Loading...
HomeMy WebLinkAboutWQ0009505_Application (FTSE)_19940525MEMO TO: State Review Group FROM: Ricky Revels Environmental Technician SUBJECT: Procedure Four (4) WQ0009505 Camelot Sewer Extension - Public PWC/City of Fayetteville Cumberland County Division of Environmental Management Fayetteville Regional Office 5/24J94 Date State Review Group Review Engineer Ray Cox Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: PWC of Fayetteville - Rockfish Creek Wastewater Treatment Plant 2) WWTP design capacity 12.0 MGD 3) NPDES Permit No.: NC0050105 Expiration Date: 05/31/96 4) Compliance Information: Present treatment plant performance for previous 12 months - beginning 5/01/93 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 18.720 GPD domestic 100% ; industrial ; other 6) Volume from previously approved projects not yet tributary to WWTP 3,457,943 GPD 7) Regional Recommendations: Approval RR/rr Enclosure X Denial �F%2002 14:54,01 TERMINAL CONNECTED TO IM% IM% KEX88/MP 06/03/94 NN COMPLIANCE EVALUATION ANALYSIS REPORT PAGE i � PERMIT--NC0050iO5 PIPE--001 REPORT PERIOD: 9305-9404 LOC--- E FACILITY--FAYETTEVILLE - PWC ROCKFISH CK DESIGN FLOW-- 12.0000 CLASS--4 LOCATION--FAYETTEVILLE REGION/COUNTY--86 CUMBERLAND 50050 003i0 80530 00610 3i616 50060 00300 TGP3B MONTH Q/MGD BOD RE%/T%% NH3-N FEC COLI CHLORINE DO CERI7DPF , LIMIT F 6.0000 F i2.08 F 30.0 F 2.00 F 208.0 NOL NOL NOL 93/05 5.3548 3.30 5.8 .25 149.0 i.005 9.25 LIMIT F 7.0000 F ii.00 F 30.0 F i.00 F 200.0 NOL NOL NOL 93/06 5.4300 2.50 3.5 .ii 154.0 .7i8 8.91 93/07 5.8709 2.49 4.0 .i8 172.3 .643 8.53 i 93/O8 5.5774 2.07 3.2 .06 45.6 .597 8.43 93/09 6.3933 1.74 1.5 .O8 .325 8.2O 93/10 6.8741 2.00 .9 .ii i5.O .367 9.ii i LIMIT F 7.0000 F 22.00 F 30.0 F 2.00 F 200.0 NOL NOL NOL 93/11 6.9400 i.88 .9 .iO 151.1 .278 9.28 9302 6.8225 1.39 .9 .ii 29.7 .604 9.68 i LIMIT F12.0000 F 12.00 F 30.0 F 2.00 F 200.0 NOL NOL NOL 94/0i 7.1354 2.53 i.2 .5i 12.3 .324 10.52 i 94/02 7.1000 2.73 i.4 .21 51.3 .349 18.46 94/03 7.5709 3.71 1.2 .09 46.2 .363 9.52 LIMIT F12.8000 F 6.00 F 30.0 F i.00 F 200.0 NOL NOL NOL 94/04 7.8600 2.13 i.0 .04 95.9 8.57 i AVERAGE 6.5107 2.37 2.i .15 83.5 .505 9.20 i MAXIMUM 9.5080 6.70 8.6 2.80 i4i5.0 2.i20 11.60 i MINIMUM 4.5000 .20 .i .03 .O .020 6.20 i UNIT MGD MG/L MG/L MG/L 0000ML MG/L MG/L PA%%/FAI " !KEX88/MP � � _ COMPLIANCE EVALUATION ANALYSIS REPORT O6/O3/94 PAGE 2 PERMIT--NC0050i05 PIPE--00i REPORT PERIOD: 9305-9404 LOC--- E FACILITY--FAYETTEVILLE - PWC ROCKFISH CK DESIGN FLOW-- 12.0000 CLASS--4 LOCATION--FAYETTEVILLE REGION/COUNTY--06 CUMBERLAND 880i8 00400 00600 00665 01042 0051 MONTH TEMP PH TOTAL N PHO%-TOT COPPER LEAD LIMIT NOL 9.0 6.0 NOL NOL NOL NOL 93/05 0.25 7.6-7.i 16.500 i.7800 0000 .00OO LIMIT NOL 9.0 6.8 NOL NOL NOL NOL 93/06 23.i8 7.8-7.2 14.800 2.3000 .0000 .O000 93/07 24.66 7.8-7.0 i8.O00 1.7000 .0000 .0000 93/08 25.i3 8.0-7.4 i7.iOO i.8000 46.0000 .0000 93/89 24.49 8.0-7.3 i4.iO0 2.1000 .0000 .000O 9300 0.57 7.9-6.8 16.600 i.9000 ii8.O0OO .00OO LIMIT NOL 9.0 6.0 NOL NOL NOL NOL 93/11 20.70 7.8-7.4 12.300 2.0000 0.0000 .00OO 9302 18.55 7.7-7.0 14.900 i.8000 35.0000 .0000 LIMIT NOL 9.0 6.0 NOL NOL NOL NOL 94/01 16.55 8.i-7.0 12.300 1.7000 .0000 .0000 94/02 16.20 7.9-6.9 i7.300 i.6200 .00OO .00OO 94/03 17.47 7.4-6.6 14.700 i.5000 .0000 .0OOO LIMIT NOL 9.O 6.0 NOL NOL NOL NOL 94/04 19.60 7.9-7.O i5.600 i.5600 .0000 .00OO AVERAGE 20.75 ______ i5.350 1.8066 i9.i666 .0000 MAXIMUM 27.08 8.i0O i8.00O 2.3000 ii8.0000 MINIMUM 15.00 6.600 12.300 1.5000 0.0000 ________ UNIT DEG.0 %U MG/L MG/L UG/L UG/L State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director May 25, 1994 MR STEVEN ROUTH TOWN OF HOPE MILLS 3701 SOUTH MAIN STREET HOPE MILLS, NORTH CAROLINA 28340 Dear MR ROUTH: MAY 27 1994_ ENV. EVILLEMANAGEMENT [ OFFICE �LETI Subject: Application No. WQ0009505 Camelot Sewers -Public Cumberland County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on May 20, 1994. This application has been assigned the number listed above. PLEASE REFER TO THE ABOVE WATER QUALITY NUMBER WHEN MAKING INQUIRES ON THIS PROJECT. Your project has been assigned to Ray Cox for a detailed engineering review. Should there be any questions concerning your project, the reviewer will contact you with an additional information letter. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact Ray Cox at (919) 733-5083. cc: Fayetteville Regional Office Averette Engineering Co. Sincerely, Carolyn Mcgaskill_ Supervisor, State Engineering Review Group Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer S. A'. State of North Carolina Departmei i of Environment, Health, and Natural Resources Division of Environmental Management Non -Discharge Permit Application (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) GRAVITY SEWER EXTENSION I. GENERAL INFORMATION: 1. Applicant (corporation, individual, or other ): Ta4N OF HOPE MILLS 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): STEVEN ROt7TH 3. Mailing Address: 3701 sown MAIN STREET City: HOPE MILLS State: N.C. Zip: 28340 Telephone No.: ( 910 ) 424-4555 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., litters of flow acceptance, Operational Agreements, etc.): 5. Application Date: FEB. 24, 1994 6. Fee Submitted: $ 400.00 7. County where project is located: CUMBERLAND II. PERMIT INFORMATION: 1. Permit No. (will be completed by DEM): /,V ( o Q1 S 2. Specify whether project is: X new; renewal*; modification. *If renewal, complete only sections I through III and applicant signature (on pg.5). Submit only pgs. 1, 2, 5 (original and 3 copies of each). Engineer signature not required for renewal. 3. If this application is being submitted as a result of a renewal or modification to an existing permit, list the existing permit number and issue date N/A 4. Specify whether the applicant is X public or private. FORM: GSEA 4/91 Page 1 of 6 GRAVITY SEWER EXTENSION PAGE 2 (4/91) III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater:100 % Domestic; % Commercial; % Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: EXTEND SANITARY SEWER LINE TO SERVE CAMELOT SUBDIVISION-:52 RESIDENTIAL LOTS ON THIS EXTENSION. 3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels: NONE 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? N/A 5. Volume of wastewater generated by this project: 18,720 gallons per day 6. Explanation of how wastewater volume was determined: 52 X 360 GPD/CONNECTION 120 GPD X 3 BEDROOM = 360 GPD BEDROOM IV. DESIGN INFORMATION: 1. Brief project description: EXTEND EX : STING SANITARY SEWER TO SERVE CAMELOT SUBDIVISION 2. Name of wastewater treatment facility receiving wastewater: ROCKFISH TREATMENT PLANT CITY OF FAYETTEVILLE a. Facility permit no.: Nc0050105 b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: THE SEWERS DOWNSTREAM ARE ADEOUATF TQ ACCEPT THE WASTEWATER FROM THIS SUBDIVISION. 2 of 6 GRAVli : SL\\LK L.\iL\>1U.\ PAGE 3 (4/91) 3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C factor or N factor is used and circle C or N below: N Dia. Length Pipe C or N Min. Max. Minimum Max. Minimum (In.) (Lin. Ft) Material Factor Slope % Slope % Velocity (fps) Vel.(fps) Cover (in) 8" 1025 VCP 0.13 0.40 0.40 2 2.0 36" 12" 1311 VCP 0.13 0.22 0 22 2 2.0 36" 12u 25 DI 0.13 0.22 0.22 2 2 36" NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minFinum diameter is 8 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be as follows: a. 36 feet separation for slopes of 21% to 35%; b. 24 feet separation for slopes of 36% to 50%; c. 16 feet separation for slopes of 50% and greater. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control measures must be specified For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? N/A 5. Maximum sewer reach length between manholes: 312 linear feet. 6. This sewer line segment occurs between manhole no. 0+00 and manhole no. 31195 EASEMENT #2 7. Does the owner/operator have the ability to clean this length? X Yes No. 8. Sewer subject to existing or planned traffic bearing loads? X Yes No. If yes, what measures are being taken to enable the sewers to withstand the loads? SANITARY SEWER SPECIFIED, INSTALLED PROPERLY AT THE DEPTHS INDICATED WILL WITHSTAND NORMAL TRAFFIC BEARING LOADS 9. Outside drop manholes are provided where invert separations exceed: 2 feet. 10. Identify (by manhole number) those manholes that have drop connections: NONE 3 of 6 PAGE 4 (4/91) 1`1 M`aximui;t allowable infiltradon/exfiltrataon test i die. in./ mile. Must not excecdloo GPD/ p-pc d in./ mile. ?�U2 GPD/ pipe 12. Minimum separation distances as shove i ut, tl;i: piaas or adt .sled in the specifications: a) 100 ft. horizontal separation fi'om wells or other water supplies? xL. Ycs No b) .12:in; vc.►4ic a1 separation from storm se.Ver or ferrous pipe sanitary sewer specified? x Ycs No ej 10 ft. horirnta!;separation from wakci rains or 18 in. vertical separation (water over sewer) or fs+, +hs pipe sie,:ificd? x Yes _ No )1, -4: use manholes subje t to flooding? ,Yes x No k 4. ff yes, are manhole rim elevations 1 foot above:100-year flood level, Yes _ No N/A 1Ce year flood elevation should be indicated on plans) ..le are manholes watertight and vented I foot hbrwc the 100-year `Yes — No N/A flood elevation ( should be shown on plans): 6. Identify (by manhole number) those manholes that are vented: N/A L'rL. Does this project involve any stream crossings? _ yes x no. If yes, what precautions or spt cial features- have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: — TIHIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL 1.1.4NAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS APE INCLUDED WITH THE SUBMITTAL v.equired Items One original and three copies of the completed and appropriately executed application forr,I. x'tiree sets of detailed plans and signed and scaled by a North Carolina 'professional Engineer. The plans 2nusJnelude a general location map, a plan view of tt , wer extension, a profile of the sewer extension, and must show the proximity.of the E wet extension to other utilities end natural features. Specifications may be on ittal tog 1clegated.authorities. Each sheci of tile plant, and the first page of the sper-ifitanktris must b signed and sealed. Three copies of the exLydiig permit if a renewal or toodincation. The appropriate permit processing in accordance with I5A NCAC 2H .0205(c)(5). If the owner/authority of the wastewater treatment facility (\VWT) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. 4 of 6 ° < ' V1Ri1 V 11 1 L. L/'* 1Ll•Jav1.• PAGE 5 (4/91) Name and Complete Address of Engineering Firm: AVERETTE ENGINEERING CO- • p-A- 1717 SWANN STREET City: FAYETTEVILLE Telephone No. (910) 488-5656 State: N.C. Zip: 7R101-1741 Professional Engineer's Certification: - I,- CHARLES D. AVERETTE , attest that this application for CAMELOT has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Registration No. 4676 Print Name of Engineer CHARLES D. AVERETTE �,.;�Nunrt,�b , .qb" \H CARO��N' Seal aatttd Signature (specify date): n t ,F�°°° 9 •, f S. e r s e 0 0 r. 1. r c Appli ', can ' Cert' 'cation: ,.. , attest that this application for 7wA) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. Signature -""`� Date VI qK THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: I, .3vtit) (G� NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: 919/733-5083 5of6