Loading...
HomeMy WebLinkAboutWI0600055_Site Plans/Maps_20100427IN KY AL GA jr ts Site Location Map Former Abbott Facility Laurinburg, North Carolina Laurinburg, NC Topographic Quadrangle (1978) 0 2,000 4,000 Feet March 2010 60135880.300 Figure 1 A=COM AECOM North Carolina Inc. 7041 Old Wake Forest Rd, Suite 103 Raleigh, NC 27613-3013 Phone: (919) 872-6600 Fax: (919) 872-7996 Web: http://www.aecom.com LEGEND IiJ(IIIt11t1 RAILROAD TRACKS • FENCE LINE - NCDOT —•— — — — FENCE LINE TREE LINE GROUNDWATER REMEDIATION LINE _ = DRAINAGE LINE BIOREMEDIATION MW-101A MONITORING WELL (POST - 2002 ) RECOVERY SYSTEM MW-25B MONITORING WELL (PRE-2002) ABANDONED MONITORING WELL INACTIVE GROUNDWATER RECOVERY WELL 150 0 51) NOTES 1. WELLS LABELED WITH "A" SUFFIX MONITOR SHALLOW GROUNDWATER AT DEPTHS <30 FEET BGS. PROGRESSIVELY DEEPER MONITORING INTERVALS ARE SHOWN AS "B", "C", AND "D" LABELED WELLS. 2. WELL MW-105C WAS INSTALLED IN FEBRUARY 2010 AND HAS NOT BEEN SURVEYED. ITS LOCATION IS BASED ON FIELD MEASUREMENTS. ® RR S!G BMW-105C 150 SCALE IN FEET: 1"=150' SOURCE: BASE MAP PROVIDED BY EXCEL CIVIL & ENVIRONMENTAL ASSOCIATES, PLLC. MW-19D MW-19B MW-22B MW-22D RAW MATERIALS SHED #2 TOXIC! OXIDIZER RAW MATERIALS SHED #1 FLAMMABLES—� W-21BS MW-18B MW-18D MW-102B -102C MW-102A MW-103C \ MW-103B MW-104C MW-104B MW-10D MW-108 S MW-6B FORMER SOLVENT WASTE PIT ( APPROXIMATE LOCATION ) MW-100A MW-100B MW-16D ®R MW-2013 :. 8 R1490 0 0-`0�0-0-0`0_0~0~0-0�0`0-0�0�,0� • .. US 401 BYPASS MW-11 MW-11 D ova—ono—o—o—o_o`o� —� 0 8 g it N 0 O z W 0. z 0 Y Ko CHECKED BY: APPROVED BY: FIGURE NUMBER: 2 SHEET NUMBER: B100127B LEGEND • MW-101A • MW-25B ® RW-4 219.21 220 FENCE LINE - NCDOT FENCE LINE TREE LINE GROUNDWATER REMEDIATION LINE DRAINAGE LINE BIOREMEDIATION MONITORING WELL ( POST -2002) RECOVERY SYSTEM MONITORING WELL ( PRE - 2002 ) ABANDONED MONITORING WELL INACTIVE GROUNDWATER RECOVERY WELL GROUNDWATER ELEVATION (FT MSL ) GROUNDWATER EQUIPOTENTIAL CONTOUR (DASHED WHERE INFERRED ) (FT MSL) GENERALIZED GROUNDWATER FLOW DIRECTION NOTES 1. EQUIPOTENTIAL CONTOURS FOR SHALLOW GROUNDWATER ARE BASED ON WATER LEVELS FROM WELLS SCREENED < 30 FEET BGS. co 120 0 120 SCALE IN FEET : 1" = 120' EMPLOYEE PARKING LOT MW-22B ®MW-22D BLOCK MW-21B GUARD HOUSE MY% 248 HAZARDOUS WASTE SHED MW-18B 218.08 MW-18D MW-104C MW-104B WATER TANK MW-8B MW-8D MW-103C MW-103B MW-104A 220.35 MW-10D MW-10B 219.62 MW-16B 218.70 MW-100A 220.86 ` MW-100B MW-101 B "- MW-25B srp� ' MW-102B .\\ 219.21 g.,2A -102C ®RW-5 Z MW-103A 220.69 MW-20B Us 401 BYPASS oO ® MW-138 219.39 rle 0 0__ g g 1 A. a 8 S' 0 o W DRAWN BY: KLR CHECKED BY: APPROVED BY: E3 o 0 0 PROJECT NUMBER: 60135880.300 0 m N 0 N 11 FIGURE NUMBER: 3 SOURCE: BASE MAP PROVIDED BY EXCEL CIVIL & ENVIRONMENTAL ASSOCIATES, PLLC. ............. r goo r SHEET NUMBER: B100128B LEGEND FENCE LINE NCDOT FENCE LINE TREE LINE GROUNDWATER j MW-5 REMEDIATION LINE I DRAINAGE LINE BIOREMEDIATION MW-101A MONITORING WELL ( POST - 2002 ) RECOVERY SYSTEM MW-25B MONITORING WELL ( PRE -2002) ABANDONED MONITORING WELL INACTIVE GROUNDWATER RECOVERY WELL GROUNDWATER ELEVATION (FT MSL ) GROUNDWATER EQUIPOTENTIAL 218 . CONTOUR ( DASHED WHERE INFERRED ) (FT MSL) GENERALIZED --)1I10- GROUNDWATER FLOW DIRECTION ® RW-4 218.47 NOTES 1. EQUIPOTENTIAL CONTOURS FOR DEEP GROUNDWATER ARE BASED ON WATER LEVELS FROM WELLS SCREENED WITHIN THE DEPTH INTERVAL OF 30-78 FEET BGS IN THE AQUIFER. VARIATIONS IN POTENTIOMETRIC HEADS ARE EVIDENT BETWEEN SOME OF THE "B", "C", AND "D" WELL COUPLETS. IN THESE CASES, 2 DATA FROM THE "C" WELL WERE USED FOR GENERAL CONTOUR INTERPRETATION. 120 0 120 SCALE IN FEET : 1" = 120' SOURCE: BASE MAP PROVIDED BY EXCEL CIVIL & ENVIRONMENTAL ASSOCIATES. PLLC. EMPLOYEE PARKING LOT MW-19D 216.10 BLOCK MW-19B ♦ MW-22B ®MW-22D ♦ MW 21B ♦♦ • • MW-24B- HAZARDOUS WASTE SHED MW-104A • • MW-18B • MW-18D • 216.20 MW-16B WATER TANK MW-101 B 218.47 MW-103C 217.50 MW-103B 218.45 216.43 • • _• MW-100B 218.93 MW-13B MW-20Dts MW-20B US401 BYPASS °—°_'°—°—• I I / I 1 c g o E il zz g CHECKED BY: APPROVED BY: W 2 Z 5 Y e O 0 cQ cLa LA U 0 QUO �a 0 O 7, L D N la. W 1 0 IeCCM am 0 I- hi m 3 LD > E -2 W 0 Z 0 Z W I- 0 PROJECT NUMBER: 60135880.300 0 m M FIGURE NUMBER: 4 SHEET NUMBER: B1001298 ® RW-4 '.2CC LEGEND FENCE LINE - NCDOT FENCE LINE TREE LINE GROUNDWATER REMEDIATION LINE DRAINAGE LINE BIOREMEDIATION • MW-101A MONITORING WELL ( POST -2002) RECOVERY SYSTEM • MW-25B MONITORING WELL (PRE-2002) ABANDONED MONITORING WELL INACTIVE GROUNDWATER RECOVERY WELL TRICHLOROETHYLENE CONCENTRATION (ug/L) TRICHLOROETHYLENE CONTOUR (DASHED WHERE INFERRED) (ug/L) NOTES 1. ISOCONCENTRATION CONTOURS REPRESENT THE TCE PLUME IN THE SHALLOW ZONE OF THE AQUIFER FROM THE WATER TABLE TO DEPTHS UP TO 30 FEET BGS. 120 0 120 SCALE IN FEET : 1" = 120' SOURCE: BASE MAP PROVIDED BY EXCEL CIVIL & ENVIRONMENTAL ASSOCIATES, PLLC. p/ MW-5 7 EMPLOYEE PARKING LOT r MW-19D % MW-19B <1 BLOCK MW-21B GUARD HOUSE HAZARDOUS WASTE SHED WATER TANK BLOCK 01. MW-101 B IMW-8B MW-8D MW-102C MW-104C MW-104B MW-104A 2.4 MW-10D MW-10B MW-16B MW-16D ®RW-7 •— ,_, — — MW-20D®MW-20B W-6 2P-7 MW 27D/ MW-102A 790 / MW-102B ° 0_0-0-0-0—.0_0'0 MW-22B ® MW-22D MW-18B <1 MW-18D 3.5 / MW-13B --- 0-0-0--- 0_0-_0---.0--- 0--0`010`0-0-�0-0`0_ US 401 BYPASS 0 °—O--- O0°- 0 DESIGNED BY: Y io Q U x po K 1- ir4 W w0 Q N 3 � O 0 W Z LI- W cam o z0> O O J Z W J C< i— _ PROJECT NUMBER: 60135880.300 0 rn 0 FIGURE NUMBER: 5 SHEET NUMBER: C100130B LEGEND S MW-101A S MW-25B • RW-4 FENCE LINE NCDOT FENCE LINE TREE LINE GROUNDWATER REMEDIATION LINE DRAINAGE LINE BIOREMEDIATION MONITORING WELL ( POST - 2002 ) RECOVERY SYSTEM MONITORING WELL (PRE -2002) ABANDONED MONITORING WELL INACTIVE GROUNDWATER RECOVERY WELL TRICHLOROETHYLENE CONCENTRATION (ug/L) TRICHLOROETHYLENE CONTOUR (DASHED WHERE INFERRED) (ug/L ) NOTES 1. ISOCONCENTRATION CONTOURS REPRESENT THE TCE PLUME IN THE DEEPER AQUIFER ZONES AT DEPTHS > 30 FEET BGS AND < 78 FEET BGS. 120 0 120 SCALE IN FEET : 1" = 120' SOURCE: BASE MAP PROVIDED BY EXCEL CIVIL & ENVIRONMENTAL ASSOCIATES, PLLC. EMPLOYEE PARKING LOT MW-19D 7.7 BLOCK MW-21 B GUARD HOUSE 3.0 va�a=o aa,:� MW-22B ® MW-22D WATER TANK MW-101 B 1,100 / MW-8B MW-8D MW-102C <5 MW-1 03C 23 MW-103B — 27 MW-103A— MW-104A MW-104B MW-10D MW-10B -16B MW-113D RW-7 MW-18B S MW-18D MW-100A MW-100B <500 MW-101 A MW-25B� <MW-20D MW-20B --_00��0.L US 401 BYPASS 19 MW-13B D 00_ z o et to a o E w 0 0 z Z' ` tn o DRAWN BY: KLR CHECKED BY: - . . & 1 (2 LAW Z Q N 0 0 CD N Z Ce DLL W D m 0Qw ZW0 La LAZ U CI F-- 0 N_ II FIGURE NUMBER: 6 SHEET NUMBER: C100131B LEGEND 11 WATER TANK MW-8B S MW-8D - 250-GALLON DIESEL FUEL TANK (AST) • • RW-4® • i • MW 23D MW-23B MW-100A MW-100B APPROXIMATE BOUNDARY OF AREA FOR ABC® ELECTRON DONOR INJECTIONS TCE ISOCONCENTRATION (ug/L) IN SHALLOW GROUNDWATER (NOV. 2009 ) • PROPOSED ABC® INJECTION BORING • • \ • • • • f i • MW- 101E • • MW-25B NO MW-101A • V„." •'�, •%, �� • INJECTION ZONE C / / • / MW-102C • MW-102A MW-102B \ MW-27D i RW-5 30 0 INJECTION ZONE A` INJECTION ZONE B 30 SCALE IN FEET : 1" = 30' SOURCE: BASE MAP PROVIDED BY EXCEL CIVIL & ENVIRONMENTAL ASSOCIATES. PLLC. AECOM AECOM North Carolina, Inc. RALEIGH. NORTH CAROUNA 27615 PHONE: (919) 872-6600 FAX: (919) 872-7996 WEB: HTTP://WWW.AECOM.COM APPROXIMATE ABC® ELECTRON DONOR INJECTION AREA SOLVENT PLUME REMEDIATION Former Abbott Facility Laurinburg, North Carolina DRAWN BY: KLR DATE: 3/29/10 PROJECT NUMBER: 60135880.300 FIGURE NUMBER: 7 DRAWING NUMBER: 8100132A DEPTH BELOW GROUND SURFACE (FT.) '0 2 of 8 f I I 9 LOCALLY UNCIFF!RENTIATED gi II; 0 0 0 8 0 SNOLLVIA32188V 0 cn g9i I' ' a li 1 i hi Est tt N4 t } 4 gift t jhi d11 } ssitiF L u', , 3a �'� d G 6**EMdns Mb.. 36d06 ighs TOE MAX oohs p 75; siins3a `JNI1S31 32100 1IOS 0 A O 10 0 10 VERTICAL SCALE (FT. ) m A 2 5 0 L I J J -3 J I � I a 0 6 a 0 8 I I I 0 5 3 N 8 8 3 5 S S 0 K H S 8 K 9 DEPTH BELOW GROUND SURFACE (FT.) il._I_III •I:1:1:1:1:1.11 .1:1:1,1:1:1 1 i :I:I.1:I.I:I I:I:I' I:1;1. :1:1:1:1:1 1:1 I; I: I; I:I:1; 1. 1:1:1:1!1:11: .I: I: I:. I: I.I.I. I:I: 11.1:1.1:1: I:I:1.1:I:i.l; I:I:1 1:1:1:1:1; 1s1: i:l.1:1.1 : I:I:I 1:1; i:1: z 0 cn 0 0 0 m 0 Nn m z m 0 ! ! e ! e ! ! e . 0 . . ! iE es /4 is ! ! E.! ! ! ! ! e ! ! ! ! la y -;t !-.,1:: ri it ! ! ! ! ! ! ' ! ! ! ! ! e = i!f 4 if rir ! ! ! ! P. ! ! ! ! ! ! ! ! _ f., .� .J_•--__-., I.H. e s e!!! e 0!! e ". u1.::.v\,,'•r.,�.�,..,:*:+NSW 4NM,•..'Nn'Lv:R.A._..<+_,". �..-: v,•,.�.:..,:, Am I f M1 r is it i4 ii e e e!!! e!! 0 e e! l: `hVC'I'et*A '•"f1r!' l/ ,,AwkiMreW0/4lli1011.0 "/e1100400401 1 ii Co GENERALIZED CROSS SECTION OF EC DIRECT SENSING & SOIL BORING RESULTS NORTH PLUME SOURCE AREA Former Abbott Facility Lourtnburg, North Corolino SCALE: DATE: PROJECT NUMBER: AS SHOWN 3/24/10 60135880.200 A_"�OM AECOM North Carolina, Inc. RALEIGH. NORTH CAROLINA 27615 PHONE: (919) 872-6600 FAX: (919) 872-7996 WE6: HTTP://WWW.AECOM.COM DESIGNED BY: REVISIONS NO.: DESCRIPTION: DATE: BY: DRAWN Br KLR CHECKED BY: APPROVED BY.