Loading...
HomeMy WebLinkAboutSW5210301_Add Info Request_20210409ROY COOPER - a Governor y a2 DIONNE DELLI-GATTI �.�xi *�`�^'^0"'* Secretary BRIAN WRENN NORTH CAROLINA Director Environmental Quality April 9, 2021 Richard Butt, PE John Davenport Engineering, Inc. 119 Brookstown Avenue, Suite PH 1 Winston-Salem, NC 27101 Subject: Request for Additional Information Stormwater Permit No. SW5210301 North Carolina Central University School of Business Durham County Dear Mr. Butt: The Division of Energy, Mineral and Land Resources (DEMLR), received a Stormwater Management Permit Application for the subject project on March 9, 2021. A review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. Please submit a completed, signed, and sealed Supplement EZ form for the wet pond. The form can be found on the Stormwater Design Manual Web Page. 2. Please upload a signed and notarized copy of the O&M Agreement. Please also note that there is a new O&M EZ form available on the Stormwater Design Manual Web Page. 3. The calculations show that the calculated water quality volume was based on the new impervious area only. While the rules only require that this area be treated, if the drainage area to the SCM exceeds the minimum area, then the SCM has to be designed to treat the actual contributory drainage area. Therefore, the wet pond must be designed using the runoff volume from the entire drainage area as the water quality volume [I 5A NCAC 02H .1050(1)]. 4. When calculating the average depth of the wet pond, the permanent pool volume of the entire wet pond, including the forebay, was used. The average depth must be calculated using only the volume of the main pool (Wet Pond MDC 2). 5. The calculation for the drawdown time used a water quality volume that was different than the calculated water quality volume. The MDC require that the drawdown time of the water quality volume be between 2 and 5 days (Wet Pond MDC 7). North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources 512 North Salisbury Street 1 1612 Mail Service Center I Raleigh, North Carolina 27699-1612 NORTH CAROLINA uepaa nt of enmmnmmi Q.1; 919.707.9200 6. Provide pdfs of all revisions, 2 hardcopies of revised plan sheets, and 1 hardcopy of other documents. Pdfs must be uploaded using the form at: https:Hedoes.deq.nc.gov/Forms/SW ProjectSubmittal Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to May 8, 2021, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. Please reference the State assigned project number SW5210301 on all correspondence. If you need additional time to submit the information, please submit your request for a time extension to the Division at the contact below. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. If you have any questions concerning this matter please feel free to contact me at Corey.Anenkncdenr. _gov or (919) 707-3649. Please note that due to the ongoing Covid-19 pandemic, I will be teleworking and will be most easily reached by email. Sincerely, Steven Corey Anen, PE Environmental Engineer Stormwater Program cc: Raleigh Regional Office D E Q�� North Carolina Department of Environmental Quality Division of Energy, Mineral and Land Resources 512 North Salisbury Street 1 1612 Mail Service Center Raleigh, North Carolina 27699-1612 NORTH CAROLINA - D.panm.mof Envlloamaotal Duality 919.707.9200