Loading...
HomeMy WebLinkAboutWI0600080_Correspondence_20150310ATA NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor March 10, 2015 Mr. Gregory Bean, Director of Public Works DPW Bldg 3-1631 Butner Road Fort Bragg Fayetteville, NC 28310 Subject: Completion of 5I Injection Well Permit WI0600080 Pope AAF, Site ST008, Fort Bragg, NC Cumberland County Dear Mr. Bean: Donald R. van der Vaart Secretary On October 19, 2011, the Water Quality Regional Operations Section (Former Aquifer Protection Section) issued a 5I groundwater remediation permit to the above for the remediation of contaminated groundwater located at Site ST008, Pope Army Airfield, Fort Bragg, NC 28310. Expiration date for the permit was September 30, 2014. A review of the file indicates the Final Project Evaluation (FPE) received April 26, 2013, indicated an exceedance of sulfate in monitoring well MW-HF1 (848 mg/L). The MCL for sulfate per 15A NCAC 2L .0200 is 250 mg/L. This exceedance in sulfate is a result of the injection of BOS as the concentration level increased after the injection, and was trending higher when the well was last sampled on October 31, 2012. Before closing out this permit and issuing a Completion Letter, we will need to receive a groundwater sample collected from this well. Injectants and related reaction byproducts must attenuate to pre -injection concentrations or groundwater standards specified in rule 15A NCAC 02C .0202, whichever is greater, in order for this permit to be closed. Otherwise, corrective action as described Part VIII shall be required. Please contact me at 919-807-6406 or Thomas Slusser , UIC Program Manager, at 919-807-6407, if you have any questions. Best Regards, Michael Rogers, P.G. (NC & 'L) Hydrogeologist Water Quality Regional Operations Section Division of Water Resources cc: Belinda Henson, WQROS - Fayetteville Regional Office Central Office File, WI0600080 Paul Farris, AECOM, 1600 Perimeter Park Drive, Suite 400, Morrisville, NC 27560 1636 Mail Service Center, Raleigh, North Carolina 27699-1636 Phone: 919-807-6464 \ Internet: http://www.ncwater.org An Equal Opportunity \ Affirmative Action Employer — Made in part by recycled paper INJECTION EVENT RECORD RECEtVEDIDENRIDWQ MAY 25 2012 Aquifer Protection Section North Carolina Department of Environment and Natural Resources - Division of Water Quality Permit Number (A.M 0 (, 0 0 0 80 l . Permit Information MI. acepr, #e.gtrt Permittee Pore Army .4;r 4;d Facility Name no 4/,I 3-1631 pomr FacilityAddres Fae#-tsv;l+a 'VC 2. Injection Contractor Information 11,5T FI?✓%Yonpme...fal Injection Contractor / Company Name Street Address /Y1 City GGr Mtu;nntr A 1�C ; (/0 3 State Zip C (S ) 8'IC - 5/900 Area code - Phone number [ -)1 6jo QS) 3. Well Information F•%s $ Number of »efl used for injection y 9 point/t'P g-Fifl-1 iI,a XP3- NF-14 names PS- EA -I 14e.. SRO' Ski 'I/SPS-1b-I 4... sea -I !I -TO - 14". rya-ief -ii Were any new wells installed during this injection event? ❑ Yes 2 No If yes, please provide the following information: Number of Monitoring Wells Number of Injection Wells Type of Well Installed (Check applicable type): ❑ Bored ❑ Drilled ❑ Direct -Push ❑ Hand -Augured © Other (specify) an 1.144.4 Please include two copies ofform GW-1b for each well installed. ax 4 )� J1 % ri ach hs/ irce Volume Injected per ( y - i D . w//Q n S 5. Injection History Injection date(s) It/21/it Ark I2/2/u1 Injection number (e.g. 3 of 5) /0 Is this the last injection at this site? J Yes ❑ No I DO HEREBY CERTIFY THAT ALL THE INFORMATION ON THIS FORM IS CORRECT TO THE BEST OF MY KNOWLEDGE AND THAT THE INJECTION ?S PRFORMED WITHIN THE STANDA T IN THE PERMIT. SIINJECTION CONTRACTOR 31i D TE AJ PRINT NAME OF PERSON PERFORMING THE INJECTION Submit the original of this form to the Division of Water Quality within 30 days of injection. Attn: UIC Program, 1636 Mail Service Center, Raleigh, NC 27699-1636, Phone No. 919-733-3221 Form UIC-IER Rev. 07/09 I Page 1 of 1 Date: May 23, 2012 To: UIC Program From: Jon Kucera, URS Subject: Injection Event Records Please find the enclosed injection event record forms for UIC permits numbers WI0600079 and • WI0600080 for injections performed at Pope AAF. Should you have any questions, please do not hesitate to call me at (919) 461-1349. RECEIVEDIDENRIDWQ MAY 2 5 2012 Aquifer Protection Section PACommon_Projects\PopeAFBVnstallation Restoration\PBC\6.0 UST Sites\SS00T5 Correspondence\Pope AFBVnjection Event Records.doc 5232012 Rogers, Michael From: Farris, Paul [paul.farris@aecom.com] Sent: Thursday, January 15, 2015 10:17 AM To: Rogers, Michael Cc: Berra, Brett; Kucera, Jon Subject: contact information for Pope AAF (Ft. Bragg) UIC permit holders at sites SS019 and ST008 Attachments: WI0600079 Permit Transmittal letter.docx; W10600080 Permit Transmittal letter.docx Good Morning Michael, I'm following up on two requests forwarded to me from you in the past several weeks regarding the owner of injection permits associated with Pope Army Airfield sites SS019 and ST008. Apologize for the delay in responding.... I am attaching copies of the Permit Transmittal Letters I have on file for each site issued by David Goodrich. Each shows the owner as Gregory Bean. I don't have a phone number or email for him, but the I have provided contract information for the people that work under/with Mr. Bean at Ft. Bragg DPW and were familiar with the project (Christy Lowery, Steven Harris, and their supervisor Audrey Oxendine). Hope this information helps. Thanks. Paul Mr. Gregory Bean, Director of Public Works DPW Bldg 3-1631 Butner Road, Fort Bragg Fayetteville, North Carolina 28310 Christie Lowery IRP/CC Program Support Environmental Compliance Branch DPW Bldg 3-1137, Fort Bragg, NC 28310 Phone: 910-907-3645 Fax: 910-396-4188 christie.r.lowery.ctr@mail.mil STEVEN HARRIS IRP, MMRP and Storage Tank Program Manager, LEED AP (BD+C) Environmental Compliance Branch Bldg 3-1338 phone: (W) 910-396-7432 (C) 910-964-1577 Fort Bragg, NC 28310 steven.harris 11.civ@mail.mil Ms. Audrey D. Oxendine audrey.oxendineCaus.army.mil James Brown (UST Section regulator in FRO also familiar with the project). james. brownncden r.gov>, Paul Farris, PG Project Manager/Geologist - Geosciences Group 1 D 1-919-461-1468 C 1-919-630-8041 pau I.farrisafaecom.com AECOM 1600 Perimeter Park Drive, Suite 400 Morrisville, NC 27560 T 1-919-461-1100 F 1-919-461-1415 www.aecom-com AECOM and URS have joined together as one company This e-mail and any attachments contain AECOM confidential information that may be proprietary or privileged. If you receive this message in error or are not the intended recipient, you should not retain, distribute, disclose or use any of this information and you should destroy the e-mail and any attachments or copies. NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary October 19, 2011 Mr. Gregory Bean, Director of Public Works DPW Bldg 3-1631 Butner Road, Fort Bragg Fayetteville, North Carolina 28310 Ref: Issuance of Injection Permit WI0600080 Pope Army Airfield Site ST008 Fayetteville, Cumberland County, North Carolina. Dear Mr. Bean: In accordance with the application received on August 11, 2011, and the supporting data received August 26, 2011, August 29, 2011, September 30, 2011, and October 12, 2011, we are forwarding permit number WI0600080. This permit is to inject BOS 200 and Trap & Treat Bacteria Concentrate to remediate groundwater contaminated with Number 2 Fuel Oil at the facility referenced above. This permit shall be effective from the date of issuance until September 30, 2014, and shall be subject to the conditions and limitations stated therein, including the requirement to submit a fmal project evaluation as stated in PART VII — MONITORING AND REPORTING REQUIREMENTS. Please read the entire permit to ensure that you are aware of all compliance requirements of the permit. You will need to notify this office by telephone 48 hours prior to initiation of operation of the facility. In order to continue uninterrupted legal use of the injection facility for the stated purpose, you must submit an application to renew the permit 120 days prior to its expiration date. Please contact me at (919) 715-6162 or at david.goodrich@ncdenr.gov if you have any questions about your permit. Best Regards, David Goodrich Hydrogeologist cc: Art Barnhardt, Fayetteville Regional Office Jon Kucera, URS Corporation -North Carolina, 1600 Perimeter Park Drive, Morrisville, NC 27560 Art Shatter / Martha Morgan, NCDWM Superfund Section, 1646 Mail Service Center, Raleigh, NC 27699-1646 WI0600080 Permit File AQUIFER PROTECTION SECTION 1636 Mail Service Center, Raleigh, North Carolina 27699-1636 Location: 2728 Capital Boulevard, Raleigh, North Carolina 27604 Phone: 919-733-3221 l FAX 1: 919-715-0588; FAX 2: 919-715-60481 Customer Service: 1-877-623-6748 Internet: www.ncwaternuality.orq An Equal Opportunity ; Affirmative. Action Employe' North Carolina Naturally August 29, 2011 UIC Program ATTN: Mr. David Goodrich Aquifer Protection Section North Carolina DENR-DWQ 1636 Mail Service Center Raleigh, NC 27699-1636 RECEIVED iDENRIDWQ Aquifer Protection Section AUG 302011, RE: Underground Injection Control (UIC) Permit Applications (WI0600079 & WI0600080) Pope Army Air Field Sites ST008 and SS019 Pope AAF, Fayetteville, North Carolina Mr. Goodrich: Please:find the enclosed three copies of revised figures for the UIC permit applications for injection of BOS 200® to treat petroleum impacts within the subsurface of the above referenced properties. The application was completed by URS Group, Inc. — North Carolina on behalf of Pope AAF. If you have any questions regarding this submittal please do not hesitate to contact Jon Kucera at (919) 461-1349. Sincerely, URS Group, Inc. SGn `/-tcrs: I {oA Jk Jon Kucera, PE Project Manager URS Group, Inc. 1600 Perimeter Park Drive, Suite 400 Morrisville, NC 27560 Tel: 919.461.1100 Fax: 919.461.1415 1 /J74 N J 71 L RIVED • der Pratedion Section NUG 3 Z011. SCALE IN FEET a: a 0 2000 JJ • 'OthIcti.41" QUADRANGLE LOCATION SOURCE: USGS 7.5' TOPOGRAPHIC QUADRANGLE OVERHILLS, NC — DATED 1957, PHOTOREVISED 1971 �\ y FIGURE 1. LOCATION MAP SITE ST008 POPE ARMY AIR FIELD FAYETTEVILLE, NORTH CAROLINA Prepared for: DRAWN BY: TSH DATE: 02/12/09 PROJECT NO. uIs RDV, NORM CAROLINA 27580 I Fig. Goodrich, David From: Stephanie_White@URSCorp.com Sent: Monday, August 29, 2011 9:20 AM To: Goodrich, David Subject: RE: Additional Information Requested for Pope Army Airfield Applications (WI0600079 & W I0600080 ) Mr Goodrich, We will be properly abandoning each pushpoint with grout after injection (assuming the holes stay open and do no collapse). Thanks again! Hope you didn't have too much hurricane damage! Stephanie Danielle White GIT URS Corporation - North Carolina 1600 Perimeter Park Drive Morrisville, NC 27560 (919) 461-1505 (direct) (919) 390-4222 (cell) (919) 461-1415 (fax) stephanie white(curscorp.com This e-maii and any attachments contain URS Corporation confidential information that may be proprietary or privileged. If you receive this message in error or are not the intended recipient. you should not retain. distribute, disclose or use any of this information and you should destroy the e-mail and any attachments or copies. "Goodrich, David" <david.goodrichl ncdenr.gov> 08/29/2011 08:21 AM To "Stephanie White(WURSCorp.com" <Stephanie White(WURSCorp.com> cc Subject RE: Additional Information Requested for Pope Army Airfield Applications (W10600079 & W10600080) Ms. White, Thank you for sending me the requested information. I also wanted to confirm that the pushpoints will be properly abandoned by grouting. Could you confirm this for me? Thank you. David Goodrich Aquifer Protection Section Central Office From: Stephanie White©URSCorp.com [mailto:Stephanie White@URSCorp.com] Sent: Friday, August 26, 2011 4:17 PM 1 To: Goodrich, David Cc: Jon Kucera@URSCorp.com; Paul Farris©URSCop.com; Mike Ranck©URSCorp.com Subject: Re: Additional Information Requested for Pope Army Airfield Applications (WI0600079 & WI0600080) Mr. Goodrich, Please find the attached revised figures for Pope Army Air Field Site SS019 and Site ST008 UIC Permit Applications, which have been modified per your comments dated August 15, 2011 (included). URS will also be sending three hard copies of these revised figures to your attention next week. If you have any questions regarding this submittal or the hard copies to be sent Monday, please feel free to contact me. Thanks so much, and I hope you have a nice weekend! Stephanie Danielle White G IT URS Corporation - North Carolina 1600 Perimeter Park Drive Morrisville, NC 27560 (919) 461-1505 (direct) (919) 390-4222 (cell) (919) 461-1415 (fax) stephanie white@urscorp.com This e-mail and any attachments contain URS Corporation confidential information that may be proprietary or privileged. If you receive this message in error or are not the intended recipient, you should not retain, distribute, disclose or use any of this information and you should destroy the e-mail and any attachments or copies. 2 . Goodrich, David From: Goodrich, David Sent: Tuesday, August 16, 2011 12:54 PM To: 'Jon_Kucera@URScorp.com' Subject: Another question about the Pope Army Airfield permit applications Dear Mr. Kucera: It is my understanding that the injection treatments at the two sites will be performed using push technology. I wanted to confirm that the resulting boreholes will be abandoned using a cement or bentonite slurry. Thank you. Regards, David Goodrich Aquifer Protection Section Central Office 1 Goodrich, David From: Goodrich, David Sent: Monday, August 15, 2011 3:23 PM To: 'Jon_Kucera@URScorp.com' Subject: Additional Information Requested for Pope Army Airfield Applications Attachments: Additional Information1 Pope Army Airfield.docx Mr. Kucera: The Aquifer Protection Section is reviewing the two applications for groundwater remediation at the Pope Army Airfield facility at Fort Bragg. We are requesting additional information, and I am attaching our request letter herewith to save time. Please contact me by email, or by telephone at (919) 715-6162 if you have any questions regarding these requests. Thank you. Regards, David Goodrich Aquifer Protection Section Central Office 1 wA North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Mr. Jon Kucera, Project Manager URS Corporation — North Carolina 1600 Perimeter Park Drive Morrisville, NC 27560 Dear Mr. Kucera: Division of Water Quality Coleen H. Sullins Dee Freeman Director Secretary August 15, 2011 Subject: Additional Information Request WI0600079 & WI0600080 Permit Applications Pope Army Airfield Site SS019 and ST008 Groundwater Remediation Injection Wells Cumberland County The Non -Discharge Permitting Unit is reviewing the subject permit application packages dated August 2, 2011. Additional information is required before we may continue our reviews. Please address the following items no later than September 15, 2011: 1) In the application submitted for Site SS019 and in the application submitted for Site ST008, the site map submitted as Attachment H (2) does not appear to have existing or proposed injection wells or well field(s); the locations of any existing sources of potential or known groundwater contamination, including waste storage, treatment or disposal systems within'/a mile of the injection well or well system; all surface water bodies within ''A mile of the injection well or well system; and all existing or abandoned wells within''% mile of the injection well(s) which penetrate the proposed injection zone, including, but not limited to, monitoring wells and wells proposed for use as injection wells. 2) In the application submitted for Site SS019 and in the application submitted for Site ST008, the potentiometric surface map submitted as Attachment H (3) does not appear to have existing or proposed injection wells. 3) In the application submitted for Site SS019 and in the application submitted for Site ST008, the contaminant plume map submitted as Attachment H (4) does not appear to have existing or proposed injection wells. 4) In the application submitted for Site SS019 and in the application submitted for Site ST008, the cross- section(s) to the known or projected depth of contamination submitted as Attachment H (5) do not appear to include the horizontal and vertical extent of the contaminant plume, including isoconcentration lines, or existing and proposed injection wells. Please submit modified maps which include this information. AQUIFER PROTECTION SECTION 1636 Mail Service Center, Raleigh, North Carolina 27699-1636 Location: 2728 Capital Boulevard, Raleigh, North Carolina 27604 Phone: 919-733-3221 \ FAX 1: 919-715-0588; FAX 2: 919-715.60481 Customer Service: 1-877-623-6748 Internet www.ncwateraualitv.orq An Equal Opportunity t Affirmative Action Employer lvor nCarolina t r F CEnil/ 1 Please be aware that you are responsible for meeting all requirements set form in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the responsibility of the applicant. Please reference the subject application number when providing the requested information. Three copies of all revised and/or additional documentation should be signed, sealed, dated, and submitted to my attention at the address at the bottom of the cover page of this letter. Please note that failure to provide this additional information on or before the above requested date may result in your application being returned as incomplete. If additional time is necessary, the application may be withdrawn to avoid being returned as incomplete. Either the applicant or the applicant's consultant may request withdrawal by email message or letter if this is desired. If you have any questions regarding this request, please do not hesitate to contact me at (919) 715-6162. Thank you for your cooperation. Sincerely, David Goodrich Aquifer Protection Section cc: Gregory Bean, Director of Public Works, DPW Bldg 3-1137, Fort Bragg, Fayetteville, NC 28310 Art Barnhardt, Fayetteville Regional Office, Aquifer Protection Section APS Central Files NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary August 15, 2011 Gregory Bean — Ft. Bragg PWC Pope Army Airfield DPW Bldg 3-1137 Ft. Bragg, NC 28310 Dear Mr. Bean: Subject: Acknowledgement of Application No. WI0600080 Pope Army Airfield 2 Injection In situ Groundwater Remediation Well (5I) System Cumberland County The Aquifer Protection Section acknowledges receipt of your permit application and supporting documentation received on August 11, 2011. Your application package has been assigned the number listed above, and the primary reviewer is David Goodrich. Central and Fayetteville Regional Office staff will perform a detailed review of the provided application, and may contact you with a request for additional information. To ensure maximum efficiency in processing permit applications, the Aquifer Protection Section requests your assistance in providing a timely and complete response to any additional information requests. Please note that processing standard review permit applications may take as long as 60 to 90 days after receipt of a complete application. If you have any questions, please contact David Goodrich at (919) 715-6162 or david.goodrich@ncdenr.gov. Sincerely, for Debra J. W3�tts Groundwater Protection Unit Supervisor cc: Fayetteville Regional Office, Aquifer Protection Section Jon Kucera — URS Corporation - 1600 Perimeter Park Drive, Morrisville, NC 27560 Permit File WI0600080 AQUIFER PROTECTION SECTION 1636 Mai! Service Center, Raieiat,. North Carolina 27699-1636 Location: 2728 Capital Boulevard. Raleigh. North Carolina 27604 Phone 916-733-3221 i FAX 1: 919-715-058E, FAX 2: 919-715-80461 Customer Service: 1-67'-623-674E Internet www.newaterauality.orq 4n Eouai Opportunity 1 Affirmative Action Employe! Unc orth C aroiin F ads a''