HomeMy WebLinkAboutWI0700012_Monitoring (Report)_20000223GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORTING FORM 00061010 FACILITY INFORMATION Facilty Name: PCS PHOSPHATE CO., INC. - Aurora Division Permit Name (if different): Facility Addresss: P.O. Box 48 Aurora, NC 27806 County: Beaufort Contact Person: Jimmy Hardy Telephone: (252)322-8154 Well Locations/Site Name: Tank Farm No. of Wells to be Sampled 18 Well Identification Number (from Permit): CWW-1 Well Depth: 55.00 ft. Well Diamter: 4 inch Screened Interval: 33.27 ft. to 52.68 ft. Depth to Water Level: 7.86 ft. below measuring point. Measuring Point is 2.25 ft above land surface. GALLONS of water pumped/bailed before sampling. For Groundwater Treatment Sys ems Check One: Influent (98) X Effluent (99) CONTINUOUS Field Analysis: pH 6.3 , Specific Conductance 1965 uMhos Temp. 18.6 oC, Odor NONE Appearance: CLEAR colloidal concentrations Date sample collected: Date sample analyzed: Laboratory Name: Certification No(s) Mail Original to: DIVISION OF WATER QUALITY GROUNDWATER SECTION -PERMITS AND COMPLIANCE UNIT P.O. BOX 29578 LEIGH, NC 27626-0578 Phone: (919)733-3221 PERMIT #: WI0700012 Non -Discharge NPDES TYPE OF PERMITTED OPERATION BEING MONITORED EXPIRATION DATE: UIC X 09/30/01 Lagoon Spray Field Rotary Distributor Other Remediation: Infiltration Gallery X Remediation : Land Application of Sludge C. Q "� c_ c Note: Values should reflect dissolved and 3211 1/27/00 1/27/00 to 02/07/00— PCS PHOSPHATE" 330 PARAMETERS: (Samples for metals were collected unfiltered Yes n/a COD N/A mg/I Nitrite (NO2 as N) Coliform: MF Fecal N/A /100m1 Nitrate (NO3 as N) Coliform: MF Total N/A /100m1 Phosphorus: Total as P 4.000 mg/I (Note: Use MPN method for highly turbid samples) Orthophosphate Dissolved Solids: Total 1996 mg/I Al - Aluminum pH (when analyzed) 6.8 units Ba - Barium TOC 14.1 mg/1 Ca - Calcium N/A ug/l Chloride 74.9 mg/I Cd- Cadmium N/A ug/I Arsenic N/A mg/I Chromium: Total Grease and Oils N/A mg/1 Cu - Copper N/A ug/l Phenol N/A mg/I Fe - Iron Sulfate 695.2 mg/I Hg - Mercury No and field acidified Yes n/a No N/A mg/I Ni - Nickel N/A mg/I Pb - Lead Zn - Zinc N/A mg/I Ammonia Nitrogen N/A ug/I Other (Specify Compounds and Concentration Units) I f/A N/A N/A N/A ug/I Fluoride MIBK Ag - Silver N/A ug/I Se- Selenium Specific Conductance Total Ammonia TKN as N N/A ug/I N/A ug/I N/A uMhos K- Potassium N/A mg/1 Mg - Magnesium N/A mg/I Mn - Manganese N/A ug/I N/A ug/I NIA ug/I Sodium Organics: (GC. GC/MS, (Specify test method #. Report attached? Yes VOC 0.24 N/A N/A N/A N/A HPLC) Attach lab report.) (1) No X method# method# method# ug/l u g/I ug/I mg/I mg/l ug/I ug/I ug/I ug/I (2) certify that, to the best of my knowledge and belief, the information submitted in this report is true, using approved methods of analysis by a North Carolina DWQ (formerly DEM) certified laboratory. false information, including the possibility of fines and imprisionment for knowing violations. accurate, and complete, and that the laboratory analytical data was produced I am aware that there are significant penalties for submitting NOTE: GW-59 Rev 4/98 Terry L. Baker - Manager, Environmental Affairs Permittee (of Authorized gent) Name and Title - Please type or print - 75ri —2-/1Z 5/ ,i.pc c7 Signature of Permittee (or Authorized Agent) (Date) GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORTING FORM FACILITY INFORMATION Facilty Name: PCS PHOSPHATE CO., INC. - Aurora Division Permit Name (if different): Facility Addresss: P.O. Box 48 Aurora, NC 27806 County: Beaufort Contact Person: Jimmy Hardy Telephone: (252)322-8154 Well Locations/Site Name: Tank Farm No. of Wells to be Sampled 18 from _) Well Identification Number (from Permit): Well Depth: 52.15 ft. Well Diamter: CWW-2 4 inch Screened Interval: 30.57 ft. to 49.82 ft. Depth to Water Level: 7.58 ft. below measuring point. Measuring Point is 3.00 ft above land surface. GALLONS of water pumped/bailed before sampling: For Groundwater Treatment Sys ems Check One: Influent (98) X Effluent (99) CONTINUOUS Field Analysis: pH 6.5 , Specific Conductance 1941 uMhos Temp. 19.4 oC, Odor NONE Appearance: CLEAR Mail Original to: DIVISION OF WATER QUALITY GROUNDWATER SECTION -PERMITS AND COMPLIANCE UNIT P.O. BOX 29578 RALEIGH, NC 27626-0578 Phone: (919)733-3221 PERMIT #: WI0700012 Non -Discharge NPDES TYPE OF PERMITTED OPERATION BEING MONITORED EXPIRATION DATE: UIC X 09/30/01 Lagoon Spray Field Rotary Distributor Other Remediation: Infiltration Gallery X Remediation : Land Application of Sludge Cf C? � C) —4. G} Note: Values should reflect dissolved and colloidal concentrations Date sample collected: 1/27/00 Date sample analyzed: Laboratory Name: 1/27/00 to 02/07/09- PCS PHOSPHATE Certification No(s) 330 PARAMETERS: (Samples for metals were collected unfiltered COD Nitrite (NO2 as N) mg/I /100m1 /100m1 Coliform: MF Fecal Nitrate (NO3 as N) Coliform: MF Total N/A N/A N/A (Note. Use MPN method for highly turbid samples) Dissolved Solids: Total 1936 pH (when analyzed) 6.8 TOC 13.3 Chloride 103.9 Arsenic N/A Grease and Oils N/A Phenol N/A Sulfate Specific Conductance Total Ammonia TKN as N 563.4 N/A N/A N/A mg/I units mg/I mg/I mg/I mg/I mg/I mg/I uMhos mg/I mg/I Yes n/a No and field acidified N/A mg/I Ni - Nickel N/A mg/I Pb - Lead Zn - Zinc N/A mg/I Ammonia Nitrogen N/A ug/I Other (Specify Compounds and Concentration Units) Phosphorus: Total as P Orthophosphate Al - Aluminum Ba - Barium Ca - Calcium 3.950 mg/I Yes n/a No c-/1 Cd- Cadmium Chromium: Total Cu - Copper Fe - Iron Hg - Mercury N/A ug/I Fluoride N/A ug/I MIBK N/A ug/I Ag - Silver N/A ug/I Se- Selenium N/A ug/I Sodium K- Potassium Mg - Magnesium Mn - Manganese N7A N/A N/A 0.22 N/A N/A N/A N/A N/A ug/I Organics: (GC, GC/MS, HPLC) N/A ug/I (Specify test method #. Attach lab report.) N/A ug/I Report attached? Yes (1) No X N/A ug/I VOC : method# N/A ug/I method# method# ug/I ug/I ug/I mg/I mg/l ug/I ug/I ug/I ug/I (2) I certify that, to the best of my knowledge and belief, the information submitted in this report is true, accurate, and complete, and that the laboratory analytical data was produced using approved methods of analysis by a North Carolina DWQ (formerly DEM) certified laboratory. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisionment for knowing violations. NOTE: GW-59 Rev 4/98 Terry L. Baker - Manager, Environmental Affairs Permittee (of Authorized Agent) Name and Title - Please type or print Signature of Permittee (or Authorized Agent) (Date) GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORTING FORM onnA 1012 FACILITY INFORMATION Facilty Name: PCS PHOSPHATE CO., INC. -Aurora Division Permit Name (if different): Facility Addresss: P.O. Box 48 Aurora, NC 27806 County: Beaufort Contact Person: Jimmy Hardy Telephone: (252)322-8154 Well Locations/Site Name: Tank Farm No. of Wells to be Sampled 18 Well Identification Number (from Permit): CWW-3 Well Depth: 53.00 ft. Well Diamter: Screened Interval: 36.42 ft. to 50.67 ft. Depth to Water Level: Measuring Point is GALLONS 4 inch 7.50 ft. below measuring point. 3.08 ft above land surface. For Groundwater Treatment Systems Check One: Influent (98) X Effluent (99) of water pumped/bailed before sampling: CONTINUOUS Field Analysis: pH 6.5 , Specific Conductance 2261 uMhos Temp. 26.1 oC, Odor NONE Appearance: CLEAR Mail Original to: DIVISION OF WATER QUALITY GROUNDWATER SECTION -PERMITS AND COMPLIANCE UNIT P.O. BOX 29578 RALEIGH, NC 27626-0578 Phone: (919)733-3221 PERMIT #: WI0700012 Non -Discharge NPDES TYPE OF PERMITTED OPERATION BEING MONITORED Lagoon Spray Field X Remediation : EXPIRATION DATE: UIC X 09/30/01 Rotary Distributor Other Remediation: Infiltration Gallery Land Application of Sludge Note: Values should reflect dissolved and colloidal concentrations Date sample collected: 1/27/00 Date sample analyzed: 1/27/00 to 02/07/00 Laboratory Name: PCS PHOSPHATE Certification No(s) 330 C? O C: A PARAMETERS: (Samples for metals were collected unfiltered COD N/A mg/I Coliform: MF Fecal N/A /100m1 Coliform: MF Total N/A /100m1 (Note: Use MPN method for highly turbid samples) Dissolved Solids: Total 1800 pH (when analyzed) TOC Chloride Arsenic Grease and Oils Phenol Sulfate Specific Conductance Total Ammonia TKN as N 6.3 10.7 184.2 N/A N/A N/A 481.0 N/A N/A N/A mg/I units mg/I Ca - Calcium mg/I mg/l mg/l mg/1 Fe - Iron mg/1 Hg - Mercury uMhos mg/l mg/l Yes n/a No and field acidified Yes n/a No Nitrite (NO2 as N) Nitrate (NO3 as N) Phosphorus: Total as P Orthophosphate Al - Aluminum Ba - Barium N/A mg/I Ni - Nickel N/A mg/I Pb - Lead Zn - Zinc N/A mg/I Ammonia Nitrogen 5.750 mg/I N/A ug/I Cd- Cadmium Chromium: Total Cu - Copper N/A ug/I N/A ug/I "II r N/A ug/l N/A ug/l N/A ug/I Other (Specify Compounds and Concentration Units) Fluoride MIBK N/A ug/I Ag - Silver N/A ug/I N/A ug/I K- Potassium Mg - Magnesium Mn - Manganese Se- Selenium Sodium 0.22 N/A N/A N/A N/A N/A ug/I Organics: (GC, GC/MS, HPLC) N/A ug/I (Specify test method #. Attach lab report.) N/A ug/l Report attached? Yes (1) No X N/A ug/l VOC N/A ug/I method# method# method# mg/l mg/I ug/I ug/I ug/I ug/I (2) certify thatto the best of my knowledge and belief, the information submitted in this report is true, accurate. and complete, and that the laboratory analytical data was produced using approved methods of analysis by a North Carolina DWQ (formerly DEM) certified laboratory. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisionment for knowing violations. NOTE: GW-59 Rev 4/98 Terry L. Baker - Manager, Environmental Affairs Permittee (of Authorized Agent) Name and Title - Please type or print Signature of Permittee (or Authorized Agent) (Date) GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORTING FORM 110061013 FACILITY INFORMATION Facilty Name: PCS PHOSPHATE CO., INC. - Aurora Division Permit Name (if different): Facility Addresss: P.O. Box 48 Aurora, NC 27806 County: Beaufort Contact Person: Jimmy Hardy Telephone: (252)322-8154 Well Locations/Site Name: Tank Farm No. of Wells to be Sampled 18 Well Identification Number (from Permit): CWW-4 Well Depth: 53.00 ft. Well Diamter: Screened Interval: 41.67 ft. to 50.92 ft. Depth to Water Level: Measuring Point is 4 inch 6.62 ft. below measuring point. 2.75 ft above land surface. For Groundwater Treatment Sys ems Check One: Influent (98) X Effluent (99) GALLONS of water pumped/bailed before sampling: CONTINUOUS Field Analysis: pH 6.3 , Specific Conductance 2253 uMhos Temp. 27.2 oC, Odor NONE Appearance: CLEAR Mail Original to: DIVISION OF WATER QUALITY GROUNDWATER SECTION -PERMITS AND COMPLIANCE UNIT P O. BOX 29578 RALEIGH, NC 27626-0578 Phone: (919)733-3221 PERMIT #: WI0700012 Non -Discharge NPDES TYPE OF PERMITTED OPERATION BEING MONITORED Lagoon Remediation: Infiltration Gallery EXPIRATION DATE: UIC X 09/30/01 Spray Field X Remediation Rotary Distributor Land Application of Sludge Other Note: Values should reflect dissolved and colloidal concentrations Date sample collected: Date sample analyzed: Laboratory Name: 1/27/00 s. �L7 1/27/00 to 02/07/00 PCS PHOSPHATE Certification No(s) 330 PARAMETERS: (Samples for metals were collected unfiltered Yes n/a COD Coliform: MF Fecal Coliform: MF Total N/A N/A N/A (Note: Use MPN method for highly turbid samples) Dissolved Solids: Total pH (when analyzed) TOC mg/I Nitrite (NO2 as N) /100m1 Nitrate (NO3 as N) /100m1 1784 mg/I 6.9 units 10.6 mg/I Chloride Arsenic Grease and Oils Phenol Sulfate 118.3 mg/I N/A mg/I N/A mg/I Specific Conductance Total Ammonia TKN as N No and field acidified N/A mg/1 Ni - Nickel Phosphorus: Total as P Orthophosphate Al - Aluminum Ba - Barium Ca - Calcium 5.450 mg/1 N/A mg/I Pb - Lead Zn - Zinc N/A mg/1 Ammonia Nitrogen Yes n/a N/A ug/I Cd- Cadmium Chromium: Total Cu - Copper N/A mg/I Fe - Iron 526.4 mg/I Hg - Mercury N/A ug/I N/A ug/I N/A ug/I No IV N N/A N/A Other (Specify Compounds and Concentration Units) Fluoride MIBK Ag - Silver N/A ug/I Se- Selenium N/A ug/I Sodium N/A uMhos K- Potassium N/A mg/1 Mg - Magnesium N/A mg/I Mn - Manganese 0.15 N/A N/A N/A N/A N/A ug/I Organics: (GC, GC/MS, HPLC) N/A ug/I (Specify test method #. Attach lab report.) N/A ug/I Report attached? Yes (1) No N/A ug/I VOC N/A ug/I method# method# method# ug/I ug/I ug/l mg/I mg/I ug/I ug/I ug/I ug/I (2) certify that, to the best of my knowledge and belief, the information submitted in this report is true, accurate, and complete, and that the laboratory analytical data was produced using approved methods of analysis by a North Carolina DWQ (formerly DEM) certified laboratory. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisionment for knowing violations. NOTE: GW-59 Rev 4/98 Terry L. Baker - Manager, Environmental Affairs Permittee (of Authorized Agent) Name and Title - Please type or print ea/AA. Signature of Permittee (or Authorized Agent) (Date) GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORTING FORM 00061014 FACILITY INFORMATION Facilty Name: PCS PHOSPHATE CO., INC. - Aurora Division Permit Name (if different): Facility Addresss: P.O. Box 48 Aurora, NC 27806 County: Beaufort Contact Person: Jimmy Hardy Telephone: (252)322-8154 Well Locations/Site Name: Tank Farm No. of Wells to be Sampled 18 Orcen p} Mail Original to: Well Identification Number (from Permit): CWW-5 Well Depth: 53.17 ft. Well Diamter: Screened Interval: 41.75 ft. to 51.08 ft. 4 inch Depth to Water Level: 7,81 ft. below measuring point. Measuring Point is 2.58 ft above land surface. For Groundwater Treatment Sys ems Check One: Influent (98) X Effluent (99) GALLONS of water pumped/bailed before sampling: CONTINUOUS Field Analysis: pH 6.4 , Specific Conductance 1856 uMhos Temp. 30.8 oC, Odor NONE Appearance: CLEAR DIVISION OF WATER QUALITY GROUNDWATER SECTION -PERMITS AND COMPLIANCE UNIT P.O. BOX 29578 RALEIGH. NC 27626-0578 Phone: (919)733-3221 PERMIT #: WI0700012 EXPIRATION DATE: 09/30/01 Non -Discharge UIC X NPDES TYPE OF PERMITTED OPERATION BEING MONITORED Lagoon Remediation: Infiltration Gallery Spray Field X Remediation : Rotary Distributor Land Application of Sludge Other Note: Values should reflect dissolved and colloidal concentrations Date sample collected: 1/27/00 Date sample analyzed: 1/27/00 to 2/7/00 Laboratory Name: PCS PHOSPHATE Certification No(s) 330 0 PARAMETERS: (Samples for metals were collected unfiltered Yes COD Coliform: MF Fecal Coliform: MF Total N/A N/A N/A (Note. Use MPN method for highly turbid samples) Dissolved Solids: Total 1284 pH (when analyzed) TOC Chloride Arsenic Grease and Oils Phenol Sulfate Specific Conductance Total Ammonia TKN as N 7.0 8.4 71.4 N/A N/A N/A 318.8 N/A N/A N/A mg/1 /100m1 /100ml mg/l units mg/1 mg/I mg/I mg/l mg/I mg/I uMhos mg/I mg/I Nitrite (NO2 as N) Nitrate (NO3 as N) n/a No and field acidified Phosphorus: Total as P Orthophosphate Al - Aluminum Ba - Barium Ca - Calcium 4.500 mg/I N/A mg/I N/A ug/I Cd- Cadmium Chromium: Total Cu - Copper Sodium N/A ug/l Organics: (GC, GC/MS, HPLC) N/A ug/l (Specify test method #. Attach lab report.) N/A ug/I Report attached? Yes (1) No X N/A ug/I VOC : method# method# method# N/A ug/I N/A ug/l N/A ug/I N/A mg/l Ni - Nickel N/A mg/1 Pb - Lead Zn - Zinc Yes n/a No u� N/A - N/A N/A Ammonia Nitrogen Other (Specify Compounds and Concentration Units) Fluoride MIBK Ag - Silver N/A ug/I Se- Selenium Fe - Iron Hg - Mercury K- Potassium Mg - Magnesium Mn - Manganese 0.17 N/A N/A N/A N/A N/A ug/I N/A ug/l ug/I ug/I ug/I mg/I mg/I ug/I ug/I ug/I ug/I (2) I certify that, to the best of my knowledge and belief, the information submitted in this report is true, accurate, and complete, and that the laboratory analytical data was produced using approved methods of analysis by a North Carolina DWQ (formerly DEM) certified laboratory. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisionment for knowing violations. NOTE: GW-59 Rev 4/98 T, h'• Signature of Permittee (or Authorized Agent) Terry L. Baker - Manager, Environmental Affairs Permittee (of Authorized gent) Name and Title - Please type or print -z/2 3/460e) (Date) GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORTING FORM 00061015 FACILITY INFORMATION Facilty Name: PCS PHOSPHATE CO., INC. - Aurora Division Permit Name (if different): Facility Addresss: P.O. Box 48 Aurora, NC 27806 County: Beaufort Contact Person: Jimmy Hardy Telephone: (252)322-8154 Well Locations/Site Name: Tank Farm No. of Wells to be Sampled 18 Well Identification Number (from Permit): CWW-6 Well Depth: 53.00 ft. Well Diamter: 4 inch Screened Interval: 36.62 ft. to 50.88 ft. Depth to Water Level: 7.26 ft. below measuring point. Measuring Point is 2.92 ft above land surface. GALLONS of water pumped/bailed before sampling: For Groundwater Treatment Sys ems Check One: Influent (98) X Effluent (99) CONTINUOUS Field Analysis: pH 6.3 , Specific Conductance 1679 uMhos Temp. 30.8. oC, Odor NONE Appearance: CLEAR Mail Original to: DIVISION OF WATER QUALITY GROUNDWATER SECTION -PERMITS AND COMPLIANCE UNIT P.O. BOX 29578 RALEIGH, NC 27626-0578 Phone: (919)733-3221 PERMIT #: WI0700012 Non -Discharge NPDES TYPE OF PERMITTED OPERATION BEING MONITORED EXPIRATION DATE: U I C X 09/03/01 Lagoon Spray Field Rotary Distributor Other Remediation: Infiltration Gallery X Remediation : Land Application of Sludge Note: Values should reflect dissolved and colloidal concentrations Date sample collected: 1/27/00 Date sample analyzed: 1/27/00 to 2/7/00 Laboratory Name: PCS PHOSPHATE U 3 Certification No(s) 330 C..? O 7E3 PARAMETERS: (Samples for metals were collected unfiltered Yes n/a COD N/A mg/I Nitrite (NO2 as N) Coliform: MF Fecal N/A /100m1 Nitrate (NO3 as N) No and field acidified N/A mg/I Ni - Nickel Coliform: MF Total N/A /100m1 Phosphorus: Total as P (Note: Use MPN method for highly turbid samples) Orthophosphate Dissolved Solids: Total 1144 mg/I Al - Aluminum pH (when analyzed) 6.7 units Ba - Barium TOC 10.0 mg/I Ca - Calcium Chloride 90.2 mg/1 Cd- Cadmium 9.600 mg/I N/A mg/I Pb - Lead Zn - Zinc N/A mg/I Ammonia Nitrogen N/A ug/l Other (Specify Compounds and Concentration Units) Yes n/a No N/A ug/I Fluoride N/A ug/I MIBK N/A ug/I Arsenic N/A mg/I Chromium: Total Grease and Oils N/A mg/I Cu - Copper Phenol N/A mg/I Fe - Iron Sulfate 263.1 mg/1 Hg - Mercury Specific Conductance Total Ammonia TKN as N Ag - Silver N/A ug/I Se- Selenium N/A ug/I Sodium N/A uMhos K- Potassium N/A ug/I N/A ug/I N/A mg/I Mg - Magnesium N/A mg/I Mn - Manganese N/A ug/I N/A ug/I N/A ug/I (:mr N/A N/A N/A 0.20 N/A N/A N/A N/A Organics: (GC, GC/MS, HPLC) (Specify test method #. Attach lab report.) Report attached? Yes (1) No X VOC method# method# method# ug/I ug/I ug/I mg/I mg/1 ug/I ug/l ug/I ug/l (2) I certify that, to the best of my knowledge and belief, the information submitted in this report is trueaccurate, and complete, and that the laboratory analytical data was produced using approved methods of analysis by a North Carolina DWQ (formerly DEM) certified laboratory. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisionment for knowing violations. NOTE: GW-59 Rev 4/98 Terry L. Baker - Manager, Environmental Affairs Permittee (of Authorized gent) Name and Title - Please type or print —77 iC Z7 . 4 Signature of Permittee (or Authorized Agent) (Da() GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORTING FORM FACILITY INFORMATION Facilty Name: PCS PHOSPHATE CO., INC. - Aurora Division Permit Name (if different): Facility Addresss: P.O. Box 48 Aurora, NC 27806 County: Beaufort Contact Person: Jimmy Hardy Telephone: (252)322-8154 Well Locations/Site Name: Tank Farm No. of Wells to be Sampled 18 Well Identification Number (from Permit): Well Depth: 53.00 ft. Well Diamter: CWW-7 4 inch Screened Interval: 36.58 ft. to 50.83 ft. Depth to Water Level: 7.42 ft. below measuring point. Measuring Point is 1.25 ft above land surface. GALLONS of water pumped/bailed before sampling: Field Analysis: pH 6.6 , Specific Conductance 1182 uMhos For Groundwater Treatment Sys ems Check One: Influent (98) X Effluent (99) CONTINUOUS Temp. 23.8 oC, Odor NONE Appearance: LT. RUST Mail Original to: PERMIT #: DIVISION OF WATER QUALITY GROUNDWATER SECTION -PERMITS AND COMPLIANCE UNIT P.O. BOX 29578 RALEIGH, NC 27626-0578 Phone: (919)733-3221 W10700012 Non -Discharge NPDES TYPE OF PERMITTED OPERATION BEING MONITORED Lagoon Remediation: Infiltration Gallery EXPIRATION DATE: UIC X 09/03/01 Spray Field X Remediation : Rotary Distributor Land Application of Sludge Other Note: Values should reflect dissolved and colloidal concentrations Date sample collected: Date sample analyzed: Laboratory Name: Certification No(s) CI G A 1/27/00 1/27/00 to 2/7/00 PCS PHOSPHATE 330 • PARAMETERS: (Samples for metals were collected unfiltered Yes COD N/A mg/I Coliform: MF Fecal Coliform: MF Total N/A /100m1 N/A /100m1 (Note. Use MPN method for highly turbid samples) Dissolved Solids: Total 886 mg/l pH (when analyzed) 7.1 units TOC 13.0 mg/I Chloride Arsenic 76.1 mg/I Grease and Oils Phenol Sulfate N/A mg/1 N/A mg/I Specific Conductance Total Ammonia TKN as N Nitrite (NO2 as N) Nitrate (NO3 as N) Phosphorus: Total as P Orthophosphate Al - Aluminum Ba - Barium Ca - Calcium Cd- Cadmium Chromium: Total Cu - Copper N/A mg/I Fe - Iron 185.9 mg/l Hg - Mercury n/a No and field acidified N/A mg/I Ni - Nickel N/A mg/I Pb - Lead 2.100 mg/I Zn - Zinc N/A mg/I N/A ug/I N/A ug/l N/A ug/I Yes n/a No N!A N/A N/A Ammonia Nitrogen Other (Specify Compounds and Concentration Units) Fluoride MIBK N/A ug/I Ag - Silver N/A ug/I Se- Selenium N/A ug/I Sodium N/A uMhos K- Potassium N/A mg/I Mg - Magnesium N/A mg/I Mn - Manganese 0.20 N/A N/A N/A N/A N/A ug/I Organics: (GC, GC/MS, HPLC) N/A ug/I (Specify test method #. Attach lab report.) N/A ug/I Report attached? Yes (1) No X N/A ug/I VOC : method# N/A ug/I method# method# ug/I ug/I ug/I mg/I mg/1 ug/I ug/I ug/I ug/I (2) certify that, to the best of my knowledge and belief, the information submitted in this report is true, accurate. and complete. and that the laboratory analytical data was produced using approved methods of analysis by a North Carolina DWQ (formerly DEM) certified laboratory. I am aware that there are significant penalties for submitting false information. including the possibility of fines and imprisionment for knowing violations. NOTE: GW-59 Rev 4/98 / •V Signature of Permittee (or Authorized Agent) Terry L. Baker - Manager, Environmental Affairs Permittee (of Authorized ;gent) Name and Title - Please type or print 3/zo66 (Date) Date: Time: Tech: PCS Phosphate Co., Inc. - Tank Farm Remediation System Quarterly Monitoring /-.34-00 7»? Z. System Gauge Pressures sww-1 0 - as -Ps: SWW-7 0-.252-93i CWW-1 U - /g/J'S; CWW-7 0./&ems; File:16-03-003-02 pc: TLB Level (msl Ditch Level vj 10 Barge Slip 9 4/0 Water Level 991; Control Tank =MSL /iJ.07%� Sand Layer Pelzometers Level Indicators Well ID TOC Elevation MSL' TOC Stc Wtr Level' Level Relative To MSL Ft. Well ID TOC Elevation MSL' TOC Stc Wtr Level Relative To Ft. Spz-1 10.47 -n9 7a lo. 7 - Cpz-1 10.51 .LLevell'' 0 yMSL yJ Spz-2 11.21 8 07 5. /5/ Cpz-2 10.25 �/y. 99, 44 .7. AS/ Spz-3 11.87 -5-, 80 ' 4.07 Cpz-3 11.12 gate 2. 9P Spz-4 11.45 6. SO .J ,/S CPW 9.65 R 76. 0.39 /Q.,S,s Spz-5 11.45 9'. /6 ar.. a 9 MWTF-1A • 14.35 3. go Spz-6 11.23 9,/,2 a.// MWTF-1B• 14.36 1J9 977 Spz-7 11.59 /a 42$ /-S, MWTF-1C• 14.44 8013 6„2/ Spz-8 11.57 6, /O S/o0 MWTF-2A 14.05 A yg 757 Spz-9 11.01 B /( 4,9,49_5 MWTF-28 14.02 /Q 77 .fa5 Spz-10 12.16 55 06 7./O MWTF-2C 14.08 /9•4" 00 SPW 9.95 '7 ,j !, /. 9// MWTF-3A 12.21 y. 00 8 /5 MWTF-3B 12.18 9.98 07.a0 MWTF-3C 12.19 0.0.1 0. /.) Sand Layer And Croatan Formation Withdrawal Wells Well ID TOC Elevation MSL' Max Stc Wtr Level,Ft. Max Level Relative To MSL Ft. Control Point MSL' Is Well Pumping (Y)es/(N)o Comments SWW-1 10.70 at 0,3 +1' to+2' Ye5 CWW-1 10.60 �py.O,i -//2/ -2'to -1' YS SWW-2 9.99 n7t. 070 �,2Q +1 ' to +2' ./CY!/1ine/YYana' gr At) lip f CWW-2 10.23 r€7• /.boo -/4a -2'to-1' �r/o1 I;., SWW-3 9.97 6. 7p 0.719 +1'to+2' CWW-3 9.95 7SO ',SO -2'to-1' ��5 Y SWW-4 10.73 6.,$S O..�Sn +1' to+2' CWW-4 10.73 �.(,,2 -r 3S -2'to-1' i/j (eh SWW-5 10.80 or, lc 0. 55 +1' to+2' ]e9 CWW-5 10.74 7p/ -//9 -2'to-1' SWW-6 10.66 6.6,E O. *6 +1'to+2' /[S Ir/�9. CWW-6 9.92 /7 a{e -/ 77 -2'to-1' SWW-7 10.70 /.3 5 +1'to+2' +IVCJJ 143 CW-7 W 9.95 �z / , 7 -j75 / -�7j -2 'to-1' Yi Revised 8/12/97 • Riser length added to TOC elevation 1/24/97 PCS095.XLS PCS PHOSPHATE - TANK FARM REMEDIAL ACTION PLAN QUARTERLY OPERATIONAL AND MAINTENANCE REPORT FOR THE INJECTION AND WITHDRAWAL WATER WELLS November, 1999 — January, 2000 The Tank Farm Remediation System consists of a series of seven (7) injection water wells located on the south side of the Tank Farm Area and a series of fourteen (14) withdrawal water wells located on the north side of the Tank Farm Area. Injection Water Well System The injection water well system operated with the DPW Water - Anthracite Sand Filter / Ultraviolet Light (ASF/UV) disinfection system throughout the period. On November 2 the #1 Sterilizer sensor was changed to insure accuracy in the intensity reading. On November 5 a new bulb was installed in the #1 Sterilizer as a result of a low intensity alarm. Following the installation the intensity reading approached 100%. The system was down 23 hours 35 minutes beginning at 15:10 on December 7 and resuming operation at 14:45 on December 8 to repair an underground DPW leak. Daily operational data are collected by the Shipping Department and reported to the Environmental Affairs Department. The total monthly and quarterly volumes of water injected as well as the month end water level in the Water Level Control Tank are: INJECTED WATER TOTALS DPW WATER GALLONS CONDENSATE GALLONS TOTAL GALLONS AVERAGE GPM TANK LEVEL FEET, MSL Nov-99 397,000 0 397,000 9.2 14.4 Dec-99 429,970 0 429,970 9.6 14.7 Jan-00 373,410 0 373,410 8.4 14.7 TOTALS 1,200,380 0 1,200,380 Withdrawal Well System The Withdrawal Well System operated the entire period. The withdrawal water well pumps are monitored daily by the area Maintenance Department and preventative maintenance work is performed is needed. The total monthly and quarterly withdrawal water volumes for the period are: WITHDRAWAL WATER TOTAL S SAND FORMATION GALLONS CROATAN FORMATION GALLONS TOTAL GALLONS AVERAGE GPM Nov-99 477,734 273,582 751,316 17.4 Dec-99 464,973 288,716 753,689 16.9 Jan-00 523,176 292,029 815,205 18.3 TOTALS 1,465,883 854,327 2,320,210 2 Some additional short periods of planned downtime for preventative maintenance, pipe header cleaning, and troubleshooting on individual pumps in the fourteen well system were experienced. Details of these activities are: Air Compressor for the Withdrawal Well Pumps Operation of the air compressor system was normal during the period. Confined Sand Formation Withdrawal Well (SWW) Pumps SWW-1: On 11/9 the pump plugged and was changed. On 1/25 the pump was shaken to start. SWW-2: On 1/11 the pump stopped and was shaken to start. On 1/12 the pump was replace. SWW-3: Pump operated without incident. SW W-4: On 1/11 pump would not start. Replaced with a rebuilt pump. SWW-5: On 11//1 had to shake pump to start. On 12/8 pump would not start changed pump. On 1/4 had to shake pump to start, pulled and cleaned pump. SWW-6: On 11/1 the pump stopped and was shaken to start. On 11/24 replaced totalizer. SWW-7: On 11/1 the pump stopped and was shaken to start. Croatan Formation Withdrawal Well (CWW) Pumps CWW-1: Pump operated without incident. CWW-2: On 11/3 the pump would not pump. On 11/5 the pump was replaced. On 11/8 pump failed and was replaced. On 12/16 replaced totalizer. CWW-3: Pump operated without incident. CWW-4: On 11/2 the pump was shaken to start. On 11/3 the pump was shaken to start. On 11/23 pulled and cleaned pump. On 12/8 pump would not pump, changed out pump. CWW-5: On 11/16 pump not working changed pump. CWW-6: On 12/8 cleaned the pump. On 12/14 the pump stopped and was shaken to start. CWW-7: On 12/8 cleaned the pump. 3 February 22, 2000 PCS Phosphatece AURORA DIVISION P.O. BOX 48, AURORA, NC 27806 MARK MILLIGAN '-' GROUND WATER c7 nz L. a DENR = =. _-1 1636 MAIL SERVICE CENTER ` RALEIGH, NC 27626-1636 Subject: Underground Injection Control Program Fourth Quarter Groundwater Monitoring Report November 1999 - January 2000 Injection Well Permit #WI0700012 Tank Farm Remedial Action System Beaufort Co. Dear Mark: Please find the subject groundwater monitoring report attached. This includes the sampling and reporting requirements of the above referenced permit, Part V, Section B 1 as well as the reporting requirements of the overall Tank Farm Remedial Action Plan. Enclosed are: a) Form GW-59 for injection well CIW7 and monitor well MWTF1CR, b) Form GW-59 for each of the fourteen withdrawal wells, c) Form GW-59 for monitor wells MWTF1A and MWTF1B, d) Form GW-59 for the WLCT, e) piezometer level monitoring field sheet, and f) the summary operational and maintenance report. Please do not hesitate to contact me at (252) 322-8283 if you have any questions regarding this information. Sincerely, ,0 D. Daniel Winstead III Environmental Engineer Environmental Affairs Attachments pc: Willie Hardison / Keith Starner — DWQ- GWS, WaRO (w/attch) bpc: TXi. L. Baker / 12-01-008-03-002 (w/ attch) J. A. Hardy / R. B. Lee / T. W. Davis (w/ attch) R. A. Allen / T. Lewis (w/attch) D. D. Winstead / 00-24-000 (w/o attch) W. A. Schimming (w/o attch)