Loading...
HomeMy WebLinkAboutWQ0042529_Application (FTSE)_20210527Central Files. APS _ SWP 5/18/2021 Permit Number WQ0042529 Permit Tracking Slip Program Categery status Project Type Non -discharge In review New Project Permit Type Version Permit Claasiflca#ion Gravity Sewer Extension. Pump Stations. & Pressure Sewer Extensions A Individual Primary Reviewer tyler benson Coastal SWRule Permitted Flow Facility Permit Contact Affiliation Facility Name Major(Minor Region Seaside Palms lUtrR W Wilmington County Location Address I3ru ngwiGC Facility ContactAtiiliation Owner owner Name Owner Type Brunswick County Gavemment - Cour:y Owner Affiliation John Nichols PE PO Box 249 DateslEvents Bolivia NC 2842202- Scheduied prig Issue App Received Draft initiated Issuance Public Notice Issue Effective Expiration 5l12)2021 Regulated Activities Requested !Received Events Additional information requested Additional information received State of North Carolina Department of Environmental (duality DWR Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-I6 & SUPPORTING DOCUMENTATION Application Number: 07 (lo he anmpmcd by DWR) All items must N cam letcd or the anplicalion will he returned 1. APPLICANT INFORMATION; 1. Applicant's name: Brunswick Co1W (company. municipality. HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® Stawcounry ❑ Municipal ❑ Cnher 3. Signature authority's name: William Pinnix P.E.per I5A N C,AC 02 ]0 Title: Director of I;ngiiering 4. Applicant's mailing address: P_O. Box 2 City: BgLivia State: NC Zip: 28• 422•` 5. Applicant's contact information: Phone number: 4( l0} M-2+()l Email Address: williain pinnix(a)brunswickc n nc.gav IL PROJECT INFORMATION: 1. Project name: Seaside Palms 2_ Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification. provide the existing permit number: WQW and issued date: If new construction but part of a master plan. provide the existing permit number: WQ0t3 3. County where project is located: Bar nswick 4. Approximate Coordinates (Decimal Degrees). Latitude: 33_ 9381° Longitude:-78.5018' 5. Parcel ID (if applicable): 21100037 (or Parcel ID to closest downstream sewer) 1fi. CONSULTANT INFORMATION: 1. Professional Engineer: Josevh K. Bland PRE License Number: 041620 Firm: Norris Tun tall C nsultin En ineers P. Mailing address: 1429 Ash -Little River Road City: �h State: N—Q Zip; 28420 Phone number: 914 M-5900 Email Address: 'bl d ten ineers,com IV. WASTEWATER TREATMENT FACILITY (WWTF)INFORMATION: 1. Facility Name: Sea Trail Permit dumber: WQ 001274i3 Owner Name: Brunswick Court V. RECEIVING DOWNSTREAM SEWER INFORMATION or different than WWTF): 1. Permit Nurnber(s): WQ 003 2250 Downstream (Receiving) Sewer Size: 9 inch systom Wide a31 Ilion stem Perini Tlumber s if a icable : WQCS002$4 owner Narne(s): Brtl swat ick County FORM: FTA 04-I6 Page I of 5 V1. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate or Public Convenience and Necessity been attached? ❑ Yes ONO ®NIA 2. If the Applicant is a Developer of lots lobe sold, has a I3cvcdper's rational AQrecment i QRM: PE—V_l been attached? [:]Yes ❑No ®NIA 3. If the Applicant is a Itome/Properly Association, C�$ralionAl Agrccment.fl:URM: HOAl been attached? ❑ Yes ❑No ®NIA 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motcls ❑ School / preschool I day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Mature of wastewater : I_Q0 % DomeslWCommercial °Io Commercial % industrial (See 1 AA NCAC 02T _ 103 20)) 0—r~Is there a Pretreatment Program in effect? ❑ Yes ❑ No fi. Hasa flow reduction been approved under 15A_NCAC 02T-0114( ? (DYes ❑ No a If yes, provide a ropy of flow reduction arproval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.01 14(f) Daily Design Flo►v''b No. aI units t 3-bedroom residential 210 gal/unit l04 2 gal/ gal/ gal/ GPD gab GPD gal/ GPD Tot,! 21,840 GPD a See 15A NCAC 021- -01 14 d e ] d (e)2 for caveats to wastewater design flow rates {i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east ofthe Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table I5A N 'AC C i13TA 1 l41 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. S. Wastewater generated by project: 21 84 GPD (per I S NCA 2T . 4 ;�- Do not include future flows or previously permitted allocations if permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain)_ Page 2 of 5 FORA4; FTA 04-16 Vil. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 2U T A305 & ,MDC Gravit S wers : 1. Summarize gravity sewer to be permitted: Sire (inches) Length (feet) Material 8 3,533 PVC 8 30 DIP 9 Section 11 & Ill of the MDC for Permitting of Gravity Sewers contains information related to design criteria )0- Section][] contains information related to minimum slopes for gravity sewer(s) > Oversixing lines to meet minimum slope requirement is not allowed and a violation of the MDC VII1. PUMP STATION DESI ;I4 CRITERIA (If Applicable) — 02T ,D OS & LNIDC j Pum 5tationslForce Mains COMPLETE FOR EACH PUMP STATION INCLEIDED IN THIS PROJECT 1. Pump station number or name: Se ide Palms Pump Station 2, Approximate Coordinates (Decimal Degrees): Latitude: 33.938I' Longitude: -78.50 ° 3. Design flow of the pump station: 0.02184 millions gallons per day (finn capacity) 4. Operational point(s) of the pump(s): $62 gallons per minute at l �2 feet total dynamic head (T€)H) 5. Summarize the force main to be permitted (For this Pump Station): size (incites) Length (feet) Material 4 40 PVC 6, Power reliability in accordance with 15A NCAC 02T .0305 h [ : ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(I XB): Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day �- Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry- 15A NCAC 02T .0305 (h)( 1)(C ) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - ISA NCAC 02T .0305(h)(I)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ;e if the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM; FTA 04-1 b Page 3 of 5 M SETBACKS & SEPARATIONS — (0213,0200 & 15A NCAC 02T.0305(f)): L Does the project comply with all separations found in f 5A NCAC 02T 4305(DA-W ® Yes ❑ No g 1A NCAC 02T.03U5 contains alternatives where separations in 42T.034 cannot be achmevea_ ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webo3L'e Y If noncompliance with QTA3 &f) nr (2), see Section X o€this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ NIA 9 Seethe Division's draft separation requirements for situations where separation cannot be meet 9 No variance is required if the alternative design criteria specified is utilized in design and construction Y As built documents should reference Elie location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02 B .D3 ? ❑ Yes ❑ No 9D Nti A A This would include Trout Buffered Streams per 15A CA 0202 4. Does the project require coverage/aothorizat ion under a 404 Nationwide or ❑ Yes No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 4_0 & Bnffer ertnitting Branch 5. Does project comply with l A N 7AC 02T. 105 c 6) [additional permiWcertificationsr Yes © No Per 15A NCAC 02T.010 c b ,directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6_ Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the server. ❑ Yes ® No ❑ NIA r If yes, include an attachment with details for each line. including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. Page 4 of 5 FORM: iFTA 04-16 7L CERTIFICATIONS: 1. Does the submitted system comply with 1 SA NfAC 0 _1 the Minimtun 2saign Criteria for Ihe_P�r_m_itting of Pump Stations and Force Mains latestyerri�x-1 and the 91 i M'r imu `teri la e v r iQnj as applicable? ® Yes 0 No If No. complete and submit the Varlancc!Altemative Design Request application (VADC 10-14) and supporting documents for review. Aimiroval ofthc request is required prior to subml tat of the Fast k AIDDlicAtion and svpporting documents. Professional Engineer's Certification: 1.i� _ __.attest that this application for tProfessional I:ngincer's naictme from A iication Item 111.1.} has been reviewed by me and is accurate complete and cons'stent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. l further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers {latest version), and the Minimum design 0iteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest vcrsion). Although other professionals may have developed certain portions of this submittal package, ineltsion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B. any person who knowingly makes any false statement. representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10.000, as well as civil penalties up to $25,000 per violation. North Carolina. Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0105(b): AR '4 SSr A�.,Q` J v 4NGit4�EPK K. that this application for (Signature Authority"§ n & title from Application Item I.3.) SeAs,Ae. ct tr"5 has been reviewed by me and is accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included this application package is subject to being returned as incomplete. l understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit he violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.GA and i43-215.013, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed 510.000 as well as civil penalties up to $25,000 per violation. Signature: - _ Date: Laozj FORM: FTA 04-16 Page 5 oft RECEIVED SEWER NARRATWE MAY 10 2021 SEASIDE PALMS NC PS Brunswick County, Sunset Beach, NC For RHH Land Investors, LLC 2919 8reeaewood Ave. Suite ZOO Fayetteville, NC 28303 910-486-4864 April 2021 Prepared by: NORRIS & TUN5TALL CONSULTING ENGINEERS, P.C. 1429- Ash — Little River Road Ash, North Carolina 28420 (910) 287-5900 (910) 287-5902 (Fax) License # C-3641 N&T Project No. 20164 NARRATIVE SEWER SYSTEM: This private gravity system is designed to service a 104-unit 3-bedroom single family residential subdivision with a total flow of 21,840 GFD- A total of 3,563 LF of fl- inch sewer line will be needed to complete the system. This new system will discharge into a proposed pump station located on -site. 49 LF of proposed 4" SSFM will run from the pump station and connect into an existing 8" forcemain on NC 904. This system will be served by Brunswick County Public Utilities. RECEIVED mAy 1 j 2CZ1 � l P1S av, PO BOX 249COUNTY QF BRUNSWICK BOLIVIA, NC 28422 BUILDING r ENG[NEERiNG SERVICES(910) 253-2500 Of ice IAd1' t2 N21 (910) 253-2704 FAX �rGi]EG April 23, 2021 Mr. Joseph K Bland. P E. !Norris & Tunstall Consulting Engineers, P.C. 1429 Ash -Little fiver Road Ash. NC 28420 Re: Seaside Palms Dear Mr. Bland: our office has reviewed the proposed plans and specifications for the new sewer extension and pump station and has determined that this project will meet Brunswick County's minimum standards and specifications if the project is constructed as designed. Brunswick County has a sufficient treatment capacity to provide sewer service for this project. This letter hereby grants authorization for the plan submittal to the North Carolina Department of Environment and Natural Resources for review and approval Your signed permit appiication is enclosed. Please send a COPY of this letter to the State along with your plans, specifications and permit application. Please do not hesitate to contact our office if you have any questions. x,4� *Nxl Sincerely. x Amy K. Aycock Project Manager RQ W ,cF%\ J ED State of forth Carolina Department of Environmental Quality DW ., , 0 ?,I- ) Division of Water Resources fl1,61slon of WAtrr Re•u„ � j �j Flow Tracking for Sewer Extension Applications KTa f }M (I I sl,: 1[1-[8) Entity Requesting Allocation: Brunswick County Public Utilities Project Name for which flow is being requested: Seaside Palms Subdivision More shan one FTSE may he requiredfir a .single project ff ilie owner of the Will'TP is not responsfhle for fill priinp xtodons along the rordte e f the propi;wd wa.stewarer flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: SEA TRAIL ww,rF b. WWTP Facility Permit #: _WQ 0012748 Al{,flaws are in MGD c. WWTP facility's permitted slow 0.300 d. Estimated obligated flow not yet tributary to the WWTP 0.8092 e. WWTP facility's actual avg. flow 0.201 f. Total flow for this specific request O-02 E 84 g. Total actual and obligated flows to the facility 1.032 h. Percent of permitted flow used 344.01% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (13) (C) (D)-(B+C) (E)-(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow" Current Tributary Flow Plus (Name or PcRuil Capacity. ' (Firm ! pf7, Avg. Daily Daily Flaw. Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of set -vice. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum ❑esign Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is { o. Downstream Facility Name (Sewer): Mcdonalds Force Main 8" Downstream Permit Number. W 0032250 Page 1 of 6 FT5E 10-18 III. Cettif:ication Statement, I William L. Pinni`� certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station ca route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the hest available data. This certification applies to those items listed above in Sections I and 11 plus all attached planning assessment addendums for which i am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. —� -k IL ., -- �- . Y �,- L� �Z�s 1 Signing Official Signature >1 atle- a Title of,Signing Ojfcial Page 2 of 6 FTSE 10-18 i 56'17.2"N 7-8 30 UO 5 "" - Goo& Maps Google Maps 33*56'17.2"N 78°3U'U&5V https:Jlwww.geogle.com)maps/place/33'5617.2''N+78"30'065"WiL33.93$1; 79.503988— Hyency. MiNP Uara C2U21 20U ft I I'l 511 W2421, 2:54 PM Brunswick County Wastewater Pump Station Force Main Design Calculations Project Name: Seaside Palms Location: NC 904 Designed By: US Checked By: !KB Date: V912021 Projcet 110,: NT#20154 Brunswick County Wastewater Pump Station Force Main Project Summary Project Name: Seaside Palms Average Daily Flow (gpm): 21,840 Pump operational Point No. i (gpm@tdh): 86.2 gpm Q 97 tdh Pump operational Point, No. 2 (gpmQtdh). 86.2 gpm @ 24 tdh Pump manufacturer_ Flygt Model Number: NP 3127 lmpelter Diameter: 14G mm Horse Power: l l hp Voltage: 460 V Force Main Diameter (in): 4 force Main length (ft): 40 Tributary Wastewater Flow Calculations 1:stnhltrhmrnt 11n11 Vrslat Ualt lyre N gjlllefra Ifhcbargr, Clm Ga nit `ZceidenlYal oNEWVrrF) 360 _ Resrderce ° - U lze5dentn1SillmhorTrcbbmntFacilMcss __ 210 Residcnce 104 1NoN - BorUcrShaEs_ — - S°PASU ° ShOp - 125 ROCO or liowi , 0.___ tl n oirtss-GeTwal&4ffioe _ 23 �°YcePrr stall ° ° ©wirress. Factories Cxcludmg lndtrstrial Wade 2S Empl°�Se De►shilt 0 - - - - 9usiness or Fptiorics m'showessgr Todd prepetaliwn _ 33 t mph ship° - Business-WarehOrr_C 106 l,0adina6y Q �- BlydrICS3 - Warcilausd Sol F31M7$G {pot inCludln Camaket Rsaidenee} 1 Unit - - ' ° Church" uilhgut kisohenA day ars, OF esmps_ _ 3 -�— Sea - °- - 0 ° ChuTch" wRh itilchatrs 2S Pki'san (ddld+ aye@) ° 9. Churches�dgttidill� da cator comp 0 � -ire orRrse me widruml on silo sla ff �-- - - 2S - FIcnim 0 A At d< Rexue with on -slew staff �- ;0 Pusgrr pa shift 0 U ]0 •ond � Drink • 9angrrc! ihniaSHnll _ � Seat - - � ° 0 vvd & Drink . grrs Codrtail i anagCx _ _ 26 = Sat ° 0 50 1°Osflloat�- Food & Drink - CWOM - Saal 0 0 . ood & Dmvk - Restaurants. lirtl Service {q 0 0 20 IXink • Restaurants, Smglrr Smkz Artidcz _ - Sea - Fond A DnA dReReslaurasts, Dnw-in 50 ° q Foot] & DNnlr • R"urams, CwTyrsul only Food R. Orrok - Indtilutieaa, Dining I talk � - -�-- meal - - ° ° Food& Drina- Deli lq°- Food & Drink - _4jhLnY° 75 1Dog Food dt ikin7r- Mest Dept, q=mr._Fish MOW _ v ° Foal d Dr n� k��ccialtY Food Slertd of Kloslt SO 1gosFtlaarspaca __ _ 6 4 Hgtclsll+dotelsrBRB withwd in-rnara Doan ktrR T�cflilies 124 - - Ragm- . ° ° HotcLci�fatels!6&L3 with in-raarn eantra�iacrlrites .� - 175 Raa rn ° 2m p HgtclsrMotcls- Rrsort Hotels_ . - _ Umr U ° Hotc!VNsq!ds-Conagcs,COWS _ 200 5Q0 Machine .�.. J D 0 I.aundrins Sc[ ICSirvix�_ Bs° 13agtilioner l#7 Skill 0 q Medical or DantW offices_ _ _� 250 Pmcnti er shin 0 _ --- Medical - V Cliscsm 11'ilbgYt boardinC _ - - - 2t] mqi Pea. Cie, Kennel, Sal l Medical - Vrxarinary. Kamth WA b-ANL_ --- ° 0 300 W Medical -Medical IkSjN als _ _. Mcdyral . Mental Hospitals _- - — - EM ° 0 Medical - Conwlesccnt, Nursin , R- Hasrre - ftul �. - 60 - - - ° Medipt - Cgnnlrsanl, Nu =t18 RCH Humes wf Gundr l28 - Ba 4 O Medipl-l;esidentialCataFacilitirs _� . 6P Person - 0 0 Parks & R-_ ends tvlcgmf*A sradon but wilhprl wa1M drsewerlreel a 75 !aa!Pu� ° Fatly R Rec. •Cam ods with scaler � semr hookuV 1O° Cam�stto 0 ° ° Parks & Roc-Camryground PumQSW on ficali�t _ - Parks R Rec -CanstrvctiotL Hunt ing. or Walk camps with 11wh loi kls � - Pcrson- - 0 Perks Rw. • Crrnstrudran Hunting a Work camps with chemical gi porlabla 1 40 Person a 4 rq umfiin$Fyx[use 4 Parks & Roc. -parks with Restmoms - _ 0 Parks R Rec - Summer calm IFtout &wd�gi Iwndr�faeililale5 '� _ Perrort - 0 Ptlrksl�l?a--Sumtnercam�witttfggd�repandleandry_saaulit�cs _ 60 � ° ° Parks d Rae--Saimming_Pgals. Bmh Houses. Spas_ 10 Person F ° ° - 0 yxS P]umhin Fixture Puhlic Access Rrslraams c_/ Tributary Wastewater Flaw Calculations Fstohltshrnenl Unit Value GaV J[lnh limit Type iehools.- Presch*Ms �k DGIVN s z.$_ _ Persor (chlld-emphnyee) _ ichoois with Cafe[pi � tip. t4 ShOutrs _ _ IS Studcm "Ools With 478fatet3a 12 - SludeM ichoolswilhoulCoft4irio,G)M%&Shown— _ �_ Studrtrt ichools,Bvatding­__ —. Person(xludent-emplo)rc} ke ce Stu11411S. Gas Sgions 250 Plumbing Fiscurr ytr Wash 6ecilWes (if recycling water, see Ruk -022S 2f2TMhdideyk_ 1240 Day— ipotis CcnlHs • a05rimg fa —� taw. — ipom Cenitvs - FertasFjtercisc, [Camh, Dartce _ 50 _ 100!<fnoor pace — iPMU cenlets - Tunis, itapgatt bell .5.0— !Purm.Centers -Oymmasirm _ _. 'Jp 100eflicar»a — S�aetsiLn*rs-Gdremtstwithotdyminim ffeodwrAm_ ISa PhsTb Fixntrr i�otlsGbWm-Country Clubs 61) MemberatPNfon Ceatws _Mini Golf, Putt�Pltll _ 4.50 PlumbirS Fixture Ceettm G"aA- Alotgrctuas 75i1 PWMNng Fixlurc ipo-q-ters-WiLhgCagM POvingRangim 250 PlambingFimute jpws Crntern - Marrs wifham Owbhouse 10_ —SIB ioorn Ccntcrs - Mari nas wilh Baehhausc _ 3li Slip ipotts CcRWn_ Video GamC ArcadeS, Pool Has 250 Plumbing FaMm _ 5 Sest _ sladlulns. Audnonums, ThcatfcY` CammamtYCcaura SYor i, FJioppenr Centers. Mal. & 1.7en "-1,"f_ , Auto, Heal, RV.4nk%kiWstlovrrootris with resttootm Curluenicnee Stores. with Food Ptepanwan - Caotrtrlience SmeeS wahwl Food PreMandm - Fka lrhrkees . Sing CtL—and IYWIs -1h Food Scr— �. Stora4 uld 5ho��CCullers withatt Ftwd Ssfvite fewr�rogioriTetmivals-_Air,Bue.TMn�FC",PoltAdoCk llher- Other - From ISA NCAC 02T .Ol lA 125 Plumbing Future d0 li]Osfnaarapacc 250 Piumhing Fixture �p shalt 130 lowif 100 i000sf Average Daily Flaw Disc&nrRc, GPI) 0 X of Ira IO 0 C a 0 0 Cycle Time & Wet Well Geometry Target Cycles Per Flour ADF 15 gpm Pumping Rate = 80 gpm Time = 15.0 min. Cycles Per Hour = 4.0 Check C),cles Per Hour. OX Check Cycles Per Hour: OK Determine Wet well Diameter Required Volume= Pick Wet Well Diameter = Pick Wet Well Cycle = Volume in Cycle = 184 Gallons Ft Vert. Ft Gallons 8.0 0.5 188 Vertical Datum Used: NAVI) 88 Determine Wet Well Invert & Float Elevations Wet well Dia. &0 Ft Tap Elev= 44.50 I Gnd Elev= 44.00 S5 invert In-- 1 29.70 m = 27.70 On � 26.70 1 On = 25.70 lus Off 25.20 Bottom Invert Blev*=121.20 *As required for complete submergence ❑ I{ 2 Farce Main & Piping Design off -site Force Main Data Design Pump Rate (gpm) - 80 Seleet Force Main Size (in) T d Velocity (fps) = 2.04 Meets Mininirrrat Velocity Requirement? OK geets Maxi"itrm Veloclly Requirement? OK Required Pomp? T1cc Nrm-Ciog l'iim Line L englh (ft) =l 40 Account for Minor Losses = 5% uiv Length (ft) _ 42 Connection Poigt: 2d" Force Main @3a North Brunswick WW'TP Pump Selection Force Main Diameler (in)- 4 Lquivalent Force Main Length (ft) - lie Hazen -Williams C Factor - 130 Minitntzm Required f limp Rate (CTM) + 39 Oesign Pumping Rote KTM) 9D hrrsstlrc Ft4ad 8r Propnutt co ml c dion Po m p Preasare llcad "Only Proputed Slsllan at Connection Pump Station Stalic Head All on" On" TDH Pump Head GFiH "All On" {fcell On- {feet) {feet) TDII {feel) {feet} yeloclly {f } [Feet) 70 77.43 4.93 18.3 96 1.91t5 SU 77.6 5.45 18 3 2-0 1Id $I,2 77,81 S.13 19.3 aR24 2.2 1129p 77.77 5.18 183 2.3 I 1] 100 77.93 S.37 18.3 2 b l04 Pump MEMttfaclurer: Fiygt Model Flurnher: I NP 3127 io, ¢Ilcr ❑omeier: 1d6 iqm HursePa+rer: 1 l Vnliage� d6�v 3ph:tse Station Operation Check Proposed Operational Point NOA RG.2 GPM r@ 97 'I'DI i Check Wet well Cycle Times Wet Weil wet well Wet well Wet well Diameter Area Cycle Volume (feet) (gal f VF) (ft) (gal) 8.0 376 0.5 188 Fill = Wet well Volume - 12A minutes ADF ;tin -- Wet well Volume - 2.6 Minutes Pump hate - ADF Total — 15.0 minutes Cycle Time = 4.0 Cycles f Hour Meets Mi►rirrrtrrl: Cycle Time? 01, Meets Muxirfirr»r Cycle Tine? Q Station Operation Cheek Proposed Operational Faint No. 2 $G.2 GPM @ 24 TIDE Check Wet well CYcle Times Wet well Wet well Wet well Wet well Diameter Area Cycle Volume (feet) (gal f VF) R (gal) 8.0 376 0.5 18a Fill — Wet we]I Volume — 12.4 minutes ADF Run Wet well Volume — 2.6 minutes Pump Rate - ADF Total = 15.0 ininutes Cycle Time = 4.0 Cycles I Hour Meels Mir+imiim Cycle Time? OK Meets Maximtrm Cycle Tetne? OK Buoyancy Calculations Wet well Outside Dimensions We well Inside Dimensions Wet well Top Slab Elevation We well Invert Elevation Extended Sass Slob Diameter Extended Basc Slab Thi6ness Top Slab Thickness 9.00 3.00 Feet beet Fact Feet Fcct Feet feet 44.50 2110 11.00 1.00 F0.54 r�slw..lwrw Tnfet V.I.- of Wnt %Yell Structure Volume of Wet well Riser Suctions-- 1492 of Volume of Wet well Extended Baste 95 eF Total Volume of Wet well Structure— 1577 cf Calculate Total Volume of Water Displaced H2O Displaced = (Volume of wet well Structure)' (62.4 lbalcf) Ff20 Displaced= 98375 lbs Calculate Weight of Wet well C.ntnpoaents Section Top Slab Thickness (ft.) Riser - Total Vertical Ft. Base Slab Thickness (ll. Total Ht Weight 0.50 4771 23.36 46664 I.00 14255 Totals= 24.9 65691 Total Weight ofConcrcte in Wet well= 6569! Ibs. Calculate Submerged Weight of $oil Above Extended llaselFootine Total Area of Extended Base 95 sf Total Area of Wet weli Riser 64 sf AreaOFExtended Base less Wet well 31 sf Height ofSoit Above Extended Base 23 ft Volume ofSoiI Above Extended Base 71fi of Weight of Sail Above Extended Base (estimated) 54F lbslcf Total weight of Soil Above Extended Base 35$ l4 lbsfef Flotation Protection Required? Weight of Concrete and Weight of Soil Above Extended Base. 1171545 lbs Weight of Water Displaced By Wet Well'. 98375 lbs FYarallan Prorecdlon Required? I NO