Loading...
HomeMy WebLinkAboutWQ0042628_Application (FTSE)_20210629TOWN OF FRANKLIN 44982 VENDOR 1988 NC DEQ 06/11/2021 44982 DATE INVOICE# PO# DESCRIPTION GL# AMOUNT 6/8/2021 6821 Fast Track Sewer System Extension Application 60-7400-5970 480.00 tun ofJlranWin Provielontor the Payment of t is c eck has been made by an Bpproptletlon duly made,. pursuant to the local Government Budget and Fiscal Control Am PAY TO THE ORDER OF ---Four Hundred Eighty Dollars and 00/100 Cents --- NC DEQ 2090 US Highway 70 Swannanoa, NC 28778 ®shell WELL 1.1 66-162/531 DATE CHECK TOTAL 480.00 NUMBER 44982 AMOUNT 06/11/2021 $480.00 CLERK- \ . 1 e Lt a ith,p TREASURER AS Ste, - MANAGER d� AUTHORIZED SIGNATURE -£�H •e .tlE{T.4AVMil9'IRamTA1101'ffi .. a .. .n bY. E0449820 i:053LEI L6261:2074780035 2770 TOWN OF FRANKLIN VENDOR: 1988 NC DEQ DATE INVOICE# PO# DESCRIPTION 6/8/2021 6821 Fast Track Sewer System Extension Application 06/11/2021 44982 44982 AMOUNT 480.00 ®Safegu LINO Ury so, SF4001 CHECK TOTAL 480.00 TO REORDER. CALL YOUR LOCAL SAFEGUARDOIBIBIBUTOB AT e00-780-7233 CRNFZKC01O O TM6FAIla1 ;% WithersRavenel Our People. Your Success. June 21, 2021 North Carolina Department of Environmental Quality Division of Water Resources 2090 US Highway 70 Swannanoa, NC 28778 Attn: Tim Heim, Engineer RE: WR Project #08210279.00 Fast Track Sewer System Extension Application Town of Franklin Boyd's Pump Station Rehabilitation Dear Mr. Heim: Please find enclosed a Fast Track Application for the Town of Franklin Boyd's Pump Station Rehabilitation Project. The project consists the installation of a new 6' precast wetwell and new submersible pumps with an operating point of 250 GPM @ 79' TDH to replace the existing Boyd Pump Station, which is aging. The project will connect the new pump station to the existing sewer system through the installation of approximately 5 linear feet (LF) of 12-inch DIP gravity sewer and approximately 35 LF of 6-inch DI. The new pump station will be located on the same parcel. No additional flow is requested with this application. Items included in this submittal: • Two copies of Fast Track Sewer System Extension Application • Two copies of USGS and aerial site maps • Application fee If you have any questions about this submittal, please do not hesitate to call me. Sincerely, WithersRavenel Jacob Gray, PE Assistant Project Manager - Utilities WithersRavenel cc: Nathanael Moore, Town of Franklin JUN 2 4 2021 —J Water Quality Regional Operations Asheville Regional Office 84 Croce Avenue, Suite 260 I Asheville NC 28801 t: 828.255.03131 f: 919.467.6008 www.withersravenel.com I License No. C-0832 Asheville I Cary I Greensboro Pittsboro Raleigh I Wilmington DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with 15A NCAC 02T 15A NCAC 02T .0300 Division policies and good engineering practices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be available upon request by the Division. Projects that are deemed permitted (do not require a pennit from the Division) are explained in 15A NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): ➢ Projects that require an environmental assessment in accordance with 15A NCAC IC .0100; ➢ Projects that do not meet any part of the minimum design criteria (MDC) document; ➢ Projects that involve a variance from the requirements of 15A NCAC 2T; ➢ Pressure sewer systems utilizing septic tank -effluent pumps (STEPs) or simplex grinder pumps; ➢ STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); ➢ Vacuum sewer systems. General —When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy of Application and Supporting Documents ® Required unless otherwise noted B. Cover Letter (Required for All Application Packages):.-•- - • IA% C la List all items included in the application package, as well as a brief description of the requested pemStig acttotf. ➢ Be specific as to the system type, number of homes served, flow allocation required, etc. cum r.a ➢ If necessary for clarity, include attachments to the application form. co. O 0 'm m, C. Application Fee (All New and Major Modification Application Packages): �-o m ® Submit a check or money order in the amount of $480.00 dated within 90 days of application submit@Ld ➢ Payable to North Carolina Department of Environmental Quality (NCDEQ) to -C- D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages): ® Submit the completed and appropriately executed application. ➢ If necessary for clarity or due to space restrictions, attachments to the application may be made. ❑ If the Applicant Type in Item I.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. ❑ If the Applicant Type in Item 1.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item 11.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc. la The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. a The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in I5A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 1 of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable): ❑ Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. ➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. S. The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. > Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 143- 215.67(a). > Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x II -inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area and closest surface waters. > Location of the project (gravity sewer, pump stations & force main) > Downstream connection points and permit number (if known) for the receiving sewer ® Include a street level map (aerial) showing general project area so that Division staff can easily locate it in the field. G. Existing Permit (All Modification Packages): ❑ Submit the most recently issued existing permit. ❑ Provide a list of any items within the permit the Applicant would like the Division to address during the permit modification (i.e., permit description, flow allocation, treatment facility, etc.). H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per 15A NCAC 02T .0305(h)(I), submit documentation of power reliability for pumping stations. S. This alternative is only available for average daily flows less than 15,000 gallons per day ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(6)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per I5A NCAC 02T .0115(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Home/Property Owners' Associations ❑ Per 15A NCAC 02T .0115(c), submit the properly executed Operational Agreement (FORM: HOA). ❑ Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ❑ Developers of lots to be sold ❑ Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement (FORM: DEV). For •Wore inr • nation, ' ..it the Division-'s-collectionsys INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE• REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax Water Quality Section Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville, North Carolina 28301-5094 (910) 433-3300 (910) 486-0707 Fax Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Water Quality Section Mooresville Regional Office 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Water Quality Section Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27899-1628 (919) 791-4200 (919) 788-7159 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Water Quality Section Washington Regional Office 943 Washington Square Mall Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Water Quality Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Water Quality Section Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolina 27105 (336) 776-9800 Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin Water Quality Section INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of 3 DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Town of Franklin (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership 0 Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: Justin Setser per 15A NCAC 02T .0106(b) Title: Interim Town Manager 4. Applicant's mailing address: PO Box 1479 City: Franklin State: NC Zip: 28744- 5. Applicant's contact information: Phone number: (828) 524-2516 Email Address: Isetser(a)franklinnc.com ❑ Other II. PROJECT INFORMATION: 1. Project name: Boyd's Pump Station Rehabilitation 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project Ifa modification, provide the existing permit number: W000 and issued date: If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Macon 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.1329° Longitude: -83.3961° 5. Parcel ID (if applicable): 6583621305 (or Parcel ID to closest downstream sewer) ID. CONSULTANT INFORMATION: 1. Professional Engineer: Jacob Gray License Number: 047761 Firm: WithersRavenel Mailing address: 84 Coxe Avenue. Suite 260 City: Asheville State: NC Zip: 28801- Phone number: (828) 255-0313 Email Address: jgray@withersravenel.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Town of Franklin Wastewater Treatment Plant Permit Number: NC0021547 Owner Name: Town of Franklin V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS L If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ENo ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ENo ®N/A 3. If the Applicant is a Home/Property Owners' Association has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ENo ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ® Residential Leased ❑ School / preschool / day care ❑ Food and drink facilities ® Businesses / offices / factories • Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100% Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) I —Hs there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under l5A NCAC 02T .0114(1)? ❑ Yes ® No > If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114W) Daily Design Flow a'b No. of Units Flow No new flow generated by project gal/ GPD Rehab of existing pump station gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 02T .0114(6), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per I5A NCAC 02T .0114(c), design flow rates for establishments not identified [in table I5A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) > Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ® Other (Explain): Rehabilitation or replacement of existing pump station with no new flow expected FORM: ETA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA(IfApplicable)- 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 12 5 DI ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information rela ed to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable)— 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT L Pump station number or name: Boyd's Pump Station 2. Approximate Coordinates (Decimal Degrees): Latitude: 35.1329° Longitude: -83.3961° 3. Design flow of the pump station: 0.035 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 250 gallons per minute at 79 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6 - 35 DI 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B); > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(t)(C): > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) anis comps n. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS— (02B .0200 & 15A NCAC 02T .0305(0): I. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) > 15A NCAC 02T.0305(t) contains minimum separations that shall be provided for sewer vstems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HOW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(t) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (g) see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes 0 No ❑ N/A > See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per I5A NCAC 02B .0200? ® Yes ❑ No ❑ N/A > This would include Trout Buffered Streams per I5A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? ) Information can be obtained from the 401 & Buffer Permitting Branch E Yes ® No 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402 "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned-parallelto-streambanks{hat-issubject to erosinn3hatundetminesertleter-ioratesthes ❑ Yes ® No ❑ N/A > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A.NCAC 02'1' the Mininmin Design Critefia fig the Permuting of PUMP Stations One Form Mains (latest version) and the Gravity Sewer Minirmml Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Anorovnl of Ike rawest is renulretlnrbr to submittal oldie East Track Aminealion and snnna4ng documents 2. Professional Engineer'sCertification: 1, Sat cob ( was// (Professional $ngineer's name from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the piths, specifications, engineering calculations, and all other suppoting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, sty person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $I0,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: S�N CAIRO10 ( :0. :22 p47 fi' a-.1 'i 410G1t,' -� 3. Applicant's Certification per ISA NCAC 02T .0106(h): attest that this application for 1o6+ 1 .S cT5er Z'n-/et7wi Town i-fQ4f(ger attest that this application For (Signature Authority's none & title from Application Item 1.3.) J has been reviewed by me and is accurate and complete to the best of my knowledge. I onderstond that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater front this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal ptnsecution. [will make no claim against the Division of Water Resources should a condition or this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be rettuned to me as incomplete. NOTE - In accordance with General Salutes 143.215.6A and 143-215.6B, any person who knowingly makes any False statement, representation, or certification in any application package shall he guilty of a Class 2 misdemeanor, which may Delude a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature:. Date 502 FORM: FTA 04-16 Page 5 oF5 c n 3 v 0 a o ha s 3