Loading...
HomeMy WebLinkAboutNCS000402_34_Mebane Fire Department #3 Stormwater File_20210629Mebane Fire Station Stormwater Narrative By: Josh Johnson, P.E. The Mebane 3rd Fire Station site is 1.5 acres on the western side of Mebane Oaks Road. It is just to the south of the Agape Baptist Church and a Wal-Mart. The site is currently primarily farmland with an AT&T telephone pedestal near Mebane Oaks Road. The existing area does not include any impervious area outside of the telephone pedestal which will remain undisturbed. The proposed site will have 0.89 acres of impervious for an impervious percentage of 59.6%. The impervious area is made up of the building (constructed of brick with a metal roof), concrete sidewalk, concrete curb and gutter, and concrete paving. The building's use as a fire station requires wide turning radii to allow for fire trucks. The primary stormwater treatment devices on site are two bio-retention basins in the back of the site, a Storm Tech SC310 Underground Storage device with an isolator row in the front of the building, and a tree box filter in the front southeastern parking area. All of the devices are intended to treat the first 1" of rain. The bio-retention basins are designed in accordance with the NC BMP Manual. The Storm Tech SC 310 device is an underground detention device that provide water quality through it's isolator row. The SC 310 is also sized to hold the 10-year storm and therefore to reduce the peak runoff from the 10- year storm below the pre -development rates. The Tree Filter Box is an innovative design that is based on the proprietary Filterra Curb Inlet model and non-proprietary Tree Filter Boxes used in other areas of the country and installed in a streetscape project in the City of Greensboro. The Bio-Retention basins are each 12" deep and include upturned elbows to promote/force infiltration. Infiltration will also be increased by requiring the contractor to use construction techniques intended to promote infiltration including raking the bottom of the basin excavation, limiting equipment in the basin, and removal of sediment before construction. The Storm Tech SC 310 is currently in the final stages of testing for the NC DENR BMP Manual's proprietary device section through a flow rate through the isolator rows calculation. However, the device essentially already acts as a volumetric infiltration basin when designed to capture and hold the design storm. The Storm Tech device used on the site is designed to hold the 10 year storm volume of 600 cubic feet which is more than the 1" design storm. Additionally, by holding the 10 year storm volume, the peak flow will be reduced for the 10 year storm to less than or equal to the pre development runoff rates. The Tree Filter Box is directly upstream of the SC 310 and provides additional treatment of the areas that will eventually be treated by the SC 310. This was done in order to guarantee that the water quality needs on the project are met. The Tree Filter Box is designed as a high flow filter that will pass the 1" storm through the high flow filter media. The media will have a minimum permeability of 13"/hr and is designed to be approximately 95% sand and 5% organics. The design is intended to be very similar to the Greensboro Greenways Tree Boxes and will be an additional level of treatment. Bio-Retention Basin # 1 Drainage Characteristics Peak Flow Characteristics Drainage Area 0.29 ac 1-yr 24 Hour Intensity 4.61 in/hr Total Impervious Area 0.19 ac Pre -Development 1-yr 24 Hour Flow 0.40 cf/s Impervious % 66% Post -Development 1-yr 24 Hour Flow 0.97 cf/s Design Rainfall Depth 1.0 in Difference in Pre vs. Post Flow 0.6 cf/s Rain Garden Characteristics Top of Dam 619.00 Depth of Flow 1 0.08 Bypass Structure 618.50 Ponding Depth 12 1.00 Surface 617.50 Depth of Top Soil 4.00 0.33 Top of Fill Soil 617.17 Depth of Fill Soil 24 2.00 Top of Washed Sand 615.17 Depth of Washed Sand 4 0.33 Top of #57 Stone 614.83 Depth of #57 Stone 8 0.67 Bottom of #57 Stone 614.17 Size of Underdrains 4 0.33 Invert of Underdrains 614.50 Height of Upturned Elbow 15 1.25 Upturned Elbow into Yard Inlet 615.75 Runoff Calculations Soil Characteristics Surface Area 542 sf % Sand 88 % Max Ponding Area 1159 sf % Fines 10 % Min. Volume Required 677 cf % Organic 3 % Volume Provided 851 cf Soil Permeability 1.5 in/hr Underdrains P-Index Underdrains 2 Drawdown Time Above Surface 8 hr Underdrain Size 4 in Drawdown Time Below Surface 16 hr Factor of Safety 2 Total Drawdown Time 24 hr Underdrain Invert 614.50 elev Miscellaneous Information Groundcover Sod SHWT* 600 elev Bypass Structure Yard Inlet Distance from SHWT 14.17 ft Forebay? Grassed Swale? X DRAINAGE AREAS & IMPERVIOUS SURFACE Date: 10/28/13 Sheet: 2 Project: Fire Station Description: Bio-Retention 1 Design By: JSJ Checked By: JSJ Total DA = 0.29 acre Total Impervious Area = 0.19 DA Composition acre Comp a /a Impervious Area Pervious Area Impervious Area C Pre 0.29 0.00 0.30 0.0% Post 0.10 0.19 0.73 65.9% Change -0.19 0.19 0.43 65.9% C Values 0.30 0.95 "C" Values Rational Peak Flows Forest 0.06-0.2 Rational 1 Year 2 Year 10 Year 100 Year Grassed 0.1-0.35 Pre-Dev Flow 0.40 0.50 0.63 0.75 Paved 0.7-0.95 Post-Dev Flow 0.97 1.21 1.52 1.81 Gravel 0.7-0.85 Concrete 0.7-0.95 Building 0.8-0.95 Simple Method Runoff Volume Future Asphalt 0.7-0.95 Volume to Surface Area Rv Rainfall Hold Req'd BMP 0.95-1.00 Pre-Dev Flow 0.050 1.0 53 cf Post-Dev Flow 0.643 1.0 677 cf 677 cf Pre to Post Flow 0.643 1.0 677 cf 677 cf Routing Information Peak Outflow Maximum Max Elevation (cfs) Storage (cf) 2-year Storm 587.60 0.00 931.00 10-year Storm 587.71 0.00 1,099.00 See Attachments for complete 100-Year Storm 587.88 0.53 1,368.00 Routing Information. Alley, Williams, Carmen and King ,Inc. Burlington, N.C. Bio-Retention Basin # 2 Drainage Characteristics Peak Flow Characteristics Drainage Area 0.45 ac 1-yr 24 Hour Intensity 4.61 in/hr Total Impervious Area 0.30 ac Pre -Development 1-yr 24 Hour Flow 0.63 cf/s Impervious % 66% Post -Development 1-yr 24 Hour Flow 1.52 cf/s Design Rainfall Depth 1.0 in Difference in Pre vs. Post Flow 0.9 cf/s Rain Garden Characteristics Top of Dam 619.00 Depth of Flow 1 0.08 Bypass Structure 618.50 Ponding Depth 12 1.00 Surface 617.50 Depth of Top Soil 4.00 0.33 Top of Fill Soil 617.17 Depth of Fill Soil 24 2.00 Top of Washed Sand 615.17 Depth of Washed Sand 4 0.33 Top of #57 Stone 614.83 Depth of #57 Stone 8 0.67 Bottom of #57 Stone 614.17 Size of Underdrains 4 0.33 Invert of Underdrains 614.50 Height of Upturned Elbow 18 1.50 Upturned Elbow into Yard Inlet 616.00 Runoff Calculations Soil Characteristics Surface Area 986.8 sf % Sand 88 % Max Ponding Area 1710 sf % Fines 10 % Min. Volume Required 1052 cf % Organic 3 % Volume Provided 1348 cf Soil Permeability 1.5 in/hr Underdrains P-Index Underdrains 2 Drawdown Time Above Surface 8 hr Underdrain Size 4 in Drawdown Time Below Surface 16 hr Factor of Safety 2 Total Drawdown Time I 24 hr Underdrain Invert 614.50 elev Miscellaneous Information Groundcover Sod SHWT* 600 1 elev Bypass Structure Yard Inlet Distance from SHWT 14.17 ft Forebay? Grassed Swale? X DRAINAGE AREAS & IMPERVIOUS SURFACE Date: 10/28/13 Sheet: 4 Project: Mebane Fire Station Description: Bio-Retention 2 Design By: JSJ Checked By: JSJ Total DA = 0.45 acre Total Impervious Area = 0.30 DA Composition (acre) Comp o Impervious Area /o Pervious Area Impervious Area .1C., Pre 0.45 0.00 0.30 0.0% Post 0.16 0.30 0.73 65.7% Change -0.30 0.30 0.43 65.7% C Values 0.30 0.95 "C" Values Rational Peak Flows Forest 0.06-0.2 Rational 1 Year 2 Year 10 Year 100 Year Grassed 0.1-0.35 Pre-Dev Flow 0.63 0.78 .98 1.17 Paved 0.7-0.95 Post-Dev Flow 1.52 1.89 H.372.83 Gravel 0.7-0.85 Concrete 0.7-0.95 Building 0.8-0.95 Simple Method Runoff Volume Future Asphalt 0.7-0.95 Volume to Surface Area Rv Rainfall Hold Req'd BMP 0.95-1.00 Pre-Dev Flow 0.050 1.0 82 cf Post-Dev Flow 0.641 1.0 1052 cf 1052 cf Pre to Post Flow 0.641 1.0 1052 cf 1052 cf Routing Information Peak Outflow Maximum Max Elevation (cfs) Storage (cf) 2-year Storm 584.59 0.00 1,361.00 10-year Storm 584.70 0.00 1,606.00 See Attachments for complete 100-Year Storm 584.83 1.27 1,944.00 Routing Information. Alley, Williams, Carmen and King ,Inc. Burlington, N.C. Mebane Fire Station Stormwater Calculations DA Area Imp Per la Rv Req Volume Provided Volume Excess Treatment CN C NW Total 0.290 0.191 0.098 0.66 0.645 678 640 94% -38 88 0.73 SW Total 0.452 0.297 0.155 0.66 0.641 1052 1126 107% 74 88 0.76 Front Total 0.398 0.273 0.125 0.69 0.667 963 1421 148% 458 89 0.78 NE Front Drive 0.002 0.002 0.000 1.00 0.950 7 0 0% -7 98 0.95 1.141 2700 3187 118% 487 64 Project: Mebane Fire Station StvrmTech® By: Josh Johnson Owerrlro-fterwoa-Rechaw Units: Imperial Point of Contact Josh Johnson Subsurface Stormwater Management" Date: 10/29/2013 System Requirements Required Storage Volume 600 CF Select Stormtech Chamber System SC-310 96" (2440 mm) MAX. Stone Porosity (Industry Standard = 40%) 40% PAVEMENT 18" (460 mm) MIN. FOR UNPAVED INSTALLATION WHERE RUTTING FROM Stone Foundation Depth 6 Inches VEHICLES MAY OCCUR, INCREAST COVER TO 24"MINIMUM. A Storage Volume Per Chamber 31.00 CF - 6° (150 mm) MIN. Avg Cover over Chambers (18 in min. & 96 in max.) :2:4] Inches ,o - - o 0 16 in (406 mm) Number of Chambers Required 20 Each 6 in (150 mm) Required Bed Size 581 SF I——III—III—III—III-' Tons of Stone Required q 55 Tons III —III III—III-1 I—III—III-1 I I-1 11= I I III-1 I I-1 I I—ITi- Volume of Excavation 82 CY Area of Filter Fabric 181 SY 6" MIN. 12" MIN. TYP. # of End Caps Required 8 Each Length of ISOLATOR ROW 35.6 FT ISOLATOR FABRIC 16 SY Is the limiting dimension for the bed the width or length? width Controlled by Width (Rows) Controlled by Length Width 15 FT Length I 100 FT # of Chambers Long 5 EA # of Chambers Long - EA # of Rows 4 EA # of Rows - EA Actual Length 39.20 FT Actual Length - FT Actual Width 14.82 FT Actual Width - FT Material Estimate EwTo use this sheet: Please enter data into the blue cells. If switching between Imperial c NIL Please call StormTech @ 888-892-2694 for conceptual cost estimates. www.stormtecn.com 12U heaver Koad 15ulte 1 U41 Wetnerstleld I Uonnecticut I U61 U91 888.892.2694 1 tax 86b.328.84U1 Storm Tech SC-310 Undergroung Storage Elevations Ground Surface 621.50 Top of Stone 619.23 Top of Chamber 618.73 Top of Inlet Structure 621.50 Inlet Structure Invert 617.40 Inlet Structure Weir 618.73 Inlet Structure Sump 615.40 Bottom of Isolator Row 617.40 Bottom of Chamber 617.40 Bottom of Stone 616.90 6" Perforated Underdrain Invert 617.20 Top of OC 621.75 Overflow Weir 618.98 Invert of OC Structure 617.10 Inver of Downstream YI 617.00 Cover (ft) 2.77 Inlet Structure Freeboard (ft) 2.77 Outlet Structure Freeboard (ft) 2.77 Chamber Height (ft) 1.33 iL a ii ci U f7. 0 Z 0 m 0 0 M a c+i N hi C) CD THIS PLAN DOES NOT PURPORT TO SHOW ALL EXISTING UTILITIES, LINES, APPURTENANCES, ETC., AND THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES, PIPES, VALVES, ETC. AS SHOWN ARE IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE ENGINEER/ARCHITECT. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES, LINES, PIPES, ETC. BEFORE COMMENCING WORK, AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT RESULT FROM THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES, PIPES AND VALVES. THE CONTRACTOR SHALL NOTIFY THE ENGINEER/ARCHITECT OF ANY CONFLICTS WITH EXISTING AND PROPOSED FACILITIES TO DETERMINE IF AN ITEM WILL NEED TO BE RELOCATED. THE ENGINEER/ARCHITECT HAS MADE NO EXAMINATION TO DETERMINE WHETHER ANY HAZARDOUS OR TOXIC MATERIALS ARE PRESENT OR CONTAINED IN, UNDER, OR ON THE SUBJECT PROPERTY OR ITS WATERS, OR IF ANY HAZARDOUS OR TOXIC MATERIALS HAVE CONTAMINATED THIS OR OTHER PROPERTIES OR ITS WATERS IN ANY WAY WHATSOEVER. NO SUB -SURFACE EXAMINATION OF ANY TYPE HAS BEEN MADE BY THE ENGINEER/ARCHITECT, AND ACCORDINGLY, NO OPINION IS EXPRESSED OR INFERRED ON ALL SUCH MATTERS. FURTHER, NO OPINION IS RENDERED AS TO ANY VIOLATION OF ANY ENVIRONMENTAL LAWS OR REGULATIONS, EITHER FEDERAL, STATE, OR LOCAL RELATED TO THE INFORMATION SHOWN ON THIS PLAN AND THE ENGINEERIARCHITECT IS IN NO WAY LIABLE FOR ANY VIOLATION OF SUCH ENVIRONMENTAL LAWS SHOULD SUCH EXIST. 1-6"X6" TEE 1-6 "X2" TEE 1-6" FIRE LINE RPZ 1-2" COMPOUND DOMESTIC WATER CONNECTION WITH FEBCO RPZ BACKFLOW VALVE ASSEMBLY 5-6" MEGA —LUGS PP*-- `——oHE--_ OHE--__ _'—OHE----- -__ ---OHE---_._ 1-6" 90" BEND PROP. 5' — OHE--_. 2-6" MEGA —LUGS CURB CUT ASH PARTNERS Deed Bk, 948 Pg, 553 Plat Bk. 56 Pg. 136 (Includes Conservation Easement & area in Road Right of Ways) Zoned R--20 and B-2 AGAPE BAPTIST CHURCH Deed Bk. 433 Pg. 844 TMJ 10-23-46o GPIN#9824024349 Zoned R-20 Class 4 SOD _ ------- KI } ' - = 1 _ 1 i 1—FIRE HYDRANT 9 x 19' PARKING 1-6" GATE VALVE SPACE, TYP. 2-6" MEGA —LUGS 6" CONCRETE PAVING ON 6" ABC, TYP. 30 CURB & GUTTER, TYP. SOD 'WON \ r \ r \ b \ \ r r b , 0 \ \ 2-6" 22.5' BENDS 4-6" MEGA --LUGS CONCRETE PAD` J r 7LW/TELEPHONE \ \\ \\ r 1-6" 45' BEND PANELS 2-6°° MEGA —LUGS TELE. PED ___'-.-OHE—_ IP \ \ r OH U3 \ PP \ \ r 1-12"X6" TF_E 612'GATE MEGA�LUGS 3-6LVE " MEGA —LUGS (BY OTHERS) TELE. ' 1 SCREEN WALL VAULT } \ \\ r t SEE 1/A6.1 1 \ mmwmq 1 10' X 70' SIGHT \ 1 r DISTANCE EASEMENT 30" CURB 8c GUTTER, 6" CONCRETE (4, 000 PSI 1 \ 1 r W/FIBERMESH REtNFO�?CING) , 1 ON 6" ABC STONE, TYP. 1 1� INV. 615.58 :� — INV.=616.66 1 , PROVIDE DETECTABLE 1 WARNING DOMES PER NCDOT STANDARDS OIL%WATER } 1 1 SEPARATOR i 11 11 r 4" CONC. WALK t r SEE A5.1 1 1 4 } 1 PROP. 4' WIDE __ _ 1 CONCRETE '77_ ; 1 1 1 r SIDEWALK 1 �0_ ASH PARTNERS Deed Bk. 948 Pg. 553 Plat Bk. 56 Pg. 136 (Includes Conservation Easement & area in Road Right of Ways) Zoned R-20 and B-2 15' X 230' SIGHT DISTANCE EASEMEI I I w imp i to Ilm 1 Ire, w 1 o to w I r T1 � I -z, w ; I_ §aq4 R7l i! Y9 r I mIlk§§®. SIGN I ~ I 1 e ' ESS, . w I I 033170 0 °-F✓YGfNEEF..`�'r.J � s a4xl ' §E°§§§ REVISED 1214113 PER NCDOT COMMENTS w LANDSCAPE PLANTING TO BE COMPLETED I BY C17Y OF MEBANE STAFF. FESCUE TO I r,_ INSTALLED $►CONTRACTOR. SCALE. 1" = 20' 0' 20' 40' 60' 80' 100' THIS PLAN DOES NOT PURPORT TO SHOW ALL EXISTING UTILITIES, LINES, APPURTENANCES, ETC., AND THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES, PIPES, VALVES, ETC. AS SHOWN ARE IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE ENGINEER/ARCHITECT. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES, LINES, PIPES, ETC. BEFORE COMMENCING WORK, AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT RESULT FROM THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES, PIPES AND VALVES. THE CONTRACTOR SHALL NOTIFY THE ENGINEER/ARCHITECT OF ANY CONFLICTS WITH EXISTING AND PROPOSED FACILITIES TO DETERMINE IF AN ITEM WILL NEED TO BE RELOCATED. THE ENGINEER/ARCHITECT HAS MADE NO EXAMINATION TO DETERMINE WHETHER ANY HAZARDOUS OR TOXIC MATERIALS ARE PRESENT OR CONTAINED IN, UNDER, OR ON THE SUBJECT PROPERTY OR 17S WATERS, OR IF ANY HAZARDOUS OR TOXIC MATERIALS HAVE CONTAMINATED THIS OR OTHER PROPERTIES OR ITS WATERS IN ANY WAY WHATSOEVER. NO SUB —SURFACE EXAMINATION OF ANY TYPE HAS BEEN MADE BY THE ENGINEER/ARCHITECT, AND ACCORDINGLY, NO OPINION IS EXPRESSED OR INFERRED ON ALL SUCH MATTERS. FURTHER, NO OPINION IS RENDERED AS TO ANY VIOLATION OF ANY ENVIRONMENTAL LAWS OR REGULATIONS, EITHER FEDERAL, STATE, OR LOCAL RELATED TO THE INFORMATION SHOWN ON THIS PLAN AND THE ENGINEER/ARCHITECT IS IN NO WAY LIABLE FOR ANY VIOLATION OF SUCH ENVIRONMENTAL LAWS SHOULD SUCH EXIST, APE BAPTIST CHURCH t Deed Bk. 433 Pg. 844 t \ \\ \ \\ TM# 10-23-46o GPIN#9824024349 I N \ \ \\ t Zoned R-20 \ t N N \ \ Class 4 t I \ \ o\ PP - IQHE- \ \ 'CONCRETE PAD ' \ ---OHE \ W TELEPHONE \ \ \ PROP. Yl NO. 7 \ —oH\ \ J ' PANELS \ FE� NO. 2 \ THROAT-618.50 OHE TELE. \ INV, 618.50 CD BIO-RETENTION BASIN # 7 NV. OUT—� 16.08 oHe``- - - PED \ \ _0HE---__ \ \ SFC ELEVATION = 617.5 � � � -- oHE- � ` � ` EIP \ t BASIN VOLUME _ 51 C.F. � \ \ \ � - o _ oHE _ EX.'EOP \\ 0 14.5'-15" HDPE I _ ---------- 623 4" ROOF 1 \ 1 0 0.55% _ _�____ - --- _ 6" ROOF DRAIN ---- _ \ DRAIN \ \ \ 62 I TELE. `\ - N \ \ 4 I _ — 2.0 623 VAULT c' \ \ FES NO. 6 i i i` ' _ ' \ INV.-616.00 '� I' �\ ... _<--_ - -� \ \\ \ �'.� i , I . ,'��;�� �.:��:. '..:....1:,.-�: -�. ,... �`- . ��'�-1R" RCP 61T�5 I cp�'� N �� 6" ROOF P ^, C) z _ c} lb �y DRAIN TO _ ' DENOTES 5' WIDE CURB FIRTIA�� JMH # 12 1_ , NCDOT STD. 840.51 I INSPECTION PORT SC 310 ISOLATOR ROW PREFABRICATED END CAP \ 6 ROQF INV.-616.66 — - PROP. JMH NO. 1 _ PROP. JMH NO. 1 CUT WITH 5'x4'x12" DEEP I DRAINS I _ -- -`- \ \ \ 1\ TOP-620.75 TOP-621.50 GLASS 1 RIP -RAP PAD. TO BR#2 - - `�' `INV. IN-616,68 INV. 1N-616.70 FX. INV t7ltT INV. OUT-616.60 I SC 310 UNDERGROUND I STORAGE I I I PROP, GI NO. 3 I I TOP- 619.25 I i INV OUT-617.00 I � I I I 6" PERFORATED I I UNDERDRAIN I I i 18" N-12 HP I I STORM PIPE i I I I OR RCP I I I I 12 HDPE I I i CONNECTION I I I — 4'X4' YARD INLET CONTROL �WIOUTLET �--18 "X 12 N-12 WEIR (SEE DETAIL HP ECCENTRIC SHEET C8) HEADER INV. OUT- 617. 10 \ 15 N-12 HP TREE FILTER BOX STORM PIPE (9 620.20 (SEE OR RCP DETAIL SHEET C8) CLEANOUT WITH PLANTING BY DEBRIS SHIELD CITY OF MEBANE I STD. 4" SCH 40 :... ..., PERFORATED = .. ; .. UNDERDRAIN 1 PROP. Cl NO. 13 TOP-621.25 I INV. OUT-617.90 �, 4 BACKFLOW ON 4" UNDER 6 " MIN. 4" RAISED CURB CON ETE FLUM ELEV-621.20 ELEV. 620.50 CLEANOUT WITH DEBRIS SHIELD I SCALE. 1 " = 20' 0' 20' 40' 60' 80' 100' INV. -617. 74 I (�' \ I o I ILi I 12" x 6" CLEAN I STONE SHOULDER I I I I lm Iz ,,'•®.®®a � I � I'—{ /GN i � µV As TrvE I r` I I 62, 56 I L K a .e Deed Bk, 948 Pg.1 553 I'� I EXOP I II SHEET C3 FOR ADDITIONAL : ` SEAL Bk. 56 Pg./136 1a p I I I I N I SITE DISTANCE GRADING. (Includes Conservatl�n Easement & area in Road R*ght of Ways) Zoned R-20 find B-2 .. y 1 1 I I ,f®f �.. �p�p 179t E769 the REVISED 1214118 PER NCDOT COMMENTS REVISED 11118113 ADDENDUM #1 ILL U a a in Cl) a L0 IP CU fV s N THIS PLAN DOES NOT PURPORT TO SHOW ALL EXISTING UTILITIES, LINES, APPURTENANCES, ETC., AND THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES, PIPES, VALVES, ETC. AS SHOWN ARE IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE ENGINEER/ARCHITECT. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES, LINES, PIPES, ETC. BEFORE COMMENCING WORK, AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT RESULT FROM THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES, PIPES AND VALVES. THE CONTRACTOR SHALL NOTIFY THE ENGINEER/ARCHITECT OF ANY CONFLICTS WITH EXISTING AND PROPOSED FACILITIES TO DETERMINE IF AN ITEM WILL NEED TO BE RELOCATED. THE ENGINEER/ARCHITECT HAS MADE NO EXAMINATION TO DETERMINE WHETHER ANY HAZARDOUS OR TOXIC MATERIALS ARE PRESENT OR CONTAINED iN, UNDER, OR ON THE SUBJECT PROPERTY OR iTS WATERS, OR iF ANY HAZARDOUS OR TOXIC MATERIALS HAVE CONTAMINATED THIS OR OTHER PROPERTIES OR ITS WATERS IN ANY WAY WHATSOEVER. NO SUB -SURFACE EXAMINATION OF ANY TYPE HAS BEEN MADE BY THE ENGINEERIARCHITECT, AND ACCORDINGLY, NO OPINION IS EXPRESSED OR INFERRED ON ALL SUCH MATTERS. FURTHER, NO OPINION IS RENDERED AS To ANY VIOLATION OF ANY ENVIRONMENTAL LAWS OR REGULATIONS, EITHER FEDERAL, STATE, OR LOCAL RELATED TO THE INFORMATION SHOWN ON THIS PLAN AND THE ENGINEERJARCHITECT IS IN NO WAY LIABLE FOR ANY VIOLATION OF SUCH ENVIRONMENTAL LAWS SHOULD SUCH EXIST. AGAPE BAPTIST CHURCH Deed Bk. 433 Pg. 844 GRAVEL & TM#10-23-46a RIP -RAP GPIN#9824024349 FILTER BASIN Zoned R-20 \ Class 4 '� J \ .'-SHE \ \ \ \ -OHE '---0 I � RIP -RAP PAD I I NO. 1 SEDIM i I i I I i � I PERM. RIP -RAP OUTLET STABILIZATION -NEW PORK `D METHOD I CLASS NUMBER ZONE RCP -RAP THICKNESS LENGTH WIDTH I 1 2 B 12°' 8' 4° i 2 2 B 12 8' 4° *LINE OUTLET WITH FiLTER FABRIC I I J I 6'x2'x12" DEEP CLASS I RIP-R4P PAD 1' I R1P-R4P PAD I, i i NO. 2 I ® I I ASH PARTNERS Deed Bk. 948 Pg. 553 I l I � Plat Bk, 56 Pg. 736 ! I p I (includes Conservation Easement �` y & area in Road Right of Ways) I I I n I Zoned R-20 and B-2 h NEW STABILIZATIONTIMEFRAMES Site Area Description Stabilization Tirneframe Expectations 013 Perimeter dikes, swales, ditches and slopes 7 days None High Quality Water (HQW) Zones 7 days None Slopes steeper than 3:1 7 days If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed. (� Slopes 3:1 or flatter 14 days 7 days for slopes greater than 50' in length. All other areas with slopes flatter than 4:1 14 days None, except for perimeters and HQW Zones. Sediment Basin Calculations and Design Chart 1 623� 1 1 Z TELL 623 VAULT 1 IF ti \ \ 'CONCRETE PAD �\ W/TELEPHONE I PANELS I i PED y't \ \ \ \ \ \ \ B O W CD M cl 1 \ \1\ \1 0 \ \\ \ \ � CONCREff FLUME UNDER f SIDEWALK �44;eo_ lei. -615.58 RIP -RAP DONUT INLET PROTECTION UNTIL INSTALLATION OF JMH NO, 1 622� - - -S._ _SF S-SF- SF SF _ � SF-SF-tcaccccauutttuaccc�cac c c I I ti SODDED 1SWALE o i 12" HIGH TEMPORARY GRAVEL & rn (Noco ro I DIVERSION RIP -RAP I i i� I I Im I I BERM '^ FILTER BASIN FILTER jy I I I 6'x2'x12' DEEP PAD CLASS RIP R4P \ \ _ _ 1 '` 1 I�nl a I ,m I In I ' h ASH PARTNERS11GN �, I I I 1 Deed Bk. 948 Pg. 553 I I I Plat Bk. 56 Pg./ (includes Conservation Easement & area in Road Right of Ways) Zoned R-20 End 8-2 I 111 I 11 I l l Drainage Area 10 Year Storm Req Volume Re Surf Area Prov. Volume Prov Surf Area Side Slopes Dam Bottom Weir Type (ac) Rational (cfs) (cf) (sf) (cf) (sf) ft/ft Sediment Basin #1 0.29 1.17 522 378.885 851 542 3:01 619 617 618.5 Skimmer Sediment Basin #2 0.45 1.81 810 587.925 1348 987 3:01 619 617 618.5 Skimmer Temporary Sediment Trap #3 0.4 1.61 720 522.E 770 576 2:01 621 618 620 Skimmer III Ii I I 1 11 15' X 230' Sight Distance Easement i= CA � I i iII4 I I 1111 / OPE I III�II I l 4:1 SLI I I Ii'�I I I Ii a �'P °Illjli I I l I 11 II i I v �I �11 1lIIII "I � i � ��I l 625---- N � I - - - - - -624_ _ _i _--- --623 _622- SILT PROTECTION AT CONSTRUCTION ENTRANCE 50, L 12' W 8" THICK INSTALL SILT FENCE ON SAME DAY AS SITE DISTANCE GRADING. SEED WITHIN 24 HOURS OF GRADING. Erosion Control Construction Sequence 1. Obtain NCDENR Erosion Control Permit, 2. Hold a Pre -Construction Meeting. J. Install Construction Entrance. 4. Install Perimeter Silt Fence. 5. Install Sediment Basins. Minimize compaction in bottom of Sediment Basins. 6. Install Storm Drainage at front of property (JMH #1, FES #2, Gl, #3, JMH #4, FES #5) and stub on joint out of GI #3 toward site. Block stubbed pipe with plywood board or other complete blockage. Contact NCDOT prior to installation. Submit shop drawings of materials at least 15 days prior to installation. 7. Install Inlet Protection around storm drainage. Seed around Storm Drainage. 8. install temporary diversion berm upstream of construction entrance. 9. Rough Grade site including site distance area along Mebane Oaks Road. On some day as site distance area on Mebane Oaks road is graded, install silt fence to prevent offsite erosion. 10. Install water and sewer services. 11. Test water and sewer services. 12. Begin Building Construction. 13. Once exterior Building Construction is completed begin curb and gutter, sidewalk, stone base and concrete paving installation. Sub rode stone and concrete installation shall be done to NCDOT and City of Mebane requirements. g , y q Install Curb inlet #133 and pipe to JMH #12 but block curb inlet opening with plywood and silt waddle to prevent water and/or sediment from entering curb inlet. Place waddles in front of all curb cuts. 14. After concrete work is completed, sodding should begin. Sod Section A (around the building) shall be done first. 15. After Sod Section A is installed and has taken hold, then contact NCDENR Land Quality representative and request permission to remove Sediment Basin's #1 and #2 and silt fence on back half of property. 16. After Land Quality's approval, contact the design engineer prior to beginning conversion of Sediment Basin #1 and #2 into Bio-Retention Basin's #1 and #2. 17. After Approval of Design Engineer convert Sediment Basin #1 and #2 into Bio-Retention Basin #1 and #2. SEE SPECIFIC INSTRUCTIONS FOR CONVERSION, 18. Sod Bio-Retention Basins #1 and #2. 19. Contact Land Quality and request permission to remove Sediment Basin #3 and any remaining erosion control measures. 20. After areas near front of building ore sodded contact design engineer and Jeremy Cadeau with ADS prior to installation of Storm Tech Underground Storage. Jeremy Codeou can be reached at (828) 423---6933 or at Jeremy.cadeou@ads-pipe.com. 21. install Storm Tech Underground Detention and Isolator Row. SEE SPECIFIC INSTRUCTIONS FOR INSTALLATION AND FOLLOW MANUFACTURERS INSTRUCTIONS. 22. Install and connection JMH #12 into Storm Tech Device. 23. Install Sod Section C including over the Storm Tech Device and entire front yard. 24. Contact Design Engineer for installation of tree filter box. 25. Remove Plywood obstruction from Curb Inlet. 26. Block Curb Cuts into Tree Filter Box with plywood obstruction. 27. Install Tree Filter Box. SEE SPECIFIC INSTRUCTIONS FOR INSTALLATION. 28. Contact Design Engineer, Architect, and City of Mebane for site walk through. 29. Owner, design engineer, maintenance workers, and architect shall meet and discuss long term inspection and maintenance of all stormwater BMP's on site. SCALE. 1 " = 30' 0' 30' 60' 90' 120' 14®��®®a�oeoaavaa000 SECI il 033170� ®� (,1 FNG I NEti� 150' .4,tryy�a s. oof®aa�a�a�m°as REVISED 12112113 PER NCDENR COMMENTS REVISED 1214113 PER NCDOT COMMENTS 4" TYP. SHAPE DOGHOUSE 12"Wx18"H DOGHOUSE BALL VALVE � O S s k£ . fi 12" 36" LID 4" D WEIGHT. • 2,900 LEIS. D 30, ELEVATION PRECAST CONCRETE 4x 3' METER SOLDER BUSHING --�- 2" EIP OUTLET TEE (FOR 2" METER) F O ALL BRASS OF R 85-5-5-5 RED BRASS D UNS C83600 AWWA CBOO-05 ASTM 862-02 2 1/8" OD COPPER TUBE DUAL CARTRIDGE CHECK VALVE COUPLING BALL VALVE 2 118" OD COPPER TUBE —+s- 1 3/8" OD COPPER TUBE FLOW D'. BAFFLE Itm 2 rem WrejmoMEO■ G ii ! . ■ 4 4■ � " � 2'-6- 1/2' RAD. ( h 9' Qz M1�. CURING COMPOUND iz' a° a 4 3,0D0 PSI CONCRETE CURB EXPANSION JOINT EVERY 90' CONTRACTION JOINT EVERY IT 30" CONCRETE SPILL CURB & CUTTER SL VIL I\LI LIV IIVIY BAFFLE (TOP OF BAFFLE NOTE ALL BAFFLE AND WIER PLATES ABOVE OUTLET) ARE TO BE GALVANIZED. OIL WATER SEPARATOR - 4' X 6I.®. DUAL ANGLE CHECK VALVE 18.00" 2" EIP r OUTLET TEE 1/2" RAD. h CURING Q' COMPOUND 2" 6. 7. 4 a a ° 4 a 3,GDO PSI CONCRETE CURB EXPANSION JOINT EVERY 90' CONTRACTION JOINT EVERY 10' 2" NEPTUNE TRUFLOW COMPOUND RADIO METER (ONLY IN GALLONS) FORD #VBHH77 18BHC-11-77 22-63 CUSTOM 2" METER/STRAINER SETTER. C.I.V.B. COVER C.I. VALVE BOX 2" DUCTILE IRON GATE VALVE 2" OPERATING NUT (200 P.S.I. 1 WATER WORKING PRESSURE) F6103 BY CLOW FLOW 2" BRASS NIPPLE-7 AMERICAN DARLING OR CLOW IF VALVE BOX IS NOT IN PAVED AREA, PROVIDE A 2'-0" X 2'-0" CONCRETE COLLAR (TYP. OF ALL VALVES) 6" L CAST IRON J VALVE BOX \ 6" GATE VALVE 15" MIN, 2„ 20" MAX. CAP RUST-OLEUM OIL BASED BRIGHT WHITE BARRELL RUST-OLEUM OIL BASED TRACTOR RED #57 WASHED STONE BY CONTRACTOR UNDISTURBED EARTH 3,000 PSI CONCRETE BLOCKING 6" DUCTILE y/x IRON PIPEVA�� 6" DUCTILE SEE WATER MAIN VALVE `•VA//AA VA/� IRON PIPE DETAIL FOR BLOCKING SIZE GONG. "x PAD CLASS "B" CONC. D BY VARIES VARIES CONTRACTOR **MEGA -LUG FROM TEE THROUGH VALVE TO HYDRANT FIRE HYDRANT INSTALLATION PROVIDED PROVIDED BY BY CITY PROPERTY OWNER TO CITY SPECS, 2" COMPOUND 4'x3' METER VAULT. o: 6" 12" MIN. FROM TOP VARIES OF METER TO TOP OF METER BOXIR EQ. 2' STIMER BY NEPTUNE Pita NO. 53120-000 DOUBLE i CHECK BRASS PIPE - RAY! I �2" TYPE W' `J 2" DOUBLE STRAP BRONZE SOFT COPPER SADDLE (FORD STYLE 2028) 2" COPPER 4" WASHED 2" COPPER FOR 2" NIPPLE COMPRESSION STONE COMPRESSION FITTING ONLY (MCF) FITTING ONLY NOTE: (MCF) 1) COMPRESSION FITTINGS ONLY, NO FLARED FITTINGS. 2) RPZ'S TO BE TESTED ANNUALLY. PROVIDE COPY OF TEST TO CITY. 6" MIN. CLASS B CONCRETE V UNDISTURBED < EARTH PLAN - BENDS SECTION BUTTRESS DIMENSIONS PIPE 22 1 2' BENDS 45' BENDS 90' BENDS SIZE L H L H L H 6" 1 _0 1'-0° 1'-0" 1'-0" i'-4" i'-2" B" i'-0- 1'-0° 1'-4" 1'-2" i'-10" 1'-6" 12" 1'-4" 1'-4° 2'-6" f— ,— 2" STRAINER 12" INSTALL THREADED — UNIONS ABOVE — CONCRETE PAD FOR REMOVAL BRASS ELBOW —2, SEPARATION BRASS PIPE (30" MIN.) -MBX-5 CAST IRON METER BOX W/ HOLE IN LID FOR RADIO READ ANTENNA ,. /� / ■ 1. NOTES: 1. DIMENSION "A" SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERRING WITH THE MECHANICAL JOINT BOLTS 2. THE SHAPE OF THE BACK OF THE BUTTRESS MAY VARY PROVIDED THE CONCRETE IS AGAINST FIRM, UNDISTURDED EARTH. 3. BUTTRESS DIMENSIONS ARE BASED UPON A SOIL RESISTANCE OF TWO TONS PER SO. FT. AND A WATER PRESSURE OF 150 P.S.I. THRUST BLOCKS - BENDS 2" CUT-OFF VALVES — HOTBOX MODEL HB2S ��A �-�---BRASS PIPE �`— POWER SUPPLY BY PROPERTY OWNER FLOW COMPRESSION FITTING AFTER ELBOW 4" WASHED STONE 501 X 24"W X 4"T CONCRETE PAD _ FEBCO RPZ BACKFLOW VALVE ASSEMBLY (825YBV) OR EQUIVALENT CLASS B CONCRETE UNDISTURBED EARTH "\ m PLAN - TEE EARTH TRENCH WIDTH 112"�X CLASS B 4s• CONCRETE N SECTION BUTTRESS DIMENSIONS 6" V-6" V-4" 12" 2'-3" 2'-0" w z vw w z APPROVED DEVICES A. RPZ 1. WILKINS 475 DARR OR 375 ADA W/ REMOTE READOUT (GAL) 2. FEBCO SERIES 826YD DETECTOR WITH REMOTE READER (GAL.) B. DOC 1. FEBCO 876V WITH REMOTE READER (GAL.) 2. WILKINS MODEL 350 ADA WITH REMOTE READOUT (GAL) *NOTE: RPZ "HEAT SOURCE TO BE PROVIDED BY OWNER" REQUIRED ONFIRE LINES WITH FIRE DEPARTMENT REDUCED PRESSURE DECTECTOR BACKFLOW ' OR CONNECTIONS. DOUBLE DETECTOR CHECK VALVE AS REQUIRED BY CITY OF MEBANE ,— GATE VALVE BRICK PIER z 30"+ 12" a" DETECTOR METER - NEPTUNE _III III. METER ONLY %" x a/4" T-10 - WITH E CODER-R900 PIT _I GALLON REGISTER. MEGALUG ALL MJ FITTINGS. D.I.P. REQUIRED FROM MINIMUM OF 2' DJ P. ON METER TO BACKFLOW DITCH MUST REMAIN OPEN UNTIL BACKFLOW OUTLET SIDE OF BACKFLOW IS INSPECTED BY CITY OF MEBANE. NOTES 1. THE BACKFLOW DEVICE SHALL BE WITHIN 10' OF AND ON THE PROPERTY SIDE OF THE METER. ENCLOSURE SHALL NOT OBSTRUCT SITE DISTANCE AT ROAD CROSSINGS. 2. ALL BACKFLOW DEVICES SHALL BE INSTALLED ABOVE GROUND IN A HORIZONTAL POSITION UNLESS OTHERWISE PREAPPROVED BY THE CITY OF MEBANE. 3. SHUT OFF VALVES SHALL BE RESILIENT SEAT WITH FLANGED END AND O.S.&Y HAND WHEELS. 4. ALL INTERIOR AND EXTERIOR IRON SURFACES SHALL HAVE EXPDXY COATINGS TO CONFORM TO ANSI/AWWA C550 OR MANUFACTURED OF STAINLESS STEEL. 5. APPROVED ABOVE GROUND ENCLOSURES: "HOT BOX", HYDROCOWL, SMI MODEL # b68—EHPZD, B80—EHPZD, B110—EHPZD) OR BFP (#640-1PD, 800-1PD, 950—APD OR 1150—APD. ENCLOSURE MUST HAVE A DRAIN 6. TANDEM BACKFLOWS REQUIRED IF SERVING MULTIPLE USERS OR SERVICE CANNOT BE INTERRUPTED 7. DETECTOR METER AND BACKFLOW ASSEMBLY SHALL BE INSTALLED IN ENCLOSURE. 8. PIPE & FITTINGS BELOW GRADE TO BE M.J. WITH RETAINER GLANDS, 150 PSI MIN. WORKING PRESSURE. 9. INSTALL BACKFLOW DEVICE NEAR MAIN WATERLINE CONNECTION AT STREET RIGHT OF WAY. 10. ALL BACKFLOW DEVICES SHALL BE TESTED, INSPECTED, AND MAINTAINED BY THE OWNER. PROVIDE ANNUAL REPORTS TO CITY. ABOVE GRADE BACKFLOW PREVENTER, 311 AND GREATER 43 S.S. HINGES WTH -TAMPERPROOF BOLTS �12 1 / 7` 1 /2 0 0 --I- 33 XXXXXXy 18 (TYP) 0an a0 " a PLAN VIEW Ss. WATERTIGHT SLAMLOCK STAPLE FOR PADLOCK FLUSH CAST ALUMINUM DROP HANDLE �SLAMLOCIC PLUG %AMLOCK KEY T ZZZ_ UW 22 S.S. AUTOMATIC HL OPEN ARM W/RED \4 GRIP SECTION VIEW SIDE 9/16 DOA. HOLE �3/,} ® 18 O.C. iA FLOOR PLATE MAIL: ALUM.---- 14e i I/O EXTRUDED 34 TH ACTUAL OPENING RETROFIT TTION YAN 35 FRAME OPENING NTEGRAL SEAT 36 CONCRETE OPENING �1/4 (TYP) SECTION VIEW FRONT FRAME DETAIL ALUMINUM ACCESS HATCH _p � e S EAi 033117 . v '•. oy FVc NEE , B. D. BRANCH DIAMETER hVA AO `,.` S NOTES: 1. DIMENSION "C" SHOULD BE LARGE ENOUGH TO MAKE ANGLE "A" EQUAL TO OR GREATER THAN 45'. 2. DIMENSION "Do SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERRING WITH EHT MECHANICAL JOINTS. 3. BUTTRESS DIMENSIONS ARE BASED UPON A SOIL RESISTANCE OF TWO TONS PER SQ. FT. AND A WATER PRESSURE OF 150 P.S.I. THRUST BLOCKS - TEES NOTES: 1-MATERIAL: ALUMINUM 2- LOADING: 300 LBS. PER SO. FT. 3- 316 STAINLESS STEEL BOLTS 4- APPROXIMATE WEIGHT: 59 LBS. 4' CONC. WAL TOP a 18'-0" 18'-0" 18'-0" STANDARD M.H. ----- E STD. PRECAST -� s.s' umm - STRIP MAX. MAX. MAX. -___ EXPAN.JOINT CONC. TOP �.._ RING AND COVER a USE EXPANSION JOINT IF EQ, EQ. EQ. SEE STD. ST-7 - EXPANSION CURB & GUTTER iS NOT POURED. SPACES SPACES SPACES Y OUTLET PIPE C R JOINT „EXPANSION 6" ® i/2 " EXP. _ >a, r JOINT E G G E G G E G G E G =-- -__ •GRASSED )- �� DETECTABLE -__1 ( ' I I ( I I I I % x 2"CL. --- 3"CL.�I-- "'„<<, Sp PN MTL. A A • WARNING SURFACE SEE DETAIL & NOTE I & 2 „ , NO.4 STEEL BARS 30' CURB & GU 6 FOR W ' = 6'-0" OR LESS E=EXPANSION JOINT I Re 5" CONCRETE EXPAN. ( A' STD. C & G B L 4" R., TIP. JOINT JJJ EXPANSION GO.Ns• G=GROVE JOINT _[ „to JOINT 2'L X 4 w STREET [==_====1 DETECTABLE NOTES: EXCEPT WHERE SHOWN iN THE PLAN, OUTLET PIPENG SURFACE 3� PLAN WITH PLAN WITHOUT SEE DETAILR&1 NOTE 1 & 2 ALL NEW CONCRETE WALKS SHALL HAVE Y ' '�2�- TOP TOP +` EXPANSION s JOINTS SPACED AS SHOWN IN THESE DETAILS. PLAN SLAB PLAN 30" CURB & GUTTE CUR A5' UTILITY 5'-10" 402 THROAT CLR. 5" JOINT TRANS F EXPANSION STRIP Jo1Nr AN EXPANSION JOINT SHALL BE USED TO SEPARATE 4' CONC. WALK 10 7_4.2�1" 402 �+/- 065 IN. TOL. C 5" PRECAST 3-8 403 pSPH. / CONCRETE COVER STD. RING e THE W CONCRETE WALK FROM OTHER D COVER K NEW OR EXISTING CONCRETE CONSTRUCTION. I- F NOTES: & 3 R. ?GRASSED �i� N N 5" PRECAST 6, C JOINT PATTERN CONCRETE COVER L5 5S 5" o D ..r; • cr; .2., I .. :.. ALL MORTAR JOINTS OPENING• ' ARE TO BE i /2 " � 1 /B " M' 4 -e 402 4 + BRICK MASONRY CAN 6-0" 403 z_ 2'-3' EXPANSION 2ND OPENING IF REQUIRED7 6" BE STANDARD CLAY -I SUMPS PLAN JOINT 114,» 6" A B H H B ORLCCONC.MBO BRICKRICK, B g" 1 Fr 2'L X 4'W FOR DEPTHS OVER ' y DETECTABLE --- - 4 -0 3" STEPS MORTAR OR 0 WARNfNG SURFACE ON i'-3"ECENTERS. SEE NOTE 7 & 2 I I �� / „ � � �•'..".. •,. d r ,•:": CONC.AR : 2500 PSI CONC. 1 8 -I- R. � _ to' 421 MAX ----- :.i, r . •. 6. 6" j ,SECTION YY Sa'IION A -A C _ _ 5. SECTION-XX TION e B GROVE JOINT STANDARD BRICK MASONRY CURB INLET PREFORMED C.O.M. STD.#402 SECTION EXPANSION C.O.M. STD.#403 JOINT MATERIAL 3/8 NOTES. 30" ROLLED CURB ALL CURB INLETS OVER 3'-6" IN DEPTH TO BE PROVIDED WITH STEPS 1'-0' ON CENTER. STEPS SHALL BE IN DIN'S OF BOX & PIPE COVER ACCORDANCE WITH STANDARD SPECIFCATION DRAWING PIPE SPAN WIDTH HEIGHT -DIMENSION SS-1 AND SS-2. B I. DETECTABLE WARNING DOMES SHALL COVER o o - _ , D A B H(MIN) F G 2'-0" LENGTH AND FULL WIDTH OF THE RAMP / LO CLASS "A" CONCRETE 3000 P51 TO BE USED. STD. 411 FLOOR AS SHOWN ON THE DETAILS. 1 8 R• o tY 3'-e" 2'-3' 2'-4- 4'-10' 3'-7" # 2. THE RAMP MAY BE YELLOW IN COLOR OR ANY - - PRECAST CONCRETE CATCH BASIN. JUMBO BRICK OR CONCRETE 3" R RING & COVER COLOR WITH A 70.$ CONTRAST RATIO. BRICK MAY BE USED IN LIEU OF CLAY BRICK. 15" 3-6 COLOR 2'-3" 2' ]" 4' 70" 3'-]' FULL WIDTH OF RAMP 0.45" R 3",TYP. TYP. 4' MIN. �•) EXPANSION JOINT FOR B'-0' IN HEIGHT OR LESS USE 8-INCH WALL. R OVER 18" 4'-0' 2'-0• 2' ii' 5' 4' 4'-0' - 8'-0" IN HEIGHT USE 12-INCH WALL R AININ FROM TOP - FLAT OF WALL AND 8-INCH WALL FOR THE RAMA NING 6'-0'. 24" 4'-0' 2' 9' 3' S" 5' 4" 4'-0" 2", TYP. - n 0.20' R IF REINFORCED CONCRETE PIPE IS SET IN BASE OF SLAB 30' 4'-0' 3' 6' zF 11" 5' 4" 4' 10' 0 0 o O O D �-) JOINT DETAILS NOTE: 2",TYP. OF BOX USE STANDARD SPECIFICATION DRAWING ST-10. os1z.as` (TYP.) ALL CONCRETE TO BE 36' 4'-0' 3'-6" 4' 6" a-:. 4'-10' r A tP SECTION A -A (1YR MANHOLE RING ANO COVER IN CONCRETE LOP SHALL CONFORM OOOOO2--0' 3000 PSI MIN. TO STANDARD SPECIFICATION DRAWING NO. ST-7.42' 4'-0" 3'-8' 4' 11" 4'-10" 4'LENGTH REINFORCING STEEL SHALL CONFORM TO ASTH A-615 GRADE 60 qe' 4'-6' 4'-0' S'-5" 5'-4" VV-- O O O O O O SECTION �,.) o 0 0 0 0 0 1 J L TA !� STD BRA A CATCH BASIN WITH 3".TYP. -. DETECTABLE WARNING PLAN NOT TO SCALE SINGLE & MULTIPLE PIPES 12" THRU 4811 6" TYP. DOMES DETAIL CITY OF MEBANE --1" H,ry ") 11"t Ap WHEELCHAIR RAMP SECTION B-8 d-1 i Y L"J tdl� B PLAN STD. 402 INLET TOP REQUIRES 4, #4 BARS IN STREET FACE. `r STD. 403 INLET TOP REQUIRES 4, cI� 4'-0" rr ow pm�, P.S RING Lx-NE STD, NO. e40.e4 or„ I.-. 36� -{ 5 BARS IN STREET FACE. 21/4 I -'a c`d GENERAL NDT£B: F SHED D-�?` 3/8" STEEL I T T 3/8" RED HEAD ANCHOR # _ aa3 ,-. z as 6 24" 6"' WITH FLUSH MOUNT j zW x� o MORTAR DSNrs YY" = g' THICK. I ELEVATION rg� PLATE ALL OTHER REINFORCING STEEL MR Oil y : �� I _. IUL�aED � m06III CONCAVE raDL ALL rxrasED uolNrs. ��oc? IS #4 BARS. -.z-izY NJ &_ 00,= ETIM =A USE CLASS "B" CONCRETE THROUGHOUT. a pp�yZ 0oMC'J "'M - iv .i_ C Gtl -N 5� STEP STD. - 5„ =.ryAATn �_-1 _-7 - _ y"''.U�p� ym USE FORMS TO CONSTRUCT THE BASE SLAB- w ', 1 NO. B4O.66 6,. m ai o �( _ _ ^'� 9 �� -, _ 1�- _ ¢ T- C5 x a3 Q m N o ar. ,..r GIOw \ iv =- N?N`P 2" 4 N~0 ��OM'FI SOLIID CONCRETTELBLOCKSEMAYTBEDUSEOONCRLIEUBOFOCLAY BRICK. i �i=-(y,0� 6" n �a _ �� 1v2 N N 0 2M o � STANDARD PRECAST CONCRETE CURB INLET TOP - _ _ ,.., - -tp IF REINFORCED CONCRETE PIPE: IS SET IN BASE. STAB OF BOX, 4y -1 a> - - - - > C.O.M. STD. .. .�A. ADD TO BASE AS SHOWN IN STD. NC. 840.00. �- - --T- 1 B, #412 Np 0 f� I w0 fn0 WHERE THE MANHOLE IS EXPOSED TO ROAD TRAFFIC, CONSTRUCT wp ---^ -- -------F ..L�. ' 0 2 ' THE TOP OF THE MANHOLE FLUSH WITH THE GROUND, AT OTHER X 3_B _ ._-_ X a .�_ 1b' LOCATIONS CONSTRUCT A MINIMUM OF 9" ABOVE THE GROUND. N �1-�� �1o�v���r Fcum a�r,�rL PROVIDE MANHOLES OVER 3'6° IN DEPTH WITH STEPS 72" ON °q1 IPLM tjS CENTERS IN ACCORDANCE WITH STD. N0. 840.66. GRATE: SECTION Y-Y / FOR � DMA. BOLT Lu A '„ M n 1" 1rr FRAME SECTION Y-Y ¢ m SEE NOTE o o N DI 2 8�-� 2 G" A A '� - w a mC11�N ' `o' SECTION ON C 6 ...." 1 -91 ,' rr rr +N r :". -::: - - SF"6" _ 4 Q 1 z 1' 11" 1 �Y o�faA n=. e3 0 b o o RING - 70 LBS. GRATE SECTION X-X x C s PART SECTION Y-Y_ _ a a 1 ,-0" 1 -0" COVER - 118 LBS. o GRATE SECTION X-X !X X Z o - •air I N NIK VAN 6'r ACCESSIBLE 6" ACCESSIBLE ggy z _ �.�. c'7• '_L.- _� F --T GO ® m g MINI1PUM DIMENSIONS AND QUANTITIES F R MANHOLE i N NVAN COMPLYINGSIBLE SIGN WITH ADA 3r_107 ire I � '-__� .J : O PIPE Cu- YOS. TOTAL BRICK Co. YDS. BRICK OEDUCIIaNS I _ I j RESERYEU REQUIREMENTS (AT UAN RESERYEQ PLAN ,Y'LL- -T O� r' Y� N w = 55" BASE r6.5 S FE6.323T OyPE 031 Oy7D I Z PARKING ACCESSIBLE SPACES ONLY). PARKING V` Q 'fi DIM. CONCRETE VISCIDLY WORST FOP, p i 11 !4 J 4, (1 N D BASE V B L - -M. R.C. % ' � ( ui , W D.SaQ o. 3 0.323 a 20 o zs 1 -6" ® 19 1/2' 1/2" .0471 26" ® 1 /2" - ®- 1 2" Ln MI1 FRAME SECTION X- �. t6 D.560 0.530 D.323 0 044 0.005. HANDICAP SIGN / r I 7/8" R. 24" 60 0.530 0.323 0.078 0.113 COMPLYING WITH ADA FRAME SECTION X-X LL 3 r 0. Soo ___- 0__530 0.3230.122 0.170 REQUIREMENTS. MAXIMUM 1" 1" fp NOTE: 0.530 0.323 176 9" PENALTY TN250 II II N 9 16 r �'� MEET' 1 OF 'I SEE STD. DWD. 840.25 SHEET 1 OF 1 4HEET i OF 1 Y>oR- SHEET t OF 1 1 250 _ / 846.24 FOR FRAME ANCHORAGE. 840.24 840.51 SECTION X-X 840.51 oQ 'jl..,.._ ,•.a^ OExERA_ xaTEe• - o m SOLID COVER SHOWN PERFORATE[). PERFORATED AVAILABLE 1 1/8" 1 1/8" USE GI_ASS '8" CONCRETE TNROUS'NNUT. Hm �'Ix ON 18" � -H Y IF SPECIFIED. .. w •jWSOORCR CEBRIG' L OIL' RE SEaN ED I LIEU OF C AYIBR CA a^ saL.Io 6 C'M �.•, STATE LIRE OF SYSTEM ON COVER ¢ 2 7/8 r 2 7/$" L j `I. 3 4„ M CONCRETE BLOC" k4T BE t13tD IN LIEU OF CLAY BRICKS, d yt; 2 w z� U �fnna /// (I.E.: SEWER, STORM DRAIN ELECTRICAL] 1'-11 3 4' 3 "n�� PROVIDE ALL ME FNLEi80VEA S'-S"[k ORPTIN Y[iN 8TEP81^c" r-rQi'3- r-r-r.-,T9� .. ,� - T H _(� A ON CENI EH ME SUPER WHICH COMPLY MI. BID SHARING 840.6a. p n d Z Z T,1 Z GT 3t -i x x USE ,A BAB DOWE,..s AT 12" CENTERS. O ., " 'M A IZ TOP OF COVER xQ RT ME FORMS FOR THE CONSTRUCTION OF THE NEVIN SUE, w��Qx .,h o wQ�I1_x SECTION A -A SECTION B-B t!) O IF REINFORCED CONCRETE PIPE I3 SET IN BOTTOM SLAB OF BOX, ADO TO SLAB 'i = 3 - "� F•^C3 G3 3 112" WIDE STEEL H��-n As SHOWN ON ei0. W. a40.W. Hx~aw 2x.D�� A A '$ G k-z•�•+ RANGED CHANNEL SIGN : S?Fy CMfTT000TWITH PIPE CKNONSMATCPUv,. �CIC0 -i 0oM.,,, ED��0 POST(PAINTED) �j STANDARD INLET RING &COVER Ci ➢� V-8" -- ME STANDARD ERA46.8 ALAI ORATES 540.22 (RtOWN), 640,£n(SNOW1,01 R40.20, ME p.= "'l''�A (J�TAQ 7 -� ",-3" DDD IUlal, AND a40.33. yA YYY YYY 2 M-+ �« FA I C.O.M. STD.#411 a --_ ._-- SEE STAWMO ORAYONO 940.26 FDA ATTACHMENT OF FRAMES ISO ORATES NOT SHOWN, fi'" "� I- - L... _ „-,. J d fM GENERAL NOTES: CONCRETE APRON ChAIFER ALL EXPORTS cO1NERS 1 Ow O TA4 z _ - _ - _ - _ ._. _ - ..._ . , © REGARDLESS OF AGE, ALL DN'WINS NOT TO SCALE. Ta" R. ACCESSIBLE SPACES SHALL BE MAX. DEPTH OF THIS STRUDTUBE FROM TOP OF BOTTOM SLASH TO POP ELEVATION IDENTIFIED BY ABOVE GROUND to ,z FEET. BOTTOM OF COVER -^ r'2" SIGNS ONLY. ' - IV Y ® R GROUNDS PA NTED SHALL SYMBOLSUSE Tv '"IF MEBANE w PLANNEW L'H SEALANT FRAME AND BRATEEI cCL SIT ,"rEa_' " t� PLAN OF COVER ACCESSIBLE SPACES ARE m>� .yw� ' m -IC REQUIRED TO BE STRIPED OFF FIRE /Ir 7■j C`- - cONCPETE APRON ,� TAti._ C) PLAN OF O > SET POST IN ONLY; BLUE COLORING IS NOT � DITCH GRADE �--�� TOP ELEVATION BF.E DETAIL 2" O �"' vT r� T- w �' 8"CONCRETE NECESSARY NOR REQUIRED. DO --- - - `' „ ^ EXPANSION 2 /12 r2" C) N 'I 2 .- A "' 3 s B e" _ AL „ LLd LU i X r STRIPING IS WHITE ON DARK MEBANE, NORTH CAROLINA ' iYi 9 B % YAaDNRr J rH M 2 i>�4 FINS E PAVEMENT,; BLACK ON LIGHT Y = B 4" L 4 M B. in ¢ FINISH GRAD PAVEMENT. MELViLLE TOWNSHIP ALAMANCE COUNTY NORTH CAROL S I�JI _tlriLET PIPE Q _ p Y 11°--- �y° a(�' ' ' :u a � , .. :.,. . - '' ' DE L IS a. n!°'J 1' 10YB" �� a i\���i��iv `; i �i�� 0%<�` ,�i��j��j�� ��� 7 , i ?y�\, L I Si�.�� - alley williarrrs carmen &king is &3 ,. L A" F h_ > 1" i \TYPE a1 „ q -``f"'-%2" Ta- 2 0 \i i`�\i. i,����:\` i; I ENGINEERS, v v O SEE NOTE IMAX. PIPE THIS SIDE TN• (APRON SUPPORT xOrw) d = C7 z eeTx4R v- DITGN DRAOE N Lu C7 z 1.i_ F \I " 334 - 1 43 " z i/ ; /j 740 ha el hSIoad ARCHITECTS 8s SURVEYOR r-M Tn A FFF���--- mm� xs®� P P• burlington n.c. 27215 336 226- r' ,-'_''-' •"""�--- � a, 9AB J � i°: r- �' t \ }^--1'.tDSg„ � � �N �CA 5` r 1 a \ t \ ALTERNATE C7 "'-~ ' MINI NW DSiEXeSONB AND 0UW STSE3 FOB BRICK DR tE6 IMP INLET z I" z Q , DF ' Io Firm s Engineering License No. F-0203 i w x �_ SECTION B_B r` pry PIPe SPAS WIDTH IrE20xT R AL a a. xd. aF eaSIX DEOUcnaxs M •3 OxL [90 MASONRY [M 90x TOTAL FOfl ONE PIPE i N ' i tJ -1-e-+ 2'-D I\ : 7'f 80TT0Y CU. YD. ! r^YEOMAN D. II T'i"..-._.-- \ / J I :7, 1 a'-`' DATE: O A e H N PEn roTAL H IN BOX c.s R.C. -�-� t-1 t ~Y/ J MFRAME W$QOHt6 - L85. / ; SEAL e✓L eJ',1--% JOB NO. �Z�¢ BLAB FT. Hi. R" TL ?`-9!{" ! I 10122113 12" s'-9" 2'-9" 1'-8" 0.309 0. 3,8 0.540 0.657 0.020 0.032 {t COVER - ]20 .l 033170 2` DWG NAME: 72T44CON-E( 15" 3'-8" 2'.0" 1'-„" 0.909 0.34a 0,"A D.943 O.WS OD36 „ „ SECTION A -A I r TtlTAL - 300 VAN ACCESSIBLE GROUND SIGNS '•. F o: DRAWN BY.' ,B" 3'-B" r-O" z'-2" 0<309 O.3,B 0.721 i.Oaa 0.03a 0.a49 60YAEL A r •.• NCI NEE• •' h CC7NSTRUCTION 24" 3'-8" 2'-0" ?'-9" 0.308 0.34E O.R23 1.232 O.tl.. 0.086 \ / NOT in SCALE +°s/y •••-'••• •0��.�; WDF DETAILS SHEET N0. EET 1 O F 90" 7.6` 2'-0" 3'2" 0.90fl 0.34R 1.Osa ,.,os 0.o9z 0.i2T i *, UA S. ,o` 38^ 3'-9° 2 -0" 3' 9" 0.309 0.348 1.289 1.405 0.132 0.118 SHEET i OF 1 BET , OF T - i SHEET 1 OF 1 +, TYPE x2 CHECKED BY. 840"28 840.28 64O"54 840.54 _. 8'-0" MAX. FENCE POST STEEL IV21" GA. WIRE TIED TO POST EDIATE 'ES, TYR FILTER FABRIC (32" MIN. WIDTH) VIIOG EXISTING GRADE ELEVATION OTES: WIRE: FABRIC: POSTS., SPACING: MAINTENANCE FILL SLOPE 1L-11 �d WIRE & FABRIC TO BE TRENCHED LJ 6" MINIMUM INTO GROUND & BACKFILLED. SECTION 32" MIN. WIDTH HOGWIRE, 10 GA. LINE WIRE PROPEX (BY AMOCO) METAL - 6' LONG, TRIANGLE STEP PLACEMENT OF POSTS TO BE 8' APART (MAX.) INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. a. MACHINE COMPACTION OF ALL FILL IS REQUIRED. DIVERSIONS SUFFICIENT TO DIRECT ALL SEDIMENT- LADEN STORMWATER INTO A SEDIMENT CONTROL DEVICE MUST BE INSTALLED PRIOR TO CLEARING AND GRUBBING OF THE AREA (OR IN CONJUNCTION WITH THIS OPERATION IF SEDIMENT CONTROLS AND DIVERSIONS ARE INSTALLED IS EACH CRITICAL POINT IS REACHED). b. DIVERSIONS SHOULD BE LOCATED TO MINIMIZE DAMAGES BY CONSTRUCTION OPERATIONS. c. DIVERSIONS SHOULD BE SEEDED AND MULCHED IF THEY ARE TO REMAIN IN PLACED OVER 30 DAYS. d. CHECK DEVICE AFTER EACH RAIN, BUT ONCE A WEEK REGARDLESS. REPAIR AS NECESSARY. F12" MIN Fva� SLOPE 2:1 MAX ¢ a s N - R FILL GROUND ............................. OR CUT SLOPES 4/ \1, sL COMPACTED FILL BE&M 18" MIN ��FlLIO-W tTt E� )Sl a —i a Litt L, - -r Ih � D1LFti NOTES.' POSITIVE GRADE MUST BE PROVIDED TO ASSURE DRAINAGE IF SLOPE EXCEEDS 2Z. SEED AND MULCH DIVERSION. TRY NOT TO EXCEED 5Z. MAX. DRAINAGE AREA = 5 ACRES WITHOUT SUPPORTING CALCS, DIVERSIONS AT THE TOP OF SLOPES MUST EMPTY INTO AN APPROVED SLOPE DRAIN. BERM/DITCH IS MOST COMMONLY USED. TEMPORARY DIVERSION BERMIDITCH METAL POSTS I GALVANIZED HARDWARE EXTENDS TO TOP OF BOX fI 57 WASHED STONE STANDARD OATCH BASIN/YARD INLET PROTECTION NOTE RELOCATE WOODEN STAKE BEHIND SIDEWALK AFTER SIDEWALK IS PLACED WOODEN �- STAKE & MASONRY LINE PU LIB C ROAD PHYSICAL PROPERTIES AGGREGATE SIZE — USE 3" AGGREGATE MIXED W/ NO. 57's DIMENSIONS OF GRAVEL PAD — THICKNESS: 8 INCHES MINIMUM WIDTH; 12—FT MINIMUM OR FULL WIDTH AT ALL POINTS OF THE VEHICULAR ENTRANCE AND EXIT 8" MIN. AREA WHICHEVER IS GREATER. LENGTH: 50—FT MINIMUM 3" COARSE AGGREGATE CONSTRUCTION SPECIFICATIONS 1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT. 2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS, AND SMOOTH IT. J. PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. MAINTENANCE MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2—INCH STONE. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE CHANNEL INSTALLATION NOTE: HORIZONTAL STAPLE SPACING SHOULD BE ALTERED CRITICAL POINTS IF NECESSARY TO ALLOW STAPLES TO SECURE THE A. OVERLAPS AND SEAMS CRITICAL POINTS ALONG THE CHANNEL SURFACE. B. PROJECTED WATER LINE REFER TO GENERAL STAPLE PATTERN GUIDE FOR C. CHANNEL BOTTOM/SIDE CORRECT STAPLE RECOMMENDATIONS FOR CHANNELS. SLOPE VERTICES 8 SAND BAG PROVIDE WATTLE AROUND GRATE AND ANCHOR TO CRATE BY TIEING MASONRY 2 \ ..... _ - i f n 1 CLI- « 111 1•1e1 1-1 1 « 1 1 1 1 I Ilr� II 1�1_1 a a r r n=� 1_ I' 11 7 4 *3" (7.5 cm) I. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING APPLICATION OF LIME, FERTILIZER, AND SEED. j 2. BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE BLANKET IN A 6" DEEP X 6" WIDE TRENCH, BACKFILL AND COMPACT THE TRENCH AFTER STAPLING 4, (1 J. ROLL CENTER BLANKET IN DIRECTION OF WATER FLOW ON BOTTOM OF CHANNEL. A. PLACE BLANKETS END OVER END (SHINGLE STYLE) WITH A 6" OVERLAP. USE A DOUBLE ROW OF' STAGGERED STAPLES 4" APART TO SECURE BLANKETS. 5. FULL LENGTH EDGE OF BLANKETS AT TOP OF SIDE SLOPES MUST BE ANCHORED IN 6" DEEP X 6" WIDE TRENCH BACKRU AND COMPACT THE TRENCH AFTER STAPLING. 6. BLANKETS ON SIDE SLOPES MUST BE OVERLAPPED 4" OVER THE CENTER BLANKET AND STAPLED (2" FOR C350 MATTI 7. IN HIGH FLOW CHANNEL APPLICATIONS, A STAPLE CHECK SLOT IS RECOMMENDED AT 30 TO 40 FOOT INTERVALS. USE A ROW OF STAPLES 4" APART OVER ENTIRE WIDTH OF THE CHANNEL. PLACE A SECOND ROW 4" BELOW THE FIRST ROW IN A STAGGERED PATTERN, 8. THE TERMINAL END OF THE BLANKETS MUST BE ANCHORED IN A 6" DEEP X 6" WIDE TRENCH, RACKFILL AND COMPACT THE TRENCH AFTER STAPLING. 14649 HIGHWAY 41 NORTH, E✓ANSVILLE, INDIANA 47711 USA 1-800-772-2040 CANADA 1-600-446-2040 CHANNEL LINER DETAIL 2' (0.6m) W W 2 0 0 0 0 0 0 0 3.4 STAPLES PER SQ. 1 (4.1 STAPLES PER SQ. A STAPLE PATTERN CATCH WOODEN STAKE, 2'X2'X2' LONG, MIN. CLASS 1 RIP RAP SEE o SECTION THRU BASIN BELOW I' — 8 1NpERT RIP RAP HEADWALL OW -a J5 WASHED STONE 1' THICK X 3' HIGH MIN. RASFo6yFNTSTO GE ZONE_,- i / E OW PERSPECTIVE VIEW AREA TO BE PIPE INVERT DISTURBED I' FL00D STORAGE RIP RAP HEADWALL (CUT; FILL, ETC.) ZONE 2 NOTE, 3' GRAVEL & RIP RAP FILTER BERM BASIN DETAIL 1 IS DESIGNED TO PROTECT EXISTING PIPE INVERTS NATURAL GROUND THAT DRAIN 10 ACRES OR LESS. NOTE: DIMENSIONS ARE 1.5.5 —r- MINIMUM ACCEPTABLE UNLESS OTHERWISE NOTED. CLASS 1 RIP RAP SEDIMENT STORAGE f%5 WASHED STONE MAX. SEDIMENT DEPTH (CLEAN OUT POINT) SECTION THRU BASIN, PIT P AND CULVERT PIPE *3" (7.5cm) -Seam Stitch'"' 3.3' (1.0m) M Tap of ! Be at L, the Top Stone Filter of 1" Diameter Washed Stone Steel Fence Poste. Were Fence T' Filter Fabric Hardware Cloth l On Ground Bury Wire Fence and Hardware Cloth J 1 It SECo _ _o���w�b�ob�odO ob�ob� obb obO ob0obv ob$obQo� b�) 00 op0 26 o 0 B$0 obb g8 ®gg ob 60 Sb0 ob ob0 ob0 ob r r �-eury mre fence. Filter Fabric and Hardware Steel Fence Post Set Max. 2' ApaH Cloth in Trench SILT FENCE CUTLET VIPORAR)' AND PERM ANLN"I SI 1 LING SPI 111(Al IONS UPON CONIPLEITON AND A(( LPI'ANC1, OP IMPROVIAILHIS 01 1HNI;1) IN 111[] PII:ASINLi 1'Rt)GRANI. IIIt, ENTIRE V2LA DISHIRBLD 13l' PROJICI CONSIRIiC IfON SI LAI_I. 131i PROVIDED AA1"Ell A PIJzNIANFNT VEGEI-A"LIVE COVER, 1'JIL DISIURI31.1) AREAS SHALL BE I IGLU IILLL.0 HY II-ARRO4k IN(.i. 1klll Rl'. SOII- CONIDI ]IONS ARI l Nl'.AVORAL3l_E POR SU(( L'NSFt L L: , I ABLINHNII N I OP COVER. AVAIL:AH1.F "IOPSOIL SIiAI.I 13C SPREAD. yAPI'I Y SOIL sAMXiLN DA16N IN VVD MULCH AT l lil. R AIh:S SHOWN BFI ON'. SLID S}IALI_ BI: LIGHTLY C'OVF Rt;l? A?VD SOIL. SI I:AL1. IiF; I'J ItVII U. SIR lVl- N4ULC'IJ SIiAIL BE APPI_11 1) 1 O "Flit SLFDIA) ARIA :AND ANCHORED W'I TLI A LACK. IIVIIC_It\Rt SI I.UIN ',PLCII]CAI IONS UATF:S RAIN 0l3. AC'RL) JANU;VtY I 1.11,11:S"FONI; 2000 FLR]ILIZIiR(10-10-10) 750 RYE (GRAIN) 110 VIULCII-SIRAAV& LACK d000 MAY I- Al (il SI JS L.I3- E',1 ONIi 2000 LER I IIAZER (10-10-10) 75D GLRMAN MILLF.J to \tUl C'FI SIR;AAAZ JACK 4000 AUOIST I5-JANUAR'I I 1.1N1ESIONI, 2000 I.I'RIIL]/LR(10-10-10) 1000 I.YI'(GRAIN I- PO VJUL(II- SIRAAV& LACK 4000 S(IIL')I ICAO 21R PROVIDING I'LliMANIi.NT V1iGF I A NVF COVER Im I I RA'I'1: (LB.%AC'RL) NOVI M13LR I—PF13RUAR) I5 AVINI FR I ILL I LSCl11; 100 RYL. ((iRAN) d0 1,1L3Rt'ARY 16 - APRIL 30 SI'RNG "TALI. I'ISC OF 90 KOBE LL:SPLDLZA (SF:L: NO "IF: 1 ) 30 Love N9aintcliancc Slopes "FALL FESCUE RO SI RICL:A 11.SI'EDI:7A 30 KO W LFNI'FDLZA 10 SLAY I—AUGIS1 30-1)LAtAJFR I ALL ILSAAJF SO GEIt\TAN NJILLI'l !U SI PI LNIBI R 1 Of, 10111 R 31- P-ALL, I I I, IIS( 111-: 120 GFNI]R \L NOTLS' 1. 1 OIL I'LRVI-ANI NT VI GI I A] IVE COVER. SOIL iNILNDAIINT APP KC A I [ON R \LI , APPLY LIMI AND I 1 R I ILI/FR \( ('ORDING TO SOIL l I'll! S. OR "'PLY 4,000 LB AC GROUND AGRI( tit, I t R AI. I IAII SI ONI AND 1000 1 B A( 10-10-10 1 I R I R I/_L R APPLY -1000-LB A( GRAIN S I R A\A Nlt. LCH. .ANC I IOR All IL('i I A% 1111 1 A( K. NE I I IN(i OR CRIMPING N 10 SOIL . 2. I JAIPOR.AR) OR PERM ANLN I GROUND LOVLR MI ALL HE PROVIDED ON ALL I VPONE D SL OPLS 1A I II IN 21 C AI END \R D At S 101 1 OAVING COMI'LL. I ION OFAN) I'1IASL OI GRADING N R%IANI NT SI I:DING FOR ILL IT NIURBLD .AILI AS NIIALL, BF PROVIDI:1) NkllllIN 15 \AORKNG DAYS Olt 90 CAI,I VD4R DAYS IOI J 01,A FIN6 (0AIPLFJION OF CONNIRtL IION OR DEVFLOPNII NF. w'HIC'IIFVLR IN NI IOR"I ER. TEMPORARY AND PERMANENT SEEDING SPE�IFIkoptl S METAL POSTS" s - GALVANIZED HARDWARE EXTENDS TO TOP OF BOX q .:: nnonw mwm STANDARD CATCH BASIN/YARD INLET PROTECTION NOTES. 1. DRIVE 5' STEEL POST AT LEAST 24" INTO SOLID GROUND. 2. USE STAPLES 1' APART HORIZONTALLY AND VERTICALLY TO ATTACH THE FABRIC TO THE HOG WIRE. 3. SPACE THE BAFFLES ACCORDING TO THE APPROVED PLAN. 4. THE FLOOR OF THE BASIN IN THE OUTLET ZONE AND BERMS SHOULD BE SEEDED IMMEDEATELLY AFTER THE BASIN IS CONSTRUCTED CUT fi" SLITS FABRIC WITH THE BOTTOM OTHER SOUAI WIRE VERTICA HORIZONTALLI BAFFLE INSTALLATION - STEP 2 TOP OF BAFFLE SHOULD BE 6" BELOW THE TOP OF THE BERM MAINTENANCE INSPECT TEMPORARY SEDIMENT TRAPS AFTER EACH PERIOD OF SIGNIFICANT RAINFALL. REMOVE SEDIMENT AND RESTORE TRAP TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN A DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. CHECK THE STRUCTURE FOR DAMAGE FROM EROSION OR PIPING. PERIODICALLY CHECK THE DEPTH OF THE SPILLWAY TO ENSURE IT IS A MINIMUM OF 0.5 FT. BELOW THE LOW POINT OF THE EMBANKMENT. IMMEDIATELY FILL ANY SETREMENT OF THE EMBANKMENT TO SLIGHTLY ABOVE DESIGN GRADE ANY RIP RAP DISPLACED FROM THE SPILLWAY MUST BE REPLACED IMMEDIATELY. STABILIZE THE EMBANKMENT AND ALL DISTURBED AREAS ABOVE THE SEDIMENT POOL AND DOWNSTREAM FROM THE TRAP IMMEDIATELY AFTER CONSTRUCTION WITH SEEDING. J. W. FAIRCLOTH & SON INC. POST OFFICE BOX 757 HILLSBOROUGH, NORTH CAROLINA 27278 FLOAT TELEPHONE: (919) 732-1244 FAX: (919) 732-1266 THREADED OUTLET END CONNECTED TO PIPE THROUGH SEDIMENT TRAP DAM FLEX HOSE p INLET SCREEN WITH ORIFICE INSIDE VENT SCH. 40 PIPE SUPPLIED BY CONTRACTOR Now SCALE: NOT TO SCALE PVC DEBRIS SHIELD MODIFIED 30" CURB AND GUTTER (SEE DETAILS) 6" MIN (TYP.) 2' MIN a CHANNEL & GRATE CURB CUT (SEE PLAN SHEETS) T MIN (TYP.) TREE FILTER 6" MIN. (TYP.) *TREE FILTER MIX IS TO BE 957 MIXED SAND WITH 5% ORGANIC MATERIAL. MIX SHALL HAVE A MINIMUM PERMEABILITY OF 13'%HR. MATERIAL IS TO BE UNCOMPACTED & SPREAD FROM THE TOP. MATERIAL TESTING SHALL BE COMPLETED & CERTIFIED PRIOR TO INSTALLATION. TREE/SHRUBS TO BE PROVIDED BY CITY OF MEBANE TOP OF PLANTING SOIL 4'" WIDE NOTCH 12" MAX (TYP.) 4" MIN SECTION VIEW NTS Bio-Retention Basin # 1 DrainageCharacteristics Peak Flow Characteristics 5-rainaQ2 Area 0 29 ac 1- r 24 Hour Intensity 4.61 in/tir Total Im rvicus Area 0 19 ac Pre -Development 1- r 24 Hour Flow 0.40 cfls m rvious % 66% Post -Development 1-yr 24 Hour Flow 0,97 offs Design Rainfall Depth LO in IDifference in Pre vs. Post Flow 0.6 off- Rain Garden Characteristics Top of Dam 619.00 Depth of Flow 1 0.08 Bypass Structure 618,50 Pondin2 Depth 12 1A0 Surface 617.50 Depth of Top Soil 400 0.33 Top of Fill Soil 617,17 Depth of Fill Soil 24 2.00 Top of Washed Sand 615.17 Depth of Washed Sand 4 0-33 Top of 457 Stone 614.83 Depth of #57 Stone 8 0.67 Bottom of #57 Stone 614,17 Size of Underdrains 4 0.33 Invert of Underdrains 614,50 M Hei of Upturned Elbow 15 1-25 Upturned Elbow Into Yard Inlet 61575 Runoff Calculations Soil Characteristics Surface Area 542 s€ % Sand 88 % Max Pondi Area_Lj 1159 sf % Fines ':D % Min. Volume Required 1 677 of °io Or anic 3 % Volume Provided 851 of Soil Permeability 1.5 inlhr Underdrains P-Index Underdrains 2 Drawdown Time Above Surface 8 hr Underdrain Size 4 in lDrawdown Time Below Surface 16 hr Factor of Safety 2 ITotal Drawdown Time 24 hr Underdrain Invert 614 50 elev Miscellaneous Information Groundcaver Sod I ISI-iWT* 600 elev B pass Structure Yard Inlet Distance from SHWT 14.17 ft Foreba . Grassed Swale? X OVERFLOW STRUCTURE. STD. 4' YARD INLET - SEE DETAILS FOR STANDARD BRICK YARD INLET (SHEET 10) TOP OF DAM f 5 ROPE TO SKIMMER ATTACHED j\� j/X j 24" OUTPUT MALE PIPE THREAD PIPE CONNECTION FROM SKIMMER HOSE TO RISER DRAIN FLANGE. Outlet Pipe L SKIMMER BARREL SIZE - 2 112" n � FAIRCLOTH DISCHARGE TO OUTLET PAD P1 AIV SKIMMER OR DRAINAGE STRUCTURE a CONCRETE SIDEWALK 8" GRAVEL 3'-5' GRASS FOREBAY - WEIR ELEV @ ELEV-V. SIDE -SLOPES TO BE 2:1 WITH CLASS B RIP -RAP 9" PONDING DEPTH FILL SOIL MEDIA 88% MIX SAND, 9% FINES, 3% ORGANIC DEPTH SOD OVER 6" TOP SOIL. CAPPED CLEAN OUT PIPE UPTURNED ELBOW INTO YARD INLET. INVERT INTO YARD INLET @ ELEV.-'L' OVERFLOW STRUCTURE. STD. 4' YARD INLET. TO BE WATERPROOFED. RIM AT ELEV-'B' INVERT AT ELEV -'E' BIO-RETENTION DAM ELEV.-'A' OVERFLOW YARD INLET RIM ELEV.-'B' TOP OF SOIL AND SOD ELEV. -'C' TOP OF FILL SOIL ELEV -'D' 15' HOPE @ 0.509 INVERT OF 18 RCP ELEV.- E TOP OF WASHED STONE ELEV-'F' j 4000 PSI - FILTER FABRIC & TOP OF #57 STONE ELEV. -'G' a4 CONCRETE 4" WAS ED SAND 8 #57 STON 0 Q , BOTTOM OF #57 STONE ELEV -'H' 4" PVC 24" i' \ y y �x y SCH. 40 IN SITU SOIL RISER, TYP. WATER TABLE IMPERMEABLE LINER As 4" PVC PERFORATED DIRECTED FILTER FABRIC 2' DISTANCE FILTER FABRIC TO WATER TABLE UNDERDRAIN INVERT ELEV -'J' 8" NO. 57 CLEAN STONE (DO NOT COMPACT) 4" PVC SCH. 40 UNDERDRAIN, TYP. Bio-Retention Basin # 2 Drainage Characteristics Peak Flow Characteristics Drainage Area 0.45 ac 1- r 24 Hour Intensity4.61 Inlhr Total Impervious Area 0.30 ac Pre -Development 1- r 24 Hour Flow 0.63 cfts Impervious % 61 Post -Development 1-yr 24I-lour Flow 1.52 cf/s Design Rainfall Depth 1.0 in Difference in Are vs Post Flow 0.9 cfls Rain Garden Characteristics Top of Darn 619,00 Depth of Flow 9 008 ss Structure Surface 618,50 617,50 Ponding Depth De th of Too Soil 12 4.00 1.00 0,33 Top of Fill Soil 617,17 Depth of Fill Soil 24 Z00 To 7 of Wasried Sand 615,17 Depth of Washed Sand 4 0,33 Top of457Stone 614,83 Depth of #57 Stone 8 0,67 Bottom of #57 Stone 614.17 Size of Underdrains 4 0,33 Invert of Underdrains 614.50 Hei ht of Upturned Elbow 8 1,50 Upturned Elbow into Yard Inlet 1 616,00 Runoff Calculations Soil Characteristics Surface Area 986 8 sf % Sand 88 % Max Ponding Area 1710 sf % Fines 10 % Min. 'Volume Required 1052 cf % Organic 3 % Volume Provided 1749 cf Soil Permeability 1.5 in/hr Underdrains Underdrains P-Index Underdrains 21 Drawdown Time Above Surface 8 hr Underdrain Size 4 in Drawdown Time Below Surface 16 hr Factor of Safety 2 otal Drawdown Time 24 hr UnderdrainInvert 614.50 elev Miscellaneous Information Groundcaver Sod I ISH\ArT* 600 elev Bypass Structure Yard Inlet Distance from SHWT 14.17 ft Foreba . Grassed Swale? X #6 REBAR FOR SECURING ROPE /ROPE ATTACHED / TO SKIMMER OVERFLOW OPENING FAIRCLOTH SKIMMER EXCAVATE SHALLOW PIT UNDER SKIMMER VARIES BOTTOM OF BASIN N.T.S. 1. Tree Filter Box shall not be installed until after the Stormtech Device has been installed and the area has been sodded. 2. Contact Design Engineer prior to installation. 3. Submit shop drawings for Tree Filter Box. The following shop drawings will be needed: a. Wall Design. b. Impermeable Liner. c. PVC Debris Shield. d. Underdrains, perforated and unperforated. e. Tree Filter Media with 95% Washed Sand and 5%Organics and a minimum permeability of 13"/hour. 4. Block the curb cuts with plywood. it is contractor's responsibility to keep sediment out of the work area until installation is complete. 5. Begin Excavation. 6. Build the walls. Compact only underneath the curb walls. 7. Rip the bottom 12" with the teeth of an excavator or a steel road. DO NOT COMPACT basin area. 8. DO NOT PLACE EQUIPMENT IN BOTTOM OF BASIN AT ANY POINT DURING INSTALLATION. 9. Excavate to the full depth of the Bio-Retention Basin. Engineer or Engineer's Representative needs to see the site at this time. 10. Install 8" #57 clean stone and 4" perforated underdrain. Do not compact. Do not drive truck or equipment into bottom of basin. Engineer or Engineer's Representative needs to see the site at this time. 11. Connect the underdrains to 1MH #11, 12. Install Tree Filter Media Mix. Mix will need to be certified and submitted to Engineer prior to installation. Mix shall meet requirements on drawing AND have a minimum permeability of 13" / hour. Engineer or Engineer's Representative needs to see the site at this time. 13. Install limited top soil on top of the media. Top Soil shall meet specifications and shall be free of clay. Engineer or Engineer's Representative needs to see the site at this time. 14. Remove plywood obstructions from curb cut. 15. City of Mebane will plant the box. 16. Contractor is responsible for preventing sediment from entering the box until final payment has been made on the project. 1. THE BOTTOM OF THE INFILTRATION POND SHALL BE RIPPED A MINIMUM OF 12" DEEP WITH THE TEETH OF THE BUCKET OR A STEEL ROD. 2. DO NOT PLACE EQUIPMENT IN BOTTOM OF BIO-RETENTION BASIN TO PREVENT COMPACTION. 3. REACH FROM OUTSIDE INTO BASIN. r.' i �" a SEAL ° 033170 _ ENGINEER.: �GTOe syUA S. J�� •` BASIN NO. 1 2 ELEV. A' 619.00 619.00 ELEV. 'B' 618.50 618.50 ELEV. 'C' 617.50 617.50 ELEV. 'D' 617.17 617.17 ELEV. 'E' 616.00 616.00 ELEV. 'F' 615.17 615.17 ELEV. 'G' 614.83 614.83 ELEV. 'H' 614.17 614.17 ELEV. 'J' 614.50 614.50 ELEV. 'K' 618.00 618.00 ELEV 2' 616.00 616.00 1. Bio-Retention Basins shall not be converted until after upstream areas are sodded, paved, or otherwise stabilized. 2. Contact Design Engineer prior to beginning any conversion of sediment basin to bio-retention basin. 3. DO NOT PLACE EQUIPMENT IN BOTTOM OF BASIN AT ANY POINT DURING CONVERSION. 4. Remove sediment basin baffles. Remove all posts and materials. 5. Remove sediment from bottom of basin. It is contractor's responsibility to keep sediment out of basin until conversion is completed. 6. Excavate to the full depth of the Bio-Retention Basin. Engineer or Engineer's Representative needs to see the site at this time. 7. Rip the bottom 12" of the basin with the teeth of an excavator or a steel rod. Minimize compaction efforts whenever possible. 8. Attempts to minimize red clay from surface should be done at this point. 9. install 8" 457 clean stone and e perforated underdrain. Do not compact. Do not drive truck or equipment into bottom of basin. Engineer or Engineer's Representative needs to see the site at this time. 10. Install Up Turned Elbow from Underdrains into Yard Inlet. Up Turned Elbow will force infiltration and increase filtration. 11. Install filter fabric over stone. Engineer or Engineer's Representative needs to see the site at this time. 12. Install 4" Washed Stone on top of filter fabric. Engineer or Engineer's Representative needs to see the site at this time. 13. Install Bio-Retention Media Mix. Mix will need to be certified and submitted to Engineer prior to installation. Mix shall meet requirements on drawing AND have a permeability of 2"-6"/ hour. Engineer or Engineer's Representative needs to see the site at this time. 14.. Install Top Soil and Sod on top of Bio Media. Top Soil shall meet specifications and shall be free of clay. Engineer or Engineer's Representative needs to see the site at this time. 15. Sod Entire Sod Section B Area. This includes both bio-retention basins as well as surrounding areas. 16. It is still the contractor's responsibility to minimize sediment to the Bio-Retention Basin is completed until Final Payment has been made. MATERIAL LOCATION DESCRIPTION AASHTO M43 COMPACTION/DENSITY REQUIREMENT DESIGNATION ' OFILL MATERIAL FOR LAYER'D' STARTS FROM THE ANY SOIUROCK MATERIALS, NATIVE SOILS, PREPARE PER ENGINEER'S PLANS. PAVED INSTALLATIONS TOP OF THE'C' LAYER TO THE BOTTOM OF FLEXIBLE PAVEMENT OR UNPAVED FINISH GRADE OR PER ENGINEER'S PLANS. CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. N/`4 MAY HAVE STRINGENT MATERIAL AND PREPARATION REQUIREMENTS. ABOVE. NOTE THAT PAVEMENT SUB -BASE MAY BE PART OF THIS LAYER. FILL MATERIAL FOR LAYER'C' STARTS FROM ® GRANULAR WELL -GRADED SOIUAGGREGATE 3, 357, 4, 467, 5, 56, 57, BEGIN COMPACTION AFTER 12" [305 mm] OF MATERIAL OVER THE TOP OF THE EMBEDMENT STONE TO 18" MIXTURES, < 35% FINES. MOST PAVEMENT SUB- THE CHAMBERS IS REACHED. COMPACT ADDITIONAL [457 mm] ABOVE THE TOP OF THE CHAMBER. BASE MATERIALS CAN BE USED IN LIEU OF s, 9 89 8 78 7 68 67, , , , , , , LAYERS IN 6" [152 mm] LIFTS TO A MIN. 95% STANDARD NOTE THAT PAVEMENT SUB -BASE MAY BE A THIS LAYER. 10 PROCTOR DENSITY. ROLLER GROSS VEHICLE WEIGHT NOT PART OF THIS LAYER. TO EXCEED 12,000 Ibs (53 kN]. DYNAMIC FORCE NOT TO EXCEED 20,000 Ibs [89 kN]. ©EMBEDMENT STONE SURROUNDING THE CLEAN, CRUSHED, ANGULAR STONE, NO COMPACTION REQUIRED. CHAMBERS FROM THE FOUNDATION STONE NOMINAL SIZE DISTRIBUTION 3, 357, 4, 467, 5, TO THE 'C' LAYER ABOVE. BETWEEN 314 - 2 INCH [19 - 51 mm] 56,57 (p� FOUNDATION STONE BELOW CHAMBERS FROM CLEAN, CRUSHED, ANGULAR STONE, PLATE COMPACT OR ROLL TO ACHIEVE A 95°! STANDARD v THE SUBGRADE UP TO THE FOOT (BOTTOM) OF NOMINAL SIZE DISTRIBUTION 3, 35, 4, 467, 5, PROCTOR DENSITY '. THE CHAMBER. BETWEEN 3/4 - 2 INCH [19 - 51 mm] 56,57 PLEASE NOTE: 1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO.4 (AASHTO M43) STONE". 2. AS AN ALTERNATE TO PROCTOR TESTING AND FIELD DENSITY MEASUREMENTS ON OPEN GRADED STONE, STORMTECH COMPACTION REQUIREMENTS ARE MET FOR w LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 9" [229 mm] (MAX) LIFTS USING TWO FULL COVERAGES WITH AN APPROPRIATE COMPACTOR. I 18" [457 mm] 96" [243$ mm] MIN. MAX. 6" [152 mm] MIN. THE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO ' CONSTRUCTION, IT IS THE ULTIMATE RESPONSIBILITY OF THE DESION ENGINEER TO ENSURE THAT THE PRODUCTS) DEPICTED AND ALL ASSOCIATED LSM W MATE E AI MEET APPLICABLE LAWS. REGULATIONS AND Rw" PR OJECT REQUIREMENTS. & NT . +cm oRNNAaE sysT6lss wc. ' REOU CHAMBERS SHALL MEET ASTM F2922 "STANDARD SPECIFICATION FOR POLYETHYLENE (PE) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" NOMINAL 3/4"- 2" (19 mm - 51 mm) CLEAN, CRUSHED, ANGULAR STONE (AASHTO M43 #3 THROUGH #57 STONE SIZES ALLOWED) DEPTH TO BE -- DETERMINED BY -- DESIGN ENGINEER -1 I 1=� 6" [152 mm] MIN. 4 STORMTECH ACCEPTABLE FILL a StormTdc SCALE: NTS Subsurfocest --- tor Ma° nagam• e�rt' DATE: 3/30/10 DRAWN BY: KLJ 70 INWOOD ROAD, SUITE 3 1 ROCKY HILL, CT 06067 PHONE: 886892-2004 1 FAk88&84 32801 WWW.STORMTECH.CDM CHECKED: CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". GRANULAR WELL GRADED SOIL/AGGREGATE MIXTURES, C35% FINES. COMPACT IN 6" LIFTS TO 95% STANDARD PROCTOR DENSITY. SEE THE TABLE OF ACCEPTABLE FILL MATERIALS PAVEMENT .n� f rf �f rf rllfr�i:. r' i N Y_ N r•� /�: Is THE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIORTO CONSTRUCTION. IT IS THE ULTIMATE RESPONSIBILITY OF THE DESIGN %tDj. 19 ' SC-310 TYPICAL CROSS SECTION ------- SCALE: NTS AwnNr�aowNAce sysTs"s, INO' ENGINEER TO ENSURE THAT THE PRODUCTS) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS. o.e,w,.amm,•au�4. Subsurface Stormwot.rM gement" ---- DATE: 08-22-12 701NWOOD ROAD, SUITE 3 I ROCKYHILLCT06061 40 PHONE: 888-892-2894 1 FAX 8661,8401 DRAWN BY: JLM WWW.6TORMTECH.COM CHECKED: • NYLOPLAST 12" [300 mm] INLINE DRAIN BODY W/ 12" [300 mm] SOLID HINGED COVER AND FRAME (SEE NYLOPLAST DWG# 7003-110-044 FOR PAVED APPLICATIONS / SEE DWG# 7003-110-045 FOR UNPAVED APPLICATIONS) d d 96"[2438 mm] MAX 18" [457 MMI MIN SC-310 CHAMBER NOMINAL 3/4 - 2 INCH [19 mm - 51 mm] CLEAN CRUSHED ANGULAR STONE 4" [100 mm] SCHED 40 SCREW -IN CAP CONCRETE COLLAR r PAVEMENT 4" [100 mm] SCHED 40 PVC 4" [100 mm] SCHED 40 PVC COUPLING 4" 4" [100 mm] SCHED 40 PVC [102 mm] CORE 4.5" [114 mm] O HOLE IN CHAMBER (4.5" HOLE SAW REQ'D) CONNECTION DETAIL NTS AwANCEo aPNNAGE SY9TEM5,uc THE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT 16 THE ULTIMATE RESPONSIBILITY OF THE DESION ENGINEER TO ENSURE THAT THE PRODUCT{S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAM, REGULATIONS, AND PROJECT REQUIREMENTS. - SkO■ Subsurface Sto"nwater Manag anl,9 701NWDOD ROAD, SUITES (ROCKY HILL, CT 06087 PHONE: 896892-2894 I FAX: 8883268401 WWW.STORMTECH.CCM SC-310 INSPECTION PORT DETAIL 4j`[eALE: NTS DATE: 6/15/11 DRAWN BY: KLJ CHECKED: INSPECTION PORT (SEE STORMTECH SC-310 INSPECTION PORT DETAIL) ST WOVEN GEOTEXTILE (OR EQUAL) BETWEEN FOUNDATION STONE AND CHAMBERS SC-740: 5'-6" [1.7 m] WIDE STRIP SC-310: 4'-0" [1,2 m] WIDE STRIP COVER ENTIRE ROW WITH ADS 601 NON -WOVEN GEOTEXTILE (OR EQUAL) SC-740: 8' [2.4 m] WIDE STRIP SC-310: 5' [1.5 m] WIDE STRIP STORMTECH END CAP f_- M AwAVGED aPNNSGE sys-Eels, lr.C. a THE DESIGN ENGINEER SHALL REVIEW THIS D WINPRIORI.-- R4 G CONSTRUCTION. IT 18 THE ULTIMATE RE6PON8I I BUOFTHERAND DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S)DEPITTCTEDAND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS, 7 ® "'WrMAh s.an>...n wrio„a«nvice S.Wur1a StonnWatel Management® 70 INWOOD ROAD, SUITE 3 I ROCKY HILL, CT 080B7 PHONES88892-2894 1 FAX: 8653288401 WWW.STORNITECH.COM ISOLATORTM ROW PROFILE ^-------- SCALE: NTS DATE: 6/15/11 DRAWN BY: KU CHECKED: r NUMBER AND SIZE OF UNDERDRAINS PER ENGINEER DESIGN DUAL WALL PERFORATED HOPE UNDERDRAIN PIPE STONE BEDDING UNDER DRAINAGE PIPE STORMTECH END CAP "TORMTECH CHAMBER FOUNDATION STONE BENEATH CHAMBER ADS 601 NON -WOVEN GEOTEXTILE (OR EQUAL) FOUNDATION STONE - DUAL WALL PERFORATED BENEATH CHAMBER HDPE UNDERDRAIN PIPE A ADS 601 NON -WOVEN A GEOTEXTILE (OR EQUAL) STONE BEDDING UNDER I SECTION 13-13DRAINAGE PIPE TO OUTLET CONTROL STRUCTURE a AwAvcEo ouu"ars sysrs ,ram THE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATE RESPONSIBILITY OF THE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULAI'IONS, AND PROJECT REQUIREMENTS. 4 " Stor o SubsurfaceStOnnwoterManogement" 70 INWOOD ROAD, SUITE 3 ROCKY HILL CT D6067 PHONE: 888892-2894 FA%: M3258401 WWW.STORMTECH.COM SC-310 UNDERDRAIN DETAIL ------- SCALE: NTS DATE: 6/15/11 DRAWN BY: KLJ CHECKED: TABLE 1, RECOMMENDED MINIMUM TRENCH WIDTHS MIN. COVER TO RIGID PAVEMENT, H ��! ��i MIN. COVER TO FLEXIBLE PAVEMENT, H i, FINAL BACKFILL PIPE DIAM. MIN TRENCH WIDTH 12" (300mm) 30" (750mm) 15" (375mm) 34" (860mm) 18" (450mm) 39" (990mm) 24" (600mm) 48" (1200mm) 30" (750mm) 56" (1420mm) 36" (900mm) 64" (1620mm) 42" (1050mm) 72" (1830mm) 48" (1200mm) 80" (2030mm) 60" (1500mm) 96" (2440mm) SPRINGLIKE -� INITIAL Jrz BACKFILL TABLE 2, MINIMUM RECOMMENDED COVER BASED ON e HAUNCH VEHICLE LOADING CONDITIONS BEDDING 4" FOR 12"-24" PIPE 6" FOR 30"-60'° PIPE IN TRENCH WIDTH _ I SUITABLE NOTES: (SEE TABLE) t FOUNDATION 1 ALL PIPE SYSTEM STORMTECHER SPECIFICATIO 1. CHAMBERS SHALL BE STORMTECH SC-310, OR APPROVED EQUAL. 2. CHAMBERS SHALL BE MANUFACTURED FROM VIRGIN POLYPROPYLENE OR POLYETHYLENE RESINS, 3. CHAMBER ROWS SHALL PROVIDE CONTINUOUS, UNOBSTRUCTED INTERNAL SPACE WITH NO INTERNAL SUPPORT PANELS THAT WOULD IMPEDE FLOW OR LIMIT ACCESS FOR INSPECTION. 4. THE STRUCTURAL DESIGN OF THE CHAMBERS, THE STRUCTURAL BACKFILL, AND THE INSTALLATION REQUIREMENTS SHALL ENSURE THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET FOR: 1) LONG -DURATION DEAD LOADS AND 2) SHORT -DURATION LIVE LOADS, BASED ON THE AASHTO DESIGN TRUCK WITH CONSIDERATION FOR IMPACT AND MULTIPLE VEHICLE PRESENCES. 5. CHAMBERS SHALL MEET ASTM F2922 (POLYETHYLENE) OR ASTM F2418 (POLYPROPYLENE), "STANDARD SPECIFICATION FOR THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 6. CHAMBERS SHALL BE DESIGNED AND ALLOWABLE LOADS DETERMINED IN ACCORDANCE WITH ASTM F2787, "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 7. ONLY CHAMBERS THAT ARE APPROVED BY THE SITE DESIGN ENGINEER WILL BE ALLOWED. THE CHAMBER MANUFACTURER SHALL SUBMIT THE FOLLOWING UPON REQUEST TO THE SITE DESIGN ENGINEER FOR APPROVAL BEFORE DELIVERING CHAMBERS TO THE PROJECT SITE: a. A STRUCTURAL EVALUATION SEALED BY A REGISTERED PROFESSIONAL ENGINEER THAT DEMONSTRATES THAT THE SAFETY FACTORS ARE GREATER THAN OR EQUAL TO 1.95 FOR DEAD LOAD AND 1.75 FOR LIVE LOAD, THE MINIMUM REQUIRED BY ASTM F2787 AND BY AASHTO FOR THERMOPLASTIC PIPE. b. A STRUCTURAL EVALUATION SEALED BY A REGISTERED PROFESSIONAL ENGINEER THAT DEMONSTRATES THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET. THE 50 YEAR CREEP MODULUS DATA SPECIFIED IN ASTM F2418 OR ASTM F2922 MUST BE USED AS PART OF THE AASHTO STRUCTURAL EVALUATION TO VERIFY LONG-TERM PERFORMANCE, c. STRUCTURAL CROSS SECTION DETAIL ON WHICH THE STRUCTURAL EVALUATION IS BASED. 8. CHAMBERS AND END CAPS SHALL BE PRODUCED AT AN ISO 9001 CERTIFIED MANUFACTURING FACILITY. 9. EMBEDMENT STONE SURROUNDING CHAMBERS MUST BE A CLEAN, CRUSHED, ANGULAR STONE 3/4-2" (20-50 mm). 10. THE CONTRACTOR MUST REPORT ANY DISCREPANCIES WITH CHAMBER FOUNDATION MATERIALS BEARING CAPACITIES TO THE SITE DESIGN ENGINEER. 11. ADS RECOMMENDS THE USE OF "FLEXSTORM CATCH IT" INSERTS DURING CONSTRUCTION FOR ALL INLETS TO PROTECT THE SUBSURFACE STORMWATER MANAGEMENT SYSTEM FROM CONSTRUCTION SITE RUNOFF. 12. STORMTECH SC-310 & SC-740 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH SC-310/SC-740/SG-780 CONSTRUCTION GUIDE". 13. THE USE OF CONSTRUCTION EQUIPMENT OVER SC-310 & SC-740 CHAMBERS IS LIMITED: a. NO EQUIPMENT IS ALLOWED ON BARE CHAMBERS. b. NO RUBBER TIRED LOADERS, DUMP TRUCKS, OR EXCAVATORS ARE ALLOWED UNTIL PROPER FILL DEPTHS ARE REACHED IN ACCORDANCE WITH THE "STORMTECH SC-310/SC740/DC780 CONSTRUCTION GUIDE". c. WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT CAN BE FOUND IN THE "STORMTECH SC-310/SC-740/DC-780 CONSTRUCTION GUIDE". 14. FULL 36" (900 MM) OF STABILIZED COVER MATERIALS OVER THE CHAMBERS IS REQUIRED FOR DUMP STRUCK TRAVEL OR DUMPING. USE OF A DOZER TO PUSH EMBEDMENT STONE BETWEEN THE ROWS OF CHAMBERS MAY CAUSE DAMAGE TO THE CHAMBERS AND IS NOT AN ACCEPTABLE BACKFILL METHOD. ANY CHAMBERS DAMAGED BY THE "DUMP AND PUSH" METHOD ARE NOT COVERED UNDER THE STORMTECH STANDARD WARRANTY. CONTACT STORMTECH AT 1-888-892-2694 WITH ANY QUESTIONS ON INSTALLATION REQUIREMENTS OR WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT. STORMTECH CONSTRUCTISEQUENCE 1. Storm Tech SC-310 Underground Storage shall not be installed until after the following: a. Approval from DENR Land Quality to remove the sediment basin. b. Approval from the Design Engineer to remove the sediment basin. c. On -site meeting with both the ADS representative AND the design engineer. d. All upstream areas (except the Tree Box Filter which should be offline) are to be stabilized. 2. Remove the existing sediment basin, 3. Remove all sediment from the bottom of the sediment basin. 4. Follow all directions from the "Stormtech SC-310/SC-740/SC-780 Construction Guide." S. Install the 6" stone base as shown on the plans. 6. The foundation stone shall be leveled and compacted prior to placing chambers. 7. Joints between chambers shall be properly seated prior to placing stone. 8. Maintain minimum 6" spacing between chamber rows. 9. Chambers are not to be backfilled with a dozer or an excavator situated over the chambers. The only appropriate backfill methods are: a. Stone Shooter Located off the Chamber Bed, b. Backfill as Rows are being Built using an excavator on the foundation stone or subgrade. c. Backfill from outside the excavation using a long boom hoe or excavator. 10. Contractor is responsible for keeping the installation area free and clear of sediment This may involve additional erosion control devices not shown on the plans. 11. Once the Stormtech device is in place and approved by the ADS representative and the design engineer, sod the area and complete the storm drainage from JMH #11 to GI #3. SURFACE LIVE LOADING CONDITION PIPE DIAM. H-25 HEAVY CONSTRUCTION (75T AXLE LOAD) 12" - 48" (300mm-1200mm) 12" (300mm) 46' (1200mm) 60" 1500mm 24" 600m m 1 60 500mm S SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321, STANDARD PRACTICE FOR UNDERGROUND VEHICLES IN EXCESS OF 75T MAY REQUIRE ADDITIONAL COVER INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS", LATEST ADDITION, WITH THE EXCEPTION THAT THE INITIAL BACKFILL MAY EXTEND TO THE CROWN OF THE PIPE. SOIL CLASSIFICATIONS TABLE 3, MAXIMUM COVER FOR ADS N-12 HP PIPE, ft ARE PER THE LATEST VERSION OF ASTM D2321. CLASS IVB MATERIALS (MH, CH) AS DEFINED IN PREVIOUS VERSIONS OF ASTM D2321 ARE NOT APPROPRIATE BACKFILL MATERIALS. 2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL, WHEN REQUIRED. 3. FOUNDATION: WHERE THE TRENCH BOTTOM IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTH REQUIRED BY THE ENGINEER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY THE ENGINEER. AS AN ALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH BOTTOM MAY BE STABILIZED USING A GEOTEXTILE MATERIAL, 4. BEDDING: SUITABLE MATERIAL SHALL BE CLASS 1, 11, III, OR IV. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. COMPACTION SHALL BE SPECIFIED BY THE ENGINEER IN ACCORDANCE WITH TABLE 3 FOR THE APPLICABLE FILL HEIGHTS LISTED. UNLESS OTHERWISE NOTED BY THE ENGINEER, MINIMUM BEDDING THICKNESS SHALL BE 4" (100mm) FOR 17-24" (300mm-600mm) DIAMETER PIPE; 6" (150mm) FOR 30"-60" (750mm-900mm) DIAMETER PIPE. THE MIDDLE 1/3 BENEATH THE PIPE INVERT SHALL BE LOOSELY PLACED. PLEASE NOTE, CLASS IV MATERIAL HAS LIMITED APPLICATION AND CAN BE DIFFICULT TO PLACE AND COMPACT; USE ONLY WITH THE APPROVAL OF A SOIL EXPERT. 5. INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS I, II, III, OR IV IN THE PIPE ZONE EXTENDING TO THE CROWN OF THE PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST EDITION. COMPACTION SHALL BE SPECIFIED BY THE ENGINEER IN ACCORDANCE WITH TABLE 3 FOR THE APPLICABLE FILL HEIGHTS LISTED. PLEASE NOTE, CLASS IV MATERIAL HAS LIMITED APPLICATION AND CAN BE DIFFICULT TO PLACE AND COMPACT; USE ONLY WITH THE APPROVAL OF A SOIL EXPERT. 6 MINIMUM COVER MINIMUM COVER H IN NON -TRAFFIC APPLICATIONS GRASS OR LANDSCAPE AREAS IS 12" 300mm FROM CLASS I CLASS 11 CLASS 111 CLASS IV PIPE DIA COMPACTED 957. 907. 85% 957. 90% 85% 857. 12" (300mm) 39 (11.9m) 27 (8 2m) 20 (6.1 m) 15 (4.6m) 21 (6.4m) 16 (4.9m) 14 (4.3m) 13 (4.0m) 15" (375mm) 42 (12.8m) 29 (8.8m) 21 (6.4m) 16 (4.9m) 22 (6.7m) 17 (5.2m) 15 (4.6m) 14 (4.3m) 181,36 (450mm) . (1 1Om) 25 (7.6m) 18 (5.5m) 13 (4.0m) 19 (5.8m) 14 (4.3m) 13 (4.0m) 12 (3.7m) 24' (600mm) 31 (9.4m) 22 (6.7m) 16 (4.9) 11 (3.4m) 16 (4.9m) 12 (3.7m) 11 (3.4m) 10 (3.0m) 30" (750mm) 36 (11.Om) 25 (7.6m) 18 (5.5m) 13 (4.0m) 19 (5.8m) 14 (4.3m) 13 (4.0m) 12 (3.7m) 36" (900mm) 32 (9.8m) 23 (7.0m) 16 (4.9m) 11 (3.4m) 16 (4.9m) 12 (3.7m) 11 (3.4m) 10 (3. Om) 42" 37 (11.3m) 25 18 13 18 13 12 9 1050mm (7.6m) (5.5m) (4.0m) (5.5m) (4.0m) (3.7m) (2.7m) 48" 35 (10.7m) 24 17 12 17 13 11 9 1200mm (7.3m) (5.2m) (3.7m) (5.2m) (4.0m) (3.4m) (2.7m) 60" 1500mm 37 (11.3m) 25 (7.6m) 17 (5.2m) 12 (3.7111) 18 (5.5m) 13 (4.0m) 11 (3.4m) 7 (2.1m) THE TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO PREVENT FLOTATION. FOR TRAFFIC FILL HEIGHT TABLE GENERATED USING AASHTO SECTION 12, LOAD APPLICATIONS; CLASS I OR II MATERIAL COMPACTED TO 90% SPD AND CLASS III COMPACTED TO 95% SPD IS REQUIRED. RESISTANCE FACTOR DESIGN (LRFD) PROCEDURE WITH THE FOLLOWING FOR TRAFFIC APPLICATIONS, MINIMUM COVER, H, IS 12" (300mm) UP TO 48" (1200mm) DIAMETER PIPE AND 24" (600mm) OF ASSUMPTIONS: COVER FOR 60" (1500mm) DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT HEIGHT OF WATER (Hw) =CROWN +1', UNIT WEIGHT OF SOIL (y 3) =120 PCF OR TO TOP OF RIGID PAVEMENT. CLASS IV MATERIALS ARE NOT RECOMMENDEDAS BACKFILL FOR TRAFFIC APPLICATION WITH LESS THAN 72" (1830mm) OF COVER MEASURED FROM TOP OF PIPE TO TOP OF SURFACE. N-12 HP STORM TRENCH INSTALLATION DET IL" L4J�1 IF SC-3' 12" HDF MANHOLE MEETR LOCAL CODI OVERFLOW WEIR STAGES OF S' ISOLATOR kUVV I VVI-_-IK Lslit7N I TYPICALLY SET AS ACCEPTS 4" [100 mm] SCH 40 PVC PIPE FOR INSPECTION PORT 90.7" [2304 mm] ACTUAL /0%71[406 mm] 34 [864 mm] NOMINAL CHAMBER SPECIFICATIONS SIZE (W x H x INSTALLED LENGTH) 34.0" x 16.0" x 85.4" [864 mm x 406 mm x 2169 mm] CHAMBER STORAGE 14.7 CUBIC FEET [0.42 rn j MINIMUM INSTALLED STORAGE 31.0 CUBIC FEET [0.88 ml WEIGHT 35 lbs. [16.8 kg] STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B" STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH 'IT" PART# STUB A B IC SC310EPE06T 6" [150 mm] 9.60" [244 mm] 5,80" [147 mm] N/A SC310EPE06B 6" 150 mm MY* 244 mm N/A 0.50" 13 mm SC310EPEOBT 8" 200 mm 11.90" 302 mm 3.50" 89 mm N/A SC310EPE088 8" [200 mm] 11.90" 302 mm N/A 0.60" 15 mm SC310EPE10T 10" 250 mm 12.70" 323 mm 1.40" 36 mm N/A SC310EPEIOB 10" 250 mm 12 70" 323 mm N/A 0.70" 18 mm *SC310EPE12B 12" [300 mm] 13.50" [343 mm] NIA 0,90" [23 mm] ALL STUBS, EXCEPT FOR THE SC310EPE12B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF THE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT 1-888-892-2694. *FOR THE SC310EPE12B THE 12" [300 mm] STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 0.26" [6 mm]. BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL. NOTE: ALL DIMENSIONS ARE NOMINAL SC-310 TECHNICAL SPECIFICATIONS SCALE: NTS AwA"cEa mwNACE aremus, INa " awua•a„.w,.wwv _.- Subsurface Startmvatermanagement" DATE: 3/30/10 SIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. 70 INWOOD ROAD, SUITE 3 1 ROCKY HILL, CT 06087 :UIIMATERESPONSNDALLOFTOCIATE DETAILS ERTOENSURETHAT PHONE:888892-2694 1 FAX:866328NOI DRAWN BY: KLJ SOLICITS)IATI NS ANEDAND ALL ASSOCIATED DETAILS MEET ALLAPPLICASLE IFGDI ATIQN.S AND PRf]IFDT RFOHIRFMFNTS WWW.STORMTEGIi.COM CHECKED: Storm Tech SC-310 Undergroung Storage Elevations Ground Surface 621.50 Top of Stone 619.23 Top of Chamber 618.73 Top of Inlet Structure 621.50 Inlet Structure Invert 617.40 Inlet Structure Weir 618.73 Inlet Structure Surnp 615.40 Bottom of Isolator Row 617.40 Bottom of Chamber 617.40 Bottom of Stone 616.90 6" Perforated Underdrain Invert 617.20 Top of OC 621.75 Overflow Weir 618.98 Invert of OC Structure 617.10 Inver of Downstream YI 617.00 Cove r (ft) 2.77 Inlet Structure Freeboard (ft) 2.77 Outlet Structure Freeboard (ft) 2.77 Chamber Height ft) 1.33 18" SMOOTH WALLED HPPP-RI7'1 INLET CONTROL MANHOLE WITH WEIR rya s, a .4 ((WEIR DETAILS AND ELEVATIONS TBD BY DESIGN ENGINEER) ♦ggeg gHE1!®,`®t`bo REVISED 11-18-13 ADDENDUM #1 d. 0 1 lo !: air 001:11111101ITMAILGIL °.a 4' X 4' YARD INLET TOP - 622.50 RIM ELEVATION - 621.75 4' X 4' YARD INLET WEIR PLATE ELEVATION - 618.98