Loading...
HomeMy WebLinkAboutWQ0042486_Application (FTSE)_20210521Central Files APS _ SWP — 41290021 Permit Number WQ00424$6 Permit Tracking SHP Program Category Status Project Type Non -discharge In review New Project Permit Type Version Permit Classiflcation Gravity Sewer Extension Pump Stations. & Pressure Sewer Extensions A Individual Primary Reviewer tyler Benson Coastal SWRule Permitted Flow Facility Permit Contact Affiliation Facility Name Majori'Minor Region 244 PeifferAvenue Subdivision Private Sewer Minor Wilmington County Location Address New Hanover Faciiitp Contact Affiliation Owner owner Name Owner Type Sand Peddler Properties LLC Non -Government Owner Affiliation Daniel Thompson 207 Cypress Ave DateslEvents Wrightsville Beach NC 2848049 Scheduled orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 412312021 JBSCONSULTING, PA 7332 Cotesworfh Drive Wilmington, NC 28405 (910) 619.9990 PLANN1NO - I:NGINFFR1Nii-PROJFC7' MANA[ilAWN1 April 21, 2021 Mr. Dean Hunkele NC DEQ -DWR , 127 Cardinal Drive Extension -+ A APB 23 Wilmington, NC 28405 26ZI RE: Permit Application 244 Peiffer Avenue - Minor Subdivision Wilmington, NC Dear Mr. Hunkele, Attached is a complete fast track application for the above -named system. I trust I have provided enough information for your timely review. This system involves extending +f- 296 LF of 6" C900 to serve four subdivided lots- This extension ties to gravity sewer awned and operated by CFPUA. This extension is slated to be privately owned and operated by the developer. As always if you have any questions please do not hesitate to call or email- Thanks in advance. Sincerely yours; (I A� 1 Bradford Sedgwick. PE Attached: Application (2) Project Narrative - in letter above Application Check ($480) FTSE Form [2j Street Level Map (2) Quad Map (2) Secretary of State Into Form DEV 03-19 State of North Carolina Department of Environmental Quality 9001.� Division of Water Resources ] 5A NCAC 02T .0300 -FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvislon of W#er Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: QOW IA Kg (to be comcierd by nwrt) 611 items must be completed or the application will be returned L APPLICANT IN1MP-MATIONI: 1. Applicant's name. Sand Peddler Properties. LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ®individual ❑ Corporation ❑ General Partnership ❑ Privately -owned Public Utility ❑ Federal ❑ Stawcounty ❑ Municipal ❑ Other 3. Signature authority's name: Daniel Thompson per 15A NCAC 02T .0106 b Title: Manager 4. Applicant's mailing address: 207 Cypress Avenue City: Wrigbtsville Beach State: NC Zip: 28480-1191 5. Applicant's contact infonnation: Phone number: (9IU] 2k2-MO1. Email Address: daniel&ntracoastalreahy.com U. PROJECT INFORMATION: 1. Project name: 244 Pcifer Avnue Subdivison 2. Appheation/Project status: ® Proposed (New Permit) ❑ Existing PerrniVProject If a modification, provide the existing permit number: WQ00 and issued daft- if new construction but part of master plan, provide the existing permit number. WQ00 3. County where prnjtwt is located: New Hanover 4. Approximate Coordinates (Decimal Degrees): Latitude: 3410638 Longitude;-77,84444' 5. Parcel M (if applicaNe)-. R066207-914-024-000 (or Parcel ID to closest downstream sewer) W. CONSULTANT INFORMATION: 1, Professional Engineer. Brad Sedgwick, PE License Number: 26378 Firm: )BS Consulting. PA Mailing address: 73.32 Cotesworth Drive City: Wilmivon State: NC Zip. 28405-� Phone number: (9t0] 619-9990 Email Address: bradsedgwick@hotmyil.com lY. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Permit Number: owner Name: V. RECEM NG DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ� Downstream (Receiving) Sewer Size: inch System -Wide Collection S.y-5tem Permjl NumbgIs! (if Jicable): WQCS Owner Name(s): FORM: FFA Od.l 6 .�. -- - - -- — Page l of 5 V1. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [--]No ®N/A 2. If the Applirturt is a Developer of lots to be sold, has a Developteraeional A¢reamertt (FORIuI: £lEV} been attached? ® Yes []No ❑N/A 3_ If the Applicant is a HQMJL _0p 0vvncrs' Association, has nnQpeiVion13 Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®ld1A 4. Origin of wastewater: (chock all that apply): ® Residential Owned ❑ Retail (stores, centers, mails) ❑ Car Wash ❑ Residential teased ❑ Retail with food preparation/service ❑ Hotel andlor Motors ❑ School l preschool l day care ❑ Medical l dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming PooLTitter Backwash ❑ Businesses / offices 1 factories ❑ Nursing Home ❑ M-er (Explain in Attachment) 5. Nature of wastewater : 100 % Domestie/Commercial % Commercial % Industrial Qtc 15A NCAC 02T-0103[20)) L-41-Is there a Pretreatment Program in effect? ❑ Yes ® No 6. Has a flow reduction been approved under 15A NCAC 02T--Q.1 !4(f)? ❑ Yes ® No ? If yes, provide a cony of flow reduction_ approval letter 7, Summarize wastewater generated by project: Establishment Type (see 02T.01 -K Daily 1 "%ffl Flow' ° No. of Units Flow Single Family Residential 3 BDRM W60 4 1440 GPD gall GPD gaV IGPD gal/ GPD gaV GPD — - - gav GPD Total GPD a See I5A NCAC 027.0114(b). M. (e)f 1) and (cH2) for caveats to wastewater design flow rates (i.e_, minilrsum flaw per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 4ZA-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0 r 14 shall be determined using available flow data, water using fixtum, occupancy or operation patterns, and other measured dam- S . Wastewater generated by project: 1440 GPD (per 15A NCAC 02T .0114) J+ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Nurnber; ❑ Rehabilitation or replacement of existing sewer with no now flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VD. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDf Wravi#y Sewers): 1. Summate gravity sewer to be permitted: Size (inches) Length {feet) Material 6 296 C900 r' Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria 8 section Ill contains information related to minimum slopes for gravity sewer(s) Y Oversixing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (I(Applicable) - 02T A305 & KDC(PUMP Stateans/Force Maim): COMPLETE FOR EACH PtJN P STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: NIA 2, Approximate Coordinates (Decimal Degrees): Latitude: Longitude: 3. Design flow of the pump station: millions gallons per day (firm capacity) 4, aperationai paint(s) of the purnp(s): — -gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size(inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T _0305(h)(I): ❑ Standby power source or plump with automatic activation and telemetry - I SA NCAC 02T .0305(hx 10B); ➢ ,Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T 03 o5(h)(I)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1 XC): It shall he demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. a If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump. including travel timeframes, shall be provided in the case of a multiple station power outage. FC1RM FTA 04-16 Page 3 of 5 Ix. SETBACKS & SEPARATIONS — (0213.0200 & 15A NCAC 02T .0305(f)): i. Hoes the project comply with all separations found in 15A NCAC 02T .0305(fl & (g) ❑ Yes ❑ No 'e 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter' Sep=tion Rewired Storm sewers and other utilities not listed below vertical 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains horizontal 10 feet Reclaimed wager lines vertical - reclaimed over sewer l8 inches 2 The Reclaimed water lints(horizontal - reclaimed over sewer "Any private or public water supply source, including any wells, WS-1 waters of Class I or Class Il impounded reservoirs used as a source of drinking water 100 Feet "Waters classified WS (except WS-1 or WS-V ), H, SA, ORW, HQW, or SB finrr► normal hi h water or tide elevation and wetlands see item IX.2 50 feet "Arty other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feels Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any sw' is 10 feet Final earth de vertical 36 inches A l5A NCAC 02T.0305 contains alternatives whcre separations in 02T_0305(ft cannot be achieved. • n 'Stream classifications can he identified using the Division's NC Surface Water Classification$ webpa e )k If noncompliance with 02T.0305(f) or (g], sec Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes [:)No ❑ NIA g Seethe Division's draft separation requirements for situations where separation cannot be meet A Na variance is required if the alternative design criteria specified is utilized in design and construction Y As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ®NIA g This would include Trout Buffo d Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ®N❑ individual permits or401 Water Quality Cerkifications? F Information can be obtained from the 401 & Duffer Permitting Branch 5. Does project comply with 15A NCAC 027'.010McX6] (additional permits/certifications)? ® Yes ❑ No Par 15A NCAC 02T.01451cH0. directly related envirownental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erasion and sedimentation control plans, stonnwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402. "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streamhanks that is subject to erosion that undermines or deteriorates the sewer. [:]Yes ® No ❑ NIA F If yes. include an attachment with details for each line, including type (aerial line, size, material, and location). H4h priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 115A NCAC 02T-0403(a)(S) or the permitee's individual System -Wide Collection permit. FORM: FrA 04-16 rage 4 of 5 DowSign Envelope 10_ DDIA9F34-DECE-46AF-9043-0765C74D4C76 X. CERTIFICATIONS: 1, Does the submitted system comply with 15A iNCAC .0 the Minimum desigI3 Crit0a_for the Permitting of Pump Stagign and Force Maips-Cla-tesly_eTIJ1and the Gravity Sewer Minimum Design Criteria (latest versions as applicable? ® Yes ❑ No If No, complete and submit the Variance/A Item alive rksign Request application (VA DC I0-14) and supporting documents for review. Approvalaf & uect is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineers Certification: 45�[, I Te attest that this application far (Professional Engineer's name from Application Item 111.I.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications. engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria For the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that l have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with Gencral Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as -civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's CerESradion per 15A NCAC 02T .0 106(b): attest that this application for name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included. this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters orthe land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.6A and i4.3-21_ 5.-0% any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000 as well as civil penalties up to $25,000 per violation. wdtro:,,, 4/19 2021 Signature: Dp�d t "`�^'! Date: FLIaBA107mdn FORM: FTA D4-16 Page 5 of 5 North Carolina secretary of State Search Results hiTps://www.sosnc.gov'online-services/search/Busine5s- Registrati. - - File an Annual Report/Amend an Annual Report • Upload a PDF Filing • Order a Document Online - Add Entity to My Email Notification List • View Filings • Print a Pre -Populated Annual Report form • Print an Amended a Annual Report form Limited Liability Company Legal Name SAND PEDDLER PROPERTIES, LLC Information Sosld: 0482392 Status: Current -Active O Date Formed: 112211999 Citizenship: Domestic Annual Report Due Date: April 15th CurrentAnnual Report Status - Registered Agent: Thompson, Daniel K. Addresses Mailing 207 Cypress Avenue Wrightsville Beach, NO 28480-1918 Reg Office 207 Cypress Avenue Wrightsville Beach, NO 28480-1918 Company Officials Principal Office 207 Cypress Avenue Wrightsville Beach, NC 2B480-1918 Reg Mailing 207 Cypress Avenue Wrightsville Beach. NC 28480-1918 All LLCs are managed by their managers pursuant to N.C_G.S. 57D-3-20, Manager Administrative Member DANIEL K. THOMPSON Maria Thompson 207 Cypress Avenue 207 Cypress Avenue Wrightsville Beach NC 28480 Wrightsville Be NC 2848a 4/29/2021. t 2:43 PM State of North Carolina DWR Department of 1 nvironmental Quality Division of Water Resources Dhrislon of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Sand Peddler Properties, LLC Project Name for which flow is being requested: 244 Pciffer Minor Subdivision More than one FTSE may Se required for a single project if the owner of the WW P es nor responsible for all pump sYafrons along the route of the propwwd waskwafer flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: M'Kcan MafiitI (Sout_hside) VVWTP b. WWTP Facility Permit #: NPDES NC 0023973 rill flows are in MGD c. V4'VVTP facility's permitted flow 12.000 d. Estimated obligated flow not yet tributary to the WWTP 2.790 e. WWTP facility's actual avg, flow 8.044 ` f. Total flow for this specific request 0.002440 g. Total actual and obligated flows to the facility 10.836 h. Percent of permitted flow used 90.3 I1. Campicte this section for each pump station you arc: re4ponmbie for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WW'TP: (A) (B) (C) (D)=(B+C) (E)-(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow" Current Tributary Flaw Plus (Name or Permit Capacity, • (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD` Flow, MGD MGD Flow Cspacity*V* 34 NIA 14.976 5.76 4.O16 0,179 4.195 1.565 39 NIA 1.800 0.720 0.228 0.070 0.297 0,423 * The Firm Capacity (design flow) of any pump station is defined as the maximum pwnped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WW IT where the Available Capacity is { 0. Downstrm u Facility Name (Sewer); Cape Fear Public Utility Authority Downstream Permit Number: Page 1 of 6 1= FSE 10-18 III. Certification Statement: I IeffTh-- e, CFPUA Eng. Mgr certify to the beast of my knowledgc that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the hest available data. This certification applies to those items listed above in Sections I and 11 plus all attached planning assessment addcndums for which I am the responsible party. Signature of this form certifies that the feceiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. e] d 2.1 . SIgNdgl0flicial Si iature re Title of S gning Official Page 2 of 5 ME 10-IS 34" 12'23.0"N 77°50'40.0"W - Gaggle Maps Go, -gle Maps 34°12'23.0"N 77°50'40.0''W 9 5ar"t" ' 04rof1dCr dt .. - �� r i QH.ctrcelMagic Slere a Rif Wow dw iJ:...t , r•.nT A&an R Andai Oft PLLC 9 # R LandlaP FUMY PrpGlce !yam t+ https:llwww.google.comlmagslplace134° 12'23.0"N+77050'40.0" W/@34.2073628,•77.84... carder UI - F•ew; 8 C1a.Iro I.�I*%nnwillo ItOG wllmmulvn ARI.*Has p1fal Lucky 51■1 cmnt PWO Jahn's 4NZ Z S I�Fa-al - [Ir:.try ne DIM M � f'avrs R Cfaws Foo Can r �x r'w f 5 , rr Google N Map data 02021 200 f[ + of 2 4/2912021, 12:46 QM