Loading...
HomeMy WebLinkAboutWI0700012_Site Plans/Maps_20170929N 89+00 N 88+00 N 87+00 N 86+00 N 85+00 N 79+00 N 78+00 N 77+00 f, Z 8 W 8 co W OFFICE 8 BARGE SUP 8 W ASPHALT ROAD 8 W 8 cm W cwW-2_- • )CWW--3 __ CWW-a • CWW-5 ,C� PIPERACK SPILL CONTAINMENT PAD 8 W 8 A CROATAN FORMATION WITHDRAWAL WELL (TYPICAL) CWW-6 CWW-7 8 W 1 T 8 W CROATAN FORMATION INJECTION WELL (TYPICAL) E 2: 0 0 CO W POTENTIOMETRIC SURFACE ELEVATION IN CROATAN FORMATION (FEET, MSL) 0 SCALE 100 200 1"=100' ��PROJECTED OTENTIOMETRIC SURFACE MAP OF CROATAN FORMATION DURING OPERATION OF REMEDIAL ACTION SYSTEM Ardaman & Associates, Inc. Consulting Engineers in Soils, Hydrogeology, Foundations, and Materials Testing TANK FARM REMEDIAL ACTION PLAN Texasgulfinc elf aquitaine group DRAWN BY: KJS FILE NO. 88-089 CHECKED BY:j APPROVED VED BY: ( DATE: 7-18-90 FIGURE 4-5 FERT-1 AFERT-3 MONITOR WELLS 3A 3B 3C MWTF-3 0 0 0 0 65 130 APPROXIMATE SCALE 1 "=65'± FLIGHT DATE 06/02/90 LEGEND STANDARD PENETRATION TEST BORING COMPLETED FOR TANK FARM REMEDIAL ACTION PLAN EXISTING GROUNDWATER MONITOR WELLS 0 EXISTING SURFICAL DEPOSITS AND CROATAN FORMATION TEST WELLS A EXISTING CASTLE HAYNE AQUIFER UTILITY WELL DRAWING NO. LIST OF DRAWINGS TITLE 1 TANK FARM AERIAL PHOTOGRAPH AND BORING, MONITOR WELL AND TEST WELL LOCATION PLAN 2 LAYOUT OF TANK FARM REMEDIAL ACTION SYSTEM 3 SITE PLAN FOR SOIL-BENTONITE CUT-OFF WALL AND CONFINED SAND AND CROATAN FORMATION WITHDRAWAL WELL SYSTEM 4 SITE PLAN FOR SOIL-BENTONITE CUT-OFF WALL AND CONFINED SAND AND CROATAN FORMATION WITHDRAWAL WELL SYSTEM 5 PROFILE ALONG SOIL-BENTONITE CUT-OFF WALL AND TYPICAL SECTIONS AND DETAILS 6 TYPICAL DETAILS FOR CONFINED SAND AND CROATAN FORMATION WITHDRAWAL WELL SYSTEMS 7 TYPICAL CROSS SECTION AND DETAILS FOR CONFINED SAND AND CROATAN FORMATION WITHDRAWAL WELL SYSTEM 8 TYPICAL CROSS SECTIONS AND DETAILS FOR CROATAN FORMATION INJECTION WELL SYSTEM 9 f SOIL BORINGS ALONG SOIL-BENTONITE CUT-OFF WALL AND CONFINED SAND AND CROATAN FORMATION WITHDRAWAL WELL SYSTEM ALIGNMENT 10 SOIL BORINGS ALONG SOIL-BENTONITE CUT-OFF WALL AND CONFINED SAND AND CROATAN FORMATION WITHDRAWAL WELL SYSTEM ALIGNMENT 11 SOIL BORINGS ALONG CROATION FORMATION INJECTION WELL SYSTEM ALIGNMENT TANK FARM AERIAL PHOTOGRAPH AND BORING, MONITOR WELL AND TEST WELL LOCATION PLAN isidlli Consulting Engineers in Soils, Hydrogeology, Foundations, and Materials Testing Ardaman & Associates, Inc. TANK FARM REMEDIAL ACTION PLAN Texasgulf ,c. 1 10 17 90 Al 7'31 /90 ISSUED FOR BIDS ISSUED FOR DEM REVIEW elf aquitaine group DESCRIPTION APPR'D BY ENGINEERING JOB NO.: AFE-N-763 DRAWING NO.: 1 DRAWN BY: FILE NO: 88-089 KJS CHECKED BY: APPROVED BY: . DATE: 7-9-90 0 N 88+00 36' CULVERT INV. 6.6' N 87+00 SPZ-1 4INV. 6.51-1 / CPZ-1 ) // III III Di N N 86+00 PIPE RACK (REF) N 85+00 N 84+00 N 83+00 N 82+00 N 81+00 NORTH 40 SCALE INV. 4.0' W 3 d1N n�� INV. 7.9' I w -1 -1- 11.8' 11.2' 80 1 "=40' 0 Cs 04 >c- W L18•ACP @1 27% INV. 6.9' INV. 6 5' ELECTRIC EQUIPMENT P.P r 112�TF-104 X Y 42' CULVERT TF-102 ,X113' ASPHALT MCC SPACE, CONTROL BARGE SLIP FUEL STORAGE 2' HDPE DISCHARGE PIPE AND 2' HDPE AIR LINE TO EACH WELL ASPHALT ROAD MWTF-2 MINA r MOW -_• w^F INV. 5.5' 3CPZ-2 FIELD LOCATE CUT-OFF WALL 75' FROM BARGE SLIP -i- MONITOR WETLS TANK FARM WELL S.P.A. PLANT (REF) INV. 4.83' 36' ACP @0.81%-iy TOP OF STEEL GRATE EL 11 7' X 11 2' F-101 VERIFY EL OF18'AND 38' PIPES AT CROSSING IN FIELD CONCRETE TRENCH WITH STEEL PLATE COVER INV. 8.5 SULFURIC - ACID TANK 6' HOPE --1= PETRO A.G. TANK T 750 LF-2.5' THICK SOIL-BENTONITE BACKFILL CUT-OFF WALL 1 PIPE RACK (REF) -{ + 0 0 + N w LEGEND O + rn N_ w swW cww CIW co CONFINED SAND LAYER WITHDRAWAL WELL CROATAN FORMATION WITHDRAWAL WELL CROATAN FORMATION INJECTION WELL INJECTION WELL HEADER PIPE CLEAN -OUT SOIL BORING PIEZOMETER 1- - INV. 6.0' '- 2-30' CULVERTS MCC BUILDING SPZ-9 CPZ-3 S.P.A. PLANT (REF) PIPE RACK COLUMNS (TYP.) C.B. T.O.G. 11.0' INV. 8.8' PIPE RACK (REF.) INJECTION WELL WATER SUPPLY AND WATER LEVEL CONTROL TANK 2-43"X27" INV. 5 87/ CONCRETE HEADWALL CMP ARCH---1 11-37-0 PLANT (REF) PIPE RACK (REF) 0 O + 0 c) w INV. 6.3' 30' CULVERT CONTROL VALVES AND FLOW TOTALIZERS FOR GROUNDWATER DISCHARGE AND AIR LINES PIPE RACK (REF) I )SUMP II SPA POND - WATER RETURN ,I CONCRETE SPILL CONTAINMENT AREA BELOW PIPE RACK 30' PIPE ABANDONED SEPTIC FIELD 4" HDPE INJECTION WELL HEADER PIPE Ct EL 5.0' INV. 6.9' ASPHALT ROAD MONITOR WEU.S INV. 6.8' SWW-5 I `610' IIFLASH TANKS - - - - MWTF-1 / IISUMP INV. 5/25' j/INV. 5.63'-I C.B. / Tor1115' IN" 560 + 0 0 + M w VERIFY OLD 18" CMP NORTH OF C.B. WAS REMOVED IN FIELD TO SUMP 4------- CONCRETE CONTAINMENT AREA;;: 18•CMP INV. 5.96' CATCH BASIN T.O.G. 6.7' INV. 5.4' -� 8' AW2-71743 M -'10.7'ATCO-3 N 16.3' AT WELL CIW-7 x 0. 1' t RETAINING WALL INV. 8.6' -0-15' HOPE CULVERT A FUEL OIL DAY TAN 011 EXISTING GROUND SURFACE = fi EXIST. 8' AW2-71769 4" HDPE INJECTION WELL HEADER PIPE 2-43"x27" CMP ARCHES INV. 5.6' AT CO-3 INV. 5.4' AT WELL CIW-7 6" MIN. CLEARANCE BETWEEN CMP AND HDPE HEADER PIPE SECTION A -A SCALE: 1 /4'= l'-0' 15' HDPE CULVERT-}- - CONC SLOPE II I I I II II II I I I I I I CC..B. INV. 7 3' 5II all GRAVEL ROADWAY ('i"§PZ-8 S TF-107 PIPE RACK (REF) PIPE RACK (REF) TF-100 12.7' X Z-10 WASH RACK 8' AW2-71769 M.H. TOP 10.6' INV. 7 7' 12" CMP C.B. INV. 6.75' T.O.G. 9.20' + M.H. TOP 12 0' INV 5 35' + 2-43')¢7' CMP ARCH M.H. TOP 11.5' INV. 5.23' + + TF-106 J U) 2 w w LL ELEVATION 12 8 4 0 N 88+00 N 86+00 N 84+00 N 82+00 00+L£L 3 00+££L 3 CLEAN ACID FACILITIES SITE DRAINAGE AND UNDERGROUND PIPING PLAN, DRAWING CE-00008, REV. 9. SPA TANK FARM EXISTING AND PROPOSED TANK LOCATIONS,DRAWING DOG-071-047, REV. 2. SUPERPHOSPHORIC ACID AREA AND BLEND TANKS PLOT PLAN, DRAWING DOG-080-007B, REV. B. DAP BLEND AND 54%P205 TANK AREA GRADING, PAVING AND UNDERGROUND PLAN, SHEET NO. 1, DRAWING DOG-071-040A, REV. A. DAP BLEND AND 54%P205 TANK AREA GRADING, PAVING AND UNDERGROUND PLAN, SHEET NO. 2, DRAWING DOG-071-043. H2SO4 AND PETRO AG TANK AREA GRADING, DRAINAGE AND PROCESS SEWAGE PLAN, SECTIONS AND DETAILS, DRAWING DOG-071-044A, REV. A. PLUMBING - AREA 60, SANITARY SEWER - PHASE II, PLAN & PROFILE, DRAWING DPL-060-002 REFERENCE DRAWINGS AND KEY PLAN 0 75 150 SCALE- 1"=150' ± co-1 18" A.C.P. @ 1.27% N 8' SOUTH OF HEADER PIPE 8 c0+ N_ w CONCRETE TRENCH I N V.8.0' FIELD VERIFY EL OF 18" AND 36" PIPES AT CROSSING E 128+48.75 36" A.C.P. INV. 4.5' + N w M U E 128+73.5 18" A.C.P. INV. 6.5' E 129+45 6" C.LP. INV. 7.7' FIELD CHECK FOR PIPE AT E 129+62± E 128+95 4" C.I.P. INV. 4.0' 4" HDPE INJECTION WELL HEADER PIPE INV. 4.8' LTJ (- E 130+68 30" PIPE INV. 5.2' I � I 8 8 8 pp+� w 8 + w PROFILE ALONG INJECTION WELL HEADER PIPE FROM CIW-1 TO CIW-4 HORIZONTAL SCALE: 1'=40' VERTICAL SCALE: 1'=4' To- 4 4/16/96 REVISE TANK 006, 007. 008, 009, 013, 015. 017. 019, 021, 023 AND 028 LOCATIONS AND ADD CONTAINMENT AREA 141 3 8/6/91 ADD AS -BUILT WITHDRAWAL WELL AND PIEZOMETER LOCATIONS 2 6/18/91 ADD SECTION A- A, PROFILE, AND PIPELINES RELOCATE SUPPLY TANK, AND ADJUST HEADER PIPE ALIGNMENT 1 4/15/91 ISSUED FOR CONSTRUCTION, REVISE CUT-OFF WALL ALIGNMENT AND WITHDRAWAL WELL LOCATIONS, ADD EXISTING SEWER UNE AND REFERENCE DRAWING 7 0 10/17/90 ISSUED FOR BIDS LAYOUT OF TANK FARM REMEDIAL ACTION SYSTEM Ardaman & Associates, Inc. Consulting Engineers in Soils, Hydrogeology, Foundations, and Materials Testing TANK FARM REMEDIAL ACTION PLAN PCS PhosphatecV AURORA DIVISION P1 7/31/90 ISSUED FOR DEM REVIEW REVISION DATE DESCRIPTION APPR'D BY ENGINEERING JOB NO.: AFE-N-763 DRAWING NO.: 2 DRAWN BY: KJS CHECKED BY: ( 1 DATE: 7-9-90 FILE NO. 88-089 APPROVED BY: F. 0 w w LL 10 20 30 40 50 60 H a W al 70 5/12/90 0 SCALE TH-101 DRILLED 5/12/90 40' 80 1 "=40' 25 -200=98 LL=102 PI=75 NM=88 -200=95 LL=119 PI=87 NM=34 -200=35 COMPLETE - CIRCULATION LOSS AT 39' NM=24 -200=8 18 10 10 CrFm YFm BROWN SLIGHTLY SILTY FINE SAND WITH TRACE SHELL FRAGMENTS (SP-SM) BROWN SUGHTLY SILTY FINE SAND WITH TRACE SHELL FRAGMENTS AND THIN LAYERS OF CLAYEY FINE SAND (SP-SM) GRAY SLIGHTLY CLAYEY TO CLAYEY SAND WITH ROOTS (SC) DARK BROWN CLAY WITH LAYERS OF FINE SAND (CH) DARK BROWN CLAY (CH) GREENISH -GRAY CLAY WITH SHELL FRAGMENTS (CH) GRAY CLAYEY SAND AND SHELL FRAGMENTS (SC AND SHELL) GRAY FINE SAND AND SHELL FRAGMENTS (SP AND SHELL) GRAY SLIGHTLY CLAYEY SAND AND SHELL FRAGMENTS WITH THIN LAYERS OF CEMENTED SAND AND SHELL FRAGMENTS (SC AND SHELL) GREENISH -GRAY CLAYEY FINE SAND WITH TRACE SHELL FRAGMENTS (SC) GREENISH -GRAY CLAYEY FINE SAND (SC) O 0 CO N w S.P.A. PLANT (REF) MCC SPACE / CON1HUL 0 0 + m N w C.B. I T.O.G. 11.0' rIMV. QQ SS SUTAIRC ACID TANK 6=HOPE �= PETRO A.G. TANK TF-110 DRILLED 6/14/90 0 0 O r- T w S.P.A. PLANT (REF) PIPE RACK COLUMNS 7 (TYP.) \' TF-110 VERIFY PIPE LOCATION 0 0 T w 1000 GAL. SEPTIC TANK SEPTIC TSUMP JI FIELD 1 II 11 I 1 I SUMP II NO. 4 EVAP. PRODUCT TANK PIPE RACK (REF) -► X 11.7' SPA POND -� WATER RETURN SUMP AND PUMP SUMP i 30' PIPE INV. 5.1' /2-43'X27' ARCH. CMP-7 MN. 5.5 CX5NCRETE ROTARY WASH 2 DARK BROWN CLAY WITH THIN LENSES OF GRAY FINE SAND AND WITH TRACE SHELL FRAGMENTS (CH) GREENISH -GRAY CLAY WITH TRACE SHELL FRAGMENTS (CH) 10.9' x FLASH TANKS FOR WENS I� II I AIM � os - INV. 5.63' �'IPE RACK (REF) TEMPORARY EARTH BERM C.B. T.O.G. 11.5' INV. 5.60' r- r� _a -s SM. _r= 11.3' C.B. INV. 6.17' T.O.G. 9.00' VERIFY OLD 18• CMP NORTH OF C.B. WAS REMOVED NM=22 -200=13 NM=24 -200=59 NM=23 -200=20 NM=31 MWTF-1 DRILLED 10/25/88 A B N CATCH BASIN T.O.G. 8.7' INV. 5.4' 0 0 w ELECTRICAL SUBSTATION ::- C FUEL OIL DAY TAN 10. J E 143+00 • • PIPE RACK (REF) 12.r X ---TF-10o WASH RACK 8• AW2.71789 M.H. TOP 10.6' INV. 7.T I \ lIx 0.3 I II I I INV. 6.50' I-t2• CMP C.B. NV. 6.75' T.O.0. 5.90' -200=47 NM=29 -_ -200=30 NM=55 -200=89 12 22 9 10 14 NM-34 -200=25 NM-28 -200=12 NM=25 -200=16 COMPLETE CIRCULATION LOSS AT 42' NM=9 - -200=7 NM-22 -200=43 1 a O6 o 69 .. NOTE: FOR LEGEND AND GENERAL NOTES SEE DRAWING 10 CrFm YFm1 SAMPUNG DATE 04/17/90 pH=8.6 TDS=252mgfl SO4=44mg/1 CI=8mg/I F=7.8mg/1 P-4.5m9fl TOC=12mg/I SAMPUNG DATE 17/90 pH=5.2 TDS=524mg/I SO4=28mgfl CI=199mg/1 F-0.30mg/1 P=0.45mg/1 TOC=4mg/1 SAMPUNG DATE 04/17/90 pH=8.8 TDS=560mgn 504=77mgfl CI=55mg/I F=0.80mgfl P=0.30mgfl TOC-4mg/I LIGHT BROWN FINE SAND (SP) LIGHT GRAY FINE SAND WITH SMALL BALLS OF CLAYEY FINE SAND (SP) DARK BROWN CLAYEY FINE SAND WITH ROOTS (SC) GRAY AND YELLOWISH -BROWN SANDY CLAY (CU DAFT( BROWN PLASTIC CLAY (CH) BROWN SILTY FINE SAND (SM) BROWN CLAYEY FINE SAND WITH SEAMS OF FINE SAND (SC) DARK GRAY CLAYEY SAND WITH SEAMS OF FINE SAND (SC) GREENISH -GRAY CLAY WITH SHELL FRAGMENTS (CH) GREENISH -GRAY CLAYEY FINE SAND WITH SHELL FRAGMENTS (SC) GREENISH -GRAY SLIGHTLY CLAYEY FINE SAND AND SHELL FRAGMENTS (SC AND SHELL) GREENISH -GRAY SILTY FINE SAND WITH TRACES OF CLAYEY SAND AND SHELL FRAGMENTS (SM) GRAY SUGHTLY SILTY MEDIUM TO FINE SAND WITH SOME SHELL FRAGMENTS AND THIN LAYERS OF CEMENTED SAND (SP-SM) GREENISH -GRAY CLAYEY FINE SAND (SC) GREENISH -GRAY CLAYEY FINE SAND WITH THIN LAYERS OF SANDY CLAY (SC) GREENISH -GRAY CLAYEY FINE SAND (SC) N1 Ij� 11 NI N1 11 NI x 12.r M.M. TOP 12.0' INV. 5.35' 2-47'1(27' AR M.M. TOP 11.5' INV. 5,SY N 84+00 N 83+00 N 82+00 5/11/90 NM=36 -200=28 NM=21 -200=5 NM=22 -200=6 NM-84 -200=87 LL=112 PI=82 NM-31 -200=14 COMPLETE CIRCULATION LOSS AT 39.5' NM=19 -200=6 NM=17 -200=9 NM=28 -200=20 TH-100 DRILLED 5/11/88 6 29 41 15 31 10 16 27 59 10 CrFm YFm BROWN FINE SAND (SP) GRAY FINE SAND WITH THIN LAYERS (1'-2) OF GRAY CLAYEY FINE SAND WITH TRACES OF SHELL FRAGMENTS (SP) BROWN SILTY FINE SAND (SM) GRAY TO BROWN SLIGHTLY SILTY FINE SAND WITH SOME THIN CLAYEY SAND LAYERS (SP-SM) GRAY SUGHTLY SILTY MEDIUM TO FINE SAND (SP-SM) DARK GRAY SANDY CLAY WITH TRACE SHELL FRAGMENTS (CH) GREENISH -GRAY CLAY WITH TRACE SHELL FRAGMENTS (CH) SHELL FRAGMENTS AND GRAY SLIGHTLY CLAYEY FINE SAND (SHELL AND SC) GRAY SUGHTLY SILTY FINE SAND WrrH TRACE SHELL FRAGMENTS (SP-SM) GRAY SUGHTLY SILTY FINE SAND WITH TRACE SHELL FRAGMENTS AND SOME THIN LAYERS OF CLAYEY SAND (SP-SM) GRAY CLAYEY FINE SAND WITH TRACE SHELL FRAGMENTS (SC) GREENISH -GRAY CLAYEY FINE SAND (SC) lo0 20 30 40 50 60 W LL a w 70 0 SOIL BORINGS ALONG CROATAN FORMATION INJECTION WELL SYSTEM ALIGNMENT Ardaman & Associates, Inc. Consulting Engineers in Soils, Hydrogeology, Foundations, and Materials Testing TANK FARM REMEDIAL ACTION PLAN Texasgulf inc. 0 10/17/90 ISSUED FOR BIDS elf aquitaine group P1 7/31/90 ISSUED FOR DEM REVIEW REVISION DATE DESCRIPTION APPR'D BY ENGINEERING JOB NO.: AFE-N-763 DRAWING NO.: 11 DRAWN BY: KJS FILE NO. APPRO 88-089 CHECKED BY:iA ED BY: DATE: 7-9-90 APPROXIMATE DEPTH 25 30 35 40 45 50 DEPTH VARIES (SEE SOIL BORINGS) 2' THICKNESS VARIES (SEE SOIL BORINGS) 1' 1' MIN 1 in 0 \w9WJ,C\\y. 0: on; °°1 NEAT CEMENT GROUT (6 GALLONS OF WATER PER 94 Ib. SACK OF CEMENT WITH 4 TO 4.5 Ib. OF BENTONITE) 4' DIA. PVC GLUE -JOINT PVC WELL CASING 12' DIA. BOREHOLE 2' THICK TAMPED BENTONITE SEAL TOP OF CROATAN FORMATION i• • e• 1' THICK 20/30 SILICA SAND STAINLESS STEEL CENTRALIZER SILICA GRAVEL FILTER 4' DIA. PVC SLOTTED WELL SCREEN WfTH 0.040" WIDE SLOTS 2' LONG - 4' DIA. PVC TAILPIPE TOP OF YORKTOWN FORMATION \ 4' DIA. PVC SOCKET -TYPE END CAP DETAIL F - INJECTION WELL NOT TO SCALE GRADE TO MATCH EXISTING GROUND SURFACE ELEVATION COMPACTED GRANULAR BACKFILL 2± 4' DIA. PVC — SOCKET -TYPE 45' BENDS 4' DIA. PVC HEADER PIPE EL 5.0' BROOKS PRODUCTS, INC. 8-3/4' DIA. eeNeRETE-TrAFFIC -EO'F :u'TL CADT IRON COVER 4' DIA. PVC THREADED CLEAN -OUT PLUG 4k4k6' THICK CONCRETE PAD 4' DIA. PVC CLEAN -OUT ADAPTER TOP EL 10.5' MIN. SAND TAIUNGS FILL BETWEEN PIPE AND TRAFFIC BOX 4' DIA. PVC PIPE COMPACTED SAND TAILINGS BACKFILL DETAIL H - INJECTION WELL HEADER PIPE CLEAN -OUT SCALE: 1/2' = 1'-0' 4" DIA. PVC THREADED CLEAN -OUT PLUG 4' DIA. PVC CLEAN -OUT ADAPTER TOP EL. 10.5' MIN. EXCAVATE MINIMUM TRENCH WIDTH REQUIRED FOR PIPE INSTALLATION COMPACTED SAND TAILINGS BACKFILL 4' DIA. PVC SOCKET -TYPE TEE BROOKS PRODUCTS, INC. 8-3/4' DIA. CONCRETE TRAFFIC BOX WITH CAST IRON COVER 4k4k6' THICK CONCRETE PAD GRADE TO MATCH EXISTING GROUND 18 \ SURFACE ELEVATION 1 SAND TAIUNGS FILL BETWEEN PIPE AND TRAFFIC BOX COMPACTED GRANULAR BACKFILL 4' DIA. PVC RISER PIPE 4' DIA. PVC SOCKET -TYPE TEE ON HEADER PIPE c. EL 5.0' 4' DIA. PVC PIPE NEAT CEMENT GROUT 4' DIA. PVC GLUE -JOINT PVC WELL CASING DETAIL G - INJECTION WELL TO HEADER PIPE AND RISER PIPE CONNECTION GRADE TO MATCH EXISTING GROUND SURFACE ELEVATION 4' DIA. PVC HEADER PIPE Q. EL. 5.0' SCALE: 1/2' = 1'-0' REPLACE ASPHALT PAVEMENT ALONG PORTIONS OF TRENCH IN PAVED AREAS (SEE ASPHALT PAVEMENT DETAIL) EXCAVATE MINIMUM TRENCH WIDTH REQUIRED FOR PIPE INSTALLATION COMPACTED SAND TAILINGS BACKFILL DETAIL I - TYPICAL TRENCH BACKFILL SCALE: 1/2' = 1'-0° 12' DIA. BOREHOLE 4' DIA. PVC SOCKET -TYPE TEE ON WELL CASING 4' DIA. PVC PIPE 18' MIN. SECTION B - B SCALE: 1' = 1'-0' WATER RESISTANT LID 2" FRESH WATER A, METER BOX SUPPLY LINE 2' GATE VALVE 2' TOTALIZING METER 2' FLOAT VALVE 4' DIA. PVC HEADER PIPE TO INJECTION WELLS EL. 5.0' 4' DIA. PVC HEADER PIPE EL. 5.0' 4' DIA. PVC SOCKET -TYPE TEE PITLESS ADAPTER 2' GALVANIZED DROP PIPE TO BE ADJUSTABLE TO SET WATER LEVEL IN TANK FROM EL. 5.0' TO 15.0' MSL (INITIAL WATER LEVEL TO BE SET AT EL. 10.0' MSL) EXISTING GROUND f;URFACE EL. 12.0'± FLOAT 18' DIA. STEEL PIPE BOTTOM OF TANK AT EL. 40' DETAIL J - INJECTION WELL WATER LEVEL CONTROL TANK SCALE: 3/8' = 1'-0" TYPICAL DETAILS FOR CROATAN FORMATION INJECTION WELL SYSTEM Ardaman & Associates, Inc. Consulting Engineers in Soils, Hydrogeology, Foundations, and Materials Testing TANK FARM REMEDIAL ACTION PLAN Texasgulfnc. 0 10/17/90 ISSUED FOR. BIDS elf aquitaine group P1 7/31/90 ISSUED FOR DEM REVIEW REVISION DATE DESCRIPTION APPR'D BY ENGINEERING JOB NO.: AFE-N-763 DRAW NG NO.: 8 DRAWN BY: RBE FILE NO. 88-089 CHECKED BY:7-A APPROVED BY: DATE: 7-9-90 i BARGE SLIP - INV. 6.9' N 88+00 38' CULVERT INV. 6.6' N 87+00 tz 0 ";TF-104 FUEL STORAGE 2' HOPE DISCHARGE PIPE AND 2' HDPE AIR LINE TO EACH WELL OCPZ-2 FIELD LOCATE CUT-OFF WALL 75' FROM BARGE SLIP f + 750 LF-2.5' THICK SOIL-BENTONITE BACKFILL CUT-OFF WALL LIQUID FERTILIZER TANK SPZ-1 �(NV.6.51i cPz-1 0 III oil I N 86+00 N 85+00 INV. 6.9' INV. 6.5' ELECTRIC EQUIPMENT SUBSTATION ASPHALT ROAD MwTF-2 • ■ wow, * taaam imam In wow a mow- ammo " 42' CULVERT 2A 0280 1 2C 'filiFJ��'t . VOW IH wr.ING WAL I 1 ) SPZ-6 trii5 INV, 8 6' 15' HOPE CULVERT -_ 1 15' HOPE cu vERT-I- (/' MN. 6.7' "T II _ MONITOR WETLS SWW-2 INV. 5.5' EXIS`T1NG BUILDING TF - INV. 6.4' \- INV. 6 0' 2-30' CULVERTS INV 6.8' INV. 6.3' 30' CULVERT PIPE RACK (REF), CONCRETE SPILL CONTAINMENT AREA BELOW PIPE RACK INV. 8.9' C B. INV 7.3' �II II II II 3\ GRAVEL ROADWAY 5 TF-106 - CONC. SLOPE PIPE RACK (REF) PIPE RACK (REF) - N 84+00 0 N 83+00 N 82+00 \INV. 4.0' OVERHEAD POWERLINE \ T1' 11.2' N 81+00 NORTH SCALE 40 80 1 "=40' $ 04 @1.27% TF-102 TO SUMP - MCC SPACE / CONTROL + / ASPHALT INV. 8.87' MCC BUILDING INV. 61' MONOLITHIC CONC. TRENCH PIPE RACK (REF) S.P.A. PLANT (REF) P 11 @36'0.81AC% : TOP OF STEEL GRATE EL t 1.7'- 11I OFFICE 5 CHANGE HOUSE VERIFY EL OF ir AND 36' PIPES AT CROSSING IN FIELD CONCRETE TRENCH WITH STEEL PLATE COVER - O + co N r- w INV 8.0' INV. 6 5' - { CNb 2, 4" C.I.P. WATER LINE LEGEND SULFURIC - ACIO TANK INV. 10.0' INV. 9.76' S.P.A. PLANT (REF) PIPE RACK COLUMNS (TYP.) - - - C. B. TO.G.110. INV 8.6' INJECTION WELL WATER SUPPLY AND WATER LEVEL CONTROL TANK /2 43"X27CMP ARCH CONCRETE HEADWALL 11-37-0 PLANT (REF) O N w SWW cwW CIW CO s CONFINED SAND LAYER WITHDRAWAL WELL CROATAN FORMATION WITHDRAWAL WELL CROATAN FORMATION INJECTION WELL INJECTION WELL HEADER PIPE CLEAN -OUT SOIL BORING PIEZOMETER \1000 GAL SEPTIC TANK I L--} -----1 - NO 4 EVAP. PRODUCT TANK 3I)Mf' • WEU HEADER PIP ) EL 50' ID9' x 1 :VY PIPI INV 5 t 0 I Ill AS117lNYKS 1 1SlIMP T?-! j� Nv5 /may/- / /� � / INV, 6.63' ,..--- B - f ID C, 1 1 5 INV 5 60 PIPE RACK (REF) TRENCH CONSISTING OF PRECAST CONCRETE UNITS INV. 11.46' INV. 11.18' PIPE RACK (REF) C.B. INV. 6.17' T.O.G. 9.00 MONOLITHIC CONC. TRENCH YFNIFY OLD 18` (_MP NORTH Of C.B WAS REMOVE/) MN #ELL) a + M w TO SUMP •- FUEL OIL DAY TAN M. - 10.7' AT CO-3 iv 16.3' AT WELL CIW-7 // 4" HDPE INJECTION WELL HEADER PIPE EXISTING GROUND SURFACE / 2-43"x27" CMP ARCHES INV. 5.6' AT CO-3 INV. 5.4' AT WELL CIW-7 EXIST 8' AW2-71788 6" MIN. CLEARANCE BETWEEN CMP AND HDPE HEADER PIPE SECTION A -A SCALE: 1 /4'=1'-0' ,INV. 12.73' -1- PIPE RACK !REF) -10. TF-100 12 7' -- SPZ-10 - 8' Ali? 7' l&5 M.H TOP 10,6 INN 7 7' Ij`"-;- M.M. 11 TOP 12.0' INV. 5.35' II INV. 6.50' 12" CMP C.B. INV. 6.75' T.O.G. 9.20' 2-43727' CMP ARCH M.H. TOP 11.5' INV. 523' + BUILDING J CA 2 w w LL ELEVATION 12 8 4 0 N 88+00 N 86+00 N 84+00 N 82+00 OO+I£4 3 CLEAN ACID FACILITIES SITE DRAINAGE AND UNDERGROUND PIPING PLAN, DRAWING CE-00008, REV. 9. SPA TANK FARM EXISTING AND PROPOSED TANK LOCATIONS,DRAWING DOG-071-047, REV. 2. SUPERPHOSPHORIC ACID AREA AND BLEND TANKS PLOT PLAN, DRAWING DOG-080-007B, REV. B. DAP BLEND AND 54%P205 TANK AREA GRADING, PAVING AND UNDERGROUND PLAN, SHEET NO. 1, DRAWING DOG-071-040A, REV. A. DAP BLEND AND 54%P205 TANK AREA GRADING, PAVING AND UNDERGROUND PLAN, SHEET NO. 2, DRAWING DOG-071-043. H2SO4 AND PETRO AG TANK AREA GRADING, DRAINAGE AND PROCESS SEWAGE PLAN, SECTIONS AND DETAILS, DRAWING DOG-071-044A, REV. A. PLUMBING - AREA 60, SANITARY SEWER - PHASE II, PLAN & PROFILE, DRAWING DPL-060-002 REFERENCE DRAWINGS AND KEY PLAN 0 75 150 SCALE- 1"=150' r12 18' A.C.P. @ 1.27% N 8' SOUTH OF HEADER PIPE CONCRETE TRENCH INV.8.0' �\ FIELD VERIFY EL OF 18' AND 36" PIPES AT CROSSING E 128+48.75 36" A.C.P. INV. 4.5' -- E128+73.5 18" A.C.P. INV. 6.5' E 129+45 -. 6" C.V. INV. 7.7' - E 128+95 4" C.LP. INV. 4.0' FIELD CHECK FOR PIPE AT E 129+621 4' HDPE INJECTION WELL HEADER PIPE INV. 4.8' 2 w E130+M 30" PIP! INV. al' 8 CO N_ W 8 Ri W 8 8 W PROFILE ALONG INJECTION WELL HEADER PIPE FROM CIW-1 TO CIW=4 HORIZONTAL SCALE: 1'=40' VERTICAL SCALE: 1'=4' 3 8/6/91 ADD AS-SUILT WITHDRAWAL WELL AND PIEZOMETER LOCATIONS 2 6/18/91 ADD SECTION A -A. PROFILE, AND PIPELINES RELOCATE SUPPLY TANK, AND ADJUST HEADER PIPE AUGNMENT 1 4/15/91 ISSUED FOR CONSTRUCTION, REVISE CUT-OFF WALL AUGNMENT AND WITHDRAWAL WELL LOCATIONS, ADD EXISTING SEWER UNE AND REFERENCE DRAWING 7 0 10/17/90 ISSUED FOR BIDS LAYOUT OF TANK FARM REMEDIAL ACTION SYSTEM Ardaman & Associates, Inc. Consulting Engineers in Soils, Hydrogeology, Foundations, and Materials Testing TANK FARM REMEDIAL ACTION PLAN Texasgulf inc elf aquitaine group P1 7/31/90 ISSUED FOR DEM REVIEW REVISION DATE 'DESCRIPTION APPR'D BY ENGINEERING JOB NO.: AFE-N-763 DRAWING NO.: 2 DRAWN BY: KJS CHECKED BY:' DATE: 7-9-90 • FILE NO. 88-089 APPROVED BY: