Loading...
HomeMy WebLinkAboutWI0400065_Report of Groundwater Sampling_20210722ROY COOPER Governor ELIZABETH S. BISER Secretory S. DANIEL SMITH NORTH CAROLINA Director Environmental Quality July 22, 2021 Mr. Mark Oliphant 1259 Elon Place High Point, North Carolina 27263 SUBJECT: Laboratory Analytical Results Geothermal Heating/Cooling Water Return Well Permit No. WI0400065 Guilford County Dear Mr. Oliphant: On May 23, 2021, Jim Gonsiewski of the Division of Water Resources (DWR) collected groundwater samples from the influent and effluent access points to your Geothermal Heating/Cooling Water Return Well. The samples were sent to the DWR Central Laboratory in Raleigh, NC for analysis. The samples were analyzed for fecal coliform, bromide, fluoride, chloride, sulfate, total dissolved solids, nitrate, nitrite, aluminum, antimony, arsenic, barium, beryllium. calcium, cadmium, chromium, cobalt, copper, iron, lead, lithium, magnesium, manganese, molybdenum, nickel, potassium, selenium, silver, sodium, thallium, vanadium, and zinc. Laboratory analytical results from the samples did not detect any constituents above the State of North Carolina 15A NCAC 02L .0202(g) (NC2L) groundwater standards. We appreciate your cooperation in the collection of these samples. If you have any questions, please contact me at (336) 776-9800 or via email at jim.gonsiewski@ncdenr.gov. Sincerely, DocuSIgned by: pm. E197886F179D45F... James J. Gonsiewski, P.G. Hydrogeologist Water Quality Regional Operations Section Division of Water Resources, NCDEQ — WSRO enc.: Laboratory Analytical Reports cc: WSRO Electronic Files Laserfiche Files North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 West Hanes Mill Road, Suite 300 I Winston-Salem, North Carolina 27105 336.776.9800 1:`I'_I In 1 I J �1 ] 4 J I 1P HI I_ `t1-I - =r I briI II I 1 I: _ ] - I" I I_ t. t _: 1 • • 1 II., II .fib I - - •I I] . I i` •,i 41 k 'I I I _ =a .1 at if I 1 I .I= `Iita I. _ - - i fi I = I: I '.IF 1: `. 1- 1':. -_ .d1- [a. 1: q J I- I I.{ 1-_• 11- y II - --- 3 41 It ''II if I -._.. -- 6.: :.? '- it .r Ifil: I .. i.1iz :`"Ifx I.,..-- L _ Itrl. II'1 I I II 13I i • 4- I I r1 T P 1 I : - _. tCl iy I AC85162 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Descr.: County: Region: River Basin Emergency COC Yes/No OLIPHANT RESIDENCE 1259 ELON PLACE Guilford Winston-Salem CPF Collector: Report To Collect Date: Collect Time: Sample Depth J GONSIENSKI WSRO 05/2512021 14_35 Visitl0 Location ID: Priority Sample Matrix: Loc. Type: Final Report WSRO NLC ROUTINE GROUNDWATER Water Supply Sample ID: PO Number # Date Received: Time Received: Labworks LoginlD Delivery Method Final Report Date: Report Print Date: AC85162 05/26/2021 08_15 TASCENZO1 NC Courier 7113/21 07/14/2021 If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. CAS # Analyte Name Sample temperature at receipt by lab PQL Result/ Qualifier LAB 0.9 Units °C Method Reference Analysis Date 5/26/21 Validated by MSWIFT Coliform, MF Fecal in liquid 1 MIC 1 B2,Q1 CFU/100m1 SM 9222 D-1997 5/26/21 JJURGEVICH Coliform, MF Total in liquid 1 1 Q1 CFU/100m1 SM 9222 B-1997 5/26/21 JJURGEVICH 7664-41-7 NH3 as N in liquid 0.02 NUT 0.02 U mg/L as N EPA 350 1 REV 2 5/27/21 ALWILLIAMS 14797-55-8 Nitrate as N in liquid 0.02 0.37 mg/L as N EPA 353.2 REV 2 5/27/21 ALWILLIAMS 14797-65-0 Nitrite as N in liquid 0.01 0.01 U mg/L as N EPA 353.2 REV 2 5/27/21 ALWILLIAMS E701177 NO2+NO3 as N in liquid 0.02 0.37 mg/L as N EPA 353.2 REV 2 5/27/21 ALWILLIAMS 24959-67-9 Bromide 0.4 WET 0.4 U mg/L EPA 300.0 rev2.1 6/16/21 ALWILLIAMS 16887-00-6 Chloride 1.0 4.6 mg/L EPA 300.0 rev2.1 6/16/21 ALWILLIAMS 16984-46-8 Fluoride 0.4 0.4 U mg/L EPA 300.0 rev2.1 6/16/21 ALWILLIAMS 14808-79-8 Sulfate 2.0 5.7 mg/L EPA 300.0 rev2 1 6/16/21 ALWILLIAMS Total Dissolved Solids in liquid 12 221 mg/L SM 2540 C-1997 5/26/21 ALWILLIAMS 7440-22-4 Ag by ICPMS 1.0 MET 1.0 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7429-90-5 Al by ICP 50 110 ug/L EPA 200.7 Rev4 4 6/15/21 JJURGEVICH 7440-36-0 Antimony by ICPMS 10 10 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7440-38-2 As by ICPMS 2.0 2.0 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7440-38-3 Ba by ICP 10 19 ug/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH 7440-41-7 Be by ICP 5.0 5.0 U ug/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH 7440-70-2 Ca by ICP 0.10 49 mg/L EPA 200.7 Rev4 4 6/15/21 JJURGEVICH 7440-43-9 Cd by ICPMS 0.50 0.50 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7440-48-4 Cobalt by ICP 50 50 U ug/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH 7440-47-3 Cr by ICPMS 5.0 5.0 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7440-50-8 Cu by ICPMS 2.0 43 ug/L EPA 200.8 Rev5 4 6/15/21 JJURGEVICH 7439-89-6 Fe by I C P 50 130 ug/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH 7440-09-7 K by ICP 0.10 2.3 mg/L EPA 200.7 Rev4 4 6/15/21 JJURGEVICH 7439-93-2 LI ICP 25 25 U ug/L EPA200.7 Rev4 4 6/15/21 JJURGEVICH 7439-95-4 Mg by ICP 0.10 9.2 mg/L EPA 200.7 Rev4 4 6/15/21 JJURGEVICH 7439-96-5 Mn by ICP 10 19 ug/L EPA 200.7 Rev4 4 6/15/21 JJURGEVICH 7439-98-7 Mo by ICPMS 10 10 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7440-23-5 Na by ICP 0.10 11 mg/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL Page 1 of 3 NCrDIA, Laboratory Section R sults/,SampleCoinments/QuafiierDefinitions Sample ID: AC85162 CAS # Analyte Name 7440-02-0 Ni by ICPMS PQL 2.0 Result/ Qualifier 2.5 Method Units Reference ug/L EPA 200.8 Rev5.4 Analysis Date Validated by 6/15/21 JJURGEVICH 7439-92-1 Pb by ICPMS 2.0 2.0 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7782-49-2 Se by ICPMS 1.0 1.0 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7440-28-0 Thallium (TI) ICPMS 2.0 2.0 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7440-62-2 V by ICP 10 10 U ug/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH 7440-66-6 Zn by ICPMS 10 26 ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH Sample Comments MIC:Fecal Coliform-B2-Counts from all filters = 0. MIC:Fecal Coliform-Q1-Sample exceeded holding time prior to receipt at lab. WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or"U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 2 of 3 NC DWI?, La6oratorySection Resu(ts/Sample Comments/QnarifierDefinitions Sample ID: AC85162 CAS # Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to cal B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 ml that would have been B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle: B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea: G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated for G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. J10 Unidentified peak; estimated value. J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate. J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration M Sample and duplicate results are "out of control". The sample is non -homogenous (e.g., VOA soil). The reported value is the lower N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. P Elevated PQL* due to matrix interference and/or sample dilution. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value repo U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tt ✓ Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab error. Y Elevated PQL* due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 3 of 3 AC85163 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Descr.: County: Region: River Basin Emergency COC Yes/No OLIPHANT RESIDENCE 1259 ELON PLACE Guilford Winston-Salem CPF Collector: Report To Collect Date: Collect Time: Sample Depth J GONSIENSKI WSRO 05/25/2021 14:20 VisitlD Location ID: Priority Sample Matrix: Loc. Type: Final Report WSRO NLC ROUTINE GROUNDWATER Water Supply Sample ID: PO Number ft Date Received: Time Received: Labworks LoginlD Delivery Method Final Report Date: Report Print Date: AC85163 05/26/2021 08_15 TASCENZOI NC Courier 7/13/21 07/14/2021 If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. CAS # Analyte Name Sample temperature at receipt by lab PQL Result/ Qualifier LAB 0.9 Units oC Method Reference Analysis Date 5/26/21 Validated by MSWIFT Coliform, MF Fecal in liquid 1 MIC 1 B2,Q1 CFU/100m1 SM 9222 D-1997 5/26/21 JJURGEVICH Coliform, MF Total in liquid 1 1 B2,Q1 CFU/10om1 SM 9222 B-1997 5/26/21 JJURGEVICH 7664-41-7 NH3 as N in liquid 0.02 NUT 0.02 U mg/Las N EPA 350.1 REV 2 5/27/21 ALWILLIAMS 14797-55-8 Nitrate as N in liquid 0.02 0.37 mg/L as N EPA 353.2 REV 2 5/27/21 ALWILLIAMS 14797-65-0 Nitrite as N in liquid 0.01 0.01 U mg/L as N EPA 353.2 REV 2 5/27/21 ALWILLIAMS E701177 NO2+NO3 as N in liquid 0.02 0.37 mg/L as N EPA 353.2 REV 2 5/27/21 ALWILLIAMS 24959-67-9 Bromide 0.4 WET 0.4 U mg/L EPA 300.0 rev2.1 6/16/21 ALWILLIAMS 16887-00-6 Chloride 1.0 4.6 mg/L EPA 300 0 rev2 1 6/16/21 ALWILLIAMS 16984-48-8 Fluoride 0.4 0.4 U mg/L EPA 300.0 rev2.1 6/16/21 ALWILLIAMS 14808-79-8 Sulfate 2.0 5.7 mg/L EPA 300.0 rev2.1 6/16/21 ALWILLIAMS Total Dissolved Solids in liquid 12 211 mg/L SM 2540 C-1997 5/26/21 ALWILLIAMS 7440-22-4 Ag by ICPMS 1.0 MET 1.0 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7429-90-5 Al by ICP 50 170 ug/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH 7440-36-0 Antimony by ICPMS 10 10 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7440-38-2 As by ICPMS 2.0 2.0 U ug/L EPA200.8 Rev5.4 6/15/21 JJURGEVICH 7440-.38-3 Ba by I C P 10 20 ug/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH 7440-41-7 Be by ICP 5.0 5.0 U ug/L EPA 200.7 Rev4 4 6/15/21 JJURGEVICH 7440-70-2 Ca by ICP 0.10 50 mg/L EPA200.7 Rev4 4 6/15/21 JJURGEVICH 7440-43-9 Cd by ICPMS 0.50 0.50 U ug/L EPA 200.8 Rev5 4 6/15/21 JJURGEVICH 7440-48-4 Cobalt by ICP 50 50 U ug/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH 7440-47-3 Cr by ICPMS 5.0 5.0 U ug/L EPA 200.8 Rev5 4 6/15/21 JJURGEVICH 7440-50-8 Cu by ICPMS 2.0 43 ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7439-89-6 Fe by I C P 50 220 ug/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH 7440-09-7 K by ICP 0.10 2.4 mg/L EPA 200.7 Rev4.4 6/15/21 JJURGEVICH 7439-93-2 Li ICP 25 25 U ug/L EPA 200.7 Rev4 4 6/15/21 JJURGEVICH 7439-95-4 Mg by ICP 0.10 9.5 mg/L EPA 200.7 Rev4 4 6/15/21 JJURGEVICH 7439-96-5 Mn by I C P 10 27 ug/L EPA 200.7 Rev4 4 6/15/21 JJURGEVICH 7439-98-7 Mo by ICPMS 10 10 U ug/L EPA 200.8 Rev5 4 6/15/21 JJURGEVICH 7440-23-5 Na by ICP 0.10 12 mg/L EPA 200 7 Rev4.4 6/15/21 JJURGEVICH WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 1 of 3 NC cD`�11 Laboratory Section 1jsu(ts/Sample Canments/Qual r(Definitions Sample ID: AC85163 CAS # Analyte Name 7440-02-0 Ni by ICPMS PQL 2.0 Result/ Qualifier 2.6 Method Units Reference ug/L EPA 200.8 Rev5 4 Analysis Date Validated by 6/15/21 JJURGEVICH 7439-92-1 Pb by ICPMS 2.0 2.7 ug/L EPA 200.8 Rev5 4 6/15/21 JJURGEVICH 7782-49-2 Se by ICPMS 1.0 1.0 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7440-28-0 Thallium (TI) ICPMS 2.0 2.0 U ug/L EPA 200.8 Rev5.4 6/15/21 JJURGEVICH 7440-62-2 V by I C P 10 10 U ug/L EPA 200.7 Rev4 4 6/15/21 JJURGEVICH 7440-66-6 Zn by ICPMS 10 27 ug/L EPA 200.8 Rev5 4 6/15/21 JJURGEVICH Sample Comments MIC:Fecal Coliform-B2-Counts from all filters = 0. MIC:Fecal Coliform-Q1-Sample exceeded holding time prior to receipt at lab. WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL Page 2 of 3 WCOWR Laboratory Section q.fsufts/SampT Comments/QyaCfrer(Definitions Sample ID: AC85163 CAS # Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to cal B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 ml that would have been B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle: B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea: G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated foi G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. J10 Unidentified peak; estimated value. J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate. J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration M Sample and duplicate results are "out of control". The sample is non -homogenous (e.g., VOA soil). The reported value is the lower N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of e N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. P Elevated PQL* due to matrix interference and/or sample dilution. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value repo U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tt ✓ Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab error. Y Elevated PQL* due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 3 of 3