Loading...
HomeMy WebLinkAboutNCG500354_Compliance Evaluation Inspection_20210708DocuSign Envelope ID: 9BADD4E0-5AD8-41C7-88C0-F42162B50EFB 51EATEo, 4 ROY COOPER Governor JOHN NICHOLSON Interim Secretary S. DANIEL SMITH NORTH CAROLINA Director Environmental Quality July 08, 2021 David Callahan Slurry Pavers Inc 107 Arendell St Morehead City, NC 28557 SUBJECT: Compliance Inspection Report Slurry Pavers - Morehead City NPDES WW Permit No. NCG500354 Carteret County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Slurry Pavers - Morehead City on 7/07/2021. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NCG500354. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Megan Faulkner with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at megan.faulkner@ncdenr.gov. Sincerely, Do�cuySi�g�ne�dby: �q Y vWY CUAA. � . �vvw,l o�i14a4�Ciez-King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: David Callahan (via email) WQS Wilmington Regional Office-NCG500354 o.o„o..ma..wD� North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington. North Carolina 28405 910.796.7215 DocuSign Envelope ID: 9BADD4EO-5AD8-4lC7-88CO-F42162B50EFB United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCG500354 Ill 121 21/07/07 I17 18 I C I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I n, I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 10:OOAM 21/07/07 20/12/31 Slurry Pavers - Morehead City 107 Arendell St Exit Time/Date Permit Expiration Date Morehead City NC 28557 11:15AM 21/07/07 25/11/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted David Callahan,107 Arendell St Morehead City NC 28557/Acting Facility Manager/252-269-8872/2522223339 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar 0 Records/Reports Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) an i ftl'rts Inspector(s) Agency/Office/Phone and Fax Numbers Date ° envy 7/8/2021 John Perry DWR/Non Discharge Compliance Unit/910 796 7341/ pp Megan D Fau n��rE38ED-Sign aby: DWR/WIRO WQ/910-796-7245/ 7/8/2021 NAoni n. �Cu�Qk�e� t�,. SknTeRwesdnk4doagement Q A Reviewer Agency/Office/Phone and Fax Numbers Date L`�S-6"7/9/2021 BA14AC7DC434... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: 9BADD4E0-5AD8-41C7-88C0-F42162B50EFB NPDES yr/mo/day Inspection Type (Cont.) NCG500354 I11 12I 21/07/07 117 18 i c i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Megan Faulkner and John Perry from the Division of Water Resources (DWR), performed a site inspection for permit NCG500354 on July 7, 2021. The inspectors met with onsite representative David Callahan for the inspection. Mr. Callahan provided all documentation required and gave the inspectors a tour of the facility and how it operates. The facility has a boiler which blows down about once every 24 hours. An oxygen scavenger, a polymer, and a streamline agent are still used in the boiler water. MSDS were available on site, and a copy of the new permit from 2020 and COC were available on site. Mr. Callahan stated that after there were 2 exceedences for residual chlorine in 2017, they switched to using liquid chlorine in 2020 to keep these exceedences to a minimum. This has helped them stay within their limits since making this change. Boiler blowdown water is pH adjusted with sulfuric acid and is recirculated in a tank to allow for cooling and proper pH adjustment. They have a pH probe for process control on the addition of sulfuric acid. Monitoring requirements are done by EnviroChem and a copy of their lab certification was available on site. COD, pH, and temperature were analyzed, as well as residual chlorine at least 2x/year. The water is allowed to cool in the tank while the pH is adjusted prior to discharge in to a drain which has a tiered flow setup as well as a "pom pom" for additional oil absorption from stormwater runoff. Estimated flow is -1000 gal/day. Daily logs were available for discharging and they included the dates, start/stop times, initials of discharge operator, and pH. No foam or oil sheen was present in the drain on the water surface. Facility looks well maintained and records were complete. Page# DocuSign Envelope ID: 9BADD4E0-5AD8-41C7-88C0-F42162B50EFB Permit: NCG500354 Owner -Facility: Slurry Pavers- Morehead City Inspection Date: 07/07/2021 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ■ ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The facility is well maintained. They keep a daily log book that includes PH and start/stop times for pumping the boiler blowdown water. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ■ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ ■ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: The facility is located inside the State Port at Morehead City. ID's were used to perform background checks on inspectors. The inssectors were then signed in and escorted to the facility for inspection. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ❑ ❑ ■ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ❑ ❑ ■ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ■ ❑ operator on each shift? Is the ORC visitation log available and current? ❑ ❑ ■ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ■ ❑ Page# 3 DocuSign Envelope ID: 9BADD4E0-5AD8-41C7-88C0-F42162B50EFB Permit: NCG500354 Owner -Facility: Slurry Pavers- Morehead City Inspection Date: 07/07/2021 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Is the backup operator certified at one grade less or greater than the facility ❑ ❑ 0 ❑ classification? Is a copy of the current NPDES permit available on site? E ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? 0 ❑ ❑ ❑ Comment: This facility has permit NCG500354 general permit for boiler blowdown operations. Laboratory analysis were completed by EnviroChem which is a state certified lab. Records were available for at least than 5 years prior to present date. Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? kreTvki[•7►/_90I:1 ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Comment: 7.5hp 2 inch diameter discharge at 170GPM. On site representative states that they lower the levels by -1ft when discharging and estimates that amount to be-1000gal. On site representative also states that they discharge to the storm drain which is tiered for settlement and has a "Pom Porn" for added protection against oil/grease discharge. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ■ ❑ ❑ ❑ degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ❑ ■ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ ❑ Comment: Laboratory processing done by EnviroChem State Certified Lab. pH meter is located on site for process control. ChemTreat checks behind them 1x/month and they have an extra small lab on site for analyzing boiler water to ensure that only the amount of chemicals necessary are added. Page# 4