Loading...
HomeMy WebLinkAboutNC0020737_Inspection_20210615ROY COOPER. Governor JOHN NICHOLSON Interim Secretary S. DANIEL SMITH Director Rick Duncan, Water Resources Director City of Kings Mountain Post Office Box 429 Kings Mountain, NC 28086 Dear Mr. Duncan: NORTH CAROLINA Environmental Quality June 15, 2021 SUBJECT: Pretreatment Compliance Inspection City of Kings Mountain NPDES Permit No. NC0020737 Cleveland County Enclosed is a copy of the Pretreatment Compliance Inspection report for the inspection of the Town of Mooresville's approved Industrial Pretreatment Program on June 8, 2021, by Mr. Wes Bell of this Office The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192 or via email at wes.bell@ncdenr.gov. Enclosure: Inspection Report RE NORTH CAROLINA Sincerely, DocuSigned by: L4iI4tW11 P4f 14 F161 FB69A2D84A3... fo r W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality I Division of Water Resources Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704.663.1699 Deparlmont of Environmental Duatlly NORTH CAROLINA DIVISION OF WATER RESOURCES PRETREATMENT COMPLIANCE INSPECTION (PCI) REPORT BACKGROUND INFORMATION: 1. Control Authority (POTW) Name: City of Kings Mountain 2. Control Authority Representative(s): Richelle Meek, Jason Davis 3. Title(s): WWTP Superintendent, Pretreatment Coordinator 4. Last Inspection Date: 1/14/2020 Inspection Type: ® PCI ❑ Audit 5. Has Program Completed All Requirements from the Previous Inspection and Program Info Sheet(s)? ® YES ❑ NO 6. Is POTW under an Order That Includes Pretreatment Conditions? ❑ YES ® NO Order Type, Number, Parameters: Are Milestone Dates Being Met? ❑ YES ❑ NO ® NA ICIS CODING Main Program Permit Number NC0020737 MM/DD/YY 06/08/21 7. Current Number Of Significant Industrial Users (SIUs)? 7 8. Number of SIUs With No IUP, or With an Expired IUP? 0 9. Number of SIUs Not Inspected By POTW in the Last Calendar Year? 0 10. Number of SIUs Not Sampled By POTW in the Last Calendar Year? 0 11. Number of SIUs In SNC For Limits Violations During Either of the Last 2 Semi -Annual Periods 1 12. Number of SIUs in SNC For Reporting During Either of the Last 2 Semi -Annual Periods 1 13. Number of SIUs in SNC with Pretreatment Schedule? 0 14. Number of SIUs on Schedules? 1 15. Current Number of Categorical Industrial Users (CIUs)? 7 16. Number CIUs in SNC? 2 POTW INTERVIEW 17. Since the Last PCI, has the POTW had any NPDES Limits Violations? If Yes, What are the Parameters and How are these Problems Being Addressed? 18. Since the Last PCI, has the POTW had any Problems Related to an Industrial Discharge (Interference, Pass -Through, Blockage, Citizens' Complaints, Increased Sludge Production, Etc.)? If Yes, How are these Problems Being Addressed? 19. Which Industries have been in SNC for Limits or Reporting during either of the Last 2 Semi -Annual Periods? Not Been Published for Public Notice?(May refer to PAR if Excessive SIUs in SNC) SNC for SNC for Systems Not Pul 20. Which Industries are on Compliance Schedules or Orders? For all SIUs on an Order, Has a Signed Copy of the Order been sent to the Division? 21. Are Any Permits Or Civil Penalties Currently Under Adjudication? If Yes, Which Ones? ❑ YES /1 NO ❑ YES A NO Limits: KMI (January —June 2020) Reporting: CVG-Mayflower Vehicle (January — June 2020) )lished: None KMI, yes ❑ YES aO LTMP/STMP FILE REVIEW: 22. Is LTMP/STMP Monitoring Being Conducted at Appropriate Locations and Frequencies? ® YES ❑ NO 23. Are Correct Detection Levels being used for all LTMP/STMP Monitoring? ® YES ❑ NO 24. Is LTMP/STMP Data Maintained in a Table or Equivalent? ® YES ❑ NO Is Table Adequate? ® YES ❑ NO 25. All LTMP/STMP effluent data reported on Discharge Monitoring Report? ® YES ❑ NO 26. If NO to 23 - 26, list violations: 27. Should any Pollutants of Concern be Eliminated from or Added to LTMP/STMP? ❑ YES ® NO If yes, which ones? Eliminated: Added: NC DWR Pretreatment Compliance Inspection (PCI) Form Updated 7/25/07 Page 1 28. PRETREATMENT PROGRAM ELEMENTS REVIEW: Program Element NC0020737 Last Submittal Received Date In file? Last Approval Date In file Date Next Due, If Applicable Headworks Analysis (HWA) 8/28/2020 a Yes ❑ No 4/21/2016 /1 Yes ❑ No In review Industrial Waste Survey (IWS) 11/27/2019 a Yes ❑ No 3/4/2020 /1 Yes ❑ No 12/1/2024 Sewer Use Ordinance (SUO) 8/9/2013 0 Yes ❑ No 8/16/2013 /1 Yes ❑ No Enforcement Response Plan (ERP) 1/14/2020 a Yes ❑ No 2/5/2020 /1 Yes ❑ No Long Term Monitoring Plan (LTMP) 5/4/2020 a Yes ❑ No 7/31/2020 /1 Yes ❑ No INDUSTRIAL USER PERMIT (IUP) FILE REVIEW: 29. User Name 1. Cormetech 2. KMI 3. CVG 30. IUP Number 032 031 026 31. Does File Contain Current Permit? /1 Yes ❑ No /1 Yes ❑ No /1 Yes ❑ No 32. Permit Expiration Date 7/18/21 6/15/25 8/25/21 33. Categorical Standard Applied (I.E. 40 CFR, Etc.) Or N/A 433 433 433 34. Does File Contain Permit Application Completed Within One Year Prior to Permit Issue Date? /1 Yes ❑ No a Yes ❑ No L Yes ❑ No 35. Does File Contain an Inspection Completed Within Last Calendar Year? /1 Yes ❑ No /1 Yes ❑ No r Yes ❑ No 36. a. Does the File Contain a Slug/Spill Control Plan? b. If No, is One Needed? (See Inspection Form from POTW) a. AYes •No b. •Yes •No a. ►Yes No b. •Yes •No a. IYes •No b. •Yes •No 37. For 40 CFR 413 and 433 TTO Certification, Does File Contain a Toxic Organic Management Plan (TOMP)? ®Yes❑No❑N/A ®Yes❑No❑N/A ®Yes❑No❑N/A 38. a. Does File Contain Original Permit Review Letter from the Division? b. All Issues Resolved? a. AYes •No b.❑Yes❑NoEN/A a. ► Yes •No b.❑Yes❑No®N/A a. AYes •No b.❑Yes❑NoEN/A 39. During the Most Recent Semi -Annual Period, Did the POTW Complete its Sampling as Required by IUP, including flow? ►/ Yes ❑ No /1 Yes ❑ No r Yes ❑ No 40. Does File Contain POTW Sampling Chain -Of -Custody Forms? /1 Yes ❑ No /1 Yes ❑ No L Yes ❑ No 41 a. During the Most Recent Semi -Annual Period, Did the SIU Complete its Sampling as Required by IUP, including flow? ®Yes❑No❑N/A ®Yes❑No❑N/A ®Yes❑No❑N/A 41b. During the Most Recent Semi -Annual Period, Did SIU submit all reports on time? ® Yes ❑No❑N/A NYes❑No❑N/A ® Yes ❑No❑N/A 42a. For categorical IUs with Combined Wastestream Formula (CWF), does file include process/dilution flows as Required by IUP? ❑Yes❑NoEN/A ❑Yes❑NoEN/A ❑Yes❑NoEN/A 42b. For categorical IUs with Production based limits, does file include production rates and/or flows as Required by IUP? ❑Yes❑NoEN/A ❑Yes❑NoEN/A ❑Yes❑NoEN/A 43a. During the Most Recent Semi -Annual Period, Did the POTW Identify All Limits Non -Compliance from Both POTW and SIU Sampling? ®Yes❑No❑N/A ®Yes❑No❑N/A ■ Yes •No@NA 43b. During the Most Recent Semi -Annual Period, Did the POTW Identify All Reporting Non -Compliance from SIU Sampling? ❑Yes❑NoEN/A ❑Yes❑NoEN/A ❑Yes❑NoEN/A 44. a. Was the POTW Notified by SIU (Within 24 Hours) of All Self- Monitoring Violations? b. Did Industry Resample and submit results to POTW Within 30 Days? c. Did POTW resample within 30 days of knowledge of SIU limit violations from the POTW sample event? a.❑Yes❑NoEN/A b.❑Yes❑NoEN/A c.❑Yes❑NoNN/A a.®Yes❑No❑N/A b.❑Yes❑NoEN/A c.❑Yes❑No®N/A a.®Yes ❑No❑N/A b.❑Yes❑NoEN/A c ❑Yes❑No®N/A 45. During the Most Recent Semi -Annual Period, Was the SIU in SNC? ❑ Yes /1 No ❑ Yes L No ❑ Yes L No 46. During the Most Recent Semi -Annual Period, Was Enforcement Taken as Specified in the POTW's ERP (NOVs, Penalties, timing, etc.)? ❑Yes❑NoEN/A ®Yes❑No❑N/A ®Yes❑No❑N/A 47. Does the File Contain Penalty Assessment Notices? ❑Yes❑NoEN/A ❑Yes❑NoEN/A ❑Yes❑NoEN/A 48. Does The File Contain Proof Of Penalty Collection? ❑ Yes ❑NoEN/A ❑Yes❑NoEN/A ❑Yes❑NoEN/A 49. a. Does the File Contain Any Current Enforcement Orders? b. Is SIU in Compliance with Order? a.❑Yes❑NoEN/A b.❑Yes❑NoEN/A a.❑Yes❑NoEN/A b.❑Yes❑NoEN/A a.❑Yes❑NoEN/A b.❑Yes❑NoEN/A 50. Did the POTW Representative Have Difficulty in Obtaining Any of This Requested Information For You? ❑ Yes /1 No ❑ Yes r No ❑ Yes r No NC DWR Pretreatment Compliance Inspection (PCI) Form Updated 7/25/07 Page 2 FILE REVIEW COMMENTS: 19. CVG-Mayflower Vehicle Systems (CVG) was placed into SNC for the first half of 2020 due to the failures to perfoini/submit flow meter calibrations. KMI was placed into SNC for the first half of 2020 due to nickel and molybdenum TRC violations. 35. The POTW performed SIU inspections on 12/4/2020 (Cormetech), 9/30/2020 (KMI), and 9/30/2020 (CVG). 39. The POTW has currently contracted Meritech to perform all LTMP analyses. 41a. Cormetch and KMI both contract Pace Analytical Services, Inc. to perform analyses. CVG contracts PAR Laboratories to perform all analyses. 43b/46. KMI was issued a NOV for molybdenum and nickel limit violations (TRC) that were reported in August 2020. CVG was issued NOVs for cyanide violations reported in July 2020 and BOD limit violations reported in October 2020. SUMMARY AND COMMENTS: The January 2021 eDMR will be revised to correct the units of measurement for zinc (kg/day to ug/L) and remove the high level mercury value (composite sample) from the same column as the low level mercury value (grab sample). The high level mercury value can be recorded in the eDMR's comments section. The records reviewed during the inspection were organized and well maintained. The POTW's Industrial Pretreatment Program was being properly implemented. NOD: ❑ YES ® NO NOV: ❑ YES ® NO QNCR: ❑ YES ® NO POTW Rating: Satisfactory ❑ Marginal ❑ Unsatisfactory_ ❑ PCI COMPLETED BY: PCI REVIEWED BY: DocuSigned by: A61696D9OCC3137... DATE: 6/14/2021 Wes Bell, Sr. Environmental Specialist, Mooresville Regional Office r---DocuSigned by: 44 44t44, H P;xa e4 "-F161FB69A2D84A3... for WCB 6.15.21 DATE: W. Corey Basinger, Regional Supervisor, Mooresville Regional Office NC DWR Pretreatment Compliance Inspection (PCI) Form Updated 7/25/07 Page 3