Loading...
HomeMy WebLinkAboutNC0062855_NPDES Permit Renewal_20051117MEMORANDUM TO: FROM: THROUGH: SUBJECT: DIVISION OF WATER QUALITY November 17, 2005 Frances Candelaria NPDE \rmits Archdale Building Dale Lopez \��` Belinda S. Henson, Regional Water Quali Major NPDES Permit Renewal Town of Robbins NC0062855 Moore County rvisor, FRO ` C6q2 0 Please find attached the Staff Report and Recommendations of the Fayetteville Regional Office concerning the subject project. If additional information or clarification is required, please advise. Enclosure Cc: Dale Lopez, FRO Mike Lawyer, FRO Central Files SOC PRIORITY PROJECT: YES_ NO X To: Permits and Engineering Unit Water Quality Section Attention: Francis Candelaria Date: November 17, 2005 NPDES STAFF REPORT AND RECOMMENDATION COUNTY: Moore Permit No. NC0062855 PART I - GENERAL INFORMATION 1. Facility and Address: Town of Robbins PO Box 296 Robbins, NC 27325 2. Date of Investigation: November 1, 2005 3. Report Prepared by: Dale Lopez, Environmental Specialist, FRO 4. Persons Contacted and Telephone Number: James Britt (910) 948-3063 5. Directions to Site: From intersection of SR 1002 & NC 705, travel approximately 1 mile Northwest on 705 to Sewer Plant Road 6. Discharge Point(s), List for all discharge points: WWTP Latitude: 35 26' 40" Longitude: 79 35' 40" Discharge Point Latitude: 35 25' 45" Longitude: 79 33' 12" U.S.G.S.Quad No. F-20 NE U.S.G.S. Quad Name: Robbins, NC 7. Site size and expansion area consistent with application? X Yes _ No (If No, explain) Application did not reference area available for expansion. It does not appear land would be available should facility expand. 8. Topography: WWTP site is flat. The surrounding topography does dramatically change at the WWTP boundary; it is immediately adjacent to Bear Creek. 9. Location of nearest dwelling: None observed within 900 feet. 10. Receiving stream or affected surface waters: Deep River a. Classification: C-HWQ b. River Basin and Subbasin No.: 03-06-10 b. River Basin and Subbasin No.: 03-06-10 c. Describe receiving stream features and pertinent downstream uses: Fish and wildlife propagation, small hydroelectric impoundment downstream of discharge. PART II - DESCRIPTION OF WASTES AND TREATMENT WORKS 1. a. Volume of wastewater to be permitted: 1.3 MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the Wastewater Treatment facility? 0.5 MGD c. Actual treatment capacity of the current facility (current design capacity). 0.5 MGD d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two (2) years. None e. Please provide a description of existing or substantially constructed wastewater treatment facilities: The existing facility consists of the following: Headworks: located approximately 275 yards away from the main facility. The headworks consist of mechanical influent grit removal, manual and automatic bar screens, waste is then pumped via three (3) submersible dry pit influent pumps to main treatment units. The headworks has backup power. Main Units: consists of an influent splitter box to two (2) 0.65 MGD units each consisting of a 0.65 MGD aerated activated sludge basin utilizing fine -air diffusers in the outer ring with 0.75MGD center clarifier. Flow is then combined to enter a duel train gas chlorination basin, dechlorination basin with one (1) wet well post diffused aeration basin. Flow is measured via ultrasonic flow meters (one [1] per side) and effluent travels via gravity 4.2 miles to the Deep River. Sludge holding and treatment consist of one (1) 0.4 MGD primary digester/holding tank abandoned, one (1) 0.1 MGD secondary aerobic digester/holding tank with diffused aeration, and drying beds used only on an emergency basis. Chemical storage/feed facilities are included for alum and caustic. Standby generator is present for main units operation. f. Please provide a description of proposed wastewater treatment facilities: N/A g. Possible toxic impacts to surface waters: None not known or expected. h. Pretreatment Program: In development Should be required Approved X Not needed 2. Residuals handling and utilizing/disposal scheme: Residual Contractor: Town hauls and applies residuals Telephone: Robbins WWTP — (910) 948-3063 b. Residuals stabilization: PSRP X PFRP Other c. Landfill: d. Other disposal/utilization scheme (specify): N/A 3. Treatment plant classification (attach completed rating sheet): Grade II (see attached completed rating sheet) PART III - EVALUATION AND RECOMMENDATIONS It is the recommendation of this office, in keeping with basinwide strategy, that this Permit be reissued as a tiered permit at 0.5 MGD that allows for the return to 1.3 MGD once the discharge flow exceeds the Grade III 0.500 MGD. Signature of Report Preparer •(-(1 a J Water Quality Regional Supervisor Date MONITORING REPORT(MR) VIOLATIONS for: • Permit: nc0062855 MRs Between 8=2003 and 8-2005 ;Region % Facility Name: % Param Name: % County: % Report Date: 10/28/05 Page: 1 of 1 Violation CategoryLimit Violation Program Category: NPDES WW, Subbasm. % Violation. Action: %. PERMIT: FACILITY: COUNTY: REGION: MONITORING OUTFALL REPORT /PPI LOCATION PARAMETER VIOLATION DATE FREQUENCY 12/31/69 UNIT OF MEASURE LIMIT CALCULATED VALUE VIOLATION TYPE VIOLATION ACTION yffluent Toxicity Testing Self -Monitoring Summary October 17, 2005 -4i'ILITY REQUIREMENT YEAR JAN FED MAR APR MAY JUN JUL AUG SBP OCT NOV DEC M▪ oore County WWTP chr lim: 41 % y 2001 --- Pass Pass Pass Pass NC0037S08/00 I Begin:1/1/2005 Frequency: 0 Mar Jun Sep Dee + NonComp:Single 2002 -- Pass Pass -- Pass - Pass County: Moore Region: FRO Subbasin: LUM50 2003 _ Pass --- Pass -- -- Pass -- -- Pass PF: 6.7 Special 2004 50(p) -- Pass >82(p) Pass >82(P) -- -- Pass >71(P) - Pass 7Q10: 15.2 IWC(%) 40.54 Order: 2005 -- -- Pass Pass -- - Pass Mt. Gilead WWTP chr lim: 3.2% NC0021105/001 Begin:3/1/2005 Frequency: Q Mar Jun Sep Dec County: Montgomery Region: FRO Subbasin: YADIO PF: 0.85 Special 7Q10: 40 IWC(%) 3.2 Order: + NonComp:Single 2001 -- 2002 - 2003 - 2004 - 2005 -- - NR NR Pass Pass - Pass - Pass Pass Pass -- -- Pass - -- Pass Pass - Late Pass Pass Pass -- Pass ' - - Pass Pass -- Pass - Pass Pass North Harnett Regional WWTP ac lim: 90%; PF>0.75, chr lira 1.6% 2001 Pass -- Pass - Pass --- Pass NC0021636/001 Begin:3/I/2005 Frequency: Q + Jan Apr Jul Oct + NonComp:Single 2002 Pass - - Pass - - Pass -- -- Pass County: Harnett Region: FRO Subbasin: CPF07 2003 Fail,Pass - -- Pass - - Pass -- - Pass PF: 0.75 Special 2004 Pass Pass -- - Pass -- Pass 7Q10: 550.0 IWC(%) 0.21 Order 2005 Pass Pass - Pass Pnrkton WWTP chr lim: 90% NC0026921/001 Begin:12/12004 Frequency: Q Jan Apr Jul Oct County: Robeson Region: FRO Subbasin: LUM53 PF: 0.2 Special 7010: 0.0 IWC(%) 100 Order: + NonComp:Single 2001 82.16 82.16 35.4 94.9 -- Pass -- Fail >100 35.4 2002 >100 - -- Pass - - Pass -- - Fail 94.9 <25 2003 <25 >100 33.5 Pass - Fail 94.9 >100 Pass - - 2004 Pass - -- Pass - Pass -- Pass - - 2005 NR/Fail >100 >100 Pass - -- NR/Pass - . Pembroke W WTP chr lim: 1.7% NC0027103/001 Begin:9/1/2004 Frequency:0 Jan Apr Jul Oct County: Robeson Region: FRO Subbasin: LUM51 PF: 1.33 Special 7010: 120 IWC(%) 1.8 Order. 4 NonComp:Single 2001 Pass Pass - -- Pass - - Pass 2002 Pass - - Pass - -- Pass Pass 2003 Pass -- -- Pass - Pass Pass 2004 Pass>6.8(p) - -- >6,8(p),Pass Pass -- Pass 2005 Pass -- -- Pass Pass Raeford WWTP chr lim: 9% NC0026514/001 Begin:12/12002 Frequency: Q Feb May Aug Nov County: Hoke Region: FRO Subbasin: CPF15 PF: 3.0 Special 7010: 49.0 IWC(%) 8.67 Order: + NonComp:Singlc 2001 -- Pass - Pass - Pass -- -- Pass 2002 -- Pass - Pass - - Fall >18 >18 Pass 2003 - Pass - -- Fail 5.20 >18,Pass Pass -- -- Pass 2004 _- Pass Pass -- -- Pass - Pass 2005 -- Pass Pass Pass Red Springs WWTP cltr lim: 90% NC0025577/001 Begin:12/12004 Frequency: Q Jan Apr Jul Oct County: Robeson Region: FRO Subbasin: LUM52 PF: 2.5 Special 7Q 10: 0.07 IWC(%) 98 Order. + NonComp:Single 2001 <12.5 61.2 82.2 >90 35.4 35.4 >90 82.2 <12.5 <12.5 61.2 Invalid 2002 Late Late >90 >90 82.2 35.4 >90 -- >90 58.1 58.1 33.5 2003 <12.5 >90 33.5 >90 17.7 58.1 58.1 >90 >90 <12.5 17.7 33.5 2004 >99 33.5 >90(0 17.7 >900) >90(1),02.5 >90(1),Lala 58.1 >100(Ot >90(f)1 >90(0,58.1f >90 >90(0 >90,>90(1) >90,>90(0 >90 >90(0 2005 >90,>90(1) >90>90(1) >90,>900) >90,>90(1) >90,>90(0 >90>90(1) >90(1),>90 >90(0>90 Robbins WWTP chr lim: 10% @ 1.3 MOD; 4.0% Q 0.SMGD 2001 Pass - Pass -- - Pass NR NC0062855/001 Begin:7/I2002 Frequency: Q Jan Apr Jul Oct + NonComp:Single 2002 Pass Pass - - Pass Pass ' County: Moore Region: FRO Subbasin: CPFIO 2003 Pass - Pass -- -- Pass -- Pass 1F: 1.3 Special 2004 Pass -- - Pass - Pass -- -- Pass 7010: 18.7 . IWC(%) 10 Order: 2005 Pass,>20(P) - - Pass>20(P) - Pass,>20(P) -- - - - - Pass Rockingham WWTP chr lim: 8% 2001 - Pass - Pass -- - Pass - Pass NC0020427/001 Begin:6/1/2004 Frequency: Q Feb May Aug Nov + NonComp:Single 2002 - Pass Pass Pass - Pass _ County: Richmond Region: FRO Subbasin: YADI 6 2003 -- Pass - Pass -- Pass>32(p) Pass>32(p) _- PF: 9.0 Special 2004 _- Pass - Pass>32(P) - --- Pass Pass 7010: 153 )WC(%) 8.0 Order: 2005 - Pass - - Pass -- - Pass - - -. - Roseboro WWTP chr lim: 52% 2001 -- Pass Pass -- Pass - Pass NC0026816/001 Degin:12/12003 Frequency: Q Feb May Aug Nov + NonComp:Single 2002 -- Pass - - Pass - - Pass -- - Pass County: Sampson Region: FRO Subbasin: CPF19 2003 - Pass Pass - -- Pass -- Pass PF: 0.49 Special 2004 _. Pass Pass -- Pass Pass 7010: 1.0 IWC(%)52 Order. 2005 -- Pass - - Pass - Pass Smithfield Packing Co., Tonccel Div. chr lim: 0.58% NC0078344/001 Begin:12/12002 Frequency: Q Jan Apr Jul Oct County: Bladen Region: FRO Subbasin: CPF16 PF: 3.0 Special 7010: 795 IWC(%) 0.58 Order + NonComp:Single 2001 Pass - - Pass - - Pass - Pass,Pass - 2002 Pass - Pass - Pass Pass - 2003 Pass - - Pass - Pass - Pass 2004 Pass -- - Pass - -- Pass Pass - 2005 Pass -- Pass Pass y Pre 2001 Data Available LEGEND: PERM = Permit Requirement LET = Administrative Letter - Target Frequency = Monitoring frequency: Q- Quarterly; M- Monthly; BM- Bimonthly; SA- Semiannually; A- Annually; OWD- Only when discharging; D- Discontinued monitoring requirement Begin = First month required 7010 = Receiving stream low flow criterion (cfs) += quarterly monitoring increases to monthly upon failure or NR Months that testing must occur - ex. Jan, Apr, Jul, Oct NonComp = Current Compliance Requirement PF = Permitted flow (MGD) IWC%= Inslream waste concentration • P/F = Pass/Fail test AC = Acute CHR = Chronic Data Notation: f - Fathead Minnow; • - Ceriodaphnia sp.; my - Mysid shrimp; ChV - Chronic value; P - Mortality of stated percentage at highest concentration; at - Performed by DWQ Aquatic Tox Unit; bt - Bad test Reporting Notation: -- = Data not required; NR - Not reported Facility Activity Status: I - Inactive, N - Newly Issued(To construct); H - Active but not discharging; 5-More data available for month in question; = ORC signature needed 4 225 Green Street — Suite 714, Fayetteville, North Carolina 28301-5043 Phone: 910-486-1541 1 FAX: 910-486-0707 \ Internet: www.enr.state.nc.us/ENR/ An Equal opportunity / Affirmative Action Employer - 50 % Recycled 10 % Post Consumer Paper Michael F. Easley, Governor November 8, 2005 Mr. James R. Britt Town Administrator Post Office Box 296 Robbins, NC 27325 Subject: BIOMONITORING INSPECTION COMPLIANCE EVALUATION INSPECTION (CEI) Town of Robbins WWTP NPDES Permit No. NC0062855 Moore County Dear Mr. Britt: AVA NCDENR North Carolina Department of Environment and Natural Resources William G. Ross Jr., Secretary Alan W. Klimek, P.E., Director Coleen H. Sullins, Deputy Director Division of Water Quality Enclosed you will find a copy of the Compliance Evaluation Inspection (CEI) report for the inspection conducted on October 31, 2005 at the Town of Robbins Wastewater Treatment Plant, accompanied by Brant Sikes, Town of Robbins ORC. As part of the inspection a tour of the Wastewater Treatment Plant was conducted. All observations and recommendations are in Section D. Summary of Findings/Comments of this inspection report. In the future, a sampling inspection for the whole effluent toxicity and chemistries will be performed at your facility and combined with this CEI report. The wastewater treatment plant appeared to be in compliance with the Town of Robbins NPDES permit. Please note that the housekeeping that was performed by the ORC was acceptable. However, the appearance of the grounds of the wastewater treatment plant was below average and not favorable. It was blemished by the accumulative collection of several items in disrepair: vehicles that included a fire truck, a street department truck, a Buick car, a Dodge Ram truck (that was the former wastewater treatment plant truck), a 2,000 gallon sludge hauling truck (that was the former wastewater treatment plant sludge hauling truck), a police car, a generator, a pump, a conventional bar screen, and stainless steel diffusers; and, there were rock piles, brush piles, and dirt piles located near the front gate. Please send a letter to this office by January 1, 2006, that explains the purpose of keeping the above listed items on the premises of the wastewater treatment plant, and please include a Plan -of -Action for the removal of the above mentioned items. One NorthCarolina Naturally Mr. Britt November 8, 2005 Page 2 You and your staff are commended for your continued efforts to comply with the NPDES permit. If you have any questions or comments concerning this report or require clarification on part(s) of this report, please feel free to contact me at 910/486-1541, ext. 712. Sincerely, Dale Lopez Environmental Specialist cc: Brant Sikes, Town of Robbins ORC Enclosures: EPA Water Compliance Inspection Report Regional Field Inspectors Check List for Field Parameters Facility Site Review (checklist) United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) • Transaction Code NPDES yr/mo/day Inspection 1 I,I 2 151 31 300062055 111 121 05/10/31 1 17 Type Inspector Fac Type 1.8L1 r-JI 1911 c- I 201 1111 II ll l 11l•l 1166 Remarks 21I1111111 1111111111111111 I.111 H1I Inspection Work Days Facility Self -Monitoring Evaluation Rating • B1 QA 671 2.0 169 70I 31 711 I 7211,11 —Reserved 731 I 174 751 I I 1 1 1 I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Robbins WWTP Sower Plant Rd Robbins NC 27325 Entry Time/Date 11:15 AM 05/10/31 Permit Effective Date 05/06/01 Exit Time/Date 03:00 PM 05/10/31 Permit Expiration Date 06/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Jimmy Brant Sikes/ORC/91.0-943-3053/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted James R Britt, Jr, PC Box 296 Robbins NC 27325//910-946-'431 / No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement N Operations & Maintenance ® Records/Reports Self -Monitoring Program N Facility Site Review Effluent/Receiving Waters ■ Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and ignature(s) of Inspector(s) Agency/Office/Phone and Fax Dale Lopez FRO i;Q/ /9ic-486-1541 at Numbers Date xt.712, / / i S Signature of Management Q Reviewer Agency/Office/Phone and Fax Numbers Date .)1, c; A) Il/ `j/S S EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. NPDES yr/mo/day Inspection Type 31 rrc0062855 111 121 05/10/31 117 181- cl Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The wastewater treatment plant was found to be in compliance with the Town of Bobbins NPDES permit. A Compliance Biomonitoring Inspection will be scheduled in the near future, and this CEI report will be included with the Compliance Biomonitoring Inspection (BID) report. The general wastewater treatment plant housekeeping that was performed by the ORC was acceptable. However, the appearance of the grounds of the wastewater treatment plant was below average and not favorable. It was blemished by the accumulative collection of several items in disrepair: vehicles that included a fire truck, a street department truck,. a Buick car, a Dodge Ram truck (that was the former wastewater treatment plant truck) , a 2,000 gallon sludge hauling truck (that was the former wastewater treatment plant sludge hauling truck), a police car, a generator, a pump, a conventional bar screen, and stainless steel diffusers; and, there were rock piles, brush piles, and dirt piles located near the front gate. Please send a letter to this office by January 1, 200G that explains the purrppose of keeping the above listed items on the premises of the wastewater treatment plant, and please also include a Plan -of -Action for the removal of the items. (cont.) 1 Permit: NC0062855 Owner • Facility: Robbins WWfP Inspection Date: 10/31/2005 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? ■ n n n _ Is the facility as described in the permit? ■ n n n Are there any special conditions for the permit? ■ n n n Is access to the plant site restricted to the general public? ■ n n n Is the inspector granted access to all areas for inspection? ■ n n n Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ n n n Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH. DO, Sludge ■ n n n Judge, and other that are applicable? Comment: The general wastewater treatment plant housekeeping performed by the ORC was acceptable. However, the appearance of the grounds of the wastewater treatment plant was below average, blemished by the accumulative collection of what appeared to be junked vehicles that included a fire truck, a street department truck, a Buick car, a Dodge Ram truck (that was the former wastewater treatment plant truck), a 2,000 gallon sludge hauling truck (that was the former wastewater treatment plant sludge hauling truck), and a police car. There were rock piles, brush piles, and dirt piles located near the front gate. A generator, a pump, a conventional bar screen, and stainless steel diffusers were also on the wastewater treatment plant premises. All of the above mentioned items appeared in a condition of disrepair. Pump Station - Influent Is the pump wet well free of bypass lines or structures? Is the wet well free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? Comment: Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Grit Removal Type of grit removal a.Manual b.Mechanical Is the grit free of excessive organic matter? Is the grit free of excessive odor? Is disposal of grit in compliance? Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn Yes No NA NE ■ ■ ■ nnn ■ nnn ■ nnn ■ nnn Yes No NA NE n ■ ■ nnn ■ nnn ■ nnn Permit: NC0062855 Owner - Facility: Robbins WWTP Inspection Date: 10/31/2005 Inspection Type: Compliance Evaluation Grit Removal Comment: Once per day, Monday through Friday, the grit rake is manually turned on. The grit chamber motor had excessive noise and vibration. According to the ORC, a new bearing is needed. Presently, rainwater that falls into the open grit collection barrels will drain onto the ground. Please remedy this situation so that contaminated water will not flow onto the ground. Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ■ n n n Is the site free of excessive buildup of solids in center well of circular clarifier? • n n n Are weirs level? ■ n n n Is the site free of weir blockage? ■ n n n Is the site free of evidence of short-circuiting? ■ ❑ n n Is scum removal adequate? • n n n Is the site free of excessive floating sludge? ■ ❑ n n Is the drive unit operational? ■ n n n Is the return rate acceptable (low turbulence)? ■ n n n Is the overflow clear of excessive solids/pin floc? ■ n n n Is the sludge blanket level acceptable? (Approximately'! of the sidewall depth) ■ n n n Comment: The scum captured in the scum trough is returned to the Return Sludge Wet Well. The clarifier trough is cleaned each Friday. Pumps_RAS_WAS Yes No NA NE Are pumps in place? ■ n n n Are pumps operational? ■ n n n Are there adequate spare parts and supplies on site? ■ n n n Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? ■ n n n Are surface aerators and mixers operational? • n n n Are the diffusers operational? • n ❑ n Is the foam the proper color for the treatment process? ■ n n n Does the foam cover less than 25% of the basin's surface? n ■ n n Is the DO level acceptable? n ■ n ❑ Is the DO level acceptable?(1.0 to 3.0 mg/I) ■ n n n Comment: #1 Blower needs a new starter. According to the ORC, the foam is due to a long detention time in the activated sludge system. Disinfection -Gas Yes No NA NE Are cylinders secured adequately? n n n ■ Are cylinders protected from direct sunlight? ❑ n ❑ ■ Is there adequate reserve supply of disinfectant? ■ n n 11 Is the level of chlorine residual acceptable? ■ n n n Is the contact chamber free of growth, or sludge buildup? ■ ❑ ❑ 11 Is there chlorine residual prior to de -chlorination? ■ n n n Comment: De -chlorination Yes No NA NE Yes No NA NE Permit: NC0062855 Owner- Facility: Robbins WWTP Inspection Date: 10/31/2005 Inspection Type:. Compliance Evaluation De -chlorination Yes No NA NE Type of system ? Gas Is the feed ratio proportional to chlorine amount (1 to 1)? • n n n Is storage appropriate for cylinders? • n n n Is de -chlorination substance stored away from chlorine containers? ❑ n ❑ • Comment: Are the tablets the proper size and type? n ❑ • ❑ Are tablet de -chlorinators operational? ❑ ❑ • n Number of tubes in use? Is the feed ratio proportional to chlorine appropriate? (Approximately ratio 1:1) n n n • Comment: Standby Power Yes No NA NE Is automatically activated standby power available? n ■ n ❑ Is the generator tested by interrupting primary power source? • n n n Is the generator tested under load? • n n Was generator tested & operational during the inspection? • n n ❑ Do the generator(s) have adequate capacity to operate the entire wastewater.site? • n n n Is there an emergency agreement with a fuel vendor for extended run on back-up power? • n n n Is the generator fuel level monitored? ■ n n n Comment: Manual Switch Gear Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? • n ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? ■ n ❑ n Is the facility using a contract lab? ■ n rl 11 Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? • n n n Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? n ❑ ■ 11 Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ n ■ El Comment: Flow Measurement - Effluent Yes No NA NE Is flow meter used for reporting? • n ❑ n Is flow meter calibrated annually? ■ n n n Is the flow meter operational? • ❑ ❑ n (If units are separated) Does the chart recorder match the flow meter? n n n U Comment: Last flow meter calibration was on 03/30/05 and on 09/23/05. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? i♦ n ❑ n Is all required information readily available, complete and current? ■ ❑ ❑ El Are all records maintained for 3 years (lab. reg. required 5 years)? ■ n n n Are analytical results consistent with data reported on DMRs? • n Ell Is the chain -of -custody complete? ■ n n n Dates, times and location of sampling U Name of individual performing the sampling ■ Results of analysis and calibration • Permit: NC0062855 Owner- Facility: Robbins WWTP Inspection Date: 10/31/2005 Inspection Type: Compliance Evaluation Record Keeping Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Rodney Kiser (Back -Up ORC) Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: According to the ORC, the trail was overgrown. Yes No NA NE ■ ■ ■ ■ nnn ■ nnn nn■n ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn Yes No NA NE ■ nnn ■ nrn ■ nnn ■ nnn ■ nnn ■ nnn Yes No NA NE n orm nnn■ n nn■ PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins OUTFALL: 001 EFFLUENT COUNTY: Moore PERIOD ENDING MONTH: 8 - 2004 REGION: Fayetteville DMR 12 Month Calculated PAGE 1 OF 7 00010 deg c Temperature, Water Deg. Centigrade 00095 umhos/cm Specific Conductance 00300 mg/1 DO, Oxygen, Dissolved 00310 mg/1 SOD, 5-Day (20 Deg. C) 00400 su pH 00530 mg/1 Solids, Total Suspended 00556 mg/1 Oil & Grease 00600 mg/1 Nitrogen, Total (as N) 1 -04 21 21 30 2-04 21 21 30 3-04 21 21 30 4-04 21 21 30 5-04 21 21 30 6-04 21 21 30 . 7-04 21 21 30 8-04 21 21 30 9-03 21 21 30 10-03 21 21 30 11 -03 21 21 30 12-03 21 21 30 PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins COUNTY: Moore PERIOD ENDING MONTH: 8 - 2004 REGION: Fayetteville DMR 12 Month Calculated PAGE 2 OF 7 00610 mg/1 Nitrogen, Ammonia Total (as N) • 00665 mg/1 Phosphorus, Total (as P) 00720 ug/1 Cyanide, Total (as Cn) 01002 ug/1 Arsenic, Total (as As) 01027 ug/1 ' Cadmium, Total (as Cd) 01034 ug/1 Chromium, Total (as Cr) 01042 ug/1 Copper, Total (as Cu) 01051 ug/1 Lead, Total (as Pb) 1 - 04 6 1 2-04 6 3-04 6 1 4-04 6 1 5-04 i 6-04 6 1 7-04 6 1 8-04 6 9-03 6 1 10-03 6 1 11-03 6 1 12-03 6 1 PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins COUNTY: Moore PERIOD ENDING MONTH: 8 - 2004 REGION: Fayetteville DMR 12 Month Calculated PAGE 3 OF 7 01067 ug/1 Nickel, Total (as Ni) 01077 ug/1 Silver, Total (as Ag) 01092 ug/1 Zinc, Total (as Zn) 31616 9/100m1 Coliform, Fecal MF, M-FC Broth,44.5C 50050 mgd Flow, in conduit or thru treatment plant 50060 ug/1 Chlorine, Total Residual 71900 ug/1 Mercury, Total (as Hg) TAE6C pass/fail LC50 STAT 24hr ACU Pimephales 1-04 1.3 2-04 1.3 3-04 1.3 4-04 7.:3 5-04 7.3 6-04 1.3 7-04 8-04 1.3 9-03 1.3 10-03 1.3 11 - 03 1.3 12-03 1.3 PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins TGE6C pass/fail P/F STAT 24hr Acu Pimephales TGP3B pass/fail P/F STATRE 7Day Chr Ceriodaphnia 1 - 04 2-04 3-04 4-04 5.-04 6-04 7-04 8-04 9-03 10-03 11 -03 12-03 COUNTY: Moore PERIOD ENDING MONTH: 8 - 2004 DMR 12 Month Calculated PAGE 4 OF 7 REGION: Fayetteville PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins OUTFALL: 001 EFFLUENT COUNTY: Moore PERIOD ENDING MONTH: 8 - 2004 REGION: Fayetteville DMR 12 Month Calculated PAGE 5 OF 7 00010 deg c Temperature, Water Deg. Centigrade 00095 umhos/cm Specific Conductance 00300 mg/1 DO, Oxygen, Dissolved 00310 mg/1 BOD, 5-Day (20 Deg. C) 00400 su pH 00530 mg/1 Solids, Total Suspended 00556 mg/1 Oil & Grease 00600 mg/1 Nitrogen, Total (as N) 1 -04 21 21 30 11.419355 550.5 10.035 0.25 6.5 - 7 4.583333 6.45 1.97 21 21 30 2-04 10.655172 505.25 10.194118 2.5 6.6 - 7 8.5 1.325 8.47 21 21 30 3-04 13.548387 552.285714 9.040909 1.5 6.7 - 7 4.928571 7.72 8.44 21 21 30 4-04 17.1 642.230769 8.409524 0.538462 6.6 - 7 4.692308 1.95 8.41 21 21 30 5-04 23.096774 650.083333 8.116667 0.25 6.5 - 7.2 3.916667 1.25 10.22 21 21 30 6-04 25.366667 704.357143 7.710526 1.714286 6.7 - 7.1 2.642857 2.54 20.19 21 21 30 7-04 27.225806 683.076923 7.631579 3.384615 6.5 - 7.1 4.153846 0 6.45 21 21 30 8-04 25.870968 584.666667 7.847619 0 6.6 - 7.1 4.092308 0 122 21 21 30 9-03 24.733333 581.923077 7.89375 4.538462 6.7 - 7.3 2.615385 1.425 6.07 21 21 30 10-03 21.129032 680.214286 8.468421 1.714286 6.7 - 7.2 4.357143 1.64 7.26 21 21 30 11 -03 18.666667 613.916667 8.729412 10 6.8 - 7.3 4.5 0 5.345 12-03 21 21 30 13.129032 560.6 9.471429 4.6 6.8 - 7.2 5.8 2.2 4.896667 PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins COUNTY: Moore PERIOD ENDING MONTH: 8 - 2004 REGION: Fayetteville DMR 12 Month Calculated PAGE 6 OF 7 00610 mg/1 Nitrogen, Ammonia Total (as N) 00665 mg/1 Phosphorus, Total (as P) 00720 ug/1 Cyanide, Total (as Cn) 01042 ug/1 Copper, Total (as Cu) 01092 ug/1 Zinc, Total (as Zn) 31616 4/100ml Coliform, Fecal MF, M-FC Broth,44.5C 50050 mgd Flow, in conduit or thru treatment plant 50060 ug/1 Chlorine, Total Residual 1 - 04 6 1 1.3 0.183333 0.3025 0 19 200 7.054725 0.209806 2.529412 6 1 1,3 2-04 0.158333 0.3725 0 105 90 5.280917 0.333103 2.076923 6 1 1.3 3-04 0.1 0.456 0 28 130 11.009629 0.265903 4.434783 6 1 1.3 4-04 0.181538 0.5375 0 38 70 12.012433 0.201033 4.47619 6 1 1.3 5-04 0.125 0.612 0 24 150 19.98399 0.211806 5.222222 6 1 1.3 6-04 0.442857 0.53 0 35 0 20.577632 0.200267 1.095238 6 1 1.3 7-04 0.438462 0.43 8 14 0 8.54912 0.207194 0 6 1 1.3 8-04 0.089231 0.375 0 37 35 6.154419 0.241581 1.1 6 1 1.3 9-03 0.184615 0.2925 0 2 0 5.914371 0.204933 13.6 6 1 1.3 10-03 0.178571 0.35 0 41 60 11.125924 0.199935 10 6 1 1.3 11-03 0.116667 0.3425 0 49 60 9.685639 0.189167 7.352941 6 1 1.3 12-03 0.3 0.45 0 39 0 37.027275 0.250871 9.636364 PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins 71900 ug/1 Mercury, Total (as Hg) TGP3B pass/fail P/F STATRE 7Dax Chr Ceriodaphnia 1 - 04 0.001798 1 2-04 0.002358 3-04 0.002316 4-04 0.001927 1 5-04 0.001865 6-04 0.002352 7-04 0.00173 1 8-04 0.001243 9-03 0.001562 10-03 0.0034 1 11 - 03 0.002375 12-03 0.007206 COUNTY: Moore PERIOD ENDING MONTH: 8 - 2004 DMR 12 Month Calculated PAGE 7 OF 7 REGION: Fayetteville PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins OUTFALL: 001 EFFLUENT COUNTY: Moore PERIOD ENDING MONTH: 8 - 2005 REGION: Fayetteville DMR 12 Month Calculated PAGE ► OF 7 00010 deg c Temperature, Water Deg. Centigrade 00095 umhos/cm Specific Conductance 00300 mg/1 DO, Oxygen, Dissolved 00310 mg/1 BOD, 5-Day (20 Deg. C) 00400 su pH 00530 mg/1 Solids, Total Suspended 00556 mg/1 Oil & Grease 00600 mg/1 Nitrogen, Total (as N) 1 -05 21 21 30 2-05 21 21 30 3-05 21 2.1 30 4-05 21 21 30 5-05 21 21 30 6-05 21 21 30 7-05 21 21 30 8-05 21 21 30 9-04 21 21 30 10-04 21 21 30 11 -04 21 21 30 12-04 21 21 30 PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins COUNTY: Moore PERIOD ENDING MONTH: 8 - 2005 REGION: Fayetteville DMR 12 Month Calculated PAGE 2 OF 7 00610 mg/1 Nitrogen, Ammonia Total (as N) • 00665 mg/1 Phosphorus, Total (as P) 00720 ug/1 Cyanide, Total (as Cn) 01002 ug/1 Arsenic, Total (as As) 01027 ug/1 Cadmium, Total (as Cd) 01034 ug/1 Chromium, Total (as Cr) 01042 ug/1 Copper, Total (as Cu) 01051 ug/1 Lead, Total (as Pb) 1 - 05 -6 1 2-05 6 1 3-05 6 7 4-05 6 1 5-05 6 1 6-05 6 1 7-05 ., I 8-05 6 1 9-04 6 1 10-04 6 1 11 - 04 6 1 12-04 6 1 PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins COUNTY: Moore PERIOD ENDING MONTH: 8 - 2005 REGION: Fayetteville DMR 12 Month Calculated PAGE 3 OF 7 01067 ug/1 Nickel, Total (as Ni) 01077 ug/1 Silver, Total (as Ag) 01092 ug/1 Zinc, Total (as Zn) • 31616 #/100m1 Coliform, Fecal MF, M-FC Broth,44.5C 50050 mgd Flow, in conduit or thru treatment plant 50060 ug/1 Chlorine, Total Residual 71900 ug/1 Mercury, Total (as Hg) TAE6C pass/fail LC50 STAT 24hr ACU Pimephales 1 - 05 1.3 2-05 1.3 3-05 1.3 4-05 1.3 5-05 1.3 6-05 1.3 7-05 1.3 8-05 1.3 9-04 1.3 10-04 1.3 11 - 04 1.3 12-04 1.3 PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins TGE6C pass/fail P/F STAT 24hr Acu Pimephales TGP3B pass/fail P/F STATRE 7Day Chr Ceriodaphnia 1 - 05 2-05 3-05 4-05 5-05 6-05 7-05 8-05 9-04 10-04 11 - 04 12-04 COUNTY: Moore PERIOD ENDING MONTH: 8 - 2005 DMR 12 Month Calculated PAGE 4 OF 7 REGION: Fayetteville PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins OUTFALL: 001 EFFLUENT COUNTY: Moore PERIOD ENDING MONTH: 8 - 2005 REGION: Fayetteville DMR 12 Month Calculated PAGE 5 OF 7 00010 deg c Temperature, Water Deg. Centigrade 00094 umhos/cm Conductivity 00095 umhos/cm Specific Conductance 00300 mg/1 DO, Oxygen, Dissolved 00310 mg/1 SOD, 5-Day (20 Deg. C) 00400 su pH 00530 mg/1 Solids, Total Suspended 00556 mg/1 Oil & Grease 1 - 05 21 21 30 11.935484 519.666667 10.18 0.758333 6.3 - 7 7.616667 0 21 21 30 2-05 11.107143 574.166667 9.822222 1.916667 6.5 - 7 5.95 1.625 21 21 30 3-05 12.483871 509.466667 10.072727 1.013333 6.4 - 7.1 7.173333 0 21 21 30 4-05 16.266667 581.083333 9.715 0.208333 6.2 - 7.1 4.841667 0 5 - 05 21 21 30 19.83871 616.538462 9.119048 0 6.4 - 7.2 2.792308 1.3 21 21 30 6-05 23.866667 564.857143 8.53 0.571429 6.5 - 7.4 3.114286 0 21 21 30 7-05 27.258065 502.428571 8.042105 0 6.1 - 7.1 2.585714 0 21 21 30 8-05 27.580645 571.6 7.730435 0 6.2 - 7 2.56 0 21 21 30 9-04 24.266667 553.071429 8.057143 0.592857 6.4 - 7.1 5.992857 0 10-04 21 21 30 21.16129 598.333333 8.53 0.833333 6.6 - 7 5.908333 0 21 21 30 11-04 17.466667 634.846154 9.078947 0.707692 6.7 - 7.2 5.3 2.65 12 - 04 21 21 30 13.064516 490.428571 10.228571 0.171429 6.5 - 7.2 4.428571 0 PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins W WTP CITY: Robbins COUNTY: Moore PERIOD ENDING MONTH: 8 - 2005 REGION: Fayetteville DMR 12 Month Calculated PAGE 6 OF 7 00600 mg(1. Nitrogen, Total (as N 00610 mg/1 Nitro en, Ammonia Total (as N) 00665 mg/1 Phosphorus, Total (as P) 00720 ug/1 Cyanide, Total (as Cn) 01042 ug/1 Copper, Total (as Cu) 01092 ug/1 Zinc, Total (as Zn) 31616 5/100m1 Coliform, Fecal MF, M-FC Broth,44.5C 50050 mgd Flow, in conduit or thru treatment plant 6 1 1.3 1 -05 ' 13.8 0.124167 0.2325 44 26 1.320069 0.266871 6 1 1.3 • 2-05 13.9 0.049167 0.1825 0 37 38 1.7484 0.346643 6 1 1.3 3-05 15.2 0.062 0.202 0 55.5 21.5 3.617028 0.399129 6 1 1.3 4-05 1.77 0.155 0.215 0 70 26 1.795153 0.340533 6 1 - 1.3 5-05 20.5 0.05 . 0.245 . 0 95 28 2.489558 0.186387 6 - 05 6 0.5 24.4 0.038571 0.464 0 84 19 2.939292 0.2494 6 0.5 7-05 17.6 0.05 0.48 0 86 27 7.175881 0.232581 6 0.5 8-05 15.5 0.038 0.312 0 59 21 12.044119 0.211032 6 1 1.3 9-04 18.5 0.062143 0.482 0 26 50 3.572017 0.235933 6 1 1.3 10-04 13.6 0.08 0.315 0 78 42 2.123358 0.216097 6 1 1.3 11-04 21.5 0.073077 0.4 0 0 0 3.959049 0.2371 12-04 6 1 1.3 15.4 0.108571 0.274 0 32 • 31 1.38545 0.236677 PERMIT NUMBER: NC0062855 FACILITY NAME: Town of Robbins - Robbins WWTP CITY: Robbins COUNTY: Moore 50060 ug/1 Chlorine, Total Residual 71900 ug/1 Mercury, Total (as Hg) TGP3B pass/fail P/F STATRE 7Day Chr Ceriodaphnia 1 - 05 0 0.002628 1 2-05 0.769231 0.00207 3-05 3.272727 0.003144 4-05 4.333333 0.002788 1 5-05 0.952381 0.002825 6-05 2.25 0.002604 7-05 0 0.002453 1 8-05 0.454545 0 9-04 0 0.008342 10-04 0 0.006438 1 11 -04 0 0.002925 12-04 0 0.005658 PERIOD ENDING MONTH: 8 - 2005 DMR 12 Month Calculated PAGE 7 OF 7 REGION: Fayetteville