Loading...
HomeMy WebLinkAboutWQ0009681_Application (FTSE)_19940706F/to MEMO TO: FROM: SUBJECT: State Review Group Ricky Revels Environmental Teccian Procedure Four (4) WQ0009681 McPherson Green Condos Sewer Extension - Public PWC/City of Fayetteville Cumberland County Division of Environmental Management Fayetteville Regional Office 7/21/94 Date State Review Group Review Engineer Buzz Crosby Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: PWC of Fayetteville - Rockfish Creek Wastewater Treatment Plant 2) WWTP design capacity 12.0 MGD 3) NPDES Permit No.: NC0050105 4) Compliance Information: Present treatment plant performance for previous 12 months - beginning 6/93 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 7,680 GPD domestic 100% ; industrial Expiration Date: 05/31/96 ; other 6) Volume from previously approved projects not yet tributary to WWTP 3,681,713 GPD 7) Regional Recommendations: Approval RR/rr Enclosure X Denial �P GKEX88/MP f COMPLIANCE EVALUATION ANALYSIS REPORT O7/i9/94 PAGE i PERMIT--NC0050i85 PIPE--OOi REPORT PERIOD: 9386-9405 LOC---E FACILITY--FAYETTEVILLE - PWC ROCKFISH CK DESIGN FLOW-- 12.0000 CLASS--4 LOCATION--FAYETTEVILLE REGION/COUNTY--06 CUMBERLAND 50050 0000 80530 00610 3i6i6 50060 00300 TGP3B MONTH Q/MGD BOD RE%/T%% NH3-N FEC COLI CHLORINE DO CERI7DPF LIMIT F 7.0000 F ii.00 F 30.0 F i.00 F 200.0 NOL NOL NOL 93/06 5.4300 2.50 3.5 .ii 154.0 .00 8.9i 93/07 5.8709 2.49 4.0 is 172.3 .643 8.53 i 93/08 5.5774 2.07 3.2 .06 45.6 .597 8.43 93/09 6.3933 1.74 i.5 .O8 .325 8.2O 93/i0 6.8741 2.00 .9 .ii i5.O .367 9.ii i LIMIT F 7.0000 F 22.00 F 30.0 F 2.80 F 200.0 NOL NOL NOL 93/ii 6.9400 i.88 .9 .iO 45i.i .278 9.28 93/12 6.8225 1.39 .9 .ii 29.7 .604 9.68 i LIMIT F12.0000 F 12.00 F 30.0 F 2.00 F 200.0 NOL NOL NOL 94/01 7.1354 2.53 i.2 .51 i2.3 .324 iO.52 i 94/02 7.1000 2.73 1.4 .2i 51.3 .349 iO.46 94/03 7.5709 3.7i i.2 .09 46.2 .363 9.52 LIMIT Fi2.0000 F 6.00 F 30.0 F i.00 F 200.0 NOL NOL NOL 94/04 7.0600 2.13 1.0 .04 95.9 8.57 i 94/05 6.7483 3.20 i.5 .47 24.7 9.56 AVERAGE 6.6269 2.36 i.7 .i7 73.1 .456 9.23 i MAXIMUM 9.5000 6.70 8.6 2.80 i4i5.0 i.00 11.60 i MINIMUM 4.5000 .20 .i .03 .0 .020 6.20 i UNIT MGD MG/L MG/L MG/L 4000ML UG/L MG/L PA%%/FAI GKEX88/MP , COMPLIANCE EVALUATION ANALYSIS REPORT 07/i9/94 PAGE 2 PERMIT--NCOO5OiO5 PIPE--001 REPORT PERIOD: 9306-9405 LOC--- E FACILITY--FAYETTEVILLE - PWC ROCKFISH CK DESIGN FLOW-- i2.0000 CLASS 4 LOCATION--FAYETTEVILLE REGION/COUNTY--06 CUMBERLAND 880i0 00400 00600 00665 OiO42 01051 MONTH TEMP PH TOTAL N PHO%-TOT COPPER LEAD LIMIT NOL 9.0 6.0 NOL NOL NOL NOL 93/06 23.i8 7.8-7.2 i4.800 2.3000 .0000 .000O 93/07 24.66 7.8-7.0 i8.000 1.7000 .00OO .00OO 93/08 25.i3 8.0-7.4 i7.i0O 1.8000 46.0000 .00OO 93/09 24.i9 8.0-7.3 i4300 2.i0O0 .0000 .0000 93/iO 21.57 7.9-6.8 16.600 i.9000 ii8.000O .0000 LIMIT NOL 9.0 6.0 NOL NOL NOL NOL 93/ii 20.70 7.8-7.4 12.300 2.0000 0.0000 .000O 93/i2 i8.55 7.7-7.0 14.900 1.8000 35.0000 .00OO LIMIT NOL 9.0 6.0 NOL NOL NOL NOL 94/0i i6.55 8.i-7.0 i2.300 1.7000 .0000 .000O 94/O2 16.2O 17.300 i.6200 .0000 .00OO 94/03 17.47 7.4-6.6 14.700 1.5000 .0000 LIMIT NOL 9.0 6.0 NOL NOL NOL NOL 94/04 i9.60 7.9-7.0 i5.600 1.5600 .0000 .00011) 94/05 2i.33 17.800 i.8iO0 .0000 .00OO AVERAGE 20.76 ----- 15.458 i.8i58 i9.i666 .00OO MAXIMUM 27.00 8.100 18.000 2.3000 ii8.0000 ......... MINIMUM i5.00 6.600 12.300 i.50OO 3i.0OOO UNIT DEQC %U MG/L MG/L UG/L UG/L ' State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director July 6, 1994 MR M.J. NOLAND PWC/FAYET 1EVIT T ,E PO DRAWER 1089 FAYE'ITEVILLE, NORTH CAROLINA 28302 Dear MR NOLAND: • 1=3,EHNR 1, JUL' 8 1994 ENV. MNt'-':::3E) '.N E►7.ETTEVILLE REG. OFFICE Subject: Application No. WQ0009681 McPherson Green Condos Sewers -Public Cumberland County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on July 6, 1994. This application has been assigned the number listed above. PLEASE REFER TO THE ABOVE WATER QUALITY NUMBER WHEN MAKING INQUIRES ON THIS PROJECT. Your project has been assigned to Randy Kepler for a detailed engineering review. Should there be any questions concerning your project, the reviewer will contact you with an additional information letter. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact Randy Kepler at (919) 733-5083. Sincerely, % t Carolyn cCaskill Supervi or, State Engineering Review Group cc: Fayetteville Regional Office Bennett Engineering Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer James G. Martin, Governor William W. Coley, Jr., SecreLary State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh. North Carotin:: 27626-0535 G:ur_!c T. Evcr:a. D;rcct,:r May 1, 1991 .', Memorandum / =r CO, r�- rn To: Delegated Municipalities �' t C„;; , From: Steve W. Tedder, Chief ►c3' Water Quality Section n rn Subject: Delegated Municipalities Checklist for Revised Non -Discharge Permit Applications c. The Division of Environmental Management's Water Quality Section has revised the `' Gravity Sewer Non -Discharge Permit Application Form. The form now incorporates the basic information that the Division feels is necessary in order for the delegated municipalities to perform a review on a gravity sewer project for the Division; therefore, the Division will no longer require that the "Delegated Municipalities Gravity Sewer Design Checklist" be completed and submitted. We do, however, require that the delegated municipality perform the same type of review as always required and complete the bottom portion of this page and attach it as the last page of all gravity sewer applications that are being submitted as a delegated municipalities project. If you have any questions on this matter, please contact Mr. Randy Jones at 919/733-5083. DELEGATED MUNICIPALITY GRAVITY SEWER CERTIFICATION (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) Applicant: McPherson Green Condominiums Project Name: Delegated Municipality Reviewer's Certification: I, VTCTfIR GAN.W..HSANT , attest that the subject plans and specifications have been reviewed under my supervision and that those plans and specifications are consistent with the information that has been specified on the Non -Discharge Application and the Division of Environmental Management's minimum design requirements for gravity sewer projects. Delegated Municipality Reviewer's NC Professional Engineer's Registration No.: _ 14368 Seal and Signature (specify date): FORM: DMGS 4/91 PAGE 1 OF 1 ,,,,,,,, t,,,, 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): Marion J. Noland, PE Director of Water Rescources P.O. Drawer 1089 3. Mailing Address: city: Fayetteville Telephone No.: ( 910 ) 4 8 4 -14 0 l State: NC Zip: 2 8 -1n 2 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.): McPherson Green Condominiums 5. Application Date: 27 Jun 94 6. Fee Submitted: $ 2 0 0. 0 0 7. County where project is located: Cumberland II. PERMIT INFORMATION: 1. Permit No. (will be completed by DEM): i( C7 OO °1 2. Specify whether project is: X new; renewal*; modification. *If renewal, complete only sections I through III and applicant signature (on pg.5). Submit only pgs. 1, 2, 5 (original and 3 copies of each). Engineer signature not required for renewal. 3. If this application is being submitted as a result of a renewal or modification to an existing permit, list the existing permit number N/and issue date 4. Specify whether the applicant is X public or private. FORM: GSEA 4/91 Page 1 of 6 State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management Non -Discharge Permit Application (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) GRAVITY SEWER EXTENSION I. GENERAL INFORMATION: Applicant ration, individual, or Other): Fayetteville, Public Works Commissi.Qr, 1. A PP; C- fr�C`p�r' LIKAV11 I ►7GWZ✓�GA1GlrJ1V1V PAGE 2 (4/91) III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater. 10 0 % Domestic; % Commercial; % Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: Residential Condominiums 3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels: None 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? N/A 5. Volume of wastewater generated by this project: 7,680 gallons per day 6. Explanation of how wastewater volume was determined: 32 dwelling units with 2 bedrooms each X 120 G P D IV. DESIGN INFORMATION: 1. Briefprojectdescription: Extend an 8" San. Sewer Main to serve 32 Condominium Residental Units 2. Name of wastewater treatment facility receiving wastewater. Rockfish Treatment Plant NC 0050105 a. Facility permit no.: b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: The 8" Collection Mains downstream from this project to the Buckhead Creek Outfall and the Buckhead Creek Outfall are adequate for this addition. 2 of 6 • GRAVITY St Wt.K r.Air.NaiON PAGE 3 (4/91) 3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C N factor or N factor is used and circle C or N below: Dia. Len Pipe C oz ) Min. Max. Minimum Max. Minimum (In.) (Lin. F) Material Factor Slope % Slope % Velocity (fps) Vel.(fps) Cover (in) 8 281 VC 0.013 0.40 0.56 2.0 2.3 44 NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be as follows: a. 36 feet separation for slopes of 21% to 35%; b. 24 feet separation for slopes of 36% to 50%; c. 16 feet separation for slopes of 50% and greater. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control measures must be specified. For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? N/A 5. Maximum sewer reach length between manholes: 153 linear feet. 6. This sewer line segment occurs between manhole no?- + 19 and manhole no. 2 + 72 7. Does the owner/operator have the ability to clean this length? X Yes No. 8. Sewer subject to existing or planned traffic bearing loads? X Yes No.. If yes, what measures are being taken to enable the sewers to withstand the loads? The pipe is constructed to support hwy traffic loads. Pipe bedding material and trench backfill will be adequate. 9. Outside drop manholes are provided where invert separations exceed: N/A feet. 10. Identify (by manhole number) those manholes that have drop connections: N/A 3 of 6 GRAVITY SEWER EXTENSION PAGE 4 (4/91) 11. Maximum allowable infiltration/exfiltration test rate: Note: Must not exceed bo PD/ pipe dia. in./ mile. 10 0 GPD/ pipe dia. in./ mile. 12. Minimum separation distances as shown on the plans or addressed in the specifications: a) 100 ft. horizontal separation from wells or other water supplies? x_ Yes No b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? No Crossings _ Yes No c) 10 ft horizontal separation from water mains or 18 in. vertical separation (water over sewer) or ferrous pipe specified? . Yes _ No 13. Are manholes subject to flooding? _Yes . No 14. If yes, are manhole rim elevations 1 foot above 100-year flood level, N/A Yes _ No (100 year flood elevation should be indicated on plans) 15. Or are manholes watertight and vented 1 foot above the 100-year flood elevation ( should be shown on plans): N/AYes _ No 16. Identify (by manhole number) those manholes that are vented: N/A 17. Does this project involve any stream crossings? _ yes �C. no. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required Items a. One original and three copies of the completed and appropriately executed application form. b. Three sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the first page of the specifications must be signed and sealed. Three copies of the existing permit if a renewal or modification. c. The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5). d. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. e. An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. 4 of 6 GRAVITY SEWER EXTENSION PAGE 5 (4/91) Name and Complete Address of Engineering Firm: Bennett Engineering 120 Gillespie Street city: Fayetteville Telephone No. (910) 4 8 4- 5 5 2 3 State: NC Zip:28301-5644 Professional Engineer's Certification: I, Robert M. Bennett , attest that this application for McPherson Green Residential Condominiums has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Registration No. 3823 Print Name of Engineer Robert M. Bennett 'tltltltltlMRk!(k0l 0, Seal and Signature (specify date): Applicant's Certification: I, Marion J. Noland, PE Green, Condominiums .4'`' CCA RO °Y• o e jZ C • �ru n moo° 3 i3 e I iP4k!v:k. tEF*eree�no��/f1e , attest'thatthis application for McPherson has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. Signature Date 6— 307 THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: 919/733-5083 5 of 6 GRAVITY SEWER EXTENSION PAGE 6 (4/91) PERMIT APPLICATION PROCESSING FEES (effective October 1, 1990) CATEGORY NEW APPLICATIONS/ RENEWALS WITHOUT MODIFICATIONS MODIFICATIONS > 1,000,000 GPD Industrial $400 $300 Domestic/Cooling Water $400 $300 10,001- 1,000,000 GPD Industrial Domestic/Cooling Water $400 $250 $250 1,001 - 10,000 GPD Industrial $400 $200 Domestic/Cooling Water $400 $200 < or =1,000 GPD and Single Family Dwelling Sludge < or = 300 Acres Sludge > 300 Acres $240 $120 $400 $250 $400 $250 Sewer Extensions (nondelegated) $400 0 Sewer Extensions (delegated) $200 0 Closed -Loop Recycle or Evaporative $400 $200 NOTE: The Fees for Soil Remediation Projects are the same as for Sludges. Under the Sewer Extension Fee, "delegated to municipalities" applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the Division of Environmental Management. 6 of 6 James G. Martin, Governor \Vilham W. Cobey, Jr_, Secretary Memorandum To: Delegated Municipalities From: Steve W. Tedder. Chief (`\ Water Quality Section k) Sub ct: Delegated N'IU tc#t!I_hts_ckhsi for Revised iron DISC l:if`_`e hl r11L':. ipp i mot: oil; The Division of Environmental Management's Water Quality Section has revised the. Gravity Sewer Non -Discharge Permit Application Form. The form now incorporates the basil information that the Division feels is necessary in order for the delegated municipalities to perfomt review on a gravity sewer project for the Division; therefore, the Division will no longer require that the "Delegated Municipalities Gravity Sewer Design Checklist" be completed and submitted. We do, however, require that the delegated municipality perform the same type of review as always required and complete the bottom portion of this page and attach it as the last page of all gravity seater applications that are being submitted as a delegated municipalities project. If you have any questions on this matter, please contact Mr. Randy Jones at 919f733-5083. DELEGATED MUNICIPALITY GRAVITY SEWER CEP TIFICATTO (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) Applicant: pJBLTC WOKPS COMMTSSTON op THE CTTY C)F FAYFTT'RVTI T.F, NORT1 CAROLINA State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh. North Carotin:. G_ur•_. i c'-cr;;i. `.'li 7 May 1, 1991 Project Name: HE1 SON GREEN Cn&DnMTNIIIMS Delegated Municipality Reviewer's Certification: I, VTCTOR CAN.TFHSANT , attest that the subject plans and specifications have been reviewed under my supervision and that those plans and specifications are consistent with the information that has been specified on the Non -Discharge Application and the. Division of Environmental Management's minimum design requirements for gravity sewer projects. Delegated Municipality Reviewer's NC processional Engineer's Registration N Seal and Signature (specify da:ej: FORM: DMGS 4/91 PAGE 1 OF 1 Ot' ,N CARO(, O •�ESS1r i•SE Al. • 14368 i �1 l z::\(NG N(Cc;"- oR• GAN, ,