Loading...
HomeMy WebLinkAboutWI0700012_Monitoring (Report)_20110211PotashCorp' Helping Nature Provide February 11, 2011 Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina, 27699 Attn: Information Management CERTIFIED MAIL Subject: Underground injection Control Program Quarterly Groundwater Monitoring Report November 2010 — January 2011 Injection Well Permit #WI0700012 Tank Farm Remedial Action System Beaufort Co. Dear Qi: Please find the subject groundwater monitoring report attached. This includes the sampling and reporting requirements of the above referenced permit, Part V, Section B 1 as well as the reporting requirements of the overall Tank Farm Remedial Action Plan. Enclosed are: a) Form GW-59 for injection well CIW7, Form GW-59 for the WLCT and Form GW-59 for monitor well MWTFICR, b) piezometer level monitoring field sheet, and c) the summary operational and maintenance report. Note: Inadequate head was available in CIW7 during the sampling event. The injection well water was sampled upstream from the WLCT. Historical sampling shows that data collected from CIW7 and WLCT are identical. Please do not hesitate to contact me at (252) 322-8283 if you have any questions regarding this information. Sincerely, 16c&i/tALO D. Daniel Winstead III Environmental Engineer PCS Phosphate Attachments RECEIVED /DENR/DWQ Aquifer Prntaetion eetion MAR 1 4 2011 1530 NC Hwy 306 South, Aurora, NC USA 27806 T (252) 322-4111 PCS Phosphate I www.potashcorp.com pc: Will Hart — Aquifer Protection DWQ, WaRO (w/ attachments) R. M. Smith/12-07-02 (w/ attachments) Mike Brom (w/ attachments) Jeremy Pierce (w/ attachments) R. B. Lee (w/ attachments) Total Two Copies Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina, 27699 Attn: Information Management H:\Reports\2011\Quarterly\TFRAS Report Fourth Quarter 2010.docx 2 GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORTING FORM FACILITY INFORMATION Facilty Name: PCS PHOSPHATE CO., INC. - Aurora Division Permit Name (if different): Facility Addresss: 1530 NC Hwy 306 South Aurora, NC 27806 County: Beaufort Contact Person: Jack H. Taylor, Jr. Telephone: (252)322-8155 Well Locations/Site Name: Tank Farm No. of Wells to be Sampled 3 Well Identification Number (from Permit): CIW-7 Well Depth: 48.00 ft. Well Diamter: 4 inch Screened Interval: 31.00 ft. to 45.25 ft. Depth to Water Level: N/A ft. below measuring point. Measuring Point is N/A ft above land surface. GALLONS of water pumped/bailed before sampling: For Groundwater Treatment Sys ems Check One: Influent (98) Effluent (99) CONTINUOUS Field Analysis: pH N/A , Specific Conductance N/A uMhos Temp. N/A oC. Odor NONE Appearance: CLEAR Mail Original to: DIVISION OF WATER QUALITY GROUNDWATER SECTION -PERMITS AND COMPLIANCE UNIT P.O. BOX 29578 RALEIGH, NC 27626-0578 Phone: (919)733-3221 PERMIT #: WI0700012 EXPIRATION DATE: Non -Discharge UIC X NPDES TYPE OF PERMITTED OPERATION BEING MONITORED Lagoon Spray Field X Remediation : 01/31/13 Remediation: Infiltration Gallery Rotary Distributor Land Application of Sludge Other Note: Values should reflect dissolved and colloidal concentrations Date sample collected: 1/11/2011 Date sample analyzed: Laboratory Name: PCS PHOSPHATE 1/11/2011 to 1/11/2011 Certification No(s) 330 PARAMETERS: (Samples for metals were collected unfiltered COD Coliform: MF Fecal Coliform: MF Total N/A mg/I Nitrite (NO2 as N) N/A /100m1 Nitrate (NOs as N) Yes n/a No and field acidified N/A mg/I Ni - Nickel N/A /100m1 Phosphorus: Total as P (Note: Use MPN method for highly turbid samples) Orthophosphate Dissolved Solids: Total N/A mg/I Al A)imir)m pH (when analyzed) N/A units Ba TOC N/A mg/I Ca Chloride Arsenic Grease and Oils N/A mg/I Cd- N/A mg/I N/A mg/I Phenol N/A mg/I Sulfate Specific Conductance Total Ammonia TKN as N Chromium: Total Cu - Copper Fe - Iron N/A mg/1 Hg - Mercury N/A uMhos K- Potassium N/A mg/I Mg - Magnesium N/A mg/I Mn - Manganese N/A mg/I Pb - Lead N/A mg/I -Zn - Zinc is Nitrogen Yes n/E No ) N/A mg/I N/A ug/I N/A ug/I N/A ug/I N/A N/A N/A fy Compounds and Concentration Units) ide MIBK Ag - Silver Se- Selenium Sodium N/A N/A N/A N/A N/A N/A ug/I Organics: (GC, GC/MS, N/A ug/I (Specify test method #. N/A ug/I Report attached? Yes N/A ug/I VOC N/A ug/I HPLC) Attach lab report.) (1) No X : method# • method# method# ug/I ug/I ug/I mg/I mg/I ug/I ug/I ug/I ug/I (2) I certify that, to the best of my knowledge and belief, the information submitted in this report is true, accurate, and complete, and that the laboratory analytical data was produced using approved methods of analysis by a North Carolina DWQ (formerly DEM) certified laboratory. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisionment for knowing violations. NOTE: COULD NOT INCREASE TO SAMPLING LEVEL. FEB 1 5 2011 Y SECTION or' ocessing Unit GW-59 Rev 4/98 Ross M. Smith - Manager, Environmental Affairs , �P�j rm ee of horizesi gent) Name and Title - Please type or print RECEIVED 1 DENR 1 Signature of Permutes (or Authorized Agent) (Date) Aquifer Prottzetion Section MAR 14 2011 GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORTING FORM FACILITY INFORMATION Facilty Name: PCS PHOSPHATE CO., INC. - Aurora Division Permit Name (if different): Facility Addresss: 1530 NC Hwy 306 South Aurora, NC 27806 County: Beaufort Contact Person: Jack H. Taylor, Jr. Telephone: (252)322-8155 Well Locations/Site Name: Tank Farm No. of Wells to be Sampled 3 Well Identification Number (from Permit): WLCT Well Depth: N/A ft. Well Diamter: N/A Screened Interval: N/A ft. to N/A ft. Depth to Water Level: N/A ft. below measuring point. Measuring Point is N/A ft above land surface. GALLONS of water pumped/bailed before sampling: For Groundwater Treatment Systems Check One: Influent (98) Effluent (99) CONTINUOUS Field Analysis: pH 7.0 , Specific Conductance 559 uMhos Temp. 15.8 oC, Odor NONE Appearance: CLEAR Mail Original to: DIVISION OF WATER QUALITY GROUNDWATER SECTION -PERMITS AND COMPLIANCE UNIT P.O. BOX 29578 RALEIGH, NC 27626-0578 Phone: (919)733-3221 PERMIT #: WI0700012 Non -Discharge NPDES EXPIRATION DATE: UIC X 01 /31 /13 TYPE OF PERMITTED OPERATION BEING MONITORED Lagoon Remediation: Infiltration Gallery Spray Field X Remediation : Rotary Distributor Land Application of Sludge Other Note: Values should reflect dissolved and colloidal concentrations Date sample collected: Date sample analyzed: Laboratory Name: Certification No(s) 1/11/2011 1/11/2011 to 1/12/2011 PCS PHOSPHATE 330 10 PARAMETERS: COD (Samples for metals were collected unfiltered N/A mg/I Coliform: MF Fecal N/A /100m1 Coliform: MF Total <1.0 /100m1 (Note: Use MPN method for highly turbid samples) Dissolved Solids: Total pH (when analyzed) TOC Chloride Arsenic N/A N/A N/A N/A N/A Grease and Oils Phenol Sulfate Specific Conductance Total Ammonia TKN as N N/A N/A N/A N/A N/A N/A mg/1 units mg/I mg/I mg/I mg/I mg/I mg/I uMhos mg/I mg/I Nitrite (NO2 as N) Nitrate (NO3 as N) Yes n/a Phosphorus: Total as P Orthophosphate Al - Aluminum Ba - Barium Ca - Calcium Cd- Cadmium Chromium: Total Cu - Copper Fe - Iron Hg - Mercury K- Potassium Mg - Magnesium Mn - Manganese No and field acidified Yes n/k No ) N/A mg/I Ni - Nickel N/A ug/I N/A ug/I N/A ug/I mg/I N/A ug/I Other (Specify Compounds and Concentration Units) N/A ug/I Fluoride N/A mg/I N/A ug/I MIBK N/A ug/I N/A ug/I Ag - Silver N/A ug/I N/A ug/I N/A ug/I N/A ug/I Organics: (GC, GC/MS, HPLC) N/A ug/I (Specify test method #. Attach lab report.) N/A ug/l Report attached? Yes (1) No X (2) N/A ug/I VOC method# N/A mg/I Pb - Lead N/A mg/I Zn - Zinc N/A mg/I Ammonia Nitrogen N/A ug/I N/A ug/I N/A ug/I Se- Selenium Sodium : method# method# I certify that, to the best of my knowledge and belief, the information submitted in this report is true, accurate, and complete, and that the laboratory analytical data was produced using approved methods of analysis by a North Carolina DWQ (formerly DEM) certified laboratory. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisionment for knowing violations. NOTE: GW-59 Rev 4/98 Ross M. Smith - Manager, Environmental Affairs Permittee (of Author d A ent Name and Title - Please type or print .D,, s 2/0 zo r Sign,�ps ure of Permittee (or Authorized Agent) (Date) GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORTING FORM FACILITY INFORMATION Facilty Name: PCS PHOSPHATE CO., INC. - Aurora Division Permit Name (if different): Facility Addresss: 1530 NC Hwy 306 South Aurora, NC 27806 County: Beaufort Contact Person: Jack H. Taylor, Jr. Telephone: (252)322-8155 Well Locations/Site Name: Tank Farm No. of Wells to be Sampled 3 Well Identification Number (from Permit): MWTF1-CR Well Depth: 42.00 ft. Well Diamter: 2 inch Screened Interval: 38.70 ft. to 40.70 ft. Depth to Water Level: 23.40 ft. below measuring point. Measuring Point is 3.95 ft above land surface. MILILITERS of water pumped/bailed before sampling: 3000 For Groundwater Treatment Systems Check One: Influent (98) Effluent (99) Field Analysis: pH 6.9 , Specific Conductance 605 uMhos Temp. 15.5 oC, Odor NONE Appearance: CLEAR Mail Original to: DIVISION OF WATER QUALITY GROUNDWATER SECTION -PERMITS AND COMPLIANCE UNIT P.O. BOX 29578 RALEIGH, NC 27626-0578 Phone: (919)733-3221 PERMIT #: WI0700012 Non -Discharge NPDES EXPIRATION DATE: 01/31/13 UIC X TYPE OF PERMITTED OPERATION BEING MONITORED Lagoon Remediation: Infiltration Gallery Spray Field X Remediation : Rotary Distributor Land Application of Sludge Other Note: Values should reflect dissolved and colloidal concentrations Date sample collected: 1/11/2011 Date sample analyzed: Laboratory Name: 1/11/2011 to 1/12/2011 PCS PHOSPHATE Certification No(s) 330 10 PARAMETERS: (Samples for metals COD Coliform: MF Fecal Coliform: MF Total N/A N/A <1.0 were collected mg/I /100m1 /100m1 (Note: Use MPN method for highly turbid samples) Dissolved Solids: Total pH (when analyzed) TOC Chloride Arsenic Grease and Oils Phenol Sulfate Specific Conductance Total Ammonia TKN as N unfiltered Yes n/a Nitrite (NO2 as N) Nitrate (NO3 as N) Phosphorus: Total as P Orthophosphate N/A mg/I Al - Aluminum N/A units Ba - Barium N/A mg/I Ca - Calcium N/A mg/I Cd- Cadmium N/A mg/I Chromium: Total N/A mg/I Cu - Copper N/A mg/I Fe - Iron N/A mg/I Hg - Mercury N/A uMhos K- Potassium N/A mg/I Mg - Magnesium N/A mg/I Mn - Manganese No and field acidified Yes n/z No ) N/A mg/I Ni - Nickel N/A mg/I Pb - Lead N/A mg/I N/A mg/I N/A ug/I N/A ug/I N/A ug/I N/A ug/I Zn - Zinc Ammonia Nitrogen N/A ug/I N/A ug/I N/A ug/I mg/I Other (Specify Compounds and Concentration Units) Fluoride MIBK Ag - Silver N/A ug/I Se- Selenium N/A ug/I Sodium N/A ug/l Organics: (GC, GC/MS, N/A ug/I (Specify test method #. N/A ug/l Report attached? Yes N/A ug/l VOC N/A ug/I N/A mg/I N/A ug/I N/A ug/I N/A ug/I N/A ug/I HPLC) Attach lab report.) (1) No X (2) method# method# method# 1 certify that, to the best of my knowledge and belief, the information submitted in this report is true, accurate, and complete, and that the laboratory analytical data was produced using approved methods of analysis by a North Carolina DWQ (formerly DEM) certified laboratory. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisionment for knowing violations. NOTE: GW-59 Rev 4/98 Ross M. Smith - Manager, Environmental Affairs Permittee (of Authorized Agent) Name and Title - Please type or print 211 Signature of Permittee (or Authorized Agent) (Date) �Zp ' PCS Phosphate Co., Inc. - Tank Farm Remediation System Quarterly Monitoring Date: /-/fl-// Time: Tech: System Oau e Pressures SWW-1 �O/ sww-i cww-1 CVNN-7 �sa� File: 12-07-02 p= ne pat MIL Lewd Rd to MIL Ditch 12.91 Barge Slip 10.59 /. Water Level Control Tank %= MSL Sand Layer Pelzometers Level Indicators Well ID TOC Elevation MSL' TOC Ste Wtr ' eveel�ll'i Level Relative To - MSL Ft. Well ID TOC - Elevation MSL' TOC Ste WIT Level' Level Relative To MSL Ft Spz-1. 10.47 ''L//y/ -G ,5: , Cpz-1 1051 /A7/ -8c1,� Spz-2 '. 1121 bb7, 9; BO. / 9/ cpz-2 1025 IjJ4V .99. Spz-3 11.87 0 Veg // yf! Cpz-3 11.12 g09 Q/ -2 9/ Spz-4 11A5 %v 5 ��/,a%O CPW 9.65 /9/ 7y /. 09 Spz-5 11.45 /OO /9, «,5 MWTF-1A• 14.35 \`, JO/ %E.I' Spz-6 . 1123 ,fit -/,00 MWTF-1B• 14.36 ,_94' Zge SPz-7. : . 11.59 / ?.// - /-6 3 MWTF-1C• .14.44 ,c 7P% _ -,910 9 Spz-8 1157 it - /dS . MwTF-2A 14.05 ' 4 _2 9 7 no Spz-9 .: 11.01 965 / 929 MW7F-20 14.02 //,41 a//) Spz-10 12.18 - //-94s /%S? MWTF-2C 14.08 C-4 OO /0.94 SPW - 9.95 9'3a ,. a MWTF3A - 1221 ,i ee) p. i// MWTF30 12.18 f//i 0'/aee' MWTF-3C 12.19 /441 9/ -bieRA Sand Layer And. Croatan Formation Withdrawal Wells Well ID TOC Elevation MSL' Max Ste Mr Level Ft. Pump Activation Depth Rel MSL. Max Level Relative To MSL Ft Control Point - MSL' Is Well Pumping? (Y)es/Q4o Comments SWW-1 10.70 {O. 20 6' %%, ‘..40 +1 'to+2' cww-1 10.60 3/ 0 -‘2.q° -2'to -1' SWW-2 9.99 /' .g 6' -- 7/,7 / +1'to+2' FJY,i /fGr/%�ib3. cww-z. 1023 9; /�$ 9' QY, Mg- -2'to-1' e/i&/ t %'/ Tfri SWW3 9.97 /g. o,e9 9 -.5, get +1'to+2' W CW -3 e.95 r6„ S 9' 6j. A/C -2 ' to -1' sWW-4 ion 77/ S' / %/ _ +1 'to+2' CWW-4. 10.73 L- T 9' .5, d7 -2'to -1' SWW-5 10.80 O/!j 6' -61B% ♦1'to +2' CWW-5. 10.74 6, /, 9' 4'.S -210,1' SWW-6 10.66 '.S// 6' . 0��, y/,. +1'to+2' \ CWW-6' 9an/ 1,0g 9 404// -2'to -1' SWW-7 10.70 9 - +1 ' to+2' /,/J' Oladele- CWW-7: 9.95 5, 04" ,/ 9' J, //O -2'to-1'' Revised712g/02 • Riser length added to TOC elevation 124197 D:1Data\Forms\Well Fam\iankFarm Remed WelWtls sr' SPZ-1 .� CPZe1 OFFICE CUT—OFF WALL Ie CPZ-2 � r ASPHALT ROAD cnW-e SWW4 CWW4 ►t IMMI t SW Wd CWW3 MWTF3 CLUSTER / DRAINAGE DITCH S.P.A PLANT CPZ-3 A SPZ-9 x MWIFJ CLUSTER - SPZ-5 SPZ 7 \;[ `Z-S • PIPERACK SPILL CONTAINMENT PAD O 0 S.P.A PLANT WATER LEVEL cONTROLTAM< CO-2 1 044 C?Nj00I cTW4 - _ CIW-7 SPZ-10 sPLe 002 064 • T r_._ :1- T _ HI RI HIP III N I' el HOY. It• r..M.I.+ wt„ •.•,NenII ••II•.I•.1n •.IIIIIII•NY WI II n..•IAli I..11 Y•.•.I. W.1ln.•AW. WI II n..•1•N I..n Y•I,NI Olt. 01.14 *I11 0.1. I•.II III....IOIIII t.nl I ItAH I.111 O N. 1• W1.1 * ,I AII11 ItI ..Oln.•WI •II LOCATION PLAN FOR TANK FAH AREA REMEDIAL ACTION SYSII M WELLS AND PIEZOMETI II ' • FIGURE 1 PCS PHOSPHATE - TANK FARM REMEDIAL ACTION PLAN QUARTERLY OPERATIONAL AND MAINTENANCE REPORT FOR THE INJECTION AND WITHDRAWAL WATER WELLS November 2010 — January 2011 The Tank Farm Remediation System consists of a series of seven- (7) injection water wells located on the south side of the Tank Farm Area and a series of fourteen (14) withdrawal water wells located on the north side of the Tank Farm Area. Injection Water Well System The injection water well system operated with the DPW Water - Ultraviolet Light Disinfection system during the period. New UV tubes and bulbs were installed on December 2, 2010. Daily operational data are collected by the Shipping Department and reported to the Environmental Affairs Department. The total monthly and quarterly volumes of water injected as well as the month end water level in the Water Level Control Tank are: DPW WATER GALLONS TOTAL GALLONS AVERAGE GPM TANK LEVEL FEET, MSL November 433,706 0 433,706 10.0 15.0 December 668,698 0 668,698 15.0 15.0 January 455,215 0 455,215 16.6 15.0 TOTALS 1,557,619 0 1,557,619 H:\Reports\2011\Quarterly\TFRAS Report Fourth Quarter 2010.docx 3 Withdrawal Well System The withdrawal water well pumps are monitored daily by the area Maintenance Department and preventative maintenance work is performed as needed. The total monthly and quarterly withdrawal water volumes for the period are: SAND FORMATION GALLONS , CROATAN FORMATION GALLONS TOTAL GALLONS AVERAGE GPM November 154,948 176,406 331,354 7.7 December 34,255 352,812 387,067 9.0 January 319,343 472,376 791,719 18.3 TOTALS 508,546 1,001,594 1,510,140 Some additional short periods of planned downtime for preventative maintenance, pipe header cleaning, and troubleshooting on individual pumps in the fourteen well system were experienced. Details of these activities are: Confined Sand Formation Withdrawal Well (SWW) Pumps On 11/3 unplugged SWW Header. On 12/8 changed oil filter on air compressor. On 1/26 the main water meter was repaired. SWW-1: SWW-2: SWW-3: SWW-4: On 12/14 replaced pump. On 12/30 replaced pump. On 1/6 acid washed well. On 1/19 installed new counter. SWW-5: On 11/5 replaced pump. On 12/16 replaced pump. SWW-6: On 11/4 replaced pump. SWW-7: H:\Reports\2011\Quarterly\TFRAS Report Fourth Quarter 2010.docx 4 Croatan Formation Withdrawal Well (CWW) Pumps CWW-1: CWW-2: On 1/6 acid washed well. CWW-3: CWW-4: CWW-5: On 1/6 acid washed well. CWW-6: CWW-7: H:\Reports\2011\Quarterly\TFRAS Report Fourth Quarter 2010.docx 5 RECF NED FEB 1 5 2011