HomeMy WebLinkAboutNC0069761_202104VRR_20210622DMR REVIEW RECORD Winston-Salem Regional Office Facility Name: Pond Creek WWTP Permit Number: NC0069761 Report Period: April 2021 Prior Assessments: Enforcement Factor: Waterbody Outfall # Outfall Description Waterbody Name Classification 001 Effluent to Pond Creek Pond Creek C;Tr Monthly Average Limit Violations Sample Location: Outfall 001 - Effluent Violation Unit of Limit Calculated % Over Date Parameter Frequency Measure Value Value Limit Action 4/30/2021 Nitrogen, Ammonia Total (as N) - 2 X month mg/I 2.60 4.50 71.7 Concentration Monitoring Frequency Violations Sample Location: Outfall 001 - Downstream Violation Unit of Date Parameter Frequency Measure Action 4/3/2021 Oxygen, Dissolved (DO) Sample Location: Outfall 001 - Upstream Weekly mg/I Violation Unit of Date Parameter Frequency Measure Action 4/3/2021 Oxygen, Dissolved (DO) Weekly mg/I Other Violations/Staff Remarks: Regarding DO for Upstream and Downstream, since the first week in April was a split week with March, I checked March's DMR and found there was no parameter on DMR for DO (U&D) to be reported. However, the permit states DO for (U&D) is to be done throughout the year and Effluent DO is only between April — October. Talked with ORC and he stated they have tried to add the parameter onto eDMR, but no success. He has Togs where all DO readings (Eff/U/D) are recorded and kept, and that the DO reading was taken earlier in the week (at end of March), but had nowhere to record them on DMR. Regarding NH3, he has had issues with clarifiers and pipes being clogged at clarifiers. We spoke on phone in detail, and he believes during the wasting and cleaning of clarifiers was the cause in elevated NH3 readings. He marked the DMR compliant, and I instructed him to revise and resubmit the DMR to mark `non -compliant' and place issue with clarifiers in the comments section of DMR. He said he would correct within a week and resubmit. I will follow up on 6/29/21 to make sure it was done. Historically, violations have occurred within 12 months concerning same parameters (DO freq/NH3 exceeding limits) — which resulted in a NOD for DO and NOV for NH3 (see below). However, the DO violation involved the Effluent and not U&D. Violations were also detected during inspection. **Follow up 6/25/2021: ORC has revised and resubmitted DMR to reflect `non -compliant' for NH3. The comments added were: "NH3 was high due to daffier skimmer stopped working. it is now back on line. NH3 is down and doing good" Recommend NOI Supervisor Remarks: Jenny — NOI Completed by: Tricia Lowery Date: 6/25/2021 Assistant Regional Supervisor Sign -off: Jenny Graznak Date: 7/2/2021 Regional Supervisor Sign -off: Date: Prior 12-Month Enforcement History Permit Number: NC0069761 Report Period: April 2021 Limit Violation Sample Location: Outfall 001 - Effluent Violation Report Violation Date Period Parameter Type NOD NOV CPA 10/31/2020 10-2020 Nitrogen, Ammonia Total (as Monthly Average N) - Concentration Exceeded NOV-2021-LV-0175 Monitoring Violation Sample Location: Outfall 001 - Effluent Violation Report Violation Date Period Parameter Type NOD NOV CPA 4/4/2020 4-2020 Oxygen, Dissolved (DO) Frequency Violation NOD-2020-MV-0092 Other Violation Violation Report Violation Date Period Parameter Type NOD NOV CPA 8/14/2020 Violation detected during inspection NOV-2020-PC-0414 8/14/2020 Violation detected during inspection NOV-2020-PC-0414 8/14/2020 Violation detected during inspection NOV-2020-PC-0414