Loading...
HomeMy WebLinkAboutNC0004952_permit modification_20010507State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross, Jr., Secretary Kerr T. Stevens, Director May 7, 2001 Pem Carter Ticona Shelby Plant Highway 198 Shelby, North Carolina 28152 ATA NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: NPDES Permit Modification Shelby Facility Permit Number NC0004952 CNA Holdings, Inc. Cleveland County Dear Ms. Carter: Please find enclosed the revised Effluent Limitations page. The revised page should be inserted into your permit. The old page may then be discarded. All other terms and conditions contained in the original permit remain unchanged and in full effect. This permit modification is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U. S. Environmental Protection Agency. If any parts, measurement frequencies or sampling requirements contained in this permit modification are unacceptable to you, you have the right toan adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be a written petition conforming to Chapter 150E of the North Carolina General Statutes, filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. If you have any questions concerning this permit modification, please contact Michael Myers at (919) 733- 5083, extension 508. cc: Central Files Mooresville Regional Office, Water Quality Section Point Source Compliance Enforcement Unit NPDES Unit 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 An Equal Opportunity Affirmative Action Employer Telephone (919) 733-5083 FAX (919) 733-0719 VISIT US ON THE INTERNET @ http://h2o.enr.state.nc.us/NPDES A (1). EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS - FINAL Permit No. NC0004952 During the period beginning on the effective date of the permit and lasting until expiration, the Permittee is authorized to discharge from outfall(s) serial number 001- Wastewater Treatment Plant Effluent. Such discharges shall be limited and monitored by the Permittee as specified below: EFFLUENT -CHARACTERISTICS flow (MGD) DISCHARGE LIMITATIONS Monthly Average 1130D, 5-day, 20°C 1 otal Suspended Residue Fecal Coliform (geometric mean) Oil and Grease Total Copper Total Phosphorus Total Nitrogen (NO2+NO3+TKN) Chronic 1 oxicity- Pollutant Analysis' pH' 0.800 Daily Maximum .Weeasureiiiet # Frequency MONITORING REQUIREMENTS 83.0 lbs/day 135.0 lbs/day 200 f 100 ml 203.0 l bs/day 380.0 lbs/day 400 / 100 m1 Continuous Daily Daily Weekly Quarterly Monthly Semi -Annually Semi -Annually Quarterly Daily Sample Type Recording Composite Composite Grab Grab Composite Composite Composite Composite Grab NOTES: Sample Locations: E — Effluent. 2 Chronic Toxicity (Ceriodaphnia) P/F @ 5.8%; March, June, September, December; See condition A(3) of the Supplement to Effluent Limitations and Monitoring page. 3 The priority pollutant analysis shall be conducted during the month prior to submittal of the permit renewal application; See condition A(4) of the Supplement to Effluent Limitations and Monitoring page. 4 The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units and shall be monitored daily at the effluent by grab sample. The effluent pH of the wastewater is defined and limited at a point between the final clarifiers and final polishing ponjl, such a point being after the combination of all potential influents to the polishing pond. If the pH of the effluent from the polishing pond exceeds 9.0, there will be no effluent violation if the wastewater from the final clarifier has not exceeded 9.0 during the thirty (30) days preceding the measurements of the pH above 9.0 at the effluent from the polishing pond. The pH of the wastewater from the clarifiers and the pH of the effluent from the polishing ponds (final discharge) will be monitored by continuous recorder. Upstream and downstream monitoring shall be conducted weekly in any week the pH of the effluent from the polishing pond is outside the 6.0-9.0 range. THERE SHALL BE NO DISCHARGE OF FLOATING SOLIDS OR VISIBLE FOAM IN OTHER THAN TRACE AMOUNTS. Location1 E E E E E E E E E E E 'Kona CERTIFIED MAIL 7099 3220 0010 6819 0425 Return Receipt to PEM Carter March 29, 2001 PEMC01:09 NCDENR Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Attention: Mr. Michael Myers 1 N3Tl'��9 30�'t!fS 1#1N�d �lTiOi1 kli t i?3� . � � ` Ticona tOOZ — thatl , \\ a s \._ " ; % Shelby Plant �; Highwayy, 198 '',,'1 ' ‘---------: --- '" "� ShelbNC 28152 1Ju � Telephone (704) 480-4700 Reference: CNA Holding Inc — Ticona NPDES Permit Number NC0004952 Shelby, North Carolina As we discussed over the phone today, CNA Holding Inc- Ticona under the Authorization to Construct (ATC) No. 004952ACB addressed the TSS limitations with the installation of a tertiary filtration system. The intent of this installation was to ensure full compliance with the TSS discharge limitations throughout the year without difficulty during the warmer months. Now with this filtration system in full operation, Ticona requests a minor modification to Permit No. NC0004952, to revert back to the original effluent point. Ticona request the removal of the sampling location from the secondary clarifiers during the months of May, June, July and August. CNA Holding Inc — Ticona is committed to ensuring compliance with all County, State, and Federal regulations. Should there be a need for further discussion pertaining to this request, feel free to call me at 704/480-4900, or via email at pem.carter@ticona.com. Sincerely, 91K PEM Carter Sr. Environmental Engineer Celanese Ticona A business of Celanese AG