HomeMy WebLinkAboutNC0037508_WWTP Inspection_20120706A7,11 NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary July 26, 2012 George Yankay Moore County 1094 Adder Rd Aberdeen, NC 28315 SUBJECT: July 6, 2012 Compliance Evaluation Inspection Moore County Department of Public Utilities Moore County WPCF Permit No: NC0037508 Moore County Dear Mr. Yankay: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on July 6, 2012. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Senior Specialist, of the Fayetteville Regional Office. The cooperation of Mr. Rex Downs, Facility ORC, and Mrs. Jana Scherer, Laboratory Supervisor, was greatly appreciated. The facility was found to be in compliance with permit NC0037508. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Comments • Facility was as clean and neat as it could be due to ongoing construction activities. • No environmental impacts were observed from the bypasses that occurredearlier in the year. These bypasses were caused by mechanical issues and construction activities. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3327. Sincerely, Mark Brantley Environmental Senior Specialist Surface Water Protection Section Fayetteville Regional Office cc: Rex A Downs, ORC Central Files al ettevilIe Fi el ; (kmb r Location: 225 Green Street, Suite 714, Fayetteville, NC 28301 Phone (910) 433-3300\FAX: 910-486-0707\Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org NorthCarolina Naturally An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper United States Environmental Protection Agency EPA Washington, D.C. 20460 Water CompHanna Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8 31 98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 I N 1 2 1 51 31 NC0037508 1 11 121 12/07/06 117 Type Inspector Fac Type 181 C I 191 S I 20I 11 I I I I I I I I I I I I I I I `166 Remarks 211 I I I I I I I 'I I I I I I I I I I I I I I I I I I I I I I I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 169 701 31 71 1 N 1 721 N 1 731 1 1 74 75I 1 I I I I 1 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Moore County WPCF 1094 Addor Rd Aberdeen NC 28315 Entry Time/Date 10:00 AM 12/07/06 Permit Effective Date 10/12/01 Exit Time/Date 12:30 PM 12/07/06 Permit Expiration Date 14/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Rex A Downs/ORC/910-436-2836/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted George Yankay,1094 Adder Rd Aberdeen NC 28315//910-281-3146/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit ■ Flow Measurement • Operations & Maintenance Records/Reports Self -Monitoring Program $ Sludge Handling Disposal Facility Site Review • Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) • • Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mark Brantley ,% FRO WQ//910-433-3300 Ext.727/ 1 —(— L p.i.-ntJ}.,•t�. Signature of Management Q A Reviewer ''b — `7 Agency/Office/Phone and Fax Numbers �JDate ' 9�JBelinda S Henson,ei � FRO WQ//910-433-3300 Ext.726/ G 2 1 - 'v. EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day Inspection Type NC0037508 111 12I 12/07/06 1 17 18 1 CI 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Comments Facility was as clean and neat as it could be due to ongoing construction activities. No environmental impacts were observed from the bypasses that occurred earlier in the year. These bypasses were caused by mechanical issues and construction activities. Page # 2 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 07/06/2012 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with "acceptable housekeeping? ■ n n n Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ n n n Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? n n ■ n Is the facility as described in the permit? i n n n # Are there any special conditions for the permit? n n ■ n Is access to the plant site restricted to the general public? ■ n n n Is the inspector granted access to all areas for inspection? ■ n n n Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ n n n Is all required information readily available, complete and current? • n n n Are all records maintained for 3 years (lab. reg. required 5 years)? ■ n n n Are analytical results consistent with data reported on DMRs? ■ n n n Is the chain -of -custody complete? ■ n n n Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ n n n. Has the facility submitted its annual compliance report to users and DWQ? ■ n n n (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? ■ n ❑.-n Is the ORC visitation log available and current? ■ n n n Is the ORC certified at grade equal to or higher than the facility classification? ■ n n n Is the backup operator certified at one grade less or greater than the facility classification? ■ n n n Is a copy of the current NPDES permit available on site? ■ n n n Page # 3 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 07/06/2012 Inspection Type: Compliance Evaluation Record Keeping Facility has copy of previous year's Annual Report on file for review? Comment: Anaerobic Digester Type of operation: Is the capacity adequate? # Is gas stored on site? Is the digester(s) free of tilting covers? Is the gas burner operational? Is the digester heated? Is the temperature maintained constantly? Is tankage available for properly waste sludge? Comment: Drying Beds Is there adequate drying bed space? Is the sludge distribution on drying beds appropriate? Are the drying beds free of vegetation? # Is the site free of dry sludge remaining in beds? Is the site free of stockpiled sludge? Is the filtrate from sludge drying beds returned to the front of the plant? # Is the sludge disposed of through county landfill? # Is the sludge land applied? (Vacuum filters) Is polymer mixing adequate? Comment: Pump Station - Influent Is the pump wet well free of bypass lines or structures? Is the wet well free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Yes No NA NE ■ ❑❑❑ Yes No NA NE Floating cover ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑❑ Yes No NA NE ■ ❑❑❑ ■ ❑❑❑ ■ rn❑❑ ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑n ❑ ❑■❑ ❑ ❑■❑ ❑ ❑ ■ ❑ Yes No NA NE ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑❑ ❑ ❑®❑ Page # 4 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 07/06/2012 Inspection Type: Compliance Evaluation Pump Station - Influent Is audible and visual alarm available and operational? Comment: Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Grit Removal Type of grit removal a.Manual b.Mechanical Is the grit free of excessive organic matter? Is the grit free of excessive odor? # Is disposal of grit in compliance? Comment: Grit system is currently offline due to construction activities. Primary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? • Is the site free of excessive floating sludge? Is the drive unit operational? Is the sludge blanket level acceptable? Is the sludge blanket level acceptable? (Approximately 1/4 of the sidewall depth) Yes No NA NE n nn ■ Yes No NA NE n ■ ■ n n n ■ n n n ■ n n n ■ n n n Yes No NA NE n n n nn ■ n n,n■ n nn ■ Yes No NA NE ■ n n n ■ nnn ■ n n n ■ nnn, ■ nnn ■ nnn ■ nnn ■ nnn ■ n n n ■ n n n Page # 5 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 07/06/2012 Inspection Type: Compliance Evaluation Primary Clarifier Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately "1/4 of the sidewall depth) Comment: Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/I) Comment: Disinfection -Gas Are cylinders secured adequately? Are cylinders protected from direct sunlight? Is there adequate reserve supply of disinfectant? Is the level of chlorine residual acceptable? Yes No NA NE Yes No NA NE ■ ❑❑n ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ ❑n❑ ■ ❑❑❑ ■ nnn ■ nnn Yes No NA NE Ext. Air . Diffused ■ nnn nn■n ■ nnn ■ nnn ■ ❑❑❑ ■ nnn ■ nnn Yes No NA NE ■ nnn ■ ❑nn ■ nnn ■ nnn Page # 6 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 07/06/2012 Inspection Type: Compliance Evaluation Disinfection -Gas Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- If yes, then when was the RMP last updated? Comment: De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generators) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: Pumps-RAS-WAS Are pumps in place? Are pumps operational? Are there adequate spare parts and supplies on site? Yes No NA NE ■ nnn ■ nnn n nn■ n nn■ Yes No NA NE Gas ■ nnn ■ nnn ■ nnn n n■n n n■n Yes No NA NE ■ nnn ■ nnn ■ nnn n ❑ ❑ ■ ■ nnn ■ nnn ■ nnn Yes No NA NE ■ nnn ■ nnn ■ nnn Page # Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 07/06/2012 Inspection Type: Compliance Evaluation Pumps-RAS-WAS Yes No NA NE Comment: Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Yes No NA NE n n■n ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn Yes No . NA NE ■ nnn ■ nnn ■ n n n ■ nnn ■ nnn ■ nnn Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? ■ n n n Comment: Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Comment: Flow Measurement - Influent # Is flow meter used for reporting? ■ nnn ■ nnn n n■n ■ nnn n nn■ n nn■ Yes No NA NE ■ nnn Page.# 8 Permit: NC0037508 Owner - Facility: Moore County WPCF Inspection Date: 07/06/2012 Inspection Type: Compliance Evaluation Flow Measurement - Influent Yes No NA NE Is flow meter calibrated annually? ■ ❑ n n Is the flow meter operational? • ❑ n n (If units are separated) Does the chart recorder match the flow meter? n n • n Comment: Page # 9