Loading...
HomeMy WebLinkAboutWQ0042561_Application (FTSE)_20210520State of North Carolina j Department of Environmental Quality , Division of Water Resources 15A NCAC 02T A300— FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: ry $ 00 (4 Sls 1 (Io be completed h� I)NNK) All items must be completed or the innlication will be returned 1. APPLICANT INFORMATION: Applicant's name: Welsummer Yards, LLC (company, municipality, 1-10A, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Federal ❑ State/County ❑ Municipal 3. Signature authority's name: Stephen Brock per 15A NCAC 02T .0106(b) Title: Member 4. Applicant's mailing address: 893 Holly Dr. W City: Annapolis Slate: MD Zip: 21409- 5. Applicant's contact information: Phone number: (336) 833-3697 Email Address: Stephen r brockyi.com ❑ Pri%-atelN-Owned Public Utility 'ept of Environmental Quality MAY 2 0 202f Raleigh Regional Office 11. PROJECT INFORMATION: I. Project name: Welsummer Yards 2. Application+Project status: ® Proposed (New Permit) ❑ Existing PermiliPmject If a modification, pro%-ide the existing permit number: WQ00 and issued date: If new construction but part of a master plan; provide the existing permit number: WQ00 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.518657-- Longitude:-78.554678" 5. Parcel ID (if applicable): 13EO5012C (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: I. Professional Engineer: Homer Wade License Number: 10771 Firm: Borum. Wade and Associates. P.A. Mailing address: 621 Eugene Court, Suite 100 Cite: Greensboro State: NC Zip: 27420-1882 Phone number: (336) 275-0471 Email Address: imcginleN-.`i-i),borum-+vade.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facilit% Name: Central Johnston County Regional Wastewater Facility Permit Number: NCO030716 Owner Name: Johnston Count%- V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0019761 Do%%nstream (Recei%-ing) Seer Size: 8 inch S�-Slem L1,ide Collection S\Stem Permit Numbcr(s) 01applicable): WQCS00060 Owner Name(s): Johnston Count FORM: FTA 04-16 Page I of 5 V1. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®NlA 2. If the Applicant is a Developer of lots to be sold, has a Dc%-cloixc '%.- icrational Agreement t FQR\ I: DEN) been attached? ❑ Yes ❑No ®NIA 3. Ifthe Applicant is a I lome Property Oancrti :Association, has kill Operational ASjyement tl-OR\l. I;0A) been attached? ❑ Yes ❑No ®NIA 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparationfservice ❑ Hotel and/or Motels ❑ School.' preschool / day care ❑ Medical r" dental `veterinary facilities ❑ Swimming Pool !Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool,Tilter Backwash ❑ Businesses.-' offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : % Domestic.+Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) 4 Is there a Pretreatment Program in effect? ❑ Yes ❑ No G. Has a flow reduction been approved under 15A NCAC 02T .01 14 ? ❑ Yes ® No > If yes, provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 021.0114(f1) Daily Design Flow' b No. of Units Flow 0 gal?day 0 0 GPD gal. day 0 0 GPD gal GPD gal GPD gal: GPD gal.-' GPD Total 0 GPD a See 15A NCAC 02T .01 14(b). (d). (c1( I) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 14) shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. S. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) > Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ® Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flo%% expected ❑ Other lExplain): T DORM: I -TA 04- I G Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & _-IDC (Gravih° Sewers): . Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 14.10 PVC ➢ Section II & 111 of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section [11 contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vlll1. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T.0305 & MDC (Pump Stations/Force Alai lg: COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: Welsummer Yard Temp Pump Station 2. Approximate Coordinates (Decimal Degrees): Latitude. 35.518254` Longitude:-78.554682" 3. Design flow of the pump station: 0.02016 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 100 gallons per minute at 27.5 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 4" 164.57 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(By ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility Or if the pomp station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORNI- FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(I)): 1. Does the project comply with all separations found in I5A NCAC 02T .0305(t) & (g) ® Yes ❑ No > 15A NCAC 02T.0305(t) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Re aired Stone sewers and other utilities not listed below vertical 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed waterlines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earthrade vertical 36 inches > 15A NCAC 02T.0305(u) contains alternatives where separations in 02T.0305(f) cannot be achieved. > **Stream classifications can be identified using the Division's NC Surface Water Classifications web age > If noncompliance with 02T.0305(t) or (,,,).see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes [—]No N MA > See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N;A This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? > Information can be obtained from the 401 & Bulfer PermitlinX Branch 5. Does project comply with I5A NCAC 02T_0105(c)(6) (additional permilVeertifications)? ® Yes ❑ No Per ISA NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NICAC 02T.0-102, '`high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ❑C No ❑ NIA > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the perrnitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with , the and the as applicable? ®Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the re -guest is reguired Priorto submittal f the Fast Track Aeolication and supporting ocuments. 2. Professio Engineer's Certification: WADE attest that this application for (Professional Engineer's name from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: CA���+', a ;,•ar ssr0 . a SEAL f 10771 w t r V • i x� 3. Applicant's Certification per I SA NCAC 02T .0106(b): 1, attest that this application for (Signature Authority's name &title rom Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this pemi t be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes and , any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: _ Date: FORM: FTA 04-16 Page 5 of 5 ® A Engineers - Planners Surveyors Borum, Wade and Associates, P A. May 18, 2021 Jason Robinson DWR - Municipal Permitting Branch 3800 Barret Drive Raleigh, NC 27609 Phone: (919)-791-4200 Regarding: Welsummer Yards Apartments Old Roberts Rd. Benson, NC 27504 Dear Sir or Madam: Ne Dept of rnvironmcntal Qualit) MAY 2 0 2021 J1gig4 Regional Office Please see the enclosed documents for review and approval for the Welsummer Yards Apartments private pump station (to be owned and maintained by Welsummer Yards LLC). This project is a 72 unit MFR development that is to be serviced by a private pump station, and a new public sanitary outfall [permitted separately]. Included in this package are the following: 1. 1 sealed FTA 04-16 and supporting docs(site maps etc). lNote: Public portion to be permit separately per NCDEQ: Jason Robinson] 2. 1 check for $480.00 payable to NCDEQ 3. 1 Flow tracking form (FTSE 08-13) Please call if you have any questions. Sincerely, /--' /7&0d+ James McGinley, P.E. (ext. 107: Cell: 336-812-1798) 621 Eugene Court, Suite 100, Greensboro, NC 27401-2711 - PO Box 21882, Greensboro, NC 27420 1882 Phone 336-275-0471 • Fax 336-27S-3719 Website: aww.horunk wa&.cnut NC License #: C•0868 3 1` 1✓� ��� d 'SHEFFIELU OR 5 H V L 13 a S �o'oarvHsb� 0 0 o V K J J N 0 ti R££DYCR££K RD E u '-OR- Cl. N I �� r �yLLiAµ ' RALEIGH E � � v f Q ' In a of -2 urW ? } cu f� i r ` n a p '� Q7 CL O oyH��nhJ Q s� �J ry U a O LL �= � I -1 -4 (U [13 U A o C m (ti3 LL u UU 3 c"' 0 cn _ cn Q o ca Lu n � O �u o c � m !V 4f 1 r" N f 2 O f'+ R I i r`t a1 Pump Station-CALCS.xls PUMP STATION DESIGN DATA: PEAKING FACTOR 4.17 FLOW INFORMATION 20,160 gpd = 14.00 gpm Pump Q: 100.0 gpm Peak Q. 58.38 gpm Pump TDH: 27.5 ft WET WELL INFORMATION Fillets?: Yes No Alarm?: Yes No Auto -dialer?: Yes No Security?: Yes No Vent/Screen?: Yes No FORCE MAIN INFORMATION 3 ft Cover?: Yes No Air Relief Valve?: Yes No NA Check Valve?: Yes No Gate Valve?: Yes No HEAD Static Head: 10.57 ft Effective Length: 1,454 ft C value: 140 HI + HE 9.53 ft TDH: 20.10 ft TDH Design: 27.50 ft % difference: 1 -26.93 % Pump On Elev. 256.36 ft Pump Off Elev: 255.36 ft Inside Diameter(chamber): 6.00 ft (For circular PS) X Dimension: 0.00 ft (For square or rect. PS) Y Dimension: 0.00 ft (For square or rect. PS) Cross Sect. Area. 28.27 sq ft Working Volume: 211.52 gal Detention Time: 15.11 min Pump Run Time 1: 2.12 min Pump Run Time 2: 0.77 min Total Time Cycle: 0.30 hr Pump Cycling: 3.34 cycles/hr (should be between 2 and 8) Length: 1,322 ft Diameter: 4.0 in High Point Elev. 265.93 ft Pump Off: 255.36 ft to 140 C VALUES PVC: 130 110 Vitrified Clay: 125 DIP: EMERGENCY STORAGE TIME ft All On: 255.36 ft Can back up to: 257.48 ft 448 gal in wet well VELOCITY Approximate velocity = 2.56 ft/sec Hazen Williams (should be r or = 2 fps) 2.55 ft/sec V=Qpump/A POWER RELIABILITY Stand-by power. Generator: On Site Auto Dialer: Yes Power Reliability: N/A 1097 gal in line 1545 gal total 110 min storage time