HomeMy WebLinkAboutWQ0008254_Application (FTSE)_19930804MEMO TO:
FROM:
SUBJECT:
State Review Group
est
everts
'Kgio al Supervisor
Procedure Four (4)
WQ0008254
Ashton Forest South - Subdivision
Sewer Extension - Public
City of Fayetteville
Cumberland County
Division of Environmental
Management
Fayetteville Regional
Office
08116/93
Date
State Review Group Review
Engineer Angela Griffin
Regional Office
Contact Ricky Revels
1) Name of wastewater treatment plant to receive the wastewater:
PWC of Fayetteville - Rockfish Creek Wastewater Treatment Plant
2) WWTP design capacity 6.0 MGD
3) NPDES Permit No.: NC0050105 Expiration Date: 05/31/96
4) Compliance Information:
Present treatment plant performance
for previous 12 months - beginning _07/01/92_
(See attached self -monitoring data)
5) Quantity and type of wastewater from proposed sewers: _41,040GPD
domestic 100% ; industrial
; other
6) Volume from previously approved projects not yet tributary to
WWTP 2,561,056 GPD
7) Regional Recommendations: Approval
KTS/RR/rr
Enclosure
X Denial
State of North Carolina."'
Department of Environment,
Health and Natural Resources
Division of Environmental Management
James B. Hunt, Jr., Governor
Jonathan B. Howes, Secretary
A. Preston Howard, Jr., P.E., Director
August 4, 1993
MR TIMOTHY WOOD
PWC/FAYE 1TEVILLE
PO DRAWER 1089
FAYE1-1'EVILLE, NORTH CAROLINA 28302
Dear MR WOOD:
*CCgA
EHNF�
A! I(4 6 1993/.
J
ENV. MANAEMENT
FAY TTEVILLE REG. OFFICE
Subject: Application No. WQ0008254
Ashton Forest
Sewers -Public
Cumberland County
The Division's Permits and Engineering Unit acknowledges receipt of your permit application and
supporting materials on August 2, 1993. This application has been assigned the number shown
above. Please refer to this number when making inquiries on this project.
Your project has been assigned to Angela Griffin for a detailed engineering review. A technical
acknowledgement will be forthcoming.
Be aware that the Division's regional office, copied below, must provide recommendations from the
Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the
Division.
If you have any questions, please contact Angela Griffin at (919) 733-5083.
7 erely,
g:/,(&;, (/774/,&00
Donald Safrit, P.E.
Supervisor, Permits and Engineering Unit
cc: Fayetteville Regional Office
Bennett Engineering
Pollution Prevention Pays
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015
An Equal Opportunity Affirmative Action Employer
State of North Carolina
Department of Environment, Health, and Natural Resources
Division of Environmental Management
Non -Discharge Permit Application
(THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL)
GRAVITY SEWER EXTENSION
I. GENERAL INFORMATION:
1. Applicant (corporation, individual, or other ): Pig yy . t-f't v/ /I P Pt.( h /1r,
' VNdr/s Cc, mrn/_ 5ie/7
2. Print Owners or Signing Official's Name and Title (the person who is legally
responsible for the facility and its compliance): 7-217-7 fry "
3. Mailing Address: f 0 1U I^e wP r /oA r
City: pet y /e, State: /'/C Zip: 2 g3a2
Telephone No.: ( q /4) 4 g4. - /4 e, /
4. Project Name (subdivision, facility, or .establishment name - should be consistent with
project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.):
5. Application Date: g J t.r / 9 3
6. Fee Submitted: $ 2,00
7. County where project is located: GG/ m . ri 4 /'7 CI
II. PERMIT INFORMATION:
1. Permit No. (will be completed by DEM): • /iQy 0 g i-
2. Specify whether project is: X)( new; renewal*; modification.
*If: renewal, complete only sections I through III and applicant signature
(on pg.5). Submit only pgs. 1, 2, 5 (original and '3 copies of each). Engineer
signature not required for renewal.
3. If this application is being submitted as a result of a renewal or modification to an
existing permit, list the existing permit number N44 and issue date
4. Specify whether the applicant is Xa( public or private.
FORM: GSEA 4/91 Page 1 of 6
.Jlttl V 11 1 JL. VY •✓aV1I
PAGE 2 (4/91)
III. INFORMATION ON WASTEWATER:
1. Nature of Wastewater: /90 % Domestic; % Commercial;
% Industrial; % Other waste (specify):
2. Please provide a one or two word description specifying the origin of the wastewater,
such as school, subdivision, hospital, commercial, industrial, apartments, etc.:
�t.4.h /iais/0t'7
3. Indicate any parameter (and its concentration) that will be greater than normal domestic
levels: P
4. If wastewater is not domestic in nature, what level of pretreatment has been provided to
ensure protection of the receiving wastewater treatment facility?
N/A
5.' Volume of wastewater generated by this project: et /,.4 gallons per day
6. Explanation of how wastewater volume was determined:../.ZO G P
X 3 .1-�1e:1roo/11_5 JC / /d _St rr j /6° fair i/y h uses
IV. DESIGN INFORMATION:
1. Brief project description: Ea(, f 'e /-r �5 4,21142f 8 " Go � c t'1o/7
17' ,rzs Gr17/ Si"oufto/I /ine. 17.e:P //ad-
.swiyJP arnii y c.c.s /_ri ,f4./4 fort ior�s�-
.Sout- �S u 1, - rv1.s/0/7
2. Name of wastewater treatment facility receiving wastewater: ,F 2 k f /s 1t
rrP rn-1—
a. Facility permit no.: l C
b. Engineer should provide statement of his evaluation of downstream sewers to
accept the wastewater: �%� / 2 //r" /'1'1� �/T-
.Sf-r�Qfr1 Q/'1 d Case/
411 (.2 rP 1 1ii )47r
-� � di /or • 2 of 6
GRAVITY SEWER EXTENSION
PAGE 3 (4/91)
3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C
factor or N factor is used and circle C orgbelow:
Dia. Length Pipe C oRN) Min. Max. Minimum Max. Minimum
(In.) (Lin. Ft) Material Factor Slope % Slope % Velocity (fps) Vel.(fps) Cover (in)
b y Vcp _f Q.sl0 9.z.5 2.o J6S' 43
40 J2LL -,.S/— A 4-0 e_f_7n 2 . -2' k
NOTE: The minimum velocity must not be less than 2 fps.
For public sewers the minimum diameter is 8 inches.
4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor
spacing shall be as follows:
a. 36 feet separation for slopes of 21% to 35%;
b. 24 feet,separation for slopes of 36% to 50%;
c. 16 feet separation for slopes of 50% and greater.
For velocities greater than 15 fps, it is strongly recommended that measures be
considered which will protect the sewers and manholes from erosion. For velocities
greater than 20 fps, erosion control measures must be specified.
For any excessive slopes or velocities that will occur in any sewer line segment, what
measures have been taken to protect the sewer pipe and manholes?
i
5. Maximum sewer reach length between manholes: 40U linear feet.
.5 heert#S(Ttinyerine or) e9too--4hao .4 oo- 8i'O
6. This sewer line segment occurs between manhole no. and manhole no.
-si her lc,Cre*LeLscrrr Dr s'7/7--9 4--/7 No.
7. Does the owner/operator have the ability to clean this length?X X Yes
8. Sewer subject to existing or planned traffic bearing loads? Y X Yes No.
If yes, what measures are being taken to enable the sewers to withstand the loads?
e p, 170=. ro .5 1 r't-
liw
ri' eri c h ..ba c k / / i1-7a f er,4 / u 1/ // .fie �rde uQ f'e.
9. Outside drop manholes are provided where invert separations exceed: 2 •S feet.
10. Identify (by manhole number) those manholes that have drop connections: _5 /jePt.- 4_
b -t-p r- Rd-s�-.�.
3 of 6
e ..
GRAVITY SEWER EXTENSION
PAGE 4 (4/91)
11. Maximum allowable infiltration/exfiltration test rate:
Note: Must not exceed 200 GPD/ pipe dia. in./ mile. 1OO GPD/ pipe dia. in./ mile.
12. Minimum separation distances as shown on the plans or addressed in the specifications:
a) 100 ft. horizontal separation from wells or other water supplies? .,X Yes _ No
b) 12 in. vertical separation from storm sewer or ferrous pipe
sanitary sewer specified? , Yes No
c) 10,ft horizontal separation from water'mains or 18 in. vertical,
separation (water over sewer) or ferrous pipe specified? -X. Yes _ No
13. Are manholes subject to flooding? ..Yes . No
14. If yes, are manhole rim elevations 1 foot above 100-year flood level, ,,24 Yes _ No
(100 year flood elevation should be indicated on plans)
15. Or are manholes watertight and vented 1 foot above the 100-year
flood elevation ( should be shown on plans): P AYes _ No
16. Identify (by manhole number) those manholes that are vented: /WA
17. Does this project involve any stream crossings? _ yes .4. no. If yes, what precautions
or special features have been utilized to ensure protection of the sewer line and not
restrict stream flow? Identify the sheet of the plans and station number where stream
crossings are located:
THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE
DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF
THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL
Required Items
a. One original and three copies of the completed and appropriately executed application form.
b. Three- sets of detailed plans `and specifications signed and 'sealed by a. North Carolina
Professional Engineer. The plans must include a general location map, a plan view of the
sewer extension, a profile- of the sewer extension, and must show the proximity of the
sewer extension to other utilities and natural features. Specifications may be omitted for
delegated authorities. Each sheet of the plans and the first page of the specifications must be
signed and sealed. Thiee copies of the existing permit if a renewal or modification.
c. The appropriate pemtit processing fee, in accordance with 15A NCAC 2H .0205(c)(5).
d. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting
the wastewater flow from this project is different from the applicant of the project, then a
letter must be provided from the owner/authority of the WWTF specifying the volume of
flow that will be accepted. The letter should be a recent letter and should refer to the project
by the same name as that identified on the application and the plans/specifications.
e An Operational Agreement (original and two copies) must be submitted if the sewer
extension will be serving single family residences, condominiums, mobile homes, or town
houses and if the subject sewer extension is owned by the individual residents, a
homeowners association, or a developer.
4 of 6
GRAVITY SEWER EXTENSION
PAGE 5 (4/91)
Name and Complete Address of Engineering Firm: f3W rr
RoLar t-A trh', PE'
City: Fey /7 e. I.////e State: /V G Zip: 78 '301--6-C44-
Telephone No. (J /% 4 84 -o .577
Professional Engineer's Certification:
I,'o be r 7' M n n'tt , attest that this application for AS hi" > /7 Petw:574
Soiv f-h Se/ S e W F' EX f- has been reviewed by me and is accurate
and complete to the best of my knowledge. I further attest that to the best of my knowledge the
proposed design has been prepared in accordance with the applicable regulations. Although certain
portions of this submittal package may have been developed by other professionals, inclusion of
these materials under my signature and seal signifies that I have reviewed this material and have
judged it to be consistent with the proposed design.
North Carolina Professional Engineer's Registration No. 3,452...3
Print Name of Engineer RvJ t r t /Vi R c=, 17. a .
f
Seal and Signature (specify date):
SAL
Jul 13 3823 •
Applicant's Certification: T M �E.
'''mmmm,ti,, I, ,7''/ rrl o 7' h y f /1/,› , attest that this application for As-Qn
F 7 res7' _ 7 76/-1 .sul2 /o/7
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand
that if all required parts of this application are not completed and that if all required supporting
information and attachments are not included, this application package will be returned as
incomplete.
Signature
Date 7 Q�
THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPO ' T NG
INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS:
NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT
WATER QUALITY SECTION
PERMITS AND ENGINEERING UNIT
POST OFFICE BOX 29535
512 NORTH SALISBURY STREET
RALEIGH, NORTH CAROLINA 27626-0535
TELEPHONE NUMBER: 919/733-5083
5 of 6
State of North Carolina
Department of Environment, Flealtlr, and Natural Resources
Division of Environmental Management
512 North Salisbury Street • Raleigh. North Carolina: 27626-H535
lames G. Martin, Governor
William W. Cobey, Jr., Secretary
Memorandum
To: Delegated Municipalities
From: Steve W. Tedder, Chief t(
Water Quality Section
Subject: Delegated Municipalities Checklist for Revised Non -Discharge Penult . Appiicai:c .;
The Division of Environmental Management's Water Quality Section has revised the
Gravity Sewer Non -Discharge Permit Application Form. The form now incorporates the basis:
information that the Division feels is necessary in order for the delegated municipalities to perform
review on a gravity sewer project for the Division; therefore, the Division will no longer require :hilt
the "Delegated Municipalities Gravity Sewer Design Checklist" be completed and submi tted.
however, require that the delegated municipality perform the same type of review as always required
and complete the bottom portion of this page and attach it as the last page of. al! gravity
applications that are being submitted as a delegated municipalities project. If you have any question
on this matter, please contact Mr. Randy Jones at 919/733-5083.
DELEGATED 1VMUNICIPALITY GRAVITY SEWER CERTIFIT'ATToN
(THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL)
Applicant: PUBLIC WORKS (XIMMTSSION OF THE CITY OF FAYETTEVILLE
May I, 1991
G:ur_ i _ ,,.•tt.
Project Name: ASHTON FOREST SOUTH
Delegated Municipality Reviewer's Certification:
I, VICTOR GANJEHSANI , attest that the subject plans and
specifications have been reviewed under my supervision and that those plans and specifications are
consistent with the information that has been specified on the Non -Discharge Application and the
Division of Environmental Management's minimum design requirements for gravity sewer projects.
Delegated Municipality Reviewer's C Prn*>edrnal Erwineer's RPTCtr tion No.: 14368
Seal and Signature (specify date):
FORM: DMGS 4/91
PAGE 1 OF 1