ❑ ❑ ❑ Comment: The Stormwater Pollution Prevention Plan (SWPPP) and related documentation was complete including employee training records, monitoring records, and the annual certification. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ ❑ ❑ ❑ Comment: Qualitative monitorinq records were available and complete. Analytical Monitoring Has the facility conducted its Analytical monitoring? Yes No NA NE ❑ ❑ ■❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ■ ❑ Comment: Analvtical monitorinq is not required because there is no vehicle maintenance on site. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ ❑ ❑ ❑ # Were all outfalls observed during the inspection? ■ ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ■ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ ■ ❑ Comment: There are 3 outlets, two of which have erosion issues. Outlet 001 has minor erosion in the ditch leading to the outlet. Outlet 003 has maior erosion caused by the 2018 hurricanes and will be addressed with a FEMA funded project. Page 3 of 3