Loading...
HomeMy WebLinkAboutNC0085731_Fact Sheet_20201117DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 FACT SHEET FOR EXPEDITED RENEWAL NPDES Permit NC0085731 orporon, LG - Compliance and Expedited Permitting Unit Basic nforma on for Expedited Permit Renewals Permittee / Owner: KBS III Carillon, L.P. Permittee Address 3003 Washington Blvd., Suite 950 Arlington VA Facility Name The Carillon Building — Dewatering and Treatment System Operator: Hines (704) 714-1100 Contact: 227 West Trade Street, Charlotte 28220 Basin / Sub -basin / Segment Catawba / 03-08-34 / 11-137-1 Receiving Stream Irwin Creek [via Trade St. storm -sewer] IWC 100% [storm -sewer discharge] Stream Classification in Permit C Does permit need Daily Max NH3 limits? Not applicable Does permit need TRC limits/language? Not applicable Does permit have toxicity testing? Yes. All tests passed since 2010. Parameters of Concern (POCs) Revised: PCE, WET Testing Does permit have Special Conditions? No Does permit have instream monitoring? No Is the stream impaired (on 303(d) list)? For what parameter? Yes. Copper, lead, and zinc are impairment factors. This facility does not discharge any of these parameters. Any obvious compliance concerns? No enforcements or effluent limit violations recorded in BIMS. Any permit modifications since last renewal? Completed building construction / discontinued excavation; permanent sub-terranean parking dewatering system completed in 2018. New expiration date 31Ju12025 Comments on Draft Permit ➢ DICHARGE HISTORY (FLOW in MGD) — Mar2015- Jun2020: Year L Max Min Average Number 2015 0.124 0.006 0.013 67 2016 0.012 0.008 0.010 64 2017 0.013 0.008 0.010 64 2018 0.012 0.006 0.012 63 2019 0.029 0.013 0.020 70 2020 0.031 0.006 0.017 42 [thru 20Aug] Parameters of Concern -- Past monitoring targeted Total Iron, Total Manganese, and Tetrachloroethene (PCE) as parameters of concern (POCs) in addition to Whole Effluent Toxicity (WET) testing. However, past POC databases reflect excavation dewatering now discontinued in the spring of 2018 when building construction was completed. Except for manganese, no POC was detected above its laboratory minimum detection level (MDL). Moreover, State-wide permitting guidance no longer considers iron and manganese POCs (no NC SWQ standard). Monitoring of iron and manganese is therefore discontinued. Page 1 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 As a spot-check for chlorinated hydrocarbons, PCE monitoring remains but without a permit limit (not detected in 22 Quarterly samples). WET testing will likewise continue Quarterly as required to evaluate this complex wastestream [see section A. (1.)]. No other changes recommended. Summary of Renewal Change Parameters Affected Basis for Condition(s) Continue monitoring Quarterly; no longer limited PCE Not detected but potential POC;; renewal consistent with current permitting guidance. Discontinue monitoring Total Iron Total Manganese Not detected; no longer considered POCs; consistent with permitting guidance. eDMR requires Phase II, beginning on the Effective Date All Per EPA required reporting strategy Changed expiration date 30Jun2025 All Per Basin Schedule Added WWTP Class All Per EPA required reporting strategy Updated Facility Map All Renewal Table 3. Dissolved Freshwater Standards for Hardness -Dependent Metals The Water Effects Ratio (WER) is equal to one unless determined otherwise under 15A NCAC 02B .0211 Subparagraph (11)(d) Metal NC Dissolved Standard, µg/1 Cadmium, Acute WER* {1.136672-[ln hardness](0.041838)} hardness]-3.1485 } • e^{0.9151 [In Cadmium, Acute Trout waters WER*{1.136672-[ln hardness](0.041838)} hardness]-3.6236} • e^{0.9151[ln Cadmium, Chronic WER*{1.101672-[ln hardness](0.041838)} hardness] -4.4451 } • e^{0.7998[In Chromium III, Acute WER*0.316 • e^{0.8190[ln hardness]+3.7256} Chromium III, Chronic WER*0.860 • e^{0.8190[ln hardness]+0.6848} Copper, Acute WER*0.960 • e^{0.9422[In hardness]-1.700} Copper, Chronic WER*0.960 • e^{0.8545[ln hardness]-1.702} Lead, Acute WER*{1.46203-[ln hardness](0.145712)} hardness]-1.460} • e^{1.273[In Lead, Chronic WER*{1.46203-[ln hardness](0.145712)} • e^{1.273[In Page 2 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 hardness]-4.705} Nickel, Acute WER*0.998 • e^{0.8460[ln hardness]+2.255} Nickel, Chronic WER*0.997 • e^{0.8460[ln hardness]+0.0584} Silver, Acute WER*0.85 • e^{1.72[In hardness]-6.59} Silver, Chronic Not applicable Zinc, Acute WER*0.978 • e^{0.8473[In hardness]+0.884} Zinc, Chronic WER*0.986 • e^{0.8473[In hardness]+0.884} General Information on the Reasonable Potential Analysis (RPA) The RPA process itself did not change as the result of the new metals standards. However, application of the dissolved and hardness -dependent standards requires additional consideration in order to establish the numeric standard for each metal of concern of each individual discharge. The hardness -based standards require some knowledge of the effluent and instream (upstream) hardness and so must be calculated case -by -case for each discharge. Metals limits must be expressed as `total recoverable' metals in accordance with 40 CFR 122.45(c). The discharge -specific standards must be converted to the equivalent total values for use in the RPA calculations. We will generally rely on default translator values developed for each metal (more on that below), but it is also possible to consider case -specific translators developed in accordance with established methodology. RPA Permitting Guidance/WQBELs for Hardness -Dependent Metals - Freshwater The RPA is designed to predict the maximum likely effluent concentrations for each metal of concern, based on recent effluent data, and calculate the allowable effluent concentrations, based on applicable standards and the critical low -flow values for the receiving stream. If the maximum predicted value is greater than the maximum allowed value (chronic or acute), the discharge has reasonable potential to exceed the standard, which warrants a permit limit in most cases. If monitoring for a particular pollutant indicates that the pollutant is not present (i.e. consistently below detection level), then the Division may remove the monitoring requirement in the reissued permit. 1. To perform a RPA on the Freshwater hardness -dependent metals the Permit Writer compiles the following information: • Critical low flow of the receiving stream, 7Q10 (the spreadsheet automatically calculates the 1Q10 using the formula 1Q10 = 0.843 (s7Q10, cfs) 0.993 • Effluent hardness and upstream hardness, site -specific data is preferred • Permitted flow • Receiving stream classification 2. In order to establish the numeric standard for each hardness -dependent metal of concern and for each individual discharge, the Permit Writer must first determine what effluent and instream (upstream) hardness values to use in the equations. Page 3 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 The permit writer reviews DMR's, Effluent Pollutant Scans, and Toxicity Test results for any hardness data and contacts the Permittee to see if any additional data is available for instream hardness values, upstream of the discharge. If no hardness data is available, the permit writer may choose to do an initial evaluation using a default hardness of 25 mg/L (CaCO3 or (Ca + Mg)). Minimum and maximum limits on the hardness value used for water quality calculations are 25 mg/L and 400 mg/L, respectively. If the use of a default hardness value results in a hardness -dependent metal showing reasonable potential, the permit writer contacts the Permittee and requests 5 site -specific effluent and upstream hardness samples over a period of one week. The RPA is rerun using the new data. The overall hardness value used in the water quality calculations is calculated as follows: Combined Hardness (chronic) = (Permitted Flow, cfs *Avg. Effluent Hardness, mg/L) x (s7Q10, cfs *Avg. Upstream Hardness, mg/L) (Permitted Flow, cfs + s7Q10, cfs) The Combined Hardness for acute is the same but the calculation uses the 1Q10 flow. 3. The permit writer converts the numeric standard for each metal of concern to a total recoverable metal, using the EPA Default Partition Coefficients (DPCs) or site -specific translators, if any have been developed using federally approved methodology. EPA default partition coefficients or the "Fraction Dissolved" converts the value for dissolved metal at laboratory conditions to total recoverable metal at in -stream ambient conditions. This factor is calculated using the linear partition coefficients found in The Metals Translator: Guidance for Calculating a Total Recoverable Permit Limit from a Dissolved Criterion (EPA 823-B-96-007, June 1996) and the equation: Cdiss = Ctotal 1 1 + { [Kpo] [SS(1+1 [10-6] Where: ss = in -stream suspended solids concentration [mg/1], minimum of 10 mg/L used, and Kpo and a = constants that express the equilibrium relationship between dissolved and adsorbed forms of metals. A list of constants used for each hardness -dependent metal can also be found in the RPA program under a sheet labeled DPCs. 4. The numeric standard for each metal of concern is divided by the default partition coefficient (or site -specific translator) to obtain a Total Recoverable Metal at ambient conditions. In some cases, where an EPA default partition coefficient translator does not exist (ie. silver), the dissolved numeric standard for each metal of concern is divided by the EPA conversion factor to obtain a Total Recoverable Metal at ambient conditions. This method presumes that the metal is dissolved to the same extent as it was during EPA's Page 4 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 criteria development for metals. For more information on conversion factors see the June, 1996 EPA Translator Guidance Document. 5. The RPA spreadsheet uses a mass balance equation to determine the total allowable concentration (permit limits) for each pollutant using the following equation: Ca = (s7Q10 + Qw) (Cwqs) — (s7Q10) (Cb) Qw Where: Ca = allowable effluent concentration (µg/L or mg/L) Cwqs = NC Water Quality Standard or federal criteria (µg/L or mg/L) Cb = background concentration: assume zero for all toxicants except NH3* (µg/L or mg/L) Qw = permitted effluent flow (cfs, match s7Q 10) s7Q 10 = summer low flow used to protect aquatic life from chronic toxicity and human health through the consumption of water, fish, and shellfish from noncarcinogens (cfs) * Discussions are on -going with EPA on how best to address background concentrations Flows other than s7Q10 may be incorporated as applicable: 1Q10 = used in the equation to protect aquatic life from acute toxicity QA = used in the equation to protect human health through the consumption of water, fish, and shellfish from carcinogens 30Q2 = used in the equation to protect aesthetic quality 6. The permit writer enters the most recent 2-3 years of effluent data for each pollutant of concern. Data entered must have been taken within four and one-half years prior to the date of the permit application (40 CFR 122.21). The RPA spreadsheet estimates the 95th percentile upper concentration of each pollutant. The Predicted Max concentrations are compared to the Total allowable concentrations to determine if a permit limit is necessary. If the predicted max exceeds the acute or chronic Total allowable concentrations, the discharge is considered to show reasonable potential to violate the water quality standard, and a permit limit (Total allowable concentration) is included in the permit in accordance with the U.S. EPA Technical Support Document for Water Quality -Based Toxics Control published in 1991. 7. When appropriate, permit writers develop facility specific compliance schedules in accordance with the EPA Headquarters Memo dated May 10, 2007 from James Hanlon to Alexis Strauss on 40 CFR 122.47 Compliance Schedule Requirements. 8. The Total Chromium NC WQS was removed and replaced with trivalent chromium and hexavalent chromium Water Quality Standards. As a cost savings measure, total chromium data results may be used as a conservative surrogate in cases where there are no analytical results based on chromium III or VI. In these cases, the projected maximum concentration (95th %) for total chromium will be compared against water quality standards for chromium III and chromium VI. 9. Effluent hardness sampling and instream hardness sampling, upstream of the discharge, are inserted into all permits with facilities monitoring for hardness -dependent metals to ensure the accuracy of the permit limits and to build a more robust hardness dataset. Hardness and flow values used in the Reasonable Potential Analysis for this permit included: Page 5 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Parameter Value Comments (Data Source) Average Effluent Hardness (mg/L) [Total as, CaCO3 or (Ca + Mg)] Average Upstream Hardness (mg/L) [Total as, CaCO3 or (Ca + Mg)] 7Q10 summer (cfs) 1 Q 1 0 (cfs) Permitted Flow (MGD) 0.0316 Outfall 001 (per permit) Page 6 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 LakeNorman c Che (Cliarlotte (Obsertrer c ha rlotteobservencom Carolina Bride._n•. M A L. A % F N AFFIDAVIT OF PUBLICATION Account # Ad Number Identification 145583 0004783025 Public Notice Nolih Carolina Environmental Management Commission/N Attention: Wren Thedford NCDENR/DWQ/POINT SOURCE 1617 MAIL SERVICE CENTER RALEIGH, NC 276991677 PUBLIC NOTICE North Carolina Environmental Management Comm isslonINPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Notice of Intent to issue a NPDES Wastewater Permit NC0065731 Carillon Building Dewatering System The North Carolina Environmental Management Commission proposes to issue a NPDES wastewater discharge permit to the person(s) listed below. Written comments regarding the proposed permit will be accepted until 30 days after the publish date of this notice. The Direc- tor of the NC Division of Water Resources (DWRI may hold a public hearing should there be a significant degree of public interest. Please mail comments and/or information requests to DWR at the above address. Interested persons may visit the UWR at 512 N. Salisbury Street. Raleigh, NC 27604 to review information on file. Additional information on NPDES permits and this notice may be found an our website: httpf/deq.nc.gov/eboutldiwslonslwater-resourceslwe ter-resources.parmitsfwastewater-branchlnpdes-wastewater/public-notices.or by calling (919) 707-3601, Wines Charlotte Carillon, LP requested renewal of NPDES permit NC0065731/Carillon Building/Mecklenburg County. Facility discharges remedlated groundwater to a storm sewer to frvnn Creek/Catawba River Basin. Currently tetrechloroethene Is water quality limited. LP4783026 North Carolina } ss Mecklenburg County } Before the undersigned, a Notary Public of said County and State. duly authorized to administer oaths affirmations, etc., personally appeared, being duly sworn or affirmed according to law, Both depose and say that he/she is a representative of The Charlotte Observer Publishing Company, a corporation organized and doing business under the laws of the State of Delaware, and publishing a newspaper known as The Charlotte Observer in the city of Charlotte, County of Mecklenburg, and State of North Carolina and that as such he/she is familiar with the books, records, files, and business of said Corporation and by reference to the files of said publication, the attached advertisement was inserted. The following is correctly copied from the Insertion(s) Published On: October 16. 2020 e fik2,ep Cherri Foster, Regional Office Associate In Testimony Whereof I have hereunto set my hand and affixed my seal on the 15th day of October. 2020 Electl6nic Notary Public State of North narnlina �Xyr 4t % ZOE= 7ij'ngr / T 2021 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 ROY COOPER MICHAEL S. REGAN Secretary LINDA CULPEPPER Director KBSIII Carillon, L.P. Attn: Allen Aldridge, Senior VP 3003 Washington Blvd Ste 950 Arlington, VA 22201 Subject: Permit Renewal Application No. NC0085731 Carillon Building Dewatering System Mecklenburg County NORTH CAROLINA Environmental Quality January 06, 2020 Dear Applicant: The Water Quality Permitting Section acknowledges the December 20, 2019 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. cc: Brian E. Wilson, S & ME, Inc. ec: WQPS Laserfiche File w/application Sincerel Wren Thedford Administrative Assistant Water Quality Permitting Section North Caro' na Department of Envronmenta!Quality I D,vSor of Water Resources Moo resv aRegne Off ce1610East Center Avenue, Si. to3011 Mooresv e,North Caro na26115 744.663-1699 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 December 20, 2019 NCDEQ Division of Water Resources NPDES Unit 1617 Mail Services Center Raleigh, NC 27699-1617 Attention: Mr. Wren Thedford Reference: NPDES Permit Renewal Application KBSIII Carillon LLC Carillon Building Dewatering System Charlotte, Mecklenburg County, North Carolina NPDES Permit No. NC0085731 Dear Mr. Thedford: geceiveo 10, 10 W,pEQONRIIODES On behalf of our client, KBSIII Carillon, L.P., (KBSIII), S&ME, Inc. (S&ME) is pleased to submit the attached NPDES Permit Renewal Application (Short Form C-GW) for the renewal of the existing permit. No changes in the groundwater treatment system components or processes have been made since the issuance of the existing permit on August 10, 2015. Note that in submitting the attached application, S&ME is serving as an authorized agent of KBSIII on this project. A letter granting such authority to S&ME is also attached to this correspondence. Recovered groundwater is pumped into a holding tank where it is eventually routed through two in -line canisters filled with granular activated carbon prior to being discharged to the storm sewer system. The subject facility does not generate any sludge or other solids; therefore, a Sludge Management Plan has not been prepared for this facility. Please contact us if you have any questions regarding this submittal. Sincerely, S&ME, Inc. Brian E. Wilson Project Professional, ORC David R. Loftis, P. . Senior Engineer Attachments: Short Form C-GW Figure 1 - Site Location Map Laboratory Analytical Report, System Effluent (December 2019) Delegation of Signature Authority S&ME, Inc. 19751 Southern Pine Boulevard I Charlotte, NC 28273 ( p 704.523.4726 I www.smeinc.com DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 NPDES PERMIT APPLICATION - SHORT FORM C - GW For discharges associated with groundwater treatment facilities. Mail the complete application to: NC DEQ / DWR / NPDES 1617 Mail Service Center Raleigh, NC 27699-1617 NPDES Permit Number NC0085731 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name Facility Name Mailing Address City State / Zip Code Telephone Number Fax Number e-mail Address KBSIII Carillon, L.P. Carillon Building Dewatering System 3003 Washington Blvd., Suite 950 Arlington Virginia RECEIVED (202) 552-7553 DEC 2 0 2019 ( ) NCDEQ/DWR/NPDES aaldridge@kbs.com 2. Location of facility producing discharge: Check here if same as above 0 Street Address or State Road 227 West Trade Street City State / Zip Code County Charlotte NC 28202 Mecklenburg 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Hines Mailing Address City State / Zip Code Telephone Number Fax Number 4. Ownership Status: 227 West Trade Street, Suite 330 Charlotte NC 28202 (704)714-1100 ( ) Federal ❑ State ❑ Private ® Public ❑ Page 1 of 3 C-GW 6/17 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 NPDES PERMIT APPLICATION - SHORT FORM C - GW For discharges associated with groundwater treatment facilities. 5. Products recovered: Gasoline ❑ Diesel fuel ❑ 6. Number of separate discharge points: 1 Outfall Identification number(s) 001 Solvents ® Other 7. Frequency of discharge: Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: 7 Duration: 24 hrs 8. Treatment System Design flow 0.0316 MGD 9. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Irwin Creek 10. Please list all additives to the treatment system, including chemicals or nutrients, that have the potential to be discharged. 11. Is this facility located on Indian country? (check one) Yes ❑ No 12. Additional Information All applicants (including renewals): • A USGS topographical map (or copy of the relevant portion) which shows all outfalls • A summary of the most recent analytical results (effluent data, if available) containing the maximum values for each chemical detected NEW Applicants only: • Engineering Alternative Analysis • Description of remediation treatment system components, capacities, and removal efficiency for detected compounds. • If the treatment system will discharge to a storm sewer, written approval from the municipality responsible for the sewer. • A list of any chemicals found in detectable amounts at the site, with the maximum observed concentration reported for each chemical (the most recent sample must be collected less than one year prior to the date of this application) • For petroleum -contaminated sites - Analyses for Volatile Organic Compounds (VOC) should be performed. Analyses for any fuel additives likely to be present at the site and for phenol and lead should also be performed. • For sites contaminated with solvents or other contaminants - EPA Method 624/625 analysis should be performed. Page 2 of 3 C-GW 6/17 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 NPDES PERMIT APPLICATION - SHORT FORM C - GW For discharges associated with groundwater treatment facilities. 13. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. 44A-IQ E. (Nits Printed name of Person Signing -ea,-,a- foic.c 1- &Ie4 J-, oQ.c V Title /zzolI 9 Signat e of Applicant Date North Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) Page 3 of 3 C-GW 6/17 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 \SiteLocation.mxd plotted by DHomans 12-11-2019 the Q:\1354\200 DALTON AVE IRWIN CREEK DISCHARGE LOCATION � F 4,/ sf C -•n,,ixinity College _ontial Camps 1,500 4,500 (FEET) REFERENCE: USGS USA TOPO STREAMING DATASET GIS BASE LAYERS WERE OBTAINED FROM USGS NATIONAL MAP. THIS MAP 15 FOR INFORMATIONAL PURPOSES ONLY. ALL FEATURE LOCATIONS DISPLAYED ARE APPROXIMATED. THEY ARE NOT BASED ON CIVIL SURVEY INFORMATION, UNLESS STATED OTHERWISE. SITE LOCATION MAP THE CARILLON BUILDING 227 WEST TRADE STREET SUITE 300 CHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINA SCALE: 1 " = 1,500 ' DATE: 12-11-19 PROJECT NUMBER 1354-07-001 Elizabeth Tracitcaial Elementary School rn FIGURE NO. 1 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Case Narrative PRISM LABORATORIES. INC S&ME, Inc - Charlotte Brian Wilson 9751 Southern Pine Blvd. Charlotte, NC 28273 Full -Service Analytical & Environmental Solutions NC Certification No. 402 NC Drinking Water Cert No. 37735 SC Certification No. 99012 Project: Carillon Bldg Dewatering Sys. Lab Submittal Date: 12/02/2019 Prism Work Order: 9120006 12/10/19 9:58 This data package contains the analytical results for the project identified above and includes a Case Narrative, Sample Results and Chain of Custody. Unless otherwise noted, all samples were received in acceptable condition and processed according to the referenced methods. Data qualifiers are flagged individually on each sample. A key reference for the data qualifiers appears at the end of this case narrative. Please call if you have any questions relating to this analytical report. Respectfully, PRISM LABORATORIES, INC. Angela D. Overcash VP Laboratory Services Reviewed By Angela D. Overcash VP Laboratory Services Data Qualifiers Key Reference: BRL Below Reporting Limit MDL Method Detection Limit RPD Relative Percent Difference * Results reported to the reporting limit. All other results are reported to the MDL with values between MDL and reporting limit indicated with a J. This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 1 of 7 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 PRISMI `- n^ I Full -Service Analytical 8. 1 J' V' Environmental Solutions LABORATORIES INC Sample Receipt Summary 12/10/2019 Prism Work Order: 9120006 Client Sample ID Lab Sample ID Matrix Date/Time Sampled Date/Time Received Effluent 9120006-01 Water 12/02/19 9:45 12/02/19 10:35 Samples were received in good condition at 5.0 degrees C unless otherwise noted. This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 2 of 7 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 /PRISM I Environmuli ee Aal ution Environmental Solutions LABORATORIES INC Summary of Detections Prism Work Order: Prism ID Client ID Parameter Method Result Units There were no detections reported. This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 3 of 7 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Full -Service Analytical & I R I S M Environmental Solutions LABORATORIES, INC S&ME, Inc - Charlotte Attn: Brian Wilson 9751 Southern Pine Blvd. Charlotte, NC 28273 Project: Carillon Bldg Dewatering Sys. Sample Matrix: Water Laboratory Report 12/10/2019 Client Sample ID: Effluent Prism Sample ID: 9120006-01 Prism Work Order: 9120006 Time Collected: 12/02/19 09:45 Time Submitted: 12/02/19 10:35 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Total Metals Iron BRL mg/L 0.30 0.16 1 *6010D 12/5/19 11:52 JAB P9L0067 Manganese BRL mg/L 0.030 0.015 1 *6010D 12/5/19 11:52 JAB P9L0067 Volatile Organic Compounds by GC/MS Tetrachloroethylene BRL ug/L 0.50 0.098 1 SM6200 B 12/6/19 18:02 JLB P9L0150 Surrogate Recovery Control Limits 4-Bromofluorobenzene 101 % 70-130 Dibromofluoromethane 101 % 70-130 Toluene-d8 100 % 70-130 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 4 of 7 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 /P.RISLABORATOR,M Full -Service Analytical & Environmental Solutions S&ME, Inc - Charlotte Attn: Brian Wilson 9751 Southern Pine Blvd. Charlotte, NC 28273 Level II QC Report 12/10/19 Project: Carillon Bldg Dewatering Sys. Prism Work Order: 9120006 Time Submitted: 12/2/2019 10:35:OOAM Volatile Organic Compounds by GC/MS - Quality Control Reporting Spike Source %REC RPD Analyte Result Limit Units Level Result %REC Limits RPD Limit Notes Batch P9L0150 - SM6200 B Blank (P9L0150-BLK1) Prepared & Analyzed: 12/06/19 Tetrachloroethylene BRL 0.50 ug/L Surrogate: 4-Bromofluorobenzene 51.0 ug/L 50.00 102 70-130 Surrogate: Dibromofluoromethane 51.8 ug/L 50.00 104 70-130 Surrogate: Toluene-d8 50.3 ug/L 50.00 101 70-130 LCS (P9L0150-BS1) Prepared &Analyzed: 12/06/19 Tetrachloroethylene 20.8 0.50 ug/L 20.00 104 70-130 Surrogate: 4-Bromofluorobenzene 50.5 ug/L 50.00 101 70-130 Surrogate: Dibromofluoromethane 49.1 ug/L 50.00 98 70-130 Surrogate: Toluene-d8 49.7 ug/L 50.00 99 70-130 LCS Dup (P9L0150-BSD1) Prepared &Analyzed: 12/06/19 Tetrachloroethylene 22.3 0.50 ug/L 20.00 111 70-130 7 20 Surrogate: 4-Bromofluorobenzene 50.0 ug/L 50.00 100 70-130 Surrogate: Dibromofluoromethane 48.8 ug/L 50.00 98 70-130 Surrogate: Toluene-d8 50.2 ug/L 50.00 100 70-130 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 5 of 7 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 /PRISM uBOQAromss INC. Full -Service Analytical & Environmental Solutions S&ME, Inc - Charlotte Attn: Brian Wilson 9751 Southern Pine Blvd. Charlotte, NC 28273 Total Metals - Quality Control Level II QC Report 12/10/19 Project: Carillon Bldg Dewatering Sys. Prism Work Order: 9120006 Time Submitted: 12/2/2019 10:35:OOAM Reporting Spike Source %REC RPD Analyte Result Limit Units Level Result %REC Limits RPD Limit Notes Batch P9L0067 - 3010A Blank (P9L0067-BLK1) Prepared: 12/04/19 Analyzed: 12/05/19 Iron BRL 0.30 mg/L Manganese BRL 0.030 mg/L LCS (P9L0067-BS1) Prepared: 12/04/19 Analyzed: 12/05/19 Iron Manganese Matrix Spike (P9L0067-MS1) 50.5 0.30 mg/L 50.00 101 80-120 0.477 0.030 mg/L 0.5001 95 80-120 Source: 9120006-01 Prepared: 12/04/19 Analyzed: 12/05/19 Iron 49.5 0.30 mg/L 50.00 BRL 99 75-125 Manganese 0.489 0.030 mg/L 0.5001 BRL 98 75-125 Matrix Spike Dup (P9L0067-MSD1) Source: 9120006-01 Prepared: 12/04/19 Analyzed: 12/05/19 Iron Manganese Prep Method: 3010A Lab Number 50.4 0.30 mg/L 50.00 BRL 101 75-125 2 20 0.495 0.030 mg/L 0.5001 BRL 99 75-125 1 20 Sample Extraction Data Batch Initial Final DatefTime 9120006-01 P9L0067 50 mL 50 mL 12/04/19 7:08 Prep Method: SM6200 B Lab Number Batch Initial Final Date/Time 9120006-01 P9L0150 10 mL 10 mL 12/06/19 10:14 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 6 of 7 uocu ign tnvelope iu: IOHO //ru-29a ur (p,DL,o PRISM LABORATORIES INC Full -Service Analytical & Environmental Solutions 449 Springbrook Road • Charlotte, NC 28217 Phone 704/529-6364 • ax:70_,1525-0409 Client Company Name: _- l l Report To/Contact Name: R9pDrtin Tress: e C 2?-2 Phone:2(2 yT2i 4.f 7Z ' Fax (Yes) (No): Email Address: EDD Type: PDF I Ex Site Location Name: Site Location Physical Address:(1 . Other 411 lti Sti ;12 c AA CHAIN OF CUSTODY RECORD PAGE_ OF/ gUOTE # TO ENSURE PROPER BILLING: !!f // ,) / Project Name: L; °.y///%"`" - ,t.. v.. ,. j - ..--- Short Hold Analysis: (Yes) �K I4ST Project: (Yes)Q 'Please ATTACH any project Specific reporting (QC LEVEL 1 11 111 IV) provisions quai9r,QC Re uelne is Invoice To: e j i4`5" Address: ? P Purchase Order No./Billing Reference /'1SY 0? Oc ) LAB USE ONLY Samples INTACT upon arrival? Received ON WET ICE? PROPER PRESERVATIVES indicated? Received WITHIN HOLDING TIMES? CUSTODY SEALS INTACT? VOLATILES rec'd W/OUT HEADSPACE? PROPER CONTAINERS used', TEMP: Therm ID I' I - Observed YES NO L — N/A 0 CL t) (0 °C / Corr S 1y °C Requested Due Date ❑ 1 Day ❑ 2 Days ❑ 3 Days ❑ 4 Days ❑ 5 Days "Working Days" ❑ 6-9 Days- tandard 10 days ❑ preSAWork dust Be Samples received after 14:00 will a prccessed next business day. Turnaround time is based on business days, excluding weekends and holidays, (SEE REVERSE FOR TERMS 8 CONDITIONS REGARDING SERVICES RENDERED BY PRISM LABORATORIES, INC. TO CLIENT) CLIENT DATE SAMPLE DESCRIPTION COLLECTED artgeivr_PNI TIME MATRIX COLLECTED (SOIL, MILITARY WATER OR HOURS SLUDGE) SAMPLE CONTAINER *TYPE NO. SIZE SEE BELOW Iwr "iP '- 2P ne- /03 PRESERVA- TIVES • Z17 ��/ v•0 Sampled By (Print Name) 46,4441 /IA S TO BE FILLED IN BY CLIENT/SAMPLING PERSON��L Certification: NELAC DoD FL NC 1 SC OTHER N/A Water Chlorinated: YES NO X. — 7_', Sample Iced Upon Collection: YES; NO \NALYSIS REQUESTED l\' ,/ Upon relinquish r 1hi Chain of Custody is your authorization for Prism to proceed with the analyses as requested above. Any changes must be submitte r t g to the Prism Project Manager. There will be charges for any changes after analyses have been initialized. Reunqur•- ,ad Is• 63natl9ra) gnature) Relinquished By: (Signature) Received BY. (Signature) Received By: (Signature) ~Re.1 For Prism Laboratories Ey Metnoo of Shipment: NOTE: ALL SAMPLE COOLERS SHOULD BE TAPED SHUT WITH CUSTODY SEALS FOR TRANSPORTATION TO THE LABORATOR SAMPLES ARE NOT ACCEPTED AND VERIFIED AGAINST COC UNTIL RECEIVED AT THE LABORATORY. ❑ Fed Ex ❑ UPS ❑ Hand -delivered ❑ Prism Field Service ❑ Ulhor Dalo jzZ Date Military/Hours /t)3s Date / Z/a COC Gfou No NPDES• UST: GROUNDWATER: DRINKING WATER: SOLID WASTE: RCRA: CERCLA i LANDFILL OTHER: �cJNC❑SC ❑NC ❑SC ❑NC ❑SC ❑NC ❑SC ❑NC ID SC ❑NC❑SC ❑NC ❑SC CI NC ❑SC ❑NC ❑SC , 0 -- -- ❑ 0 ❑ ❑ ❑ ❑ ❑ 0 "CONTAINER TYPE CODES: A = Amber C = Clear G= Glass P = Plastic; TL = Teflon -Lined Cap VOA = Volatile Organics Analysis (Zero Head Space) REMARKS / PRISM LAB ID NO. oI PRESS DOWN FIRMLY - 3 COPIES Additional Comments: PRISM USE ONLY' Site Arrival Time: Site Departure Time. Field Tech Fee: Mileage. SEE REVERSE FOR TERMS & CONDITIONS ORIGINAL DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 December 16, 2019 Wastewater Branch Water Quality Permitting Section Division of Water Resources 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: Delegation of Signature Authority THE CARILLON BUILDING DEWATERING SYSTEM NPDES Permit Number NC0085731 To Whom It May Concern: By notice of this letter, I hereby delegate signatory authority to each of the following individuals for all permit applications, discharge monitoring reports, and other information relating to the operations at the subject facility as required by all applicable federal, state, and local environmental agencies specifically with the requirements for signatory authority as specified in 15A NCAC 2B.0506. Individual #1 Individual #2 (if applicable) Name: Title: Mailing Address: Physical Address: (if different) Email Address: Office Phone: Mobile Phone: Brian E. Wilson Project Scientist, Orc 9751 Southern Pine Boulevard Charlotte, Nc 28273 bwilson@smeinc.com 704 - 523 - 4726 704-460-7121 David R. Loftis Senior Engineer 44 Buck Shoals Road, Suite C-3 Arden, Nc 28704 dloftis@smeinc.com 828 - 483 - 3012 828 - 337 - 1923 If you have any questions regarding this letter, please feel free to contact me at aaldridge@kbs.com or 202-552-7553. Sincerely, Ca, Allen Aldridge, Senior KBSIII Carillon, L.P 3003 Washington Blvd., Suite 950 Arlington, Va 22201 Aaldridge@Kbs.Com 202-552-7553 ice President cc: Mooresville Regional Office, Water Quality Permitting Section DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 ..W........ ....,..... ..... y ..... I .............. UoM Value Modifier NC0085731 3 3 2015 NC0085731 6 4 2015 NC0085731 9 2 2015 NC0085731 12 8 2015 NC0085731 3 3 2016 NC0085731 6 9 2016 NC0085731 9 15 2016 NC0085731 12 8 2016 NC0085731 3 8 2017 NC0085731 6 8 2017 NC0085731 9 12 2017 NC0085731 12 5 2017 NC0085731 3 6 2018 NC0085731 6 4 2018 NC0085731 9 4 2018 NC0085731 1 16 2019 NC0085731 3 5 2019 NC0085731 6 11 2019 NC0085731 9 12 2019 NC0085731 12 2 2019 NC0085731 3 4 2020 NC0085731 6 2 2020 NC0085731 3 3 2015 NC0085731 6 4 2015 NC0085731 9 2 2015 NC0085731 12 8 2015 NC0085731 3 3 2016 NC0085731 6 9 2016 NC0085731 9 15 2016 NC0085731 12 8 2016 NC0085731 3 8 2017 NC0085731 6 8 2017 NC0085731 9 12 2017 NC0085731 12 5 2017 NC0085731 3 6 2018 NC0085731 6 4 2018 NC0085731 9 4 2018 NC0085731 1 16 2019 NC0085731 3 5 2019 NC0085731 6 11 2019 NC0085731 9 12 2019 NC0085731 12 2 2019 NC0085731 3 4 2020 NC0085731 6 2 2020 NC0085731 1 5 2015 NC0085731 1 13 2015 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01045 - Iron, 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 01055 - Manganese 50050 - Flow 50050 - Flow mg/I 50 LESSTHAN ug/I 50 LESSTHAN ug/I 50 LESSTHAN mg/I 50 LESSTHAN ug/I 50 LESSTHAN ug/I 50 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.1 LESSTHAN mg/I 0.3 LESSTHAN mg/I 0.3 LESSTHAN mg/I 0.3 LESSTHAN mg/I 0.3 LESSTHAN mg/I 0.3 LESSTHAN ug/I 5 LESSTHAN ug/I 5 LESSTHAN ug/I 2.5 ug/I 17.2 ug/I 5 LESSTHAN ug/I 5 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.01 LESSTHAN mg/I 0.03 LESSTHAN mg/I 0.03 mg/I 0.03 LESSTHAN mg/I 0.03 LESSTHAN mg/I 0.03 LESSTHAN mgd 0.021 mgd 0.021 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 5 5 2.5 17.2 5 5 10 10 10 10 10 10 10 10 10 10 10 30 30 30 30 30 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 mgd 0.021 NC0085731 1 26 2015 50050 - Flow mgd 0.021 NC0085731 2 2 2015 50050 - Flow mgd 0.014 NC0085731 2 11 2015 50050 - Flow mgd 0.024 NC0085731 2 21 2015 50050 - Flow mgd 0.021 NC0085731 2 27 2015 50050 - Flow mgd 0.022 NC0085731 3 2 2015 50050 - Flow mgd 0.022 NC0085731 3 3 2015 50050 - Flow mgd 0.022 NC0085731 3 4 2015 50050 - Flow mgd 0.022 NC0085731 3 5 2015 50050 - Flow mgd 0.022 NC0085731 3 9 2015 50050 - Flow mgd 0.022 NC0085731 3 16 2015 50050 - Flow mgd 0.022 NC0085731 3 23 2015 50050 - Flow mgd 0.022 NC0085731 3 30 2015 50050 - Flow mgd 0.022 NC0085731 4 8 2015 50050 - Flow mgd 0.02 NC0085731 4 14 2015 50050 - Flow mgd 0.019 NC0085731 4 24 2015 50050 - Flow mgd 0.019 NC0085731 5 1 2015 50050 - Flow mgd 0.018 NC0085731 5 7 2015 50050 - Flow mgd 0.018 NC0085731 5 14 2015 50050 - Flow mgd 0.017 NC0085731 5 18 2015 50050 - Flow mgd 0.017 NC0085731 5 27 2015 50050 - Flow mgd 0.016 NC0085731 6 1 2015 50050 - Flow mgd 0.016 NC0085731 6 2 2015 50050 - Flow mgd 0.015 NC0085731 6 3 2015 50050 - Flow mgd 0.015 NC0085731 6 4 2015 50050 - Flow mgd 0.015 NC0085731 6 12 2015 50050 - Flow mgd 0.014 NC0085731 6 15 2015 50050 - Flow mgd 0.013 NC0085731 6 22 2015 50050 - Flow mgd 0.013 NC0085731 6 30 2015 50050 - Flow mgd 0.011 NC0085731 7 9 2015 50050 - Flow mgd 0.01 NC0085731 7 15 2015 50050 - Flow mgd 0.011 NC0085731 7 21 2015 50050 - Flow mgd 0.01 NC0085731 7 27 2015 50050 - Flow mgd 0.01 NC0085731 8 3 2015 50050 - Flow mgd 0.008 NC0085731 8 10 2015 50050 - Flow mgd 0.009 NC0085731 8 17 2015 50050 - Flow mgd 0.008 NC0085731 8 24 2015 50050 - Flow mgd 0.008 NC0085731 8 31 2015 50050 - Flow mgd 0.008 NC0085731 9 2 2015 50050 - Flow mgd 0.008 NC0085731 9 3 2015 50050 - Flow mgd 0.007 NC0085731 9 8 2015 50050 - Flow mgd 0.007 NC0085731 9 14 2015 50050 - Flow mgd 0.008 NC0085731 9 15 2015 50050 - Flow mgd 0.007 NC0085731 9 16 2015 50050 - Flow mgd 0.008 NC0085731 9 17 2015 50050 - Flow mgd 0.007 NC0085731 9 21 2015 50050 - Flow mgd 0.007 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 mgd 0.006 NC0085731 10 5 2015 50050 - Flow mgd 0.008 NC0085731 10 12 2015 50050 - Flow mgd 0.008 NC0085731 10 19 2015 50050 - Flow mgd 0.007 NC0085731 10 29 2015 50050 - Flow mgd 0.007 NC0085731 11 3 2015 50050 - Flow mgd 0.008 NC0085731 11 10 2015 50050 - Flow mgd 0.009 NC0085731 11 20 2015 50050 - Flow mgd 0.01 NC0085731 11 24 2015 50050 - Flow mgd 0.01 NC0085731 12 2 2015 50050 - Flow mgd 0.009 NC0085731 12 4 2015 50050 - Flow mgd 0.008 NC0085731 12 7 2015 50050 - Flow mgd 0.008 NC0085731 12 8 2015 50050 - Flow mgd 0.007 NC0085731 12 9 2015 50050 - Flow mgd 0.008 NC0085731 12 10 2015 50050 - Flow mgd 0.008 NC0085731 12 16 2015 50050 - Flow mgd 0.008 NC0085731 12 21 2015 50050 - Flow mgd 0.008 NC0085731 12 28 2015 50050 - Flow mgd 0.01 NC0085731 1 5 2016 50050 - Flow mgd 0.011 NC0085731 1 11 2016 50050 - Flow mgd 0.011 NC0085731 1 18 2016 50050 - Flow mgd 0.01 NC0085731 1 25 2016 50050 - Flow mgd 0.009 NC0085731 2 4 2016 50050 - Flow mgd 0.01 NC0085731 2 9 2016 50050 - Flow mgd 0.011 NC0085731 2 17 2016 50050 - Flow mgd 0.011 NC0085731 2 22 2016 50050 - Flow mgd 0.011 NC0085731 2 29 2016 50050 - Flow mgd 0.011 NC0085731 3 1 2016 50050 - Flow mgd 0.011 NC0085731 3 2 2016 50050 - Flow mgd 0.011 NC0085731 3 3 2016 50050 - Flow mgd 0.011 NC0085731 3 8 2016 50050 - Flow mgd 0.011 NC0085731 3 14 2016 50050 - Flow mgd 0.012 NC0085731 3 24 2016 50050 - Flow mgd 0.012 NC0085731 3 30 2016 50050 - Flow mgd 0.012 NC0085731 4 6 2016 50050 - Flow mgd 0.011 NC0085731 4 12 2016 50050 - Flow mgd 0.01 NC0085731 4 18 2016 50050 - Flow mgd 0.01 NC0085731 4 26 2016 50050 - Flow mgd 0.009 NC0085731 5 2 2016 50050 - Flow mgd 0.009 NC0085731 5 11 2016 50050 - Flow mgd 0.009 NC0085731 5 18 2016 50050 - Flow mgd 0.009 NC0085731 5 23 2016 50050 - Flow mgd 0.009 NC0085731 6 1 2016 50050 - Flow mgd 0.01 NC0085731 6 6 2016 50050 - Flow mgd 0.01 NC0085731 6 7 2016 50050 - Flow mgd 0.011 NC0085731 6 8 2016 50050 - Flow mgd 0.011 NC0085731 6 9 2016 50050 - Flow mgd 0.011 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 mgd 0.011 NC0085731 6 20 2016 50050 - Flow mgd 0.011 NC0085731 6 27 2016 50050 - Flow mgd 0.011 NC0085731 7 7 2016 50050 - Flow mgd 0.011 NC0085731 7 12 2016 50050 - Flow mgd 0.011 NC0085731 7 18 2016 50050 - Flow mgd 0.01 NC0085731 7 27 2016 50050 - Flow mgd 0.009 NC0085731 8 3 2016 50050 - Flow mgd 0.009 NC0085731 8 9 2016 50050 - Flow mgd 0.009 NC0085731 8 18 2016 50050 - Flow mgd 0.01 NC0085731 8 23 2016 50050 - Flow mgd 0.01 NC0085731 9 2 2016 50050 - Flow mgd 0.009 NC0085731 9 8 2016 50050 - Flow mgd 0.009 NC0085731 9 12 2016 50050 - Flow mgd 0.009 NC0085731 9 13 2016 50050 - Flow mgd 0.009 NC0085731 9 14 2016 50050 - Flow mgd 0.009 NC0085731 9 15 2016 50050 - Flow mgd 0.009 NC0085731 9 20 2016 50050 - Flow mgd 0.008 NC0085731 9 28 2016 50050 - Flow mgd 0.009 NC0085731 10 6 2016 50050 - Flow mgd 0.01 NC0085731 10 11 2016 50050 - Flow mgd 0.011 NC0085731 10 21 2016 50050 - Flow mgd 0.011 NC0085731 10 26 2016 50050 - Flow mgd 0.011 NC0085731 11 4 2016 50050 - Flow mgd 0.01 NC0085731 11 9 2016 50050 - Flow mgd 0.01 NC0085731 11 17 2016 50050 - Flow mgd 0.009 NC0085731 11 21 2016 50050 - Flow mgd 0.009 NC0085731 11 29 2016 50050 - Flow mgd 0.008 NC0085731 12 5 2016 50050 - Flow mgd 0.008 NC0085731 12 6 2016 50050 - Flow mgd 0.009 NC0085731 12 7 2016 50050 - Flow mgd 0.009 NC0085731 12 8 2016 50050 - Flow mgd 0.009 NC0085731 12 12 2016 50050 - Flow mgd 0.009 NC0085731 12 21 2016 50050 - Flow mgd 0.008 NC0085731 12 30 2016 50050 - Flow mgd 0.008 NC0085731 1 6 2017 50050 - Flow mgd 0.008 NC0085731 1 13 2017 50050 - Flow mgd 0.008 NC0085731 1 19 2017 50050 - Flow mgd 0.009 NC0085731 1 26 2017 50050 - Flow mgd 0.009 NC0085731 2 3 2017 50050 - Flow mgd 0.009 NC0085731 2 9 2017 50050 - Flow mgd 0.009 NC0085731 2 14 2017 50050 - Flow mgd 0.01 NC0085731 2 23 2017 50050 - Flow mgd 0.01 NC0085731 3 3 2017 50050 - Flow mgd 0.009 NC0085731 3 6 2017 50050 - Flow mgd 0.008 NC0085731 3 7 2017 50050 - Flow mgd 0.008 NC0085731 3 8 2017 50050 - Flow mgd 0.008 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 mgd 0.008 NC0085731 3 16 2017 50050 - Flow mgd 0.008 NC0085731 3 21 2017 50050 - Flow mgd 0.009 NC0085731 3 28 2017 50050 - Flow mgd 0.009 NC0085731 4 5 2017 50050 - Flow mgd 0.009 NC0085731 4 13 2017 50050 - Flow mgd 0.009 NC0085731 4 21 2017 50050 - Flow mgd 0.009 NC0085731 4 26 2017 50050 - Flow mgd 0.01 NC0085731 5 2 2017 50050 - Flow mgd 0.01 NC0085731 5 12 2017 50050 - Flow mgd 0.01 NC0085731 5 18 2017 50050 - Flow mgd 0.01 NC0085731 5 25 2017 50050 - Flow mgd 0.011 NC0085731 5 30 2017 50050 - Flow mgd 0.012 NC0085731 6 5 2017 50050 - Flow mgd 0.011 NC0085731 6 6 2017 50050 - Flow mgd 0.012 NC0085731 6 7 2017 50050 - Flow mgd 0.012 NC0085731 6 8 2017 50050 - Flow mgd 0.012 NC0085731 6 15 2017 50050 - Flow mgd 0.012 NC0085731 6 21 2017 50050 - Flow mgd 0.012 NC0085731 6 30 2017 50050 - Flow mgd 0.012 NC0085731 7 5 2017 50050 - Flow mgd 0.012 NC0085731 7 11 2017 50050 - Flow mgd 0.013 NC0085731 7 21 2017 50050 - Flow mgd 0.012 NC0085731 7 26 2017 50050 - Flow mgd 0.012 NC0085731 8 3 2017 50050 - Flow mgd 0.012 NC0085731 8 11 2017 50050 - Flow mgd 0.012 NC0085731 8 18 2017 50050 - Flow mgd 0.013 NC0085731 8 23 2017 50050 - Flow mgd 0.013 NC0085731 8 29 2017 50050 - Flow mgd 0.013 NC0085731 9 5 2017 50050 - Flow mgd 0.012 NC0085731 9 11 2017 50050 - Flow mgd 0.012 NC0085731 9 12 2017 50050 - Flow mgd 0.013 NC0085731 9 13 2017 50050 - Flow mgd 0.013 NC0085731 9 14 2017 50050 - Flow mgd 0.011 NC0085731 9 20 2017 50050 - Flow mgd 0.01 NC0085731 9 29 2017 50050 - Flow mgd 0.01 NC0085731 10 4 2017 50050 - Flow mgd 0.01 NC0085731 10 13 2017 50050 - Flow mgd 0.01 NC0085731 10 18 2017 50050 - Flow mgd 0.01 NC0085731 10 25 2017 50050 - Flow mgd 0.01 NC0085731 10 31 2017 50050 - Flow mgd 0.01 NC0085731 11 6 2017 50050 - Flow mgd 0.01 NC0085731 11 15 2017 50050 - Flow mgd 0.009 NC0085731 11 20 2017 50050 - Flow mgd 0.011 NC0085731 11 27 2017 50050 - Flow mgd 0.008 NC0085731 12 4 2017 50050 - Flow mgd 0.009 NC0085731 12 5 2017 50050 - Flow mgd 0.009 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 mgd 0.009 NC0085731 12 7 2017 50050 - Flow mgd 0.008 NC0085731 12 12 2017 50050 - Flow mgd 0.008 NC0085731 12 18 2017 50050 - Flow mgd 0.008 NC0085731 12 29 2017 50050 - Flow mgd 0.008 NC0085731 1 5 2018 50050 - Flow mgd 0.007 NC0085731 1 12 2018 50050 - Flow mgd 0.007 NC0085731 1 19 2018 50050 - Flow mgd 0.006 NC0085731 1 25 2018 50050 - Flow mgd 0.006 NC0085731 2 2 2018 50050 - Flow mgd 0.007 NC0085731 2 6 2018 50050 - Flow mgd 0.008 NC0085731 2 14 2018 50050 - Flow mgd 0.008 NC0085731 2 23 2018 50050 - Flow mgd 0.008 NC0085731 2 26 2018 50050 - Flow mgd 0.008 NC0085731 3 5 2018 50050 - Flow mgd 0.007 NC0085731 3 6 2018 50050 - Flow mgd 0.007 NC0085731 3 7 2018 50050 - Flow mgd 0.007 NC0085731 3 8 2018 50050 - Flow mgd 0.007 NC0085731 3 13 2018 50050 - Flow mgd 0.007 NC0085731 3 19 2018 50050 - Flow mgd 0.007 NC0085731 3 27 2018 50050 - Flow mgd 0.008 NC0085731 4 3 2018 50050 - Flow mgd 0.007 NC0085731 4 11 2018 50050 - Flow mgd 0.009 NC0085731 4 17 2018 50050 - Flow mgd 0.008 NC0085731 4 26 2018 50050 - Flow mgd 0.008 NC0085731 5 2 2018 50050 - Flow mgd 0.009 NC0085731 5 9 2018 50050 - Flow mgd 0.009 NC0085731 5 15 2018 50050 - Flow mgd 0.009 NC0085731 5 21 2018 50050 - Flow mgd 0.009 NC0085731 5 30 2018 50050 - Flow mgd 0.009 NC0085731 6 4 2018 50050 - Flow mgd 0.01 NC0085731 6 5 2018 50050 - Flow mgd 0.01 NC0085731 6 6 2018 50050 - Flow mgd 0.01 NC0085731 6 7 2018 50050 - Flow mgd 0.01 NC0085731 6 12 2018 50050 - Flow mgd 0.01 NC0085731 6 18 2018 50050 - Flow mgd 0.01 NC0085731 6 29 2018 50050 - Flow mgd 0.01 NC0085731 7 5 2018 50050 - Flow mgd 0.012 NC0085731 7 11 2018 50050 - Flow mgd 0.012 NC0085731 7 18 2018 50050 - Flow mgd 0.009 NC0085731 7 26 2018 50050 - Flow mgd 0.013 NC0085731 8 2 2018 50050 - Flow mgd 0.011 NC0085731 8 8 2018 50050 - Flow mgd 0.011 NC0085731 8 14 2018 50050 - Flow mgd 0.012 NC0085731 8 24 2018 50050 - Flow mgd 0.011 NC0085731 8 28 2018 50050 - Flow mgd 0.011 NC0085731 9 3 2018 50050 - Flow mgd 0.011 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 mgd 0.01 NC0085731 9 5 2018 50050 - Flow mgd 0.011 NC0085731 9 6 2018 50050 - Flow mgd 0.011 NC0085731 9 11 2018 50050 - Flow mgd 0.01 NC0085731 9 13 2018 50050 - Flow mgd 0.01 NC0085731 9 19 2018 50050 - Flow mgd 0.018 NC0085731 9 27 2018 50050 - Flow mgd 0.014 NC0085731 10 4 2018 50050 - Flow mgd 0.013 NC0085731 10 9 2018 50050 - Flow mgd 0.013 NC0085731 10 18 2018 50050 - Flow mgd 0.014 NC0085731 10 24 2018 50050 - Flow mgd 0.014 NC0085731 10 29 2018 50050 - Flow mgd 0.014 NC0085731 11 7 2018 50050 - Flow mgd 0.015 NC0085731 11 14 2018 50050 - Flow mgd 0.015 NC0085731 11 19 2018 50050 - Flow mgd 0.016 NC0085731 11 26 2018 50050 - Flow mgd 0.015 NC0085731 12 4 2018 50050 - Flow mgd 0.015 NC0085731 12 11 2018 50050 - Flow mgd 0.016 NC0085731 12 13 2018 50050 - Flow mgd 0.018 NC0085731 12 20 2018 50050 - Flow mgd 0.017 NC0085731 12 28 2018 50050 - Flow mgd 0.017 NC0085731 1 4 2019 50050 - Flow mgd 0.017 NC0085731 1 7 2019 50050 - Flow mgd 0.018 NC0085731 1 8 2019 50050 - Flow mgd 0.018 NC0085731 1 14 2019 50050 - Flow mgd 0.017 NC0085731 1 15 2019 50050 - Flow mgd 0.017 NC0085731 1 16 2019 50050 - Flow mgd 0.018 NC0085731 1 17 2019 50050 - Flow mgd 0.017 NC0085731 1 24 2019 50050 - Flow mgd 0.017 NC0085731 1 31 2019 50050 - Flow mgd 0.018 NC0085731 2 4 2019 50050 - Flow mgd 0.017 NC0085731 2 12 2019 50050 - Flow mgd 0.019 NC0085731 2 22 2019 50050 - Flow mgd 0.025 NC0085731 2 27 2019 50050 - Flow mgd 0.029 NC0085731 3 4 2019 50050 - Flow mgd 0.028 NC0085731 3 5 2019 50050 - Flow mgd 0.029 NC0085731 3 6 2019 50050 - Flow mgd 0.029 NC0085731 3 7 2019 50050 - Flow mgd 0.024 NC0085731 3 11 2019 50050 - Flow mgd 0.021 NC0085731 3 15 2019 50050 - Flow mgd 0.022 NC0085731 3 20 2019 50050 - Flow mgd 0.022 NC0085731 3 26 2019 50050 - Flow mgd 0.023 NC0085731 4 3 2019 50050 - Flow mgd 0.028 NC0085731 4 10 2019 50050 - Flow mgd 0.025 NC0085731 4 15 2019 50050 - Flow mgd 0.024 NC0085731 4 26 2019 50050 - Flow mgd 0.023 NC0085731 4 30 2019 50050 - Flow mgd 0.022 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 mgd 0.021 NC0085731 5 15 2019 50050 - Flow mgd 0.022 NC0085731 5 24 2019 50050 - Flow mgd 0.022 NC0085731 5 30 2019 50050 - Flow mgd 0.022 NC0085731 6 6 2019 50050 - Flow mgd 0.022 NC0085731 6 10 2019 50050 - Flow mgd 0.022 NC0085731 6 11 2019 50050 - Flow mgd 0.023 NC0085731 6 12 2019 50050 - Flow mgd 0.022 NC0085731 6 13 2019 50050 - Flow mgd 0.022 NC0085731 6 17 2019 50050 - Flow mgd 0.022 NC0085731 6 25 2019 50050 - Flow mgd 0.022 NC0085731 7 2 2019 50050 - Flow mgd 0.021 NC0085731 7 8 2019 50050 - Flow mgd 0.02 NC0085731 7 15 2019 50050 - Flow mgd 0.02 NC0085731 7 23 2019 50050 - Flow mgd 0.02 NC0085731 7 30 2019 50050 - Flow mgd 0.02 NC0085731 8 8 2019 50050 - Flow mgd 0.021 NC0085731 8 13 2019 50050 - Flow mgd 0.021 NC0085731 8 20 2019 50050 - Flow mgd 0.022 NC0085731 8 26 2019 50050 - Flow mgd 0.02 NC0085731 9 5 2019 50050 - Flow mgd 0.02 NC0085731 9 9 2019 50050 - Flow mgd 0.019 NC0085731 9 10 2019 50050 - Flow mgd 0.019 NC0085731 9 11 2019 50050 - Flow mgd 0.018 NC0085731 9 12 2019 50050 - Flow mgd 0.018 NC0085731 9 17 2019 50050 - Flow mgd 0.018 NC0085731 9 23 2019 50050 - Flow mgd 0.017 NC0085731 9 30 2019 50050 - Flow mgd 0.016 NC0085731 10 10 2019 50050 - Flow mgd 0.015 NC0085731 10 14 2019 50050 - Flow mgd 0.015 NC0085731 10 24 2019 50050 - Flow mgd 0.015 NC0085731 10 28 2019 50050 - Flow mgd 0.015 NC0085731 11 4 2019 50050 - Flow mgd 0.016 NC0085731 11 14 2019 50050 - Flow mgd 0.016 NC0085731 11 19 2019 50050 - Flow mgd 0.015 NC0085731 11 25 2019 50050 - Flow mgd 0.014 NC0085731 12 2 2019 50050 - Flow mgd 0.014 NC0085731 12 3 2019 50050 - Flow mgd 0.014 NC0085731 12 9 2019 50050 - Flow mgd 0.014 NC0085731 12 10 2019 50050 - Flow mgd 0.014 NC0085731 12 11 2019 50050 - Flow mgd 0.013 NC0085731 12 12 2019 50050 - Flow mgd 0.014 NC0085731 12 16 2019 50050 - Flow mgd 0.014 NC0085731 12 23 2019 50050 - Flow mgd 0.015 NC0085731 1 3 2020 50050 - Flow mgd 0.016 NC0085731 1 8 2020 50050 - Flow mgd 0.016 NC0085731 1 14 2020 50050 - Flow mgd 0.016 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 mgd 0.016 NC0085731 1 28 2020 50050 - Flow mgd 0.016 NC0085731 2 7 2020 50050 - Flow mgd 0.016 NC0085731 2 12 2020 50050 - Flow mgd 0.017 NC0085731 2 17 2020 50050 - Flow mgd 0.017 NC0085731 2 27 2020 50050 - Flow mgd 0.017 NC0085731 3 2 2020 50050 - Flow mgd 0.017 NC0085731 3 4 2020 50050 - Flow mgd 0.017 NC0085731 3 9 2020 50050 - Flow mgd 0.017 NC0085731 3 10 2020 50050 - Flow mgd 0.017 NC0085731 3 11 2020 50050 - Flow mgd 0.017 NC0085731 3 12 2020 50050 - Flow mgd 0.017 NC0085731 3 16 2020 50050 - Flow mgd 0.016 NC0085731 3 23 2020 50050 - Flow mgd 0.016 NC0085731 3 30 2020 50050 - Flow mgd 0.016 NC0085731 4 6 2020 50050 - Flow mgd 0.016 NC0085731 4 13 2020 50050 - Flow mgd 0.016 NC0085731 4 20 2020 50050 - Flow mgd 0.006 NC0085731 4 27 2020 50050 - Flow mgd 0.007 NC0085731 5 4 2020 50050 - Flow mgd 0.02 NC0085731 5 11 2020 50050 - Flow mgd 0.017 NC0085731 5 18 2020 50050 - Flow mgd 0.012 NC0085731 5 26 2020 50050 - Flow mgd 0.014 NC0085731 6 1 2020 50050 - Flow mgd 0.014 NC0085731 6 2 2020 50050 - Flow mgd 0.031 NC0085731 6 3 2020 50050 - Flow mgd 0.02 NC0085731 6 4 2020 50050 - Flow mgd 0.019 NC0085731 6 8 2020 50050 - Flow mgd 0.019 NC0085731 6 15 2020 50050 - Flow mgd 0.019 NC0085731 6 25 2020 50050 - Flow mgd 0.019 NC0085731 7 1 2020 50050 - Flow mgd 0.022 NC0085731 7 7 2020 50050 - Flow mgd 0.015 NC0085731 7 16 2020 50050 - Flow mgd 0.019 NC0085731 7 24 2020 50050 - Flow mgd 0.018 NC0085731 8 1 2020 50050 - Flow mgd 0.018 NC0085731 8 5 2020 50050 - Flow mgd 0.018 NC0085731 8 12 2020 50050 - Flow mgd 0.017 NC0085731 8 18 2020 50050 - Flow mgd 0.017 NC0085731 8 25 2020 50050 - Flow mgd 0.018 NC0085731 3 3 2015 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 6 4 2015 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 9 2 2015 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 12 8 2015 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 3 3 2016 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 6 9 2016 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 9 15 2016 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 12 8 2016 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6` u hIoroethene ug/I 0.5 LESSTHAN NC0085731 6 8 2017 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 9 12 2017 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 12 5 2017 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 3 6 2018 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 6 4 2018 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 9 4 2018 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 1 16 2019 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 3 5 2019 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 6 11 2019 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 9 12 2019 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 12 2 2019 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 3 4 2020 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 6 2 2020 78389 - Tetrachloroethene ug/I 0.5 LESSTHAN NC0085731 3 3 2015 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 3 5 2015 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 6 2 2015 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 6 4 2015 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 9 15 2015 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 9 17 2015 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 12 8 2015 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 12 10 2015 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 3 1 2016 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 6 9 2016 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 9 15 2016 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 12 8 2016 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 3 9 2017 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 6 8 2017 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 9 12 2017 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 12 7 2017 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 3 8 2018 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 6 5 2018 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 9 4 2018 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 1 15 2019 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 3 5 2019 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 6 11 2019 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 9 10 2019 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 12 10 2019 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 3 10 2020 TGP3B - Pass/Fail Chronic pass/fail 1 NC0085731 6 3 2020 TGP3B - Pass/Fail Chronic pass/fail 1 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 No NC WQ standard LESSTHAN REPORTING ERROR? IDo1-c1u.S1.ig11n. Envelope ID: 16A577F0-987D- 4F2A-B7AE-CDD72DF893C6v.ATION PARAMETER VIOLATION DATE FREQUENCY NC0085731 12 2018 001 Effluent Iron, Total (as Fe) 12/31/2018 Quarterly NC0085731 12 2018 001 Effluent Pass/Fail Static Renewal 7Day Chronic Ceriodaphnia 12/31/2018 Quarterly NC0085731 12 2018 001 Effluent Tetrachloroethene 12/31/2018 Quarterly NC0085731 12 2018 001 Effluent Manganese, Total (as Mn) 12/31/2018 Quarterly DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 ,,JER VIOLATION TYPE mg/I Frequency Violation pass/fail Frequency Violation ug/I Frequency Violation mg/I Frequency Violation VIOLATION ACTION No Action, BPJ No Action, BPJ No Action, BPJ No Action, BPJ DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Failure to monitor as per permit due to equipment failure. Failure to monitor as per permit due to equipment failure. Failure to monitor as per permit due to equipment failure. Failure to monitor as per permit due to equipment failure. Monitoring occurred in January 2019, Monitoring occurred in January 2019, Monitoring occurred in January 2019, Monitoring occurred in January 2019, but is still technically a violation of the permit. but is still technically a violation of the permit. but is still technically a violation of the permit. but is still technically a violation of the permit. DocuSign Envelope ID: 16A577F0-987 D-4F2A-B7A E-C D D72D F893C6 edward.watson edward.watson edward.watson edward.watson 3/7/2019 5:02:29 PM 3/7/2019 5:02:29 PM 3/7/2019 5:02:29 PM 3/7/2019 5:02:29 PM DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Water Resource; LNVIRONtAtiNT AL QUAD'. Y January 29, 2016 Mr. Jesse Amundson, Hines Manager Hines 227 W. Trade Street, Suite 330 Charlotte, NC 28202 I'A"I MCCRORY 1)ONA1,-t) R. VAN [)FIR VAAR[ S. JAY ZIMMERMAN RECEIVED/NCDE(,YDWR FEB 0 2 2016 Water Quality Permitting Section Subject: Compliance Evaluation Inspection Carillion ground water remediation NPDES Permit No. NC0085731 Mecklenburg County Dear Mr. Amundson: Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted at the subject facility on January 27, 2016 by Ori Tuvia and Ed Watson. Your representative David Jarvis cooperation during the site visit was much appreciated. Please advise the staff involved with this NPDES Permit by forwarding a copy of the enclosed report. As was discussed on site,only mark Chronic Toxicity results for the dates mentioned on Toxicity reports. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at ori.tuvia@ncdenr.gov. Sincerely, Ori Tuvia, Environmental Engineer Mooresville Regional Office Division of Water Resources, DEQ Cc: NPDES (Derek Denard) MRO Files Mooresville Regional office Location: 610 East Center Ave., Suite 301 Mooresville. NC 28115 Phone: (704) 663-1699 \ Fax: (704) 663-6040 \ Customer Service: 1-877-623-6748 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 f United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 1,,, I 2 IS I 3 1 NC0085731 111 12 I 16/01/27 117 Type 18 LI I I I I I Inspector Fac Type 19 (S I 201 I 6 21 I I I I I I I I I I I I I 1 1 I I I I I I I I I I I I I I I I 1 l I I I 1�6 l Inspection Work Days Facility Setf-Monitoring Evaluation Rating B1 QA Reserved 67 11.0 I 70 LJ Id I 71 IN 172 I N I 731174751 1 1 1 1 1 1 1 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Carillon Building 227 W Trade St Charlotte NC 28202 Entry Time/Date 09:45AM 16/01/27 Permit Effective Date 15/09/01 Exit Time/Date 11:15AM 16/01/27 Permit Expiration Date 20/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// David Jarvis//704-719-1100 / Travis Quinn//704-995-5481 / Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Flora Jane D'Souza,9751 Southern Pines Blvd Charlotte NC 28273/// No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Edward Watson MRO GW/// Ori A Tuvia MRO WQ//704-663-1699/ --- _-- -•j / Z. Ci / I G Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date William C Basinger MRO WQ//704-235-2194/ EPA Fo �6 --3 (Rev 9-9 Previous editions are obsolete. tici>k, pvir a. y, 0/ _ -• 1 L. Page# 1 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 31 NPDES NC0085731 I11 121 yr/mo/day 16/01/27 17 Inspection Type 18I,.1 (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Notes writen by Ed Watson. The Quarterly report of groundwater contaminants indicate there are currently exceedance for Manganese (Mn) of 17.2 ug/L, 1,2- DCE AT 100 UG/I, 4- Bromoflurobenzene at 100 ug/L and Toluene at 101 ug/L. Although these constituents are above the 2L standard for groundwater, they are reduced from previously report groundwater laboratory results indicating, the system is operating to reduce VOC impact to groundwater. The waste carbon is extracted through an extraction port that is connected to the top of the Carbon canister to allow for easy extraction of the spent Carbon. The system is set up as an in -line two canister system which allows one tank to perform extraction of solids and the second tank to act as a polishing tank. The system is reversible to allow for the tanks to be reversed to allow for extraction of the spent Carbon in the lead tank making the second tank the primary tank. The system has sample ports that allow for mid -point sampling which helps with monitoring breakthrough of constituents in the activated Carbon in the vessels. A copy of the spent Carbo Manifest was provided to see the spent Carbon was being properly disposed of by Evoqua and a copy of the 10/28/2015 manifest was provided. The files were up to date and in order. Samples are able to be extracted at the mid -point of the in -line tanks and at the end of the treatment. Because the travel distance of the system drain line, we were not able to view out -flow that empties into the un-named tributary to Erwin's Creek. Page# 2 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 r 1 Permit: NC0085731 Inspection Date: 01/27/2016 Owner - Facility: Carillon Building Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 application? Is the facility as described in the permit? •❑ ❑ ❑ # Are there any special conditions for the permit? ❑ • ❑ ❑ Is access to the plant site restricted to the general public? • 0 0 0 Is the inspector granted access to all areas for inspection? 0 0 0 Comment: Special condition for ground water remediation pump and treat system. require to sample, Flow, Tetraethlene, Iron, Manganese, and Chronic toxicity. Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Yes No NA NE ▪ ❑ ❑ ❑ ▪ ❑ ❑ ❑ • ❑ ❑ ❑ 11 ❑ ❑ ❑ ■ ❑❑❑ • • • II ❑ ❑ ❑ ❑ ❑ � ❑ ❑ ❑ I ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ ❑ ❑ ❑ ❑ ❑ ❑ Comment: Records are well maintained. the facility has been marking their Chronic Toxcitv results wrong will correct. Effluent Sampling Is composite sampling flow proportional? Yes No NA NE • ❑ ❑ ❑ Page# 3 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Permit: NC0085731 Inspection Date: 01/27/2016 Owner - Facility: Carillon Building Inspection Type: Compliance Evaluation Effluent Sampling Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at Tess than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Yes No NA NE • ❑ ❑ ❑ • ❑❑❑ ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Composite Sampling done by ISCO sampling machine which was not on site at the time of the inspection. ORC bring the sampler when needed. Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE 11 ❑ ❑ ❑ ▪ ❑ ❑ ❑ II ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ Cl ❑ ❑■❑ Comment: PACE laboratory analyze samples for Tetraethlene, Iron and Manganese. ETS laboratory analyze chronic toxicity sampling. Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Flow meter is replaced yearly. Yes No NA NE 11000 ❑ • ❑ ❑ II ❑ ❑ ❑ •❑ ❑ ❑ Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable 0 ❑ • Cl Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: 8 recovery wells pump into a 10,000 gallon equalization tank, transferring into two charcoal filters. Charcoal is replaced once a year by Haz-Met Environmental services. Page# 4 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 PAT MCCRORY Governor DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN Director Water Resources ENVIRONMENTAL QUALITY September 21, 2016 KBSIII Carillon, LLC c/o Hines Interests Limited Partnership 227 West Trade Street, Suite 330 Charlotte, NC 28202 Attn: General Manager Subject: Minor modification of NPDES Permit NC0085731 Carillon Building Dewatering System Mecklenburg County Dear Permittee: The Division has received and approved your request to transfer ownership of the subject Certificate of Coverage (CoC). As a result, the Division hereby reissues NC0085731. This CoC is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Insert the attached page into your permit and discard the old page. This modified permit includes the following changes from your current permit: ➢ Change of ownership from Hines Charlotte Carillon LP to KBS III Carillon, LLC, a Delaware limited liability company. If any parts, measurement frequencies or sampling requirements contained in this modification are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. This permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by any other Federal, State, or Local governmental regulation. If you have any questions concerning this matter, please contact Brianna Young at (919) 807- 6388 or via e-mail [brianna.young@ncdenr.gov]. Sincerely, S. Jay Zimmerman, Director Division of Water Resources cc: Central Files Mooresville Regional Office Complex and Expedited Permitting Unit State of North Carolina l Environmental Quality 1 Water Resources 1617 Mail Service Center l Raleigh, NC 27699-1617 919 807 6300 919-807-6389 FAX hops://deq.nc.gov/about/divisions/water-resources/water-resources-permits/wastewater-branch/npdes-wastewater-permits DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Permit NC0085731 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, KBS III Carillon, LLC, a Delaware limited liability company is hereby authorized to discharge wastewater from a facility located at The Carillon Building dewatering system 227 West Trade Street Charlotte Mecklenburg County to receiving waters designated as an unnamed tributary [storm sewer] to Irwin Creek in subbasin 03-08-34 of the Catawba River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective September 28, 2016. This permit and authorization to discharge shall expire at midnight on June 30, 2020. Signed this day September 28, 2016. S. Jay Zimmerman, Director Division of Water Resources By Authority of the Environmental Management Commission Page 1 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Permit NC0085731 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility, whether for operation or discharge are hereby revoked. As of this permit issuance, any previously issued permit bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements, terms, and provisions included herein. KBS III Carillon, LLC is hereby authorized to: 1. Continue to operate an existing 0.0316 MGD wastewater treatment system that includes the following components: ♦ Surge tank ♦ Two carbon absorption units The facility is located at The Carillon Building (227 West Trade Street, Charlotte) in Mecklenburg County. 2. Discharge from said treatment works at the location specified on the attached map into a storm sewer to Irwin Creek, currently classified C waters in the Catawba River Basin. Page 2 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Permit NC0085731 Part I A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS [15A NCAC 02B.0400 et seq., 15A NCAC 02B.0500 et seq.] During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored' by the Permittee as specified below: PARAMETER [PCS Code] LIMITS MONITORING REQUIREMENTS Monthly Average Weekly Average Daily Maximum Measurement Frequency Sample Type Sample Location Flow2 [50050] 0.0316 MGD Monthly Instantaneous Effluent Tetrachloroethene [78389] 3.3 pg/L Quarterly Grab Effluent Iron [01045] Quarterly Grab Effluent Manganese [01055] Quarterly Grab Effluent Chronic Toxicity3 [TGP3B] Quarterly Composite Effluent Footnotes: 1. No later than 270 days from the effective date of this permit, the permittee shall begin submitting discharge monitoring reports electronically using the Division's eDMR system [see A. (3)]. 2. All volumes of wastewater leaving the facility shall be monitored. If continuous flow monitoring is not feasible, then the discharger shall record the approximate time that discharge began and ended, along with the instantaneous flow at the time of the effluent sampling. 3. Refer to A. (2)). There shall be no discharge of floating solids or visible foam in other than trace amounts. A. (2) CHRONIC TOXICITY PERMIT LIMIT (Quarterly) [15A NCAC 02B.0200 et seq.] The effluent discharge shall at no time exhibit observable inhibition of reproduction or significant mortality to Ceriodaphnia dubia at an effluent concentration of 90%. The permit holder shall perform at a minimum, quarterly monitoring using test procedures outlined in the "North Carolina Ceriodaphnia Chronic Effluent Bioassay Procedure," Revised December 2010, or subsequent versions or "North Carolina Phase II Chronic Whole Effluent Toxicity Test Procedure" (Revised- December 2010) or subsequent versions. The tests will be performed during the months of March, June, September, and December. These months signify the first month of each (three-month) toxicity testing quarter assigned to the facility. Effluent sampling for this testing must be obtained during representative effluent discharge and shall be performed at the NPDES permitted final effluent discharge below all treatment processes. Page 3 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Permit NC0085731 If the test procedure performed as the first test of any single quarter results in a failure or ChV below the permit limit, then multiple -concentration testing shall be performed at a minimum, in each of the two following months as described in "North Carolina Phase II Chronic Whole Effluent Toxicity Test Procedure" (Revised -December 2010) or subsequent versions. All toxicity testing results required as part of this permit condition will be entered on the Effluent Discharge Monitoring Form (MR-1) for the months in which tests were performed, using the parameter code TGP3B for the pass/fail results and THP3B for the Chronic Value. Additionally, DWR Form AT-3 (original) is to be sent to the following address: Attention: North Carolina Division of Water Resources Water Sciences Section/Aquatic Toxicology Branch 1623 Mail Service Center Raleigh, NC 27699-1623 Completed Aquatic Toxicity Test Forms shall be filed with the Water Sciences Section no later than 30 days after the end of the reporting period for which the report is made. Test data shall be complete, accurate, include all supporting chemical/physical measurements and all concentration/response data, and be certified by laboratory supervisor and ORC or approved designate signature. Total residual chlorine of the effluent toxicity sample must be measured and reported if chlorine is employed for disinfection of the waste stream. Should there be no discharge of flow from the facility during a month in which toxicity monitoring is required, the permittee will complete the information located at the top of the aquatic toxicity (AT) test form indicating the facility name, permit number, pipe number, county, and the month/year of the report with the notation of "No Flow" in the comment area of the form. The report shall be submitted to the Water Sciences Section at the address cited above. Should the permittee fail to monitor during a month in which toxicity monitoring is required, monitoring will be required during the following month. Assessment of toxicity compliance is based on the toxicity testing quarter, which is the three month time interval that begins on the first day of the month in which toxicity testing is required by this permit and continues until the final day of the third month. Should any test data from this monitoring requirement or tests performed by the North Carolina Division of Water Resources indicate potential impacts to the receiving stream, this permit may be re -opened and modified to include alternate monitoring requirements or limits. NOTE: Failure to achieve test conditions as specified in the cited document, such as minimum control organism survival, minimum control organism reproduction, and appropriate environmental controls, shall constitute an invalid test and will require immediate follow-up testing to be completed no later than the last day of the month following the month of the initial monitoring. Page 4 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Permit NC0085731 A. (3) ELECTRONIC REPORTING OF DISCHARGE MONITORING REPORTS [NCGS 143-215.1 (b)] Proposed federal regulations require electronic submittal of all discharge monitoring reports (DMRs) and specify that, if a state does not establish a system to receive such submittals, then permittees must submit DMRs electronically to the Environmental Protection Agency (EPA). The Division anticipates that these regulations will be adopted and is beginning implementation. NOTE: This special condition supplements or supersedes the following sections within Part II of this permit (Standard Conditions for NPDES Permits): • Section B. (11.) • Section D. • Section D. • Section E. (2.) (6.) (5.) Signatory Requirements Reporting Records Retention Monitoring Reports 1. Reporting [Supersedes Section D. (2.) and Section E. (5.) (a)] Beginning no later than 270 days from the effective date of this permit, the permittee shall begin reporting discharge monitoring data electronically using the NC DWR's Electronic Discharge Monitoring Report (eDMR) internet application. Monitoring results obtained during the previous month(s) shall be summarized for each month and submitted electronically using eDMR. The eDMR system allows permitted facilities to enter monitoring data and submit DMRs electronically using the internet. Until such time that the state's eDMR application is compliant with EPA's Cross -Media Electronic Reporting Regulation (CROMERR), permittees will be required to submit all discharge monitoring data to the state electronically using eDMR and will be required to complete the eDMR submission by printing, signing, and submitting one signed original and a copy of the computer -printed eDMR to the following address: NC DENR / Division of Water Resources / Information Processing Unit ATTENTION: Central Files / eDMR 1617 Mail Service Center Raleigh, NC 27699-1617 If a permittee is unable to use the eDMR system due to a demonstrated hardship or due to the facility being physically located in an area where less than 10 percent of the households have broadband access, then a temporary waiver from the NPDES electronic reporting requirements may be granted and discharge monitoring data may be submitted on paper DMR forms (MR 1, 1.1, 2, 3) or alternative forms approved by the Director. Duplicate signed copies shall be submitted to the mailing address above. Requests for temporary waivers from the NPDES electronic reporting requirements must be submitted in writing to the Division for written approval at least sixty (60) days prior to the date the facility would be required under this permit to begin using eDMR. Temporary waivers shall be valid for twelve (12) months and shall thereupon expire. At Page 5 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 Permit NC0085731 such time, DMRs shall be submitted electronically to the Division unless the permittee re- applies for and is granted a new temporary waiver by the Division. Information on eDMR and application for a temporary waiver from the NPDES electronic reporting requirements is found on the following web page: http://portal.ncdenr.org/web/wq/admin/bog/ipu/edmr Regardless of the submission method, the first DMR is due on the last day of the month following the issuance of the permit or in the case of a new facility, on the last day of the month following the commencement of discharge. 2. Signatory Requirements [Supplements Section B. (11.) (b) and supersedes Section B. (11.) (d)1 All eDMRs submitted to the permit issuing authority shall be signed by a person described in Part II, Section B. (11.)(a) or by a duly authorized representative of that person as described in Part II, Section B. (11.)(b). A person, and not a position, must be delegated signatory authority for eDMR reporting purposes. For eDMR submissions, the person signing and submitting the DMR must obtain an eDMR user account and login credentials to access the eDMR system. For more information on North Carolina's eDMR system, registering for eDMR and obtaining an eDMR user account, please visit the following web page: http://portal.ncdenr.org/web/wq/admin/bog/ipu/edmr Certification. Any person submitting an electronic DMR using the state's eDMR system shall make the following certification [40 CFR 122.22]. NO OTHER STATEMENTS OF CERTIFICATION WILL BE ACCEPTED: "7 certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 3. Records Retention [Supplements Section D. (6.11 The permittee shall retain records of all Discharge Monitoring Reports, including eDMR submissions. These records or copies shall be maintained for a period of at least 3 years from the date of the report. This period may be extended by request of the Director at any time [40 CFR 122.41]. Page 6 of 6 DocuSign Envelope ID: 16A577F0-987D-4F2A-B7AE-CDD72DF893C6 The Carillon Latitude: 35° 13'39" Longitude: 80°50' 14" USGS Quad: Charlotte Receiving Stream: Irwin NC0085731 Building dewatering system Stream Class: C Subbasin: 30834 East, N.C. Creek Facility Location Mecklenburg County Map not to scale