Loading...
HomeMy WebLinkAboutWQ0042568_Application (FTSE)_20210524State of North Carolina Department of Environmental Quality Division of Water Resources D__WR 15A NCAC 02T .0300 FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04.16 & SUPPORTING DOCUMENTATION Application Number: W f## Z Q do be compIctcd by DwR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: Johnston_ County Public Utilities (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® State/County ® Municipal ❑ Other 3. Signature authority's name: Chandra Cox Farmer per 15A NCAC 02T .0106Jb] Title: Director 4. Applicant's mailing address: P.O. Box 2263 z City: Smithfield State: NC Zip: 27577- n 0 5. Applicant's contact information: Phone number: (919) 989-5075 Email Address: chandra. farm erO, iohnston nc.com70 0. �° y Ii. PROJECT INFORMATION: I. Project name: Hardees at Cleveland and Cornwallis Road 1 O IV 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project O o i � If a modification, provide the existing permit number: WQ00 and issued date: p If new construction but part of a master plan, provide the existing permit number: WQ00 w 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.5804" Longitude:-78.542586° 5. Parcel ID (if applicable). 163600-67-6157 (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: 1. Professional Engineer: J. Michael Stocks License Number: 19843 Firm: Stocks Engineering P.A. Mailing address: PO Box 1108 City: Nashville State: NC Zip: 27856- Phone number: 252) 459-8196 Email Address: mstocks cr,stocksenpineerinQ.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I . Facility Name: Central Johnston County Regional WWTF Permit Number: NCO030716 Owner Name: Johnston County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ 15579 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00060 Owner Name(s): Johnston County FORM: FTA 04-16 Page l of 5 V1. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [:]No ®N!A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached`' ❑ Yes ❑No ®N.'A 3. If the Applicant is a HomeiProperty Owners' Association, has an Operational Agreement (FORM: HOA} been attached? ❑ Yes ❑No ®NiA 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel andlor Motels ❑ School f preschool l day care ❑ Medical J dental ! veterinary facilities ❑ Swimming Pool lClubhouse ® Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses/ offices l factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : �__% Domestic,'Commercial 100 % Commercial Industrial (See 15A NCAC 02T .0103(20)) 4Is there a Pretreatment Program in effect? ❑ Yes [:]No 6. Has a flow reduction been approved under 15A NCAC 02T .01 14( ? ❑ Yes ® No ➢ If yes, provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 021.0114(t1) Daily Design Flow a.b No. of Units Flow 0 gall -- 0 GPD gall GPD gall GPD gall GPD gall GPD gall GPD Total 0 GPD a See 15A NCAC 02T._0114Li 101 (e)(1) and (eX2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02101141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A N�'AC 02T .01 14) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ® Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ® Other (Explain): This. is a public line that ari_vate system currently beingpernitted will pump into FORM: FTA 04-16 Page 2 of 5 N VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers)- 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material N/A ➢ Section 11 & III of the MDC for Permitting of Gravity Sewers contains infonmation related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): /A COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT Pump station number or name: Approximate Coordinates (Decimal Degrees): Latitude: Longitude: Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at _ 5. Summarize the force main to be permitted (for this Pump Station): feet total dynamic head (TDH) Size (inches) Length (feet) Material 2 1,230 C-900 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305 l ): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)- ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04- l6 Page 3 of 5 IX. SETBACKS & SEPARATIONS (02B .0200 & 15A NCAC 02T .0305(t)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305 f f) &..W ➢ 15A NCAC 02T.0305 t contains minimum separations that shall be provided for sewer Is stems: ® Yes []No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including -in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet 100 feet **Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class 11 impounded reservoirs used as a source of drinking water **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet 36 inches Final earth rude vertical ➢ 15A NC C 02T.0305f ) contains alternatives where separations in 02T.0305(fw cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surfage Water Classifications wgbpAge ➢ If noncompliance with 02T.0305(f) or f gI. see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC: 02B .0200? ® Yes ❑ No ➢ This would include Trout Buffered Streams per ISA_N(AC B.02 2 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 1.5A NCAC 02T.01Sc)[6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC. 02T.0105(c)(b), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 1.5A NQAC 02T, the inimum Design Cri is for the Perms Station and Force Mains (latest version) and the gravity Sewer Minimum D iiLn Criteria flatest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is re wired prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: 1, _ Itl<< G�1aFi� S�OG�LS attest that this application for (Professional Engineer's name from Application Item 11I.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T M (Signature Authority's .0106( . Glrac.� �2 1):1 & title from Application Item I.3.) attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6I.i, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: FORM: FTA 04-16 Page 5 of 5 Divklon of Water lie%ourc r,. State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Johnston County Project Name for which flow is being requested: Hardees at Cleveland & Cornwallis More than one FTSE play be rerluired fora single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed lvasteivater floip. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Central Johnston County Regional WW Facility b. WWTP Facility Permit #: NC 030716 Alf flows are in MGD c. WWTP facility's permitted flow 9.5 d. Estimated obligated flow not yet tributary to the WWTP 2.002 e. WWTP facility's actual avg. flow 7.091 f. Total flow for this specific request 0.0008 g. Total actual and obligated flows to the facility 9.0935 h. Percent of permitted flow used 74.6 actual/95.7 paper II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily How** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Josephine D r1 28867Mod 3.384 1.3536 0.7524 0.4082 1.1607 0.1929 Landfill 20340 1.9296 1.6718 0.92819 0.6368 1.5650 0.1069 The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Weston Woods Downstream Permit Number: WQ0015579 Page 1 of 6 FTSE 10-18 III, Certification Statement: I Chandra C. Farmer, P.E. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which 1 am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Signature Title of Signing Official Page 2 of 6 FTSE 10-18 Sewer Project Narrative For Cleveland and Cornwallis Road Hardee's The private sewer pump station to serve the Hardee's at Cleveland and Cornwallis Rd. is located on the on the 1.4 Ac. (Leased Lot Acreage) parcel owned by Boddie-Noell Enterprises, Inc. The sewer pump station will only serve the restaurant on the parcel. The flow was calculated using the NCAC 02T daily flow of 20 gal.'seat for restaurant with single service articles. Since the restaurant will have 40 seats, the daily flow for the project will be 800 GPD. It will consist of 1000}0' commercial flow. The force main in the public right-of-way will consist of approximately 1,230 LF of 2-inch C-900 PVC that connects to an existing gravity manhole. The force main in the right of way is permitted by Johnston County Public Utilities. The private lift station and force main located outside the public right-of-way will be permitted separately by Boddie-Noell Enterprises. The wastewater treatment plant facility that will be handling this flow is the Central Johnston County Regional W WTF (Permit # NC 0030716). 'V( I-)rAr of F.t?VI r 67 �h k°gional O frice jk, t� W�4 40 s40 Ak Q Qd N e aI 0*"Tw81Nn Ad State of North Carolina Department of Environmental Quality Division of Water Resources D1_ 15A NCAC 02T .0300 -FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of ,S NCAC J and the Division's Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with, IM NCAC 02T, 15A NCAC 02T .0300, Division policies and good engineering practices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .b305 and the applicable minimum design criteria. These documents shall be available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAa"u. rp Projects not eligible for review via the fast track process (must be submitted for full technical review): r°FF ➢ Projects that require an environmental assessment in accordance with 15A NCAC IC .0100; nt'�ro ➢ Projects that do not meet any part of the minimum design criteria (MDC) document; ➢ Projects that involve a variance from the requirements of 15A NCAC 2T; ➢ Pressure sewer systems utilizing septic tank -effluent pumps (STEPS) or simplex grinder pure ' 0 ? pU$i ➢ STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); ����e 09?1 ➢ Vacuum sewer systems. General When submitting an application, please use the following instructions as a checklist in order to ensure all requiritems are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy of Application and Supporting Documents ® Required unless otherwise noted B. Cover Letter (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. ➢ Be specific as to the system type, number of homes served, flow allocation required, etc. ➢ If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Major Modification Application Packages): ® Submit a check or money order in the amount of S480.00 dated within 90 days of application submittal. ➢ Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages): ® Submit the completed and appropriately executed application. ➢ If necessary for clarity or due to space restrictions, attachments to the application may be made. ® If the Applicant Type in Item 1.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. ❑ If the Applicant Type in Item 1.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item II.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc. ® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina. licensed Professional En inter. ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page I of E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. ➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. ➢ The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. ➢ Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 215.67(a). ➢ Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x 1 1-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area and closest surface waters. ➢ Location of the project (gravity sewer, pump stations & force main) ➢ Downstream connection points and permit number (if known) for the receiving sewer ® Include a street level map showing general project area. G. Existing Permit (All Modification Packages): ❑ Submit the most recently issued existing permit. ❑ Provide a list of any items within the permit the Applicant would like the Division to address during the permit modification (i.e., permit description, flow allocation, treatment facility, etc.). H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per 15A. NCAC.02T .0305(h)(1), submit documentation of power reliability for pumping stations. ➢ This alternative is only available for average daily flows less than 15,000 gallons per day ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) 1. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per 15A NCAC 02T .0115(a)LIJ provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Home/Property Owners' Associations ❑ Per 15A NCAC 02T .01 15(c), submit the properly executed Operational Agreement FORM: HOAR. ❑ Per 15A NCAC 02T .01 15(c), submit a copy of the Articles of Incorporation, Declarations and lay -laws. ❑ Developers of lots to be sold ❑ Per 15A NCAC 02T .01 15(b), submit the properly executed Operational Agreement (FORM: DEV). For more information, visit the Division's collection systems wehsite INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3