Loading...
HomeMy WebLinkAboutWQ0008139_Application (FTSE)_19930713State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director July 13, 1993 MR TIMOTHY WOOD PWC/FAYE 1-1'EVILLE PO DRAWER 1089 FAYErlEVILLE, NORTH CAROLINA 28302-1089 Dear MR WOOD: AvA CDEHNR Subject: pplEIVIT JUL ' 16 1993 ENV. MANAGEMENT cAYETTEVILLE REG. OFFICF Application No. WQ0008139 Ridge Wood Subdivision Sewers -Public Cumberland County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on July 8, 1993. This application has been assigned the number shown above. Please refer to this number when making inquiries on this project. Your project has been assigned to Angela Griffin for a detailed engineering review. A technical acknowledgement will be forthcoming. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact Angela Griffin at (919) 733-5083. CiLlc rely, i? Donald Safrit, .E. Supervisor, P rmits and Engineering Unit cc: Fayetteville Regional Office Moorman, Kizer & Reitzel, Inc. Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer r Y 1 ,Wia_ State of North Carolina Department of Environment,>Health, and Natural Resources Division of Enviinniihciital1 Management Non-Disrhargc Permit Application (THIS -FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL) GRAVITY SEWER. EXTENSION PUMP STATIONS; AND PRESSURE SEWERS I. GENERAL INFORMATION: 1. Applicant (corporation, individual, or other): Public Works Commission of The City of Fayetteville, NC 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): Timothy Wood, Manager 3. Mailing Address: Post Office Drawer 1089 City: Fayetteville State: NC Zip: 28302-1089 Telephone No.: ( 919 ) 483-1382 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.): Ridge Wood Subdivision 5. Application Date: June 1993 6. Fee Submitted: $ 200.00 7. County where project is located: Cumberland H. PERMIT INFORMATION: 1. Permit No. (will be completed by DEM): Goicoorngt_g 2. Specify whether project is: x new; renewal*; modification. *If renewal, complete only sections I through III and applicant signature (on pg.5). Submit only pgs. 1, 2, 5 (original and 3 copies of each). Engineer signature not required for renewal. 3. If this application is being submitted as a result of a renewal or modification to an existing permit, list the existing permit number and issue date 4. Specify whether the applicant is x public or private. FORM: GSEA 4/91 Page 1 of 6 PAGE-2 (4/91) III. INFORMATION ON WASTEWATER: l . Nature of Wastewater: 100 % Domestic- % Commercial. Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: 151 lot single family subdivision 3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels: NONE 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? N/A 5. Volume of wastewater generated by this project: 54,360 gallons per day 6. Explanation of how wastewater volume was determined: There will be 151 each 3 bedroom homes in Ridge Wood. 120 gal/bedroom. Average 360 GPD/Residence.. IV. DESIGN INFORMATION: I. Brief project description: Ridge Wood. Extend 8 " sanitary sewer to serve 151 lots in Rockfish Creek 2. Name of wastewater treatment facility receiving wastewater: Treament Plant a. Facility permit no.: NC 0050105 b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: PWC will provide a sewage pumping station on a lot west of Bailey Lake Road from which a 6" I.D. force main (2700') wilt tie into an existing 6" f.D. force main (175') at the rear of Lots 19 ant) (A'tof Pheasant Ridge Subdivision. Downstream 8" & 15" gravity sewer has ample reserve capacity to accommodate the discharge from this lift station. GRAVITY SEWER EXTENSION & PUMP STATION PAGE 3 (4/91) 3. Summary of sewer pipe by diameter size and pipe material. indicate here whether C factor or N factor is used and circle C or N below: MinimuDia. Length Pipe C or N Min. Max. Minimum (In.) (Lin. Ft) Material Factor Slope % Slope % Velocity(fps) Vel(f s Cover (in) 8 5781 V.C. 0.013 0.45 5.31 2.3 7.90 12 15 V.C. 0.013 0.22 0.22 2.00 2.0 54 NOTE: The minimum velocity must not be Tess than 2 fps. For public sewers the minimum diameter is 8 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be as follows: a. 36 feet separation for slopes of 21% to 35%; b. 24 feet separation for slopes of 36% to 50%; c. 16 feet separation for slopes of 50% and greater. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control measures must be specified. For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? 5. Maximum sewer reach length between manholes: 452 linear feet. 6. This sewer line segment occurs between manhole no. 0+00 and manhole no. 4+52 Le f few Ave 7. Does the owner/operator have the ability to clean this length? x Yes No. 8. Sewer subject to existing or planned traffic bearing loads? x Yes No. If yes, what measures are being taken to enable the sewers to withstand the Loads? Inside 9 Ottwde drop manholes are provided where invert separations exceed 2. 5 feet 1 0 Identify (by manhole number) t'lose manholes that have drop connccttons N/A -12. Minimum separation stances as shown on the plans or addressed in the specifications: a) 100 ft. horizontal separation from wells or other water supplies? _ Yes — No b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? g — Yes — No c) 10 ft horizontal separation from water mains or 18 in. vertical separation (water over sewer) or ferrous pipe specified? ...�C Ycs — No 13. Are manholes subject to flooding? _Yes No 14. If yes, are manhole rim elevations 1 foot above 100-year flood level, (100 year flood elevation should be indicated on plans) — Yes — No 15. Or are manholes watertight and vented 1 foot above the 100-year flood elevation ( should be shown on plans): —Yes — No 16. Identify (by manhole number) those manholes that are vented: 17. Does this project involve any stream crossings? — yes g no. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: GRAVITY SEWER EXTENSION AND PUMP STATION PAGE 5sof 10 (4/91) V. PUMP STATION INFORMATION Ridgciliood Development' j, O 1. Pump Station No.: (A separate sheet V.1 through V.15 should be submitted for each: pump station) 2. Name of closest downslope surface waters: Unnamed tributary to Beaver Creek 3. Classification of closest downslopc surface waters: Ott (as established by the Environmental Management Commission&ispecifed on page 6 of this•applic.). 4. If a power failure at this pump station could impact -Waters -classified as WS, S& B, or SB, describe which of the measures are hang implemented to prevent such impact, as required in 15A NCAC 2H .0200: 5. What size pumps are provided? 3" Duplex Gorman -Rupp Pumps 6. How many pumps arc provided? Two GPM 7. What is the maximum capacity of the pump station? 54360 GPD 8. What is the design total dynamic head? 50 feet 9. How many pumping cycles will occur at the design flow rate? 4 cycles per hour 10. Check if provided at pump station: Alternate Power Source Wet Well Vented with Screen Fillets in Wet Well Check Valves and Gate Valves Security Fencing Lockable Wet Well Cover Area Light 110V Electrical Convenience Outlet Flood/Buoyancy Protection High Water Alarm x Audible and Visual PWC-Mobile Generator Unit x i itttrttt,4::** CA(lth fib"x °..° /ti •'. x x .. •`� ; SEAL 111‘ N 's x 14368 : i x Autosi aA;�;t 11. Summary of force main (by diameter size and pipe material): Diameter Length Pipe (Inches) (Linear Ft) Material PVC 6 2875 SRD21 High Low Minimum Elevation Elevation Velocity(fps) 205 186 2.31 Maximum Vcl.(fps) 2.31 Minimum Cover (in) 36 12. Are air release valves provided at all high points along thc force main (must be provided where the elevation difference exceeds 10 feet)? x yes — no 13. Is pump station subject to flooding? yes x no. If yes, what measures arc being takcn to protect against flooding? 14. If subject to flooding, specify the 100-year flood elevation: N/A Feet MSL 15. Arc thcrc existing or planned pump stations •nstream of this station? ycs X no If yes, the engineer shall evaluate thc abilit; uL those pump stations to adequately handle the subject flows. GRAVITY SEWER EXTENSION AND PUMP STATION PAGE 6 (4/91) TO: REGIONAL WATER QUALITY SUPERVISOR Please provide me with the classification of the surface waters identified in number 5 below and on the attached map segment: nK Name of surface waters: r‘r"0.w .N. Y ‘in1/4J } •VIY C'lacsification (as established by the Environmental Management Commission): C, Proposed Classification, if applicable: Signature of regional office personnel: NIA Datc: INSTRUCTIONS TO ENGINEER In order to determine whether provisions for dual or standby power may be required for the subject facility, the classification of the closest downslope surface waters (the surface waters at any overflow from the facility would flow toward) must be determined. You are required to submit this form, with items 1 through 10 completed, to the appropriate Division of Environmental Management Regional Water Quality Supervisor (see attached listing). At a minimum, you must include an 8.5" by 11" copy of the portion of a 7.5 minute USGS Topographic Map which shows the subject surface waters. You must identify the location of the facility and the closest downslope surface waters (waters for which you are requesting the classification) on the submitted reap copy. The application may not be submitted until this form is completed and included with the submittal. 1. Applicant (corporation, individual, or other ): Public Works Commission 2. Name and Complete Address of Engineering Firm: PWC-Water/Sanitary Sewer System Engineering Division State: North Carolina Zip: 28301 City: Fayetteville Telephone No. (919) 483-140I Ekfa+495 Victor Ganjehsani. P.E_ 3. ' Project Namc: Ridgewood Development pin-38 GPM 4. Pump station design flow: 54360 GPD; PR= 200GPM GPM 5. Name of closest downslope surface waters: 6. County(s) where project and surface waters•arc located: Cumberland 7. Map name and date: See attached map 8. North Carolina Professional Engineer's Registration No. 14368 9. Print Name of Engineer Victor Ganjehsani 10. Scal and Signature (specify date): 6 of 10 DIVISION OF ENVIRONMENTAL MANAGEMENT REGIONAL OFFICES (4/91) Asheville Regional WQ Super. 59 Woodfin Place Asheville, NC 28802 704/251-6208 Avery Buncombe Budge Caldwell Cherokee Clay Graham Haywocd Henderson Jackson Macon Madison McDowell Mitchell Polk Rutherford Swain Transylvania . Yancy Fayetteville Regional WQ Super. Wachovia Building, Suite 714 Fayetteville, NC 28301 919/486-1541 Anson Moore Bladen Robeson Cumberland Richmond Harnett Sampson Hoke Scotland Montgomery Winston-Salem Regional WQ Super. 8025 North Point Boulevard. Suite 100 Winston-Salem, NC 27106 919/761-2351 Alamaunce Rockingham Alleghany Randolph Ashc Stokes Caswell Surry Davidson Watauga Davie Wilkes Forsyth Yadkin Guilford Washington Regional WQ Super. P O Box 1507 Washington, NC 27889 919/946 6481 Beaufort Jones Batie Lenoir Camden Martin Chowan Pamlico Craven Pasquotank Currituck Pe quimans Dace Pitt Gates Tyre!' Grease Washington Hatford Wayne Hyde Mooresville Regional WQ Super. 919 North Main Street Mooresville. NC 28115 704/663-1699 Alexander Cabaurus Catawba . Gaston Iur dell Lincoln Mecklenburg Rowan Stanly Union Cleveland Raleigh Regional WQ Super. 3800 'Barrett Dr., Suite 101 Raleigh, NC 27609 919/733-2314 Chatham Nash Durham Northampton Edgecombe Orange Franklin Person Granville Vance Halifax Wake Johnston Warren Lee Wilson Wilmington Region. WQ Super. 127 Cardinal Drive Extension Wilmington, NC 28405-3845 919/395-3900 Brunswick Carteret Columbus Duplin New Hanover Onslow Petider 7 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 8 (4/91) THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required Items a. One original and three copies of the completed and appropriately executed application form. b. Three sus of detailed plans and specifications signed and scaled by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, details on the pump station, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the first page of the specifications must be signed and sealed. Three copies of the existing permit if a renewal or modification. c. Three copies of all calculations, including pump selection, friction calculations, cycle time, pump curves (including system curves applicable with one pump running, two pumps running, three pumps running, etc.), and evaluation of downstream pump stations. These items must be submitted under the signature and seal of the North Carolina Professional Engineer. d. The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5). e. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. f. An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. 8 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 9 (4/91) Name and Complete Address of Engineering Firm: Post Office Box 53774 Moorman, Kizer & Reitzel, Inc. City: Fayetteville Telephone No. (919) 484-5191 State: NC Zip: 28305 Professional Engineer's Certification: James M. Kizer , attest that this application for Ridge Wood Subdivision has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Registration No. Print Name of Engineer James M. Kizer .�.0H CAR°C.,• ' Seal and Signature (specify dat 4783 Applicant's Certification: j, Timothy Wood Ridge Wood Subdivision V ��'•.�FS M . ‘(\ , attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this appiication package will be returned as incomplete. • Signature Date THE COMPLETED APPLICATION PACKAGE, INCLUD!A'G ALL SUP ORT NG INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE, NUMBER: 919/733-5083 GRAVITY SEWER EXTENSION & PUMP STATION :. PAGE 10 (4191) PERMIT APPLICATION !PROCESSING FEES (effective October 1,1990) CATEGORY NEW APPLICATIONS/ RENEWALS WITHOUT MODIFICATIONS MODIFICATIONS > 1,000,000 GPD Industrial Domestic/Cooling Water 10,001 - 1,000,000 GPD Industrial Domestic/Cooling Water $400 $400 $300 $300 $250 $250 1,001 -.10,000 GPD Industrial . $400 $200 Domestic/Cooling Water $400 $200 < or = 1,000 GPD and Single Family Dwelling Sludge < or = 300 Acres . Sludge > 300 Acres $240 $120 $400 $400 $250 $250 Sewer Extensions (nondclegated) $400 0 Sewer Extensions (delegated) $200 0 Closed -Loop Recycle or Evaporative $400 $200 NOTE: The Fees for Soil Remediation Projects are the same as for Sludges. Under the Sewer Extension Fee, "delegated to municipalities" applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the Division of Environmental Management. 10 of 10 42 • e • ,,, be C. tiF ...... , .RQ 646 woo ,vrfw,OR—Gf OLOG•C.. Su4v(� 4fS�Ov vow O,991 681 6820DO^ ROAD CLASSIFICATION Tower 79 ')0 Mapped by the Army Map Service Published for civil use by the GP(llnPlral Ci n,nv .-. 683 684 • Delegated Municipality Reviewer's NC !'recessional Eneincer's Regisrration Seal and Signature (specify date): FCIRM- nn,rr-c f/r State of North Carolina Department of Environment. Health, and Natural Resources Division of Environmental Management 512 North Salisbury Svicet . Raleigh. North Carotin:: 27626-tti James G. Marun, Govcmor William W. Coney, Jr.. Secre;ary Memorandum To: Delegated Municipalities From: Steve W. Tedde, Chief Water Quality Section k) May 1, 1991 Subject: Delegated Munic paiit;es Che.::iist for Revised Non -Discharge Pentut .AppitCat: ,,t:, The Division of Environmental Management's Water Quality Section has revised the Gravity Sewer Non -Discharge Permit Application Form. The`form now incorporates the bast.: information that the Division feels is necessary in order for the delegated municipalities to perform :; review on a gravity sewer project for the Division; therefore: the Division will no loner require the "Delegated Municipalities Gravity Sewer Design Checklist" be completed and stthmt:.ed. however, require that the delegated municipality perform the same type of review as always requir-:d and complete the bottom portion of this page and attach it as the last page of, a!! Travity sekve- applications that are being submitted as a delegated municipalities project. If you Piave any question:, on this matter, please contact Mr. Randy Jones at 919/733-5083. DELEGATED MUNICIPLITY GRAVITY SEWER CERTIFff= (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) Applicant: PUBLIC WORKS COMMISSION CITY OF FAYETTEVILLE N.C. Project Name: RIDGE WOOD SUBDIVISION Delegated Municipality Reviewer's Certification: VICIUR GANJEHSANI , attest that the subject plans and specifications have been reviewed under my supervision and that those plans and specifications are consistent with the information that has been specified on the Non -Discharge Application and the Division of Environmental Management's minimum design requirements for gravity sewer p •jef�/%