HomeMy WebLinkAboutWI0700473_Correspondence_20180911ROY COOPER Govontcr MICHAEL S. REGAN Secretary LINDA CULPEPPER lMtertm Director Michael Colson and Gail Dickinson 120 Dogwood Drive Camden, North Carolina 27921 NORTH CAROLINA Environmental Quality September 11, 2018 SUBJECT: Groundwater Sampling Results UIC Permit No. WI0700473 Issued to Michael Colson and Gail Dickinson Camden, Camden County, North Carolina Dear Mr. Colson and Ms. Dickinson: .ECEIVEDINCDEQID' SEP 13 2013 Water Quality Regional Operations Section Staff from the Washington Regional Office of the Water Quality Regional Operations Section collected samples of the influent (supply well) and effluent (injection well) from your geothermal heat pump system on July 31, 2018. The samples were analyzed for metals, nutrients; anti other inorganic constituents by the Division of Water Resources laboratory. A summary table of the analytical results, as well as the laboratory reports, field sampling forms, and defmitions of laboratory data qualifiers are attached to this letter. The following two constituents were detected above state groundwater standards in both samples from your system: Parameter Units NC Groundwater Standard Results Total Coliform Colony Forming Units per 100 milliliters (CFU/100m1) 1 6 (supply well -influent) 18 (injection welt -effluent) pH Standard Units (s.u.) 6.5 to 8.5 6 (supply well -influent) 6 (injection well -effluent) These exceedances should not affect the use of the wells for your geothermal heat pump system; however, it is recommended before using the water from these wells for personal consumption that you consult with Albemarle Regional Health Services (local health agency). 1:1717:M North Carolina Department of Environmental Quality (Division of Water Resources - Washington Regional Office 943 Washington Square Mall, Washington, North Carolina 27889 Michael Colson and Gail Dickinson September 11, 2018 . Page 2 of 2 In addition, the following constituent exhibited an increase in concentration between the influent (supply well) and effluent (injection well): Parameter Units NC Groundwater Standard Results Copper ug/L 1000 19 (supply well -influent) 93 (injection well -effluent) While these concentrations of copper are still below state groundwater standards, these results may indicate that your geothermal heat pump system is having an effect on the groundwater flowing through the system. This information being provided to help you operate the system in the future. If you have any questions regarding the sampling results or your permit, please feel. free to contact me at (252) 948-3849. Sincerely, Dwight Randy Sipe, P.C6i., Hydrogeologist Water Quality Regional Operations Section Division of Water Resources, NCDEQ Attachments cc: Shristi Shrestha — DWR Groundwater Protection Unit, Central Office Albemarle Regional Health Services WaRO North Carolina Department of Environmental Quality (Division of Water Resources - Washington Regional Office 943 Washington Square Mall, Washington, North Carolina 27889 252-946-6481 NC DIVISION OF WATER RESOURCES LABORATORY ANALYTICAL RESULTS GEOTHERMAL HEATING/COOLING RETURN WELL PERMIT NO.: WI0700473 PERMITTEE(S): Michael Colson & Gail Dickinson SAMPLE COLLECTION DATE: 7/31/18 tCEIVEDINCDECJW, SEP 1 3 2018 Water Quality Region Operations Section Parameter Fecal Coliform Total Coliform Total Dissolved Solids Chloride, CI Fluoride, FL Sulfate, SO4 units CFU1100m1 CFU/100m1 mg/L mg/L mg/L mg/L NC GWS and/or EPA Standard NC GWS = < 1 NC GWS = < 1 NC GWS = 500 NC GWS = 250 NC GWS = 2 NC GWS = 250 EPA SDWS = 500 EPA SDWS = 250 EPA PDWS = 4.0 EPA SDWS = 250 Influent Sample Results <1 6 148 36 <0.4 7.4 Effluent Sample Results <1 18 140 36 <0.4 7.6 Parameter Nitrate + Nitrite Nitrite Hardness as CaCO3 (by Calculation) * Aluminum, Al Arsenic, As Calcium, Ca units mglL as N mg/L as N mg!L as CaCO3 pglL pg/L mg/L NC GWS and/or EPA Standard NC GWS = 11 NC GWS = 1 NS NS NC GWS = 10 NS EPA PDWS = 11 EPA PDWS = 1 EPA SDWS = 50 to 200 EPA PDWS = 10 Influent Sample Results 1.2 <0.01 54 <50 <2.0 12 Effluent Sample Results 1.2 <0.01 53 <50 <2.0 12 Parameter Chromium, Cr Copper, Cu Iron, Fe Potassium, K Magnesium, Mg Manganese, Mn units pg/L pg1L pg/L mg/L mg/L pg/L NC GWS and/or EPA Standard NC GWS = 10 NC GWS = 1000 NC GWS = 300 NS NS NC GWS = 50 EPA PDWS = 100 EPA SDWS = 1000; PDWS = 1300 EPA SDWS = 300 EPA SOWS = 50 Influent Sample Results <5.0 19 <50 1.8 5.8 32 Effluent Sample Results <5.0 93 <50 1.8 5.5 31 Parameter Sodium, Na Nickel, Ni Lead, Pb Zinc, Zn pH (field) units mg/L pg/L pg/L pg/L units NC GWS and/or EPA Standard NS NC GWS = 100 NC GWS = 15 NC GWS = 1000 NC GWS = 6.5-8.5 EPA PDWS = 15 EPA SDWS = 5000 EPA SDWS = 6.5 to 8.5 Influent Sample Results 18 4.2 <2.0 25 6 Effluent Sample Results 19 8.4 <2.0 31 6 NC GWS = North Carolina Groundwater Standards per 15A NCAC 2L .0200 EPA PDWS = Environmental Protection Agency Primary Drinking Water Standards EPA SDWS = Environmental Protection Agency Secondary Drinking Water Standards NS = No Standard ' Calculation performed by WaRO AC53590 North Carolina Division of Water Resources Water Sciences COLSON GEOTHERMAL �'r h - tus kt-) CAMDEN Collector. R SIPE WARD Report To WARD Loc. Descr.: County: Region: River Basin Emergency COC Yes/No Collect Date' 07/31/2018 Collect Time: 10_30 Sample Depth VlsitlD Location ID: Priority Sample Matrix: Loc. Type: Final Report WARO NLC COMPLIANCE GROUNDWATER . Section Laboratory Results Sample ID: AC53590 PO Number # Date Received: Tme Received: Labworks LoginlD Delivery Method Final Report Date' Report Print Dater 08/01/2018 08_15 TASCENZOI NC Courier 8127118 08/28/2018 If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. Result Method Analysis Units CAS # Analvte Name PQL Qualifier Reference Date Validated by LAB Sample temperature at receipt by lab 2.3 °c 8/2/18 CGREEN Coliform, MF Fecal in liquid 1 MIC 1 B2,Q1 CFUnooml SM 9222 D-1997 8/1/18 ESTAFFORD1 Coliform, MF Total in liquid 6 Q1 CFU/10om1 SM 9222 B-1997 ' 8/1/18 ESTAFFORDI Nitrate as N in liquid 0.02 NUT 1.2 mg/L as N EPA353.2 REV 2 8/2/18 CGREEN Nitrite as N in liquid 0.01 0.01 U mg/L as N EPA353.2 REV 2 8/1/18 CGREEN NO2+NO3 as N in liquid 0.02 1.2 mg/L as N EPA353.2 REV 2 8/2/18 CGREEN Bromide 0.4 WET 0.4 U mg/L EPA 300.0 rev2.1 8/1/18 CGREEN Chloride 1.0 36 mg/L • EPA 300.0 rev2.1 8/1/1 B CGREEN • Fluoride 0.4 0.4 U mg/L EPA 300.0 rev2.1 8/1/18 CGREEN Sulfate 2.0 1 7.4 mg/L EPA 300.0 rev2.1 8/1/18 CGREEN Total Dissolved Solids in liquid 148 mg/L SM 2540 C-1997 8/3/18 CGREEN MET AI by ICP 50 50 U ug/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORD1 As by ICPMS 2.0 2.0 U ug/L EPA 200.8 Rev5.4 8/9/18 ESTAFFORDI Ca by ICP - 0.10 12 mg/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORDI Cr by ICPMS 5.0 5.0 U ug/L EPA200.8 Rev5.4 8/9/18 ESTAFFORDI Cu by ICPMS 2.0 19 ug/L EPA200.8 Rev5.4 8/9/18 ESTAFFORD1 Fe by ICP 50 50 U ug/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORD1 K by ICP 0.10 1.8 mg/L EPA200.7 Rev4.4 8/10/18 ESTAFFORD1 Mg by ICP 0.10 5.8 mg/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORD1 Mn by ICP 10 .32 ug/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORDI Na by ICP 0.10 18 mg/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORDI Ni by ICPMS 2.0 4.2 ug/L EPA200.8 Rev5.4 8/9/18 ESTAFFORDI Pb by ICPMS 2.0 2.0 U ug/L EPA200.8 Rev5.4 8/9/18 ESTAFFORDI Zn by ICPMS 10 25 ug/L EPA200.8 Rev5.4 8/9/18 ESTAFFORDI WSS Chemistry Laboratory» 1623 Mall Service Center, Raleigh, NC 27699.1623 (919) 733-3908 "Not Detected" or "Lr does not indicate the sample is analyte free but that the analyte Is not detected at or above the POL. Page 1 of 3 WC 'D'NWR. La6oratorySection R suits/Sampee Comments/Quarter (Definitions Sample ID: AC53590 CAS # Analvte Name PQL MIC:Total Coliform-Q1-Sample exceeded holding lime prior to receipt aflab. MIC:Fecal Coliform-B2-Counts from all filters = 0. MIC:Fecal Coliform-0i-Sample exceeded holding time prior to receipt at lab. Result/ Qualifier Sample Comments Units Method Reference Analysis Date Validated by, NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to cal( B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 ml that would have been B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle: B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu, BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea: G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg& and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 t 30.5 mg/L. G6 BOD-The calculated seed correction exceeded the range of 0.6 to 1.0 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated fol G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. WSS Chemistry Laboratory» 1623 Mall Service Center, Raleigh, NC 27699.1623 (919) 733-3906 "Not Detected" or"U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 2 of 3 NC tD'Wht, La6oratary Section Rgsufts/Sample Comments/Quatfrer'Definitions Sample ID: AC53590 CAS # Analyte Name PQL- Result/ Qualifier Units Method Reference Analysis Date Validated by J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperlychemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate. ' J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J10 Unidentified peak; estimated value. J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. M Sample and duplicate results are "out of control". The sample is non -homogenous (e.g., VOA soil). The reported value is the lower N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of z N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. P Elevated PQL* due to matrix interference and/or sample dilution. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical qualifie ten limit*. The number value repot X1 Sample not screened for this compound. . X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed-lati error. ✓ Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s Y Elevated PQL* due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tl WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-908 "Not Detected" or"U" does not Indicate the sample Is analyte free but that the analyte is not detected at or above the PCL. Page 3 of 3 North Carolina Division of Water Resources Central Laboratory (Water Sciences Section) WaterEP 13 2O18 y Visit ID: QOeVit Water Sample Collection & Subm� r4aitair►I Taglnfluen ID'- Location Description: W10700473 -Colson Geothermal Return Well ri i Location Code: Influent jy 4-- Ai ('e— 11 I1 It unlit iuuun AC53590 Date Rec 8/1/2018 08:15 t` - -County: Camden Collector, R Sipe Priority: ❑Ambient ❑ Routine .- ( • Water Matrix: ❑ Surface _ - _ . - Location Type: : ❑River/Stream ❑Lake ❑ Estuary III Canal Stormwater ❑Monitoring Well ❑Water Supply ❑Effluent ❑Influent ❑ Field Blank ❑Trip Blank ❑ Fdter BTemperature3 DWR"Region: = (based on county) WaRO DWR-Office: (or agency name) WOROS - WaRO Time Received: �. 1 Received By . River Basin: - Pasquotank Date: 7/31/2018 to owner Delivery Method: Htnd elivery - ❑Other ✓ Compliance Ground Notes. . Jlme: - 10 30 AM coc Emergency ❑QA ❑Waste ❑❑ Sompliny ,- Mo: Grab UC:omposite - Temperature ('C) Tempeon Arrival, Chlorinated De chlorinated in Field . Blank ethd❑Other ❑ Solution Dissolved analysts F11ter'OIS" ❑ Filtered in Field in check -boxes for parambters r Sample Depth: NIA -, .- . Other Geotherm Supply Well -Collectoi•'sComments: sample collected at spigot at well head • Microbiology Parameters: . - MBAS (surfactants) mg/L -Metals Parameters: -� . - Tin (Sn) µg/L Acidity, as CaCO3, to pH 4 5/8 3 mg/L Oil and Grease, HEM, Total Recoverable mg/L X Aluminum (Al) pg/L Titanium (Ti) pg/L Alkalinity, as CaCO3, to pH 4 5/8 3 mg/L Phenols, Total Recoverable pg/L Antimony (Sh) µg/L Vanadium (V) pg/L SOD Biochemical oxygen Demand, 5-day mg/L Residue Total (Total Solids) mg/L X Arsenic (As) pg/L X Zinc (Zn) nit. cBOD Carbonaceous BOD, 5-day mg/L Residue Volatile/Fixed, Total mg/L Barium (Ba) µg/L X Cohform Fecal MF /100m1 Residue Suspended (Suspended Sohds) mg/L Beryllium (Be) pg/L Boron (8), Total pg/L X Cohform Total MF /100m1 Residue Volatile/Fixed, Suspended mg/L Cadmium (Cd) pg/L Mercury 1631, low-level ng/L Coliform Tube Fecal /100m1 X TDS - Total Dissolved Solids mg/L x Calcium (Ca) mg/L Cohform Tube Total /100m1 Silica mg/L X Chromium (Cr), Total pg/L -- Organics Parameters: Specific Conductance, at 25 °C umhos/cm Sulfide - mg/L Cobalt (Co) pg/L Acid Herbicides TOC - Total Organic Carbon mg/L Tannin & Lignrn mg/L X Copper (Cu) pg/L Organochlonne Pesticides Turbidity NTU X Iron (Fe) Ng/L Organonitrogen Pesticides _ Other Parameters: --- - X Lead (Pb) pg/L. Organophosphorus Pesticides -, Wet Che(nistnjr Parameters: - - pH s u Lithium (u) µg/L PCBs (polychlorinated biphenyls) Bromide mg/L Hardness, Total as CaCO3 - by titration mg/L X Magnesium (Mg) mg/L X Chloride mg/L X Manganese (Mn) pg/L Semi -Volatile Organics (BNAs) Fluoride mg/L Mercury (Hg) pg/L TPH Diesel Range Sulfate mg/L Nutrients Parameters: - 't Molybdenum (Mo) µg/L Chlorophyll a pg/L Ammonia as N (NH3-N) mg/L X Nickel (NI) pg/L Volatile Organics (VOA) Color ADMI c u X Nitrate -Nitrite as N (NO3+NO2-N) Mg/I. X Potassium (K) mg/L Color Platinum Cobalt c u Total Kleldahl Nitrogen as N (TKN) mg/L Selenium (Se) pg/L TPH Gasoline Range COD Chemical Oxygen Demand mg/L Total Phosphorus as P (TP) mg/L Silver (Ag) pg/L Cyanide, Total mg/L X Nitrite as N (NO2-N) mg/L X Sodium (Na) mg/L . Biological: - 1 _1 Formaldehyde mg/L Nitrate as N (NO3-N calculated) mg/L Strontium (Sr) pg/L Phytoplankton / Algae Hexavalent Chromium (Cr6+) mg/L Orthophosphate as P (PO4) mg/L Thallium (TI) pg/L LAB COMMENTS • Field Paiamelers(apnonol): Water Temp (°C). -- pH (s u ). 6 Dissolved Oxygen (ppm)' •Conductnrtty (µmhos/cm} Salinity (ppt) evision 2/06/2015 AC53589 Loc. Descr.: County: Region: River Basin Emergency COC Yes/No North Carolina Division of Water Resou,(ces Water Sciences Section Laboratory Results ` COLSON GEOTHERMAL RETURN WELL E\ l (me iff CAMDEN Collector R SIPE Vis81D WARO PAS Report To Collect Date Collect Time: Sample Depth WARO 07 31 112018 10:20 Location ID: Priority Sample Matrix: Loc. Type: Final Report WARO NLC COMPLIANCE GROUNDWATER Other. Geothermal Well Sample ID: PO Number # Date Received: Time Received: Labwarks LogintD Delivery Method Final Report Date Report Print Date AC53589 08101/2018 08_15 TASCENZOI NC Courier 8127/18 08/26/2018 If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. Result/ CAS # Analvte Name PQL Qualifier LAB Sample temperature at receipt by lab 2.3 Units •C Method Analysis Reference Date 8/1/18 Validated by MSWIFT Coliform, MF Fecal in liquid MIC 1 Q1 CFU/100m1 SM 9222 D-1997 8/1/18 ESTAFFORD1 Coliform, MF Total in liquid 18 Q1 CFU/100m1 SM 9222 B-1997 8/1/18 ESTAFFORDI NUT Nitrate as N in liquid 0.02 1.2 mg/L as N EPA 353.2 REV 2 8/2/18 CGREEN Nitrite as N in liquid 0.01 0.01 U mg/L as N EPA 353.2 REV 2 8/1/18 CGREEN NO2+NO3 as N in liquid 0.02 1.2 mg/L as N EPA 353.2 REV 2 8/2/18 CGREEN Bromide WET 0.4 0.4 U mg/L EPA 300.0 rev2.1 8/1/18 CGREEN Chloride 1.0 36 mg/L EPA 300.0 rev2.1 8/1/18 CGREEN Fluoride 0.4 0.4 U mg/L EPA 300.0 rev2.1 8/1/18 CGREEN Sulfate 2.0 7.6 mg/L EPA 300.0 rev2.1 8/1/18 CGREEN Total Dissolved Solids in liquid 12 140 mg/L SM 2540 C-1997 8/3/18 CGREEN MET Al by 1CF' 50 50 U ug/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORDI As by ICPMS 2.0 2.0 U ug/L. EPA 200.8 Rev5.4 8/9/18 ESTAFFORDI Ca by ICP 0.10 12 mg/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORDI Cr by ICPMS 5.0 5.0 U ug/L EPA 200.8 Rev5.4 8/21/18 ESTAFFOR01 Cu by ICPMS 2.0 93 ug/L EPA 200.8 Rev5.4 8/21/18 ESTAFFORD1 Fe by ICP 50 • .50 U ug/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORDI K by ICP 0.10 1.8 mg/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORD1 Mg by ICP 0.10 5.6 mg/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORD1 Mn by ICP 10 31 ug/L EPA200.7 Rev4.4 - 8/10/18 ESTAFFORD1 Na by ICP 0.10 19 mg/L EPA 200.7 Rev4.4 8/10/18 ESTAFFORD1 Ni by ICPMS 2.0 8.4 ug/L EPA 200.8 Rev5.4 8/21/18 ESTAFFORDI Pb by ICPMS 2.0 2.0 U ug/L EPA 200.8 Rev5.4 8/9/18 ESTAFFORD1 Zn by ICPMS 10 31 ug/L EPA200.8 Rev5.4 8/9/18 ESTAFFORD1 WSS Chemistry Laboratory» 1623 Mall Service Center, Raleigh, NC 27699-1623 (919) 733.3908 "Not Detected" or "U" does not Indicate the sample is analyte free but that the analyte is not detected at or above the POL. Page 1 of 3 TIC (MAX Laboratory Section 7fysufts/Sample Comments/Quafficr'Defmitions Sample ID: AC53589 CAS # Analvte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by Sample Comments MIC:Total Coliform-Q1Sample exceeded holding time prior to receipt at lab. MIC:Fecal Coliform-Q1-Sample exceeded holding time prior to receiptet lab. NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to call B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 ml that would have been B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smaller B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non -conform or non-enterococcus growth present. In this cc BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" vale BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea: G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de G5 BOD.-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G6 BOD-The calculated seed correction exceeded the range of 9.6 to 1.0 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions St. The reported value is an estimated greater than value and is calculated foi G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. WSS Chemistry Laboratory» 1623 Mall Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or"U" does not Indicate the sample is analyte free but that the analyte is not detected at or above the POL. Page 2 of 3 9%/Ca»t4 Ga6oratorySection 4su(ts/Sample Comments/Quafrfsr'Definitionr Sample ID: AC53589 CAS # Analvte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by J2 The reported value failed to meet the establiatiedguality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6°C) during transport ornot verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate. - J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J10 Unidentified peak; estimated value. J11 The reported value is determined by a one -point estimation -rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. M Sample and duplicate results are "out of control". The sample is non -homogenous (e.g., VOA soil). The reported value is the lower ' N1 Presumptive evidence and estimated value. The component has been tentatively identified base on massspectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of z N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 - This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. P Elevated PQL* due to matrix interference and/or sample dilution. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit. The number value repot X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab -.error. ✓ Indicates the analyte was detected in both the-'sartiple and the associated method blank. Note: The value in the blank shall not be s Y Elevated PQL* due to insufficient sample site: .-:' Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. " U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tl • WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699.1823 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PDL. Page 3 of 3 North Carolina Division af Water Resources Central Laboratory (Water Sciences Section) Water Sample Collection Submittal Form I visut: (ophono0 IL EfFluen � ' LAB COMMENTS : Field Parametets(opdano6: Water Temp (°C)• -ri p1T(s.u) 6 Dissolved Oxygen (ppm), _ Conductivity (pmhos/cm). - - • Salinity (opt). Revision 2/06/2015