Loading...
HomeMy WebLinkAboutNC0049778_General Permit_20170602Water Resources Environmental Quality Mr. Brent Lockamy, P.E., Town Engineer Town of Southern Pines 140 Memorial Park Court Southern Pines, NC 28387 Dear Mr. Lockamy: ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director RECEIVED June 2, 2017 DEQ/DWR JUN 1 4.2017 WQROS FAYETTEVILLE REGIONAL OFFICE Subject: General Permit No. NCG590000 Certificate of Coverage NCG590018 261 Thunder Rd, Pine Bluff 28373 Southern Pines WTP — PC-1 Moore County General Permit Coverage. In accordance with your application for discharge, the Division is forwarding herewith the subject Certificate of Coverage to discharge under the subject state-NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statue 143-215.1 and the Memorandum of -Agreement between North Carolina and the US Environmental Protection agency dated August 1, 2007 (or as subsequently amended). The following information is included with your permit package: • A copy of the Certificate of Coverage for your discharge with a Supplement • A copy of General Wastewater Discharge Permit NCG590000 • A copy of a Technical Bulletin for the General Wastewater Discharge Permit NCG590000 If any parts, measurement frequencies or sampling requirements- contained in this general permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, the certificate of coverage shall be final , and binding. Please take notice that this Certificate of Coverage (CoC) is not transferable except after notice to the Division of Water Resources. The Division of Water Resources may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be. required by the Division of Water Resources or any other Federal, State, or Local governmental permits that may be required. State of North Carolina 1 Environmental Quality 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-707-9000 Certificate of Coverage Supplemental Information and DMR (eDMR) submittals: The Supplement page attached to the CoC outlines the facility's Water Treatment Plant (WTP) type, discharge flow volume, receiving stream class & supplemental classifications (i.e. Trout Class, NSW), and the Whole Effluent Toxicity testing requirements, if applicable. Most importantly, the Supplement to CoC page identifies the specific Effluent Limitations and Monitoring Requirements sheet your facility is subject to comply with, Section B. (1.) through B. (4.). Changes made to the water purification process, the wastewater treatment process, or chemical usages at the facility require that the permittee notify the Division in writing. Such notifications shall be sent to the DWR/ Water Quality Permitting Section, 1617 Mail Service Center, Raleigh, NC 27699-1617. All facilities are required to submit monthly Discharge Monitoring Reports and no later than 270 days from the effective date listed on the Certificate of Coverage issued with the general permit, the permittee shall begin submitting discharge monitoring reports electronically using NC DWR's eDMR application system. The permittee shall list its Certificate of Coverage number shown in the subject heading of this letter, as its NPDES Permit Number on the DMR (eDMR). Please see Section C in the general permit for more information on Electronic Reporting of Discharge Monitoring Reports and where to send the signed forms. The Permittee is expected to construct any wastewater treatment facilities necessary to provide adequate treatment in order to comply with State Water Quality Standards and permit limitations set forth in this general permit. It is not necessary to obtain an Authorization to Construct from the Division for wastewater treatment systems at WTPs per Session Law 2011-394 adopted on July 1, 2011. NPDES Permit Contact. If you have any questions concerning the requirements of this permit, please contact Derek Denard at telephone number 919-807-6307. S. Jay Zimmerman, P.1irecc or Division of Water Resources, NCDEQ cc: Central Files NPDES General Permit Files/ CoC NCG590018 FRO/DWR Water Quality Regional Operations_Section% Moose County -Health Department ec: Brent Lockamy, Town Engineer, Town of Southern Pines [lockamy@southernpines.net] Aquatic Toxicology Branch / Susan Meadows [susan.meadows@ncdenr.gov] - Aquatic Toxicology Branch / Cindy Moore [cindy.a.moore@ncdenr.gov] Kelly Hayes, PE, PLS, Program Manager, SEPI Engineering & Construction [KHayes@sepiengineering.com] Wastewater Operator Certification Group / Maureen Kinney [Maureen.Kinney@ncdenr.gov] CoC NCG590018 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES CERTIFICATE OF COVERAGE NCG590018 GENERAL PERMIT NO. NCG590000 TO DISCHARGE WASTEWATERS FROM GREENSAND OR CONVENTIONAL TYPE WATER TREATMENT PLANTS AND OTHER DISCHARGES WITH SIMILAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Town of Southern Pines is hereby authorized to discharge wastewater from a conventional water treatment facility designed to treat and discharge 0.182 MGD, with a potable design flow of 1.2 MGD from a facility located at Southern Pines Water Treatment Plant (WTP) 261,.Thunder Rd, Pine Bluff 28373 Moore County to receiving waters designated as Aberdeen Creek in the Lumber River Basin in accordance with the effluent limitations, monitoring requirements, and other application conditions set forth in Parts I, II, and III of General Permit NCG5900000 as attached. This certificate of coverage shall become effective July 1, 2017. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day June 2, 2017. y Zimmerman, P.G., Directo Division of Water Resources By Authority of the Environmental Management Commission 1IPage CoC NCG590018 SUPPLEMENT to CoC In accordance with the NCG590000 General Permit and the information provided in the permittee's application, this facility should use the information below . to determine what Effluent Limitations and Monitoring Requirements it is subject to in the NCG590000 General Permit. The Permittee is required to notify the Division of any modifications made to the water purification process, the wastewater treatment processes, and/or usage of chemicals at the plant. This, notification should be made in writing to the DWR / Water Quality Permitting Section and a modified CoC issued if necessary. 1. Type of Water Purification System identified: Conventional 2. Design Discharge Flow (MGD): 0.182 [0.338 maximum monthly average flow] 3. Receiving Stream / Classification: Aberdeen Creek / C 4. Effluent Limitations_and Monitoring Requirements Permittee is subject to in this General Permit: CONVENTIONAL WTP discharging to FRESHWATER [See Part 1, Section B. (3.)] All facilities are required to submit monthly Discharge Monitoring Reports and no later than 270 days from the effective date of this CoC, the permittee shall begin submitting monthly electronic Discharge Monitoring Reports. Please see Part 1, Section C for eDMR information For Conventional WTPs: 5. This facility is required to perform annual Whole Effluent Toxicity Testing as shown below: Chronic WET test [See Part 1, Section D. (2.)] Using an effluent concentration of 6_1 % and the following Test organism: Ceriodaphnia dubia 2JPage Approximate Facility Boundary Town of Southern Pines Water Treatment Plant 261 Thunder Rd, Pine Bluff 28373 Stream Segment: 14-2-11-(1) Drainage Basin: Lumber Latitude: 35.081829 State Grid/USGS Quad: G21NW / Pinebluff, NC Receiving Stream: Aberdeen Creek Stream Class: C Sub -Basin: 03-07-50 Longitude: -79.462269 AIIC: 030402030202 Outfall 001 [flows southeast] Facility Location Not to Scale r1�ir.1J►W49 r�ri;VIAL +a► General Permit COC NCG590018 Moore County Water Resources Environmental Quality June 2, 2017 Mr. Brent Lockamy, P.E., Town Engineer Town of Southern Pines - 140 Memorial Park Court Southern Pines, NC 28387 ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director Subject: General Permit No. NCG590000 Certificate of Coverage NCG590018 261 Thunder Rd, Pine Bluff 28373 Southern Pines WTP — PC-1 Moore County Dear Mr. Lockamy: General Permit Coverage. In accordance with your application for discharge, the Division is forwarding herewith the subject Certificate of Coverage to discharge under the subject state-NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statue 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated August 1; 2007 (or as subsequently amended). Thefollowing information is included with your permit package: • A copy of the Certificate of Coverage for your discharge with a Supplement • A copy of General Wastewater Discharge Permit NCG590000 • A copy of a Technical Bulletin for the General Wastewater Discharge Permit NCG590000 If any parts, measurement frequencies or sampling requirements contained in this general permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, the certificate of coverage shall be final and binding. Please take notice that this Certificate of Coverage (CoC) is not transferable except after notice to the Division of Water Resources. The Division of Water Resources may require modification or revocation and reissuance of the certificate of coverage. This permitdoes not affect the legal requirements to obtain other permits which may be required by the Division of Water Resources or any other Federal, State, or Local governmental permits that may -be required. State of North Carolina I Environmental Quality 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-707-9000 Certificate of Coverage Supplemental Information and DMR (eDMR) submittals: The Supplement page attached to the CoC outlines the facility's Water Treatment Plant (WTP) type, discharge flow volume, receiving stream class & supplemental classifications (i.e. Trout Class, - NSW), and the Whole Effluent Toxicity testing requirements, if applicable. Most importantly, the Supplement to CoC page identifies the specific Effluent Limitations and Monitoring Requirements sheet your facility is subject to comply with, Section B. (1.) through B. (4.). Changes made to the water purification process, the wastewater treatment process, or chemical usages at the facility require that the permittee notify the Division in writing. Such notifications shall be sent to the DWR/ Water Quality Permitting Section, 1617 Mail Service Center, Raleigh, NC 27699-1617. All facilities are required to submit monthly Discharge Monitoring Reports and no later than 270 days from the effective date listed on the Certificate of Coverage issued with the general permit, the permittee shall begin submitting discharge monitoring reports electronically using NC DWR's eDMR application system. The permittee shall list its Certificate of Coverage number shown in the subject heading of this letter, as its NPDES Permit Number on the DMR (eDMR). Please see Section C in the general permit for more information on Electronic Reporting of Discharge Monitoring Reports and where to send the signed forms. The Permittee is expected to construct any wastewater treatment facilities necessary to provide adequate treatment in order to comply with State Water Quality Standards and permit limitations set forth in this general permit. It is not necessary to obtain an Authorization to Construct from the Division for wastewater treatment systems at WTPs per Session Law 2011-394 adopted on July 1, 2011. NPDES Permit Contact. If you have any questions concerning the requirements of this permit, please contact Derek Denard at telephone number 919-807-6307. S. Jay Zimmerman, P. irec or Division of Water Resources, NCDEQ cc: Central Files NPDES General Permit Files/ CoC NCG590018 FRO/DWR Water Quality Regional Operations Section Moore County Health Department ec: Brent Lockamy, Town Engineer, Town of Southern Pines [lckamy@southernpines.net] Aquatic Toxicology Branch / Susan Meadows [susan.meadows@ncdenr.gov] Aquatic Toxicology Branch / Cindy Moore [cindy.a.moore@ncdenr.gov] Kelly Hayes, PE, PLS, Program Manager, SEPI Engineering & Construction [KHayes@sepiengineering.com] Wastewater Operator Certification Group / Maureen Kinney [Maureen.Kinney@ncdenr.gov] CoC NCG590018 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES CERTIFICATE OF COVERAGE NCG590018 GENERAL PERMIT NO. NCG590000 TO DISCHARGE WASTEWATERS FROM GREENSAND OR CONVENTIONAL TYPE WATER TREATMENT PLANTS AND OTHER DISCHARGES WITH SIMILAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Town of Southern Pines is hereby authorized to discharge wastewater from a conventional water treatment facility designed to treat and discharge 0.182 MGD, with a potable design flow of 1.2 MGD from a facility located at Southern Pines Water Treatment Plant (WTP) 261 Thunder Rd, Pine Bluff 28373 Moore County to receiving waters designated as Aberdeen Creek in the Lumber River Basin in accordance with the effluent limitations, monitoring requirements, and other application conditions set forth in Parts I, lI, and III of General Permit NCG5900000 as attached. This certificate of coverage shall become effective July 1, 2017. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day June 2, 2017. ay Zimmerman, P.G., Directo Division of Water Resources By Authority of the Environmental Management Commission 1Page CoC NCG590018 SUPPLEMENT to CoC In accordance with the NCG590000 General Permit and the information provided in the permittee's application, this facility should use the information below to determine what Effluent Limitations and Monitoring Requirements it is subject to in the NCG590000 General Permit. The Permittee is required to notify the Division of any modifications made to the water purification process, the wastewater treatment processes, and/or usage of chemicals at the plant. This notification should be made in writing to the DWR / Water Quality Permitting Section and a modified CoC issued if necessary. 1. Type of Water Purification System identified: Conventional 2. Design Discharge Flow (MGD): 0.182 [0.338 maximum monthly average flow] 3. Receiving Stream / Classification: Aberdeen Creek / C 4. Effluent Limitations and Monitoring Requirements Permittee is subject to in this General Permit: CONVENTIONAL WTP discharging to FRESHWATER [See Part 1, Section B. (3.)] All facilities are 'required to submit monthly Discharge Monitoring Reports and no later than 270 days from the effective date of this CoC, the permittee shall begin submitting monthly electronic Discharge Monitoring Reports. Please see Part 1, Section C for eDMR information For Conventional WTPs: 5. This facility is required to perform annual Whole Effluent Toxicity Testing as shown below: Chronic WET test [See Part 1, Section D. (2.)] Using an effluent concentration of 6_1 % and the following Test organism: Ceriodaphnia dubia 2IP.age Approximate Facility Boundary Town of Southern Pines Water Treatment Plant 261 Thunder Rd, Pine Bluff 28373 Stream Segment: 14-2-11-(1) Stream Class: C Drainaee Basin: Lumber Sub -Basin: 03-07-50 Latitude: 35.081829 Loneitude: -79.462269 State Grid/USGS Ouad: G21NW / Pinebluff, NC HUC: 030402030202 Receiving Stream: Aberdeen Creek Outfall 001 [flows southeast] Aberdeen Creek [flows southwest] Facility Location Not to Scale *+06411. s •211" Gj ,4 IO r�� General Permit COC NCG590018 Moore County NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Mail the complete application to: N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 VcG-5--q06145 NPDES Permit Number If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name Facility Name Mailing Address City State / Zip Code Telephone Number Fax Number e-mail Address Town of Southern Pines Southern Pines Water Treatment Plant 140 Memorial Park Court Southern Pines NC, 28387 • (91.0)692-1983 (910)692-1085 alindsay@southernpines.net 2. Location of facility producing discharge: Check here if same as above 0 Street Address or State Road 261 Thunder Road RECEIVED/DENR/DWR APR 2 5 2014 Water Resources Permitting Section City Pine Bluff State / Zip Code NC, 28373 County Moore 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Mailing Address City State / Zip Code Telephone Number Fax Number United Water PO Box 1279 Clemmons NC, 27012 (336)766-0270 (336)766-0469 4. Ownership Status: Federal ❑ State ❑ Private ❑ Public El Page 1 of 3 C-WTP 03/05 NPDES PERMIT APPLICATION - SHORT FORM 'C - WTP For discharges associated with water treatment plants 5. Type of treatment plant: ® Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by filtration and disinfection) ❑ Ion Exchange (Sodium Cycle Cationic ion exchange) ❑ Green Sand Filter (No sodium recharge) ❑ Membrane Technology (RO, nanofiltration) Check here if the treatment process also uses a water softener 6. Description of source water(s) (i.e. groundwater, surface water) surface water 7. Describe the treatment process(es) for the raw water: Decant Only 8. Describe the wastewater and the treatment process(es) for wastewater generated by the facility: The backwash water enters decant basin #1 and is allowed to settle and then flows by gravity to basin #2 and is also allowed to settle and then by gravity flows to a pump station which is then dechlorinated and pumped to Aberdeen Creek. 9. Number of separate discharge points: 1 Outfall Identification number(s) 001 10. Frequency of discharge: Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: 7 Duration: 30 minutes every 2 hours 11. Plant design potable flowrate 1.2 MGD Backwash or reject flow 0.1819 average annually Feb 13 to Jan 14 MGD 12. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Aberdeen Creek Page 2 of 3 C-WTP 03/05 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants 13. Please list all water treatment additives, including cleaning chemicals or disinfection treatments, that have the potential to be discharged. none 14. Is this facility located on Indian country? (check one) Yes. ❑ No 15. Additional Information: ➢ Provide a schematic of flow through the facility, include flow volumes at all points in the treatment process, and point of addition of chemicals. ➢ Solids Handling Plan 16. NEW Applicants Information needed in addition to items 1-15: ➢ New applicants must contact a permit coordinator with the NCDENR Customer Service Center. Was the Customer Service Center contacted? ❑ Yes ® No ➢ Analyses of source water collected ➢ Engineering Alternative Analysis ➢ Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a water quality model. 17. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Adam Lindsay Printed name of Person Signing Signatu of Applice6r Date Assistant Town Manager Title North Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) Page 3 of 3 C-WTP 03/05 Distribution Pumps TOWN OF SOUTHERN PINES WATER FILTRATION PLANT 1) -1 DROWNING CREEK HIGH SERVICE 4 PUMPS RAW WATER IMPOUNDMENT 20 MG iAlht,MIAZAAMINIRUVEMAinAAV CHLORINE LIME SODIUM BICARBONATE FLUORIDE PHOSPHATE CHLORINE FILTER BLDG. LOW SERVICE PUMPS FILTER L3LDG. CHLORINE SUPER PULSATOR CLARIFIER FLASH MIXER iiA, -,,A,A;;;Alz:ZAA.,AAAAA, SUPER PULSATOR CLARIFIER ALUM CARBON POLYMER LIME FLASH MIXER AAA;AlT,A;;AA,74.A.,.,:,AA'AA,07 aa.taa,taa,/ ALUM CARBON POLYMER LIME