Loading...
HomeMy WebLinkAboutWQ0038322_Application (FTSE)_20210628Permit Number WQ0038322 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRuIe Permitted Flow 11,300 Facility Name Hampton Inn Stump Sound Private Pump Station and Sewer Location Address Owner Owner Name Sneads Ferry Ventures LLC Central Files: APS _ SWP 6/8/2021 Permit Tracking Slip Status Project Type In review Major modification Version Permit Classification 6 Individual Permit Contact Affiliation MajorlMinor Region Minor Wilmington County Onslow Facility Contact Affiliation Owner Type Non -Government Owner Affiliation John Sandlin 107 Stokely Rd #100 Dates/Events Wilmington p / NC 28403 Scheduled Ong Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 3/1/2016 6/1/2021 RECEIVED JOHN L. PIERCE & ASSOCIATES, P.A. LAND SURVEYING — LAND PLANNING — MAPPING P.O. BOX 1685 JACKSONVILLE, NC 28541 OFFICE: (910) 346-9800 FAX: (910) 346-1210 E-MAIL: bettvb .ilono.com Or brian'AlIpnc.com TO: Dean Hunkele N.C. Department of Environment And Natural Resources 127 Cardinal Drive Extension Wilmington, NC 28405 DATE: 05/25/2021 ATTENTION: Dean Hunkele Re: Beachside Commons JUN 01 2021 NCDEQ 'iNILMINGTON RO Letter of Transmittal COPIES DATE NUMBER DESCRIPTION 2 Fast -Track Applications for Sewer/with Street view map & Quad Ma I Check in the amount of $480.00 2 Sealed calculations I Sewer System Permit Ownership/ Name Change Form` Sewer System Narrative SIGNED: BETTY BULLOCK Division of Water Resources State of North Carolina Department of Environnienta l Quality Division of Water Resources I SA NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 S SUPPORTING DOCUMENTATION Application Number: (to be completed by DWIt) All items must be contnleted or the application will be returned 1. APPLICANT IN'FORMA'1'ION: 1. Applicant's name: Pluris .LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporalion ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ Stale/County ❑ Municipal ❑ Other 3. Signature authority's name: Randy Hoffer per 15A NCAC 02T 0106(b) Title: Regional Manager 4. Applicant's mailing address: 1095 NC I lwy10 City: Sneads Ferry State: NC Zip: 28460-_ 5. Applicant's contact information: Phone number: (888) 758-7471 Email Address: rhoffei-@plurisusa cons II. PROJECT INFORMATION: 1. Project name: L3eachside Commons Townhontes R L3eachside Plaza `7 06.0393a4 3— l- 2. Application/Project status: Proposed (New Permit) Existing Permit/Profe"- q'c-13 et Ira modification, provide the existing permit number: W000_ and issued date: _ If new construction but part of a master plan, provide the existing permit number: WQ00_ 3. County where project is located: Onslow 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.31.7T Longitude:-77.26..08' 5. Parcel ID (if applicable): 160772 (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: Professional Engineer: David K. Newsom License Number: IS 148 Firm: Crystal Coast Engineering PA Mailing address: 205-3 Ward Road City: Swansboro State: NC Zip: 28584 Phone number: 910) 325-0006 Ernail Address: crystalcoaslene(albizec.rr eom IV. WASTEWATER TREATMENT FACILITY (W WTF) INFORMATION: Facility Name: Pluris Sneads Ferry WW'I'I' Permit Number: W00005849 Owner Name: Pluris LLC V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. PermitNumber(s): WQW00038322 System Wide Collection System Permit Number(s) (irapplicable): WQCS00275 Owner Name(s): Sneads Perry Ventures. LLC / Pluris 1 LC FORM: FTTA 04-16 Page I of VL GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association has an Onerational Agreement (FORM: HOA) been attached? ❑ Yes ❑N'o ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ® Retail (stores, centers, malls) ❑ Car Wash ® Residential Leased ® Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ® Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nalurc of wastewater : 100 % Domestic/Commercial % Commercial _ % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .01 14(fl? ®Yes ❑ No If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(t)) Daily Design Flow 0' No. of Units Flow 2 bedroom dwelling unit 160 gal/unit 84 ca 13,440 GPD 3 bedroom dwelling unit 240 galhmit 16 ca 3,840 GPD Stores/centers w/o food servic 100 gal/1000 sf 10,510 sf 1,051 GPD Shop Center w/ food service 130 gal/l000 sf 6,985 sf 908 GPD Fitness Center 50 gal/100 sf 720 sf 360 GPD Clubhouse/Pool 10 gal/person 16 persons 160 GPD Total 19,759 GPD a See 15A NCAC 02T .0114(b). (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential developpnent uses; public access facilities located near high public use areas; and residential property located south or cast of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 021'.0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 14) shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: Iy GPD (per 15A NCAC 02T .01 14) ➢ Do not include future flows or previously permitted allocations Ifpennitled flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new now expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VI1. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 1764.35 PVC/DIP > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (If Applicable)-02T.0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: _ 2. Approximate Coordinates (Decimal Degrees): Latitude: 0Longitude: - 3. Design flow of the pump station: _ millions gallons per day (firm capacity) 4. Operational point(s) of the puntp(s): _ gallons per minute at feel total dynamic head (TDI1) 5. Summarize the force stain to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T.0305(h)(1): ❑ Standby power source or pump with automatic activation and teIentcny - 15A NCAC 021' .0305(h)(1)(13): > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Most be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel tintefrantes, shall be provided in the case of a multiple station power outage. FORM: PTA 04-16 Page 3 of 5 IX. SETBACKS &cSEPARATIONS —(02B.0200&15ANCAC 021'.0305(Q): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) &s (e) D 15A NCAC 02T.0305 I contains minimum separations that shall be provided for sewer systems: ❑ Yes ❑ No Setback Parameter* Separation Required Stonn sewers and other utilities not listed below (vertical) 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class It impounded reservoirs used as a source ordrinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches D 15A NCAC 02T 0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. D **Stream classifications can be identified using the Division's NC Surface Water Classifications weboaoe ➢ If noncompliance with 02T.0305(fi or (e), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes [-]No D See the Division's draft separation requirements for situations where separation cannot be meet D No variance is required if the alternative design criteria specified is utilized in design and consuvction `r As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No D This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No D Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters D Information can be obtained from the 401 R Buffer Pemtittine Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02'L0105(c)(6), directly related environmental permits or certification applications arc being prepared, have been applied for, or have been obtained. Issuance of this pennit is contingent on issuance of dependent permits (erosion and sedimentation control plans, slornnvater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer' nncans "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to slreambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No D If yes, include an allachmcnt with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permillee or its representative at least once every six -mouths and inspections documented per 15A NCAC 02T.0403(a)(5) or the perntitec's individual System -Wide Collection pernilt. FORM: FTA 04-16 Page 4 of I:�i7slTt II IITaL[�L�iJi(�I�YI 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ❑ Yes ❑ No If No, complete and submit the Variance/Altemative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: that this application for (Professional Engineer's name Trom Application Item III.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation,,, A ation for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: ✓ a%< Date: s� Z FORM: FTA 04-16 Page 5 of 5 Division of water Resources Entity Requesting Allocation: Pluris LLC State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Project Name for which flow is being requested: Beachside Commons TH & Plaza More than one FTSE maybe required for a single project if lite owner of the WWTP is not responsible for ali pump stations along the route of the proposed wastewaterflow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Pluris North Topsail WWTP b. WWTP Facility Permit #: WQ0005849 AlI lows are in MGD c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 1.542 0.12546 0.72600 0.019759 0.871819 56 % II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station (Name or Permit Number) No. (A) (B) Design Average Approx. Daily Current Firm Flow** Avg. Daily Capacity, * (Firm / pf), Flow, MGD MGD MGD (C) (D)=(B+C) (E)=(A-D) Obligated, Not Yet Total Current Tributary Flow Plus Daily Flow, Obligated MGD Flow PS 108 WQ0038322 0.181 0.0725 0.011 0 0.0625 Available Capacity*** 0.0625 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pt) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is <0. Downstream Facility Name (Sewer): _North Topsail South Consolidation Downstream Permit Number: WQ0034485 Page 1 of 6 FTSE 10-18 III. Certification Statement: I Randy Hoffer certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Page 2 of 6 FTSE 10-18 State of North Carolina �, DAIDepartment of Environmental Quality Division of Water Resources AMW V V i ML SEWER SYSTEM PERMIT OWNERSHIP/NAME CHANGE Division of Water Resources INSTRUCTIONS FOR FORM: PNOCF 01.16 I. EXISTING PERMITTEE INFORMATION: 1. Permittee's name: Sneads Ferry Ventures, LLC 2. Signature authority's name: John Sandlin per 15A NCAC 02T .0106(b) 3. Signature authority's title: Member/Manager 4. Permittee's mailing address: 107 Stokley Road #100 City: Wilmington State: NC Zip: 28403 5. Permittee's contact information: Phone number: (910) 256-2672 Fax Number (_) __-n/a Email Address: barry@crownhoteltm.com II. APPLICANT INFORMATION: 1. Applicant's name: Pluris. LLC 2. Signature authority's name: Randy Hoffer per 15A NCAC 02T .0106(b) 3. Signature authority's title: Regional Manager 4. Applicant's mailing address: 1095 Highway 210 City: Sneads Ferry State: NC Zip: 28460-_ 5. Applicant's contact information: Phone number: (888) 758-7471 Fax Number (_) _ n/a Email Address: rhoffer@plurisusa.com 6. Representative's name: Randy Hoffer 7. Representative's title: Regional Manager 8. Representative's contact information Phone number: (888) 758-7471 Fax Number (_) = n/a Email Address: rhoffer@plurisusa.com III, PERMIT INFORMATION: 1. Existing permit number: W00038322 and most recent issuance date: March 1, 2016 2. Reason for the permit application: Change of Ownership If other, attach detailed explanation 3. Has the facility been constructed? ® Yes or ❑ No 4. Has the facility been certified per 15A NCAC 02T .0116? ® Yes or ❑ No FORM: PNOCF 01-16 Page 1 of 2 IV. CERTIFICATIONS: Existing Permittee's t erkficiltion per that this application (Signature Authority's name & title from Application Item 1.2 & 3) has been reviewed by me ahj is accurate and complete to the best of my knowledge. I understand that prior to reissuance of the permit into the Applicant's name, I will continue to be responsible for compliance with the current permit and any discharge of wastewater from this system to surface waters or the land may result in an enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will also make no claim against the Division of Water Resources should a condition of the existing permit be violated. I also understand that if all required parts of this application are note completed and that if all required supporting information and attachments are not included, this application will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 a we'l^lu y'¢'v'1 p alties up to $25,000 per violation. 1 Signature- ----I �� Date: I �I Applicant's Certification name & title Xom Application Item has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that after issuance of the permit into the Applicant's name, I will be responsible for compliance with the issued permit and any discharge of wastewater from this non - discharge system to surface waters or the land may result in an enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties u to $25,0 b per violation. Signature: Date: FORM: PNOCF 01-16 Page 2 of 2 Sewer System Narrative Beachside Commons Townhomes & Beachside Plaza — Stump Sound Sneads Ferry Ventures, LLC proposes to develop a 15.77 acre tract located on NC Hwy 210, 0.47 miles North of its intersection with NCSR 1518 in Onslow County. The proposed development includes a 100 residential townhome units (2 and 3 bedroom), 17,495 sf retail space and a storage facility, with associated parking & sidewalks. The site is currently undeveloped and contains considerable 404 wetlands along the northern boundary and across the rear. Site topography is generally flat to'gently sloping (0 - 2%). The project site is located in the White Oak basin and drains to an UT of Mill Creek (SA;HQW — 19-39-3-1). The proposed development activities are high density (percent impervious > 12 %); therefore stormwater treatment is required. The proposed development will divert all stormwater to the previously permitted Wet Pond serving the Hampton Inn (SW8 160102) The site was recently rough graded and was erosion control devices (construction entrance, silt fence, diversion ditches/berms and Sediment Basins were installed and are still operational. These existing devices will be supplemented by new silt fence and additional sediment traps where necessary. will be installed to protect adjoining properties from sediment. The development is to be served by 8" gravity sewers connecting to the existing gravity sewers and pump station serving the adjacent Hampton Inn site. That pump station/forcemain is connected to an existing 12" sewer forcemain along NC Hwy. 210 and is owned by PLURIS LLC. Google Earth XMI G,pd, C A �,, 1111111,1 Design Calculations Pump Station Capacity Analysis for Beachside Commons Townhomes & Beachside Plaza located in Stump Sound Township, North Carolina Prepared By: Crystal Coast Engineering, P.A. David K. Newsom, PE 205-3 Ward Road Swansboro, NC 28584 Business License #: C-2553 1. Project Descrintion/Narrative The project consists of capacity evaluation for the existing pumping station which serves the Hampton Inn hotel on NC 210 near its intersection with NCSR 1518 in the Stump Sound Township. The station will continue to serve the 90 room hotel, however will now accommodate a proposed mixed use (townhomes and retail) development on the adjacent vacant tract. The existing pump station is connected to the existing 12" pressure main along NC 210. 2. Flow Project Design In accordance with NCAC 02T.0114, project shall be designed to accommodate a Design Daily Flow as follows: Existing Hotel 90 Rooms @ 120 gpd/room 10,800 gpd 10 employees/ 2 shifts 20 emp. @ 25 gpd/emp 500 gpd Existing Subtotal 11,300 gpd Proposed (Beachside Commons Townhomes & Beachside Plaza 2 bedroom townhome 84 units @ 160 gpd/unit 13,440 gpd 3 bedroom townhome 16 units @ 240 gpd/unit 3,840 gpd Stores w/o food service 100 gpd/1000 sf 1,051 gpd Stores w/ food service 130 gpd/1000 sf 908 gpd Fitness Center 50 gpd/100 sf 360 gpd Clubhouse/Pool 10 gpd/person 160 gpd Proposed Subtotal 19,759 gnd Subtotal Total (Existing + Proposed) 31,059 gpd Future Unspecified 13,941 end GRAND Total (Existing + Proposed + Future) 45,000 gpd 3. Compute Minimum Pum ing Rate Peak Factor = 18 + (P)1/2 / 4 + (P)'n where P = (135 + 284) / 1000 = 0.419 = 4.0 Average Daily Flow = 45,000 gpd Peak Factor = x 4.0 Min. Pump Rate = 180,000 gpd Or 125 gpm (say 126 gpm) Velocitv Check 3" FM 4.6 fps A bit high but OK for wetwell ONLY 4" FM 2.6 fps OK 6"FM 1.16 <2.0-NO Use 4" piping (excl. wetwell) and forcemain 4. Pipe Effective Lengths Effective piping lengths are computed as follows: 4" Valve Vault Piping Actual Length = 22 No. Fitting Type L/D L Total 1 gate valve 35 11.6 11.6 1 check valve 135 45.0 45.0 3 90 bend 20 6.6 20.0 Fitting/Valve Length = 76.6. SubTotal Effective Length = 98.6' 4" Forcemain Pine Actual Length = 1139 No. Fitting Type L/D L Total 3 90 degree bend 20 6.7 20.0 1 45 degree bend 10 3.3 3.3 1 check valve 135 45.0 45.0 Fitting/Valve Length 68.3 SubTotal Effective Length = 1207.3' TOTAL EFFECTIVE LENGTH = 1,306' 5. Choose Pump & Compute Operating Conditions Head losses for each pipe section are computed at various flow rates using Hazen -Williams equation (see attached EPANET Model prepared by others). Most suitable pump appears to be Myers WG75HH (7.5 HP ruin) Operating Condition (Typical Number of simultaneous pumps running) 126 gpm a@ 102' TDH See attached Hydraulic Models for detailed analysis: 6. Compute Pump Cycle Times at ADF Volume per foot of pump chamber = 146.8 gallons a. Fill Time at ADF Fill/Pump Volume = 293.6 gallons Fill Time fill volume /ADF 293.6 gallons/36,620 gpd 0.008 days (11.5 minutes) b. Pump Time at ADF Pump Time = c. Cycle Time at ADF Cycle Time = 6. Emergent Storage See drawings. 7. Flotation See drawings, pump volume / (pump rate — ADF) 293.6/ (126 gpm —25.4 gpm) 2.9 min Fill time + Pump Time 14.4 minutes (OK)