Loading...
HomeMy WebLinkAboutNC0037508_WWTP Inspection_20110627ATA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary July 5, 2011 Randy Gould, Public Works Director Moore County Public Utilities P.O. Box 1927 Carthage, NC 28327 SUBJECT: June 27, 2011 Compliance Evaluation Inspection Moore County Public Utilities Moore County WPCF Permit No: NC0037508 Moore County Dear Mr. Gould: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on June 27, 2011. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Chemist, and Belinda Henson, Regional Supervisor, of the Fayetteville Regional Office. The cooperation of Mr. George Yankay, Facility ORC, and Rex Downs, Lead Operator, was greatly appreciated. The facility was found to be in Compliance with permit NC0037508. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Comments • Facility was clean and neat in appearance at the time of the inspection. • The Division of Water Quality understands that the bidding portion of the planned upgrade is underway. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3327. Sincerely, Mark Brantley Environmental Specialist Surface Water Protection Section Fayetteville Regional Office cc: George R Yankay, ORC Central Files Fa yetteville_Files, (kmbJ Location: 225 Green Street, Suite 714, Fayetteville, NC 28301 Phone (910) 433-3300\FAX: 910-486-0707\Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org NorthCarolina Naturally An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 INI 2 15I' 31 NC0037508 111. 121 11/06/27 117 Type Inspector Fac Type 18I cI 191 SI 20I II Remarks 21I.II_IIIII1IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII66 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved-------- ------ ---- 67 I 169 70 13 I 711 NI 72 I N I 731 I 174 751 1 I I 1 I 1 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Moore County WPCF 1094 Addor Rd Aberdeen NC 28315 Entry Time/Date 09:45 AM 11/06/27 Permit Effective Date 10/12/01 Exit Time/Date 12:00 PM 11/06/27 Permit Expiration Date 14/07/31 Name(s) of OnsiteRepresentative(s)/Titles(s)/Phone and Fax Number(s) ///' George R Yankay/ORC/910-675-7.013/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Dennis L Brobst,PO Box 1927 Carthage NC 283271927/Public-Utilities ontacted Director/910-281-3146/9102812047 .No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program - • Facility Site Review Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspectors) Agency/Office/Phone and Fax Numbers Date Mark Brantley FRO WQ//910-433-3300 Ext.727/ `4",,I4A. 4i>_s--_// 1 Signature of Management Q/AA Reviewer f/ ,,� - �.� Agency/Office/Phone and Fax Numbers `Date / Belinda S Henson e�^L4.1 ,).115 �/ J' v - FRO WQ//910-433-3300 Ext.726/ ['m5_ 1 I EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day Inspection Type NC0037508 I11 12I 11/06/27 117 18IdI 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Comments •Facility was clean and neat in appearance at the time of the inspection. •The Division of Water Quality understands that the bidding portion of the planned upgrade is underway. Page # 2 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 06/27/2011 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ n n n Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ n n n Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? n n ■ n Is the facility as described in the permit? ■ n n n # Are there any special conditions for the permit? n n ■ n Is access to the plant site restricted fo the general public? ■ n n n Is the inspector granted access to all areas for inspection? ■ n n n Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ n n n Is all required information readily available, complete and current? ■ n n n Are all records maintained for 3 years (lab. reg. required 5 years)? ■ n n n Are analytical results consistent with data reported on DMRs? n n n ■ Is the chain -of -custody complete? n n n ■ Dates, times and location of sampling n Name of individual performing the sampling n Results of analysis and calibration n Dates of analysis n Name of person performing analyses 0 Transported COCs n Are DMRs complete: do they include all permit parameters? n n n ■ Has the facility submitted its annual compliance report to users and DWQ? ■ n n n (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? NODO Is the ORC visitation log available and current? ■ n n n Is the ORC certified at grade equal to or higher than the facility classification? ■ n n n Is the backup operator certified at one grade less or greater than the facility classification? ■ n n n Is a copy of the current NPDES permit available on site? ■ n n n Page # 3 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 06/27/2011 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? • n ❑ n Comment: Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? ■ n n Is flow meter calibrated annually? n n n n Is the flow meter operational? ■ n n n (If units are separated) Does the chart recorder match the flow meter? ❑ n • n Comment: Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? ■ n n n Is the wet well free of excessive grease? • n n n Are all pumps present? ■ ❑ n n Are all pumps operable? ■ n n n Are float controls operable? • n n n Is SCADA telemetry available and operational? n n ■ ❑ Is audible and visual alarm available and operational? n n n ■ Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical ■ Are the bars adequately screening debris? ■ n n n Is the screen free of excessive debris? ■ n n n Is disposal of screening in compliance? ■ n n n Is the unit in good. condition? ■ n n n Comment: Primary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ■ n n n Is the site free of excessive buildup of solids in center well of circular clarifier? ■ n n n Are weirs level? ■ n n n Page # 4 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 06/27/2011 Inspection Type: Compliance Evaluation Primary Clarifier Yes No NA NE Is the site free of weir blockage? ■ n n n Is the site free of evidence of short-circuiting? ■ n n n Is scum removal adequate? ■ n n n Is the site free of excessive floating sludge? ■ n n n Is the drive unit operational? ■ n n n Is the sludge blanket level acceptable? ■ n n n Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth) ■ n n n Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ■ n n n Is the site free of excessive buildup of solids in center well of circular clarifier? ■ ❑ ❑ ❑ Are weirs level? ■ ❑ n ❑ Is the site free of weir blockage? ■ ❑ n ❑ Is the site free of evidence of short-circuiting? ■ n n n Is scum removal adequate? ■ n n n Is the site free of excessive floating sludge? ■ n ❑ ❑ Is the drive unit operational? N n ❑ n Is the return rate acceptable (low turbulence)? ■ n n n Is the overflow clear of excessive solids/pin floc? ■ n n n Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) ■ nfl Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? ■ n ❑ . Are surface aerators and mixers operational? ❑ ❑ ■ n Are the diffusers operational? ■ n n n Is the foam the proper color for the treatment process? ■ n n n nn Does the foam cover less than 25% of the basin's surface? ■ n Page # 5 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 06/27/2011 Inspection Type: Compliance Evaluation Aeration Basins Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/I) Comment: Disinfection -Gas Are cylinders secured adequately? Are cylinders protected from direct sunlight? Is there adequate reserve supply of disinfectant? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Yes No NA NE ■ nnn ■ nnn Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn n n■n n n■n Yes No NA NE Gas ■ nnn ■ nnn ■ nnn n ❑ ■ ❑ n n■n Yes No NA NE ■ nnn ■ nnn ■ nnn n n■n Page # 6 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 06/27/2011 Inspection Type: Compliance Evaluation Standby Power Yes No NA NE Do the generator(s) have adequate capacity to operate the entire wastewater site? ■ n n n Is there an emergency agreement with a fuel vendor for extended run on back-up power? n n n • Is the generator fuel level monitored? ■ n n n Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional? n n ■ n Is sample collected above side streams? ■ n n n Is proper volume collected? ■ n n n Is the tubing clean? ■ n ❑ n # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ n n n Is sampling performed according to the permit? ■ ❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ■ ❑ n n' Is sample collected below all treatment units? ■ n n n Is proper volume collected? ■ n n n Is the tubing clean? ■ n n n # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ n n n Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ■ n n n Comment: Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? • n n n Comment: Page # 7