HomeMy WebLinkAboutWI0600068_Correspondence_20140313Rogers, Michael
From: Justin Ballard jjustin.ballard@cardno.com]
Sent: Thursday, March 13, 2014 4:08 PM
To: Rogers, Michael
Cc: Genna Olson
Subject: Signature Page for Permit WI0600068
Attachments: DC260003_20140313_Page5InjectionPermitW10600068RenewalApplication.pdf
Mr. Rogers,
Attached is the signature page for the renewal application per the voicemail you left with Genna Olson. Please let me
know if you need anything else. Thanks.
Justin C. Ballard, P.G. 1 Project Manager I ATC Associates of North Carolina, P.C. I Raleigh, NC
(919) 573-1196 direct I (252) 548-9191 mobile
2725 East Millbrook Road I Suite 121 I Raleigh, NC 27604
(919) 871-0999 tel I (919) 871-0335 fax 1 www.atcassociates.com
PLEASE NOTE: This message, including any attachments, may include privileged, confidential and/or inside information. Any
distribution or use of this communication by anyone other than the intended recipient is strictly prohibited and may be unlawful. If
you are not the intended recipient, please notify the sender by replying to this message and then delete it from your computer.
1
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Resources
Water Quality Programs
Pat McCrory Thomas A. Reeder John E. Skvarla, III
Governor Director Secretary
February 07, 2014
DSCA Site #26-0003 — Petitioner
Ms. Joyce W. Smith
DSCA Program - 1646 Mail Service Center
Raleigh, NC 27699-1646
Dear Ms. Smith:
Subject: Acknowledgement of
Application No. WI0600068
Smitty's Cleaners
In Situ Groundwater
Remediation Wells System
Wake County
The Water Quality Regional Operations Section (WQROS) acknowledges receipt of your permit
application and supporting documentation received on February 7, 2014. Your application package has
been assigned the number listed above, and the primary reviewer is Michael Rogers.
Central and Raleigh Regional Office staff will perform a detailed review of the provided
application, and may contact you with a request for additional information. To ensure maximum
efficiency in processing permit applications, the Water Quality Regional Operations Section (WQROS)
requests your assistance in providing a timely and complete response to any additional information
requests.
Please note that processing standard review permit applications may take as long as 60 to 90 days
after receipt of a complete application. If you have any questions, please contact
Michael Rogers at (919) 807-6406 or michael.rogers@ncdenr.gov.
Sincerely, n�a;t4iLf(-Fr)
for Debra J. Watts
Groundwater Protection Unit Supervisor
cc: Raleigh Regional Office, WQROS
Mr. Justin Ballard — ATC Associates of NC, P.C.- 2725 E. Millbrook Road, Raleigh, NC 27604
Mr. Young Bang — 722 Murray Hill Road, Fayetteville, NC 28303
Permit File WI0600068
WATER Iil1ALITY REGIONAL OPERATIONS SECTION
1636 M atService Center, Raleigh, North Carolina 27699-1636
Locationi12 N. Salisbury St, Raleigh, North Carolina 27604
Phone: 9-807-64641 FAX: 919-807-6496
Internet: IEp,llaortal.ncdenr.orglweblwalaps
An Equal feportunity \ Affirmative Acton Employer
A=.4_07A
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins Dee Freeman
Governor Director Secretary
February 28, 2011
Petitioner for DSCA Site 26-0003
DSCA Program
Mail Service Center 1646
Raleigh, North Carolina 27699-1646
Ref: Issuance of Injection Permit WI0600068
Smitty's Cleaners DSCA Site # 26-0003
Injection In situ Groundwater Remediation Wells (5I)
Fayetteville, Cumberland County, North Carolina.
Dear Petitioner:
In accordance with the application received on December 30, 2010, and the supporting data received January 25, 2011, we
are forwarding permit number WI0600068. This permit is to inject sodium permanganate and potassium permanganate to
remediate groundwater contaminated with dry cleaning solvents (tetrachloroethylene and daughter products) at the facility
referenced above. This permit shall be effective from the date of issuance until January 31, 2014, and shall be subject to
the conditions and limitations stated therein, including the requirement to submit a fmal project evaluation as stated in
PART VII — MONITORING AND REPORTING REQUIREMENTS. Please read the entire permit to ensure that you are
aware of all compliance requirements of the permit.
You will need to notify this office by telephone 48 hours prior to initiation of operation of the facility. In order to
continue uninterrupted legal use of the injection facility for the stated purpose, you must submit an application to renew
the permit 120 days prior to its expiration date. Please contact me at (919) 715-6162 or at david.goodrich@ncdenr.gov if
you have any questions about your permit.
Best Regards,
David Goodrich
Hydrogeologist
cc: Art Barnhardt, Fayetteville Regional Office
Justin C. Ballard, ATC Associates of North Carolina. PC, 2725 East Millbrook Road, Suite 121, Raleigh. NC 27604
Al Chapman, DWM Superfund Section. 1646 Mail Service Center, Raleigh, NC 27699-1646
Fayetteville Public Works Commission, P.O. Box 1089, Fayetteville. NC 28302
Buck Wilson, Cumberland County Health Department, Environmental Health Section, 1235 Ramsey Street,
Fayetteville, NC 28301
WI0600068 Permit File
AQUIFER. PROTECTION SECTION
1E36 Mail Service Center, Raleigh, North Carolina 27699-1636
Location: 2728 Capital Bowevard, Raleigh. North Carolina 27604
Phone: 919-733-3221 \ FAX 1 919 715-0588; FAX 2:819-715-6048 t Customer Sennce= 1-87 623-6748
Internet: www.ncwateraualitv.orq
One
N Orth Laroiin<<
Ar Ecuni vptonunn; '. Aff;rrnalive _mpbvE
Goodrich, David
From: Justin Ballard[justin.ballard@atcassociates.com]
Sent: Tuesday, January 25, 2011 8:33 AM
To: Goodrich, David
Cc: - genna.olson@atcassociates.com
Subject: Additional Information Request for Smitty's Cleaners Remediation Permit
Mr Goodrich:
Please disregard my email from yesterday. I accidently sent you the draft of my response. Please review the calculations
and measurements below in response to your email. Please let me know if you have any questions. Note that I
separated the shallow zone into two intervals. This was due to the onsite perched zone as referenced on Page 4 of the
application text.
-Based on the shallow zone hydraulic conductivity (K) value of 1.99 ft/day and an aquifer thickness of 6.24 ft (bottom of
perched zone = 25 ft and an average of depth to water for MW-2 (20.36 ft) and MW-5 (17.16 ft) = 18.76 ft), the
transmissivity value for the perched zone is 12.42 ft^2/day.
-Based on the shallow zone K value of 1.99 ft/day and an aquifer thickness of 23.39 ft (bottom of shallow zone screen
intervals = 55 ft and an average of depth to water for all offsite monitoring wells (i.e. wells not within the perched water
zone) = 31.61 ft), the transmissivity value for the shallow zone is 46.55 ft^2/day.
-Based on the deep zone K value of 2.6 ft/day and an aquifer thickness of 18.0 ft (deep zone screen intervals from
67 to 85 ft), the transmissivity value for the deep zone is 46.8 ft^2/day.
-Based on historical data for all onsite shallow monitoring wells, the shallowest depth to water measured to date in each
well is as follows:
MW-1: 17.93 ft
MW-2: 19.73 ft _
MW-3R: 17.47 ft
MW-4: 17.06 ft
This averages out to 18.05 ft.
Again, please let me know if you have any questions or if anything needs further clarification.
Justin C. Ballard, P.G. 1 Project Geologist I ATC Associates of North Carolina, P.C.
(919) 573-1196 direct I (252) 548-9191 mobile
2725 E. Millbrook Road 1 Suite 121 I Raleigh, North Carolina 27604
(919) 871-0999 1 (919) 871-0335 fax 1 www.atcassociates.com
From: Goodrich, David fmailto:david.goodrichencdenr.govj
Sent: Friday, January 07, 2011 8:58 AM
To: iustin.bailard(Tatcassociates.com
Subject: Additional Information Request for Smitty's Cleaners Remediation Permit
Mr. Ballard:
The Aquifer Protection Section is reviewing the injection well application for Smitty's Cleaners in Fayetteville, NC.
To continue my review, I need to obtain transmissivity estimates for the shallow and deep groundwater zones at the
proposed
1
injection site, as required underSect's.. '(B)(3) on Page 5 of the UIC-51/5TApplics`r-6n Form. I also need to know the
depth to the mean seasonal high water table in the proposed injection area, as required under Section V(B)(4).
Please contact my office at (919) 715-6162 if you have any questions regarding these requests.
Sincerely,
David Goodrich
Aquifer Protection Section Central Office
2
Goodrich, David
'Viet _7h
fz- 1s
To:
Subject:
Mr. Ballard:
justin.ballard@atcassociates.com
Additional Information Request for Smitty's Cleaners Remediation Permit
The Aquifer Protection Section is reviewing the injection well application for Smitty's Cleaners in Fayetteville, NC.
To continue my review, I need to obtain transmissivity estimates for the shallow and deep groundwater zones at the
proposed
injection site, as required under Section V(B)(3) on Page 5 of the UIC-51/5T Application Form. I also need to know the
depth to the mean seasonal high water table in the proposed injection area, as required under Section V(B)(4).
Please contact my office at (919) 715-6162 if you have any questions regarding these requests.
Sincerely,
David Goodrich
Aquifer Protection Section Central Office
/77Ar
1
ATA
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins Dee Freeman
Governor Director Secretary
January 5, 2011
Joyce W. Smith
Petitioner for DSCA Site 26-0003
Mail Service Center 1646
Raleigh. NC 27699
Subject: Acknowledgement of Application No. WI0600068
Smitty's Cleaners DSCA Site # 26-0003
Injection In situ Groundwater Remediation Well (5I)
Cumberland
Dear Ms. Smith:
The Aquifer Protection Section of the Division of Water Quality (Division) acknowledges receipt of your permit application and
supporting materials on December 30, 2010. This application package has been assigned the number listed above and will be reviewed
by David Goodrich.
The reviewer will perform a detailed review and contact you with a request for additional information if necessary. To ensure the
maximum efficiency in processing permit applications, the Division requests your assistance in providing a timely and complete
response to any additional information requests.
Please be aware that the Division's Regional Office, copied below, must provide recommendations prior to final action by the
Division. Please also note at this time, processing permit applications can take as long as 60 - 90 days after receipt of a complete
application.
If you have any questions, please contact David Goodrich at 919-715-6162, or via e-mail at david.goodrichCncdenr.gov. If the
reviewer is unavailable, you may leave a message, and they will respond promptly.
PLEASE REFER TO THE ABOVE APPLICATION NUMBER WHEN MAKING INQUIRIES ON THIS PROJECT.
Sincerely,
kov\Q_
for Debra J. Watts
Supervisor
cc: Fayetteville Regional Office, Aquifer Protection Section
ATC Associates NC (Justin C. Ballard, P.G. - 2725 East Millbrook Road, Suite 121, Raleigh, NC 27604)
Permit Application File WI0600068
AQU?FER PP. TECTION SECTION
1636 Mai! Service Center, Raleigh, North Carolina 27699-1636
Location. 2728 Capital Boulevard. Raleigh, North Carolina 27604
Pnone: 919-733-3221 \ FAX 1 919.715-0588, FAX 2. 919-715-60481 Customer Service: 1-877-623-6748
Internet: www.ncwateroualitv.orq
fir. Equal Coc.crtunity Affirmative Acton Eraviov@;'
On,
Nortn Carolina
,2aturatfi