Loading...
HomeMy WebLinkAboutNC0037508_Compliance Biomonitoring_20070309William U. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality • March 9, 2007 Marcus Jones Moore Cotinty Public Works Director P. O. Box 1927. Carthage, NC 28327 Subject: Correction to February 26, 2007 Letter COMPLIANCE BIOMONITORING INSPECTION COMPLIANCE SAMPLING RESULTS Moore County Water Pollution Control Plant NPDES Permit No. NC0037508 Moore County Dear Mr. Jones: Concerning the BOD laboratory analysis for the sample that was collected on January23, the sample results that I sent to you in the report dated February 26, 2007 was in error as to the BOD testing laboratory for the Moore County sample. The Moore County Water Pollution Control Plant laboratory performed it rather than Meritech as stated in the report. . Please attach this correction letter to the February 26, 2007 report. I am sorry for any inconvenience that this may have caused. If you have any questions or comments concerning this letter, please feel free to contact me at (910) 433-3312. cc: Dale Lopez Environmental Specialist James Delmo Frye, Moore County ORC Jana Scherer, Moore County WPCF Laboratory Supervisor North Carolina Division of Water Quality Internet ncwaterquality.org An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper ""o N�ttCarolina aturally 225 Green Street - Suite 714 Fayetteville, NC 28301-5043 Phone (910) 433-3300 Customer Service FAX (910) 486-0707 1-877-623-6748 Michael F. Easley, Governor Williarn G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources February 26, 2007 Marcus Jones Moore County Public Works Director P. O. Box 1927 Carthage, NC 28327 Subject: COMPLIANCE BIOMONITORING INSPECTION COMPLIANCE SAMPLING RESULTS Moore County Water Pollution Control Plant NPDES Permit No. NC0037508 Moore County Dear Mr. Jones: Alan W. Klimek, P.E., Director Division of Water Quality Concerning the laboratory analyses for samples that were collected during the week of the January 22, 2007 Biomonitoring Inspection, the results of the laboratory parameters are as follows: Total Suspended Solids = 7.0 mg/L, Biochemical Oxygen Demand = 29 mg/L, NH3 as N = 0.05 mg/L, TKN as N = 1.8 mg/L, NO2 plus NO3 as N = 14 mg/L, and P as P = 2.8 mg/L. In addition, the Ceriodaphnia Chronic Multiple dilution toxicity samples that were collected during the same week resulted in a 100%. They were sent to the Division of Water Quality Aquatic Toxicology Laboratory (located on Reedy Creek Road in Raleigh). For additional information, please refer to the Compliance Biomonitoring Inspection report, dated February 8, 2007. Due to a discrepancy in the. Whole Effluent Toxicity (WET) results between the two laboratories (Meritech, Inc. at 29%, and the Division of Water Quality Aquatic Toxicology Laboratory at 100%), the Whole Effluent Toxicity samples that were collected by Moore County WPCF sampling equipment on January 23 and January 26 will not be considered as a true split because of the following two reasons: 1. the actual pouring into the cubitainers of Friday's 24-hour composite WET samples on January 26 were performed at different times and with different mixing conditions, and 2. the percentages used in the dilution series were not the same for the two laboratories: Meritech (10.25, 20.5, 41, 82, and 100%) and DWQ (15, 21, 41, 70, and 100%). In addition, there was a discrepancy in the Biochemical Oxygen Demand (BOD) results between Meritech, Inc. (BOD = 9.4 mg/L) and the DWQ laboratory (BOD = 29 mg/L). These samples were taken from two different 24-hour composite samplers that started and finished at the same time, from January 22nd to 23rd. The reasons for the discrepancies of the BOD and the WET are being investigated. We hope that the rationale and any corrective actions will yield beneficial results for the wastewater treatment plant. NotihCarolina Naturally North Carolina Division of Water Quality 225 Green Street — Suite 714 Fayetteville, NC 28301-5043 Phone (910) 433-3300 Customer Service Internet: ncwaterquality.org FAX (910) 486-0707 1-877-623-6748 An Equal opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper Mr. Jones Page 2 February 26, 2007 If you have any questions or comments concerning this report, please feel free to contact me at (910) 433-3312. Sincerely, Dale Lopez Environmental Specialist 3 cc: James Delmo Frye, Moore County ORC Jana Scherer, Moore County WPCF Laboratory Supervisor Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality February 8, 2007 Marcus Jones Moore County Public Works Director P. O. Box 1927 Carthage, NC 28327 Subject: COMPLIANCE BIOMONITORING INSPECTION Moore.County Water Pollution Control Plant NPDES Permit No. NC0037508 Moore County Dear Mr. Jones:' Enclosed you will find a copy of the Compliance Biomonitoring Inspection report for the inspection conducted the week of January 22, 2007. The inspection included the same objectives as that of a routine Compliance Evaluation Inspection plus an Aquatic Toxicity (AT) test to evaluate the biological effect of the facility's discharge on test organisms. The Whole Effluent Toxicity samples that were collected by Moore County WPCF sampling equipment on January 23 and January 26 were split between your facility's laboratory (Meritech, Inc.). and the Division of Water Quality Aquatic Toxicology Laboratory (located on Reedy Creek Road in Raleigh). The results will be sent to you when they._are completed. In addition, a 001. effluent composite sample .was collected by DWQ's sampling equipment at Outfall 001 on January 23 for the following parameters (which are currently in your NPDES Permit): Total Phosphorus, Ammonia as N, Nitrate as N, Nitrite as N, TKN as N, Total Suspended Solids, and five-day Biochemical Oxygen Demand. The results of these laboratory parameters will be forwarded to you when the Division of Water Quality Chemistry Laboratory, located on Reedy Creek Road in Raleigh, completes the analyses. As part of the inspection a tour of the Wastewater Treatment Plant was conducted. All observations are in Part D. Summary of Findings/Comments of this inspection report. It is recommended that the cleaning procedure enclosed with this report be used for cleaning new tubing and the composite sampler container. If you have any questions or comments concerning this report or require clarification on part(s) of this report, please feel free to contact me at (910) 433-3312. Sincerely, Dale Lopez Environmental Specialist cc: James Delmo Frye, ORC Enclosures: EPA Water Compliance Inspection Report Regional Field Inspectors Check List for Field Parameters Composite Sampler Cleaning Procedure (tubing & sampler) NorthCarolina Naturally North Carolina Division of Water Quality 225 Green Street - Suite 714 Fayetteville, NC 28301-5043 Phone (910) 433-3300 Customer Service FAX (910) 486-0707 1-877-623-6748 Internet: ncwaterquality.org An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper United States Environmental Protection A9ency EPA Washington, D.C. 20460 Water Compliance Inspection Report . Forrn Approved: OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES • yr/mo/day Inspection. 1 I_JI 2 51 31 NC003 750;8 1 11 121 07/01/22 117 Type Inspector Fac Type 181 8 1 1911 s l 201 LI I 1 1 1 1 1 1 I. 1 1 1 1 1 1 166 Remarks 211 I I I I 1 I I I I I I 11 1 I I 1 I 1 1.1 1 1 I 1 1 1 I I I 1 I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 4.0 169 701.41 71 II 721 ,;I 731 I 174 751 1 1 1 1 1 1 1 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Moore County WPC: 1060 Addor Rd Aberdeen NC 28315 Entry Time/Date 10:00 Aid 07/01/22 Permit Effective Date 05/07/01.. Exit Time/Date 04:00 PM 07/01/22 Permit Expiration Date 09/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Jeffery W Corder/ORC/910-281-3146/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Marcus A Jones,P0 Box 1927 Carthage NC 28327/Public Works D_.rect.o../t O Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance • Records/Reports Self -Monitoring Program • Sludge Handling Disposal • Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) '- (See attachment summary) Name(s) and Sign e(s) of Inspector(s) Agency/Office/Phone and Fax pale Lopez � iy FRO WQ/,•'910-43=-3300 Exz.7i2/ Numbers Date y/ 7 Signature of Management A Reviewer llI Agency/Office/Phone and Fax Numbers Date tg r,- 1/9/0 7 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES NCO037508 111 121 yr/mo/day. 07/01/22• Inspection Type 117 18IBI (cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and`checklists as necessary) The headworks pump station (Raw Sewage) Upgrade will consist of changing three pumps to four dry submersible pumps. The capacity of the "pump station will increase to 10 MGD (from the present 6.7 MGD). Also, a new mechanical bar screen will replace the manual bar screen. There will be a pump 'station bypass line (a spur to pump up to the grit chamber). The influent wet well will be cleaned of the grease. 30% liquid lime will replace the dry lime (silo). The POTW appeared to be in compliance with the requirements of the NPDES permit. Page # 2 Permit: NC0037508 Inspection Date: 01/22/2007. Owner • Facility: Moore County WPCF Inspection Type: Bioassay Compliance Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • Finn Does the facility analyze process, control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge • n n ❑ Judge, and other that are applicable? Comment: Permit Yes No NA NE _ (If the present permit expires in 6 months or less). Has the permittee submitted a new application? n n ■ n Is the facility as described in the permit? • n n n # Are there any special conditions for the permit? • min ❑, n Is access to the plant site restricted to the general public? - ■ n n n Is the inspector granted access to all areas for inspection? • n n n Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by.the permit? ■ n n n Is all required information readily available, complete and current? • n ❑ 0 Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ El El Are analytical results consistent with data reported on DMRs? • n ❑ n Is the chain -of -custody complete? • n n n Dates, times and location of sampling • Name of individual.performing the sampling Results of analysis and calibration • Dates of analysis Name of person; performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? ■ n n n Has the facility submitted its annual compliance report to users and DWQ? ■ n n n (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? • n El Is the ORC visitation log available and current? • n n n Is the ORC certified at grade equal to or higher than the facility classification? • n n ❑ Is the backup operator certified at one grade less or greater than the facility classification? O n ❑ n Is a copy of the current NPDES permit available on site? a n n n Page # 3 Permit: NC0037508 Owner- Facility: Moore County WPCF Inspection Date: 01/22/2007 Inspection Type: Bioassay Compliance Record Keeping Facility has copy of previous year's Annual Report on file for review? Comment: Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Flow Measurement - Influent' # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Anaerobic Digester Type of operation: Is the capacity adequate? # Is gas stored on site? Is the digester(s) free of tilting covers? Is the gas burner operational? Is the digester heated? Is the temperature maintained constantly? Is tankage available for properly waste sludge? Comment: Drying Beds Is there adequate drying bed space? Is the sludge distribution on drying beds appropriate? Are the drying beds free of vegetation? # Is the site free of dry sludge remaining in beds? Is the site free of stockpiled sludge? Is the filtrate from sludge drying beds returned to the front of the plant? Yes No NA ,NE nnn• Yes No NA NE • nnn ■ n'nn nn•n Yes No NA NE ■ nnn ■ nnn ■ nnn nnn■ Yes No NA NE Floating cover ■ nnn ■ nnn ■ nnn e nnn Erin n ■ nnn ■ nnn Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn n■nn ■ nnn Page # 4 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 01/22/2007 Inspection Type: Bioassay Compliance Drying Beds Yes No NA NE # Is the sludge disposed of through county landfill? • n n n # Is the sludge land applied? ■ n n n (Vacuum filters) Is polymer mixing adequate? n n ■ n Comment: Stockpiled in one drying bed until disposal date. Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? • n n n Is the screen free of excessive debris? • n n n is disposal of screening in compliance? • n n n Is the unit in good condition? ■ n n n Comment: Plans to put in a new mechanical bar screen and remove the manual bar screen. Grit Removal Yes No NA NE Type of grit removal a.Manual b.Mechanical Is the grit free of excessive organic matter? ® n n n Is the grit free of excessive odor? ■ n n n # Is disposal of grit in compliance? • ❑ ❑ ❑ Comment: Mechanical grit removal unit (hydrogriter) had not been operational for a long period of time, and there are no plans for repair. The grit is presently settled then the unit is drained and the grit is pumped by pump trucks and sent to the drying beds. Primary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • n n n Is the site free of excessive buildup of solids in center well of circular clarifier? 'inn n Are weirs level? • ❑ ❑ ❑ Is the site free of weir blockage? inn n Is the site free of evidence of short-circuiting? • n" n n Is scum removal adequate? ■ ❑ El ❑ Page # 5 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 01/22/2007 Inspection Type:.• Bioassay Compliance Primary Clarifier Is the site free of excessive floating sludge? Is the drive unit operational? Is the sludge blanket level acceptable? Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth) Comment: Secondary Clarifier Is the clarifier free,of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately % of the sidewall depth) Comment: Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/I) Comment: Standby Power Yes No NA NE En MR ▪ nnn • nnn ■ nnn Yes No NA NE ■ nnn ■ n n ■ nnn ■ nnn ■ nnn ■ nn0 ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn Yes No NA NE Diffused ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn Yes No NA NE Page # 6 Permit: NC0037508. Owner - Facility: Moore County WPCF Inspection Date: 01/22/2007. Inspection Type:. Bioassay Compliance Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? 'Was generator tested & operational during the inspection? Do the generator(s)have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: There is not an emergency agreement with the fuel vendor for extended run on back-up power. Disinfection -Gas Are cylinders secured adequately? Are cylinders protected from direct sunlight? Is there adequate reserve supply of disinfectant? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk. Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Yes No NA NE ■ nnn ■ nnn ■ nnn nnn■ ■ nnn n■nn ■nnn Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn .nnn ■ nnn nnn■= nn■n Yes No NA NE Gas ■ nnn ■ nnn ■ nnn n n■n n n■n Page # 7 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 01/22/2007 Inspection Type: Bioassay Compliance De -chlorination Comment: Laboratory Are field parameters performed by,certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? ;s proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set t0 20.0 degrees Celsius +1-1.0 degrees? Comment: Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Yes No NA NE Yes No NA NE ■ nnn 1nnn an ■ nnn ■ nnn ■ nnn Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nn.El ■ nnn ■ nnn Page # 8 • • Regional Field Inspectors Check List for Field Parameters Name of site to be Inspected: Moore County Water Pollution Control Plant Date:January.23, 2007 Field certification # (if applicable): 134 Inspector:D.ale Lopez NPDES #:NC0037508 Region: FRO I. Circle the parameter or parameters performed at this site. Residual Chlorine , Settleable Solids, pH, DO, Conductivity, Temperature II. Instrumentation:‘ A. Does the facility have the equipment necessary to analyze field parameters as circled above? 1. A pH meter 2. A Residual Chlorine meter 3. DO meter 4. A Cone for settleable solids 5. A thermometer or meter that measures temperature. 6. Conductivity meter Orion 920A+ HACH Odyssey III. Calibration/Analysis: 1. Is the pH meter calibrated with 2 buffers and checked with a third buffer each day of use? 2. For Total Residual Chlorine, is a check standard analyzed each day of use? 3. Is the air calibration of the DO meter performed each day of use? 4. For Settleable Solids, is 1 liter of sample settled for 1 hour? 5. Is the temperature measuring device calibrated annually against a certified thermometer? 6. For Conductivity, is a calibration standard analyzed each day of use? Yes Yes Yes No No No Yes No No No No No No Yes No No No Yes Yes Yes Yes Yes Yes Yes IV. Documentation: 1. Is the date and time that the sample was collected documented? 2. Is the sample site documented? 3. Is the sample collector documented? 4. Is the analysis date and time documented? 5. Did the analyst sign the documentation? 6. Is record of calibration documented? 7. For Settleable Solids, is sample volume and 1 .hour time settling .time documented? 8. For Temperature, is the annual calibration of the measuring device documented? Comments: Yes f {es Yes fes fres Yes Yes. Yes No No No No No No No No Please submit a copy of this completed form to the Laboratory Certification Program. DWQ Lab Certification Chemistry Lab Courier # 52-01-01 FIELD INSPECTOR CHECKLIST REV. 04/23/2002 Whole, Effluent Toxicity Sampling • Sampler Cleaning Procedure New tubing should be used for each site.•. It is not necessary to clean new tubing per the following instructions, but is recommended. The objective of the following procedure is to "bioassay clean" the internal peristaltic tubing and tubing strainer. A dedicated length of tubing can be set aside expressly for cleaning that will be of the minimum length necessary and therefore reduce the amounts of reagents required. 1. Draw hot soapy water into the sampler tubing until all tubing is full. Let stand for five minutes. Laboratory grade (non surfactant) detergent should be used for this purpose. ATU can supply this if necessary. Expelsoapy water. . 3. Flush tubing with at least 500 mis of distilled/de-ionized water. 4. Draw 5% trace metal grade nitric acid into the sampler tubing until all tubing is full. Let stand for three minutes. 5. Expel 5% nitric acid. 6. Flush tubing with at least 500 mis of distilled/de-ionized water. 7. Flush tubing with 500 misof 5% pesticide grade acetone. 8. Immediately flush tubing with at least one liter of distilled/de-ionized water. When setting up the sampler in the field, the apparatus should be flushed with at least one liter of sample prior to collection of the first sub sample. Compo.7hitt..jampier 04ezning Sea wu 1101, use te width distilled Irate sii nitric add lose Wilco with distilled wate Fins hoe with dilute acetone • Step us Rinse three thus with Minim water n. sample cleaning logbook