Loading...
HomeMy WebLinkAbout20201685 Ver 1_Final INFO_20210609Strickland, Bev From: Tinklenberg, Chris <Chris.Tinklenberg@kimley-horn.com> Sent: Wednesday, June 9, 2021 11:04 AM To: Johnson, Alan Cc: Day, Blake Subject: FW: [External] RE: Savona DWR # 20-1685, SAW 2020-02248 Attachments: EX3 - Savona - Portman Development Exhibit with Topo_2020-0622.pdf; Savona Mill - Earthwork Exhibit_2021-0420.pdf CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Good morning Alan — per our conversation yesterday, please see responses to your comments below in red. Please review at your convenience and let me know if you need anything else. Thanks, Chris Chris Tinklenberg, PWS Kimley-Horn 1200 South Tryon Street, Suite 200, Charlotte, NC 28202 Direct: 704 409 1802 I Mobile: 910 538 9836 From: Day, Blake <Blake.Day@kimley-horn.com> Sent: Tuesday, May 11, 2021 7:37 PM To: Tinklenberg, Chris <Chris.Tinklenberg@kimley-horn.com> Subject: RE: [External] RE: Savona DWR # 20-1685, SAW 2020-02248 1) The stream is there, so that should go into the process of deliberating whether a project is viable or not with the area of concern. I find it hard to believe that one building affects the entire project. Profit depends on one building. a. They are apartments vs units for sell. To achieve the minimum return we need to be as close to 650 units as possible. Right now we are at 608-634. b. As part of the multi -family rezoning petition, we have proposed a reduction in the required 1:1 parking (spaces per unit) to 0.6:1 which intends to further minimize grading and disturbance within the floodplain and buffer of Stewart Creek. 2) It is approximately a 1.5 acre area, mostly covered in parking and also reduced by setbacks. The total site is approx. 28 acres. Hard to see how avoidance and minimization is being met or being considered. a. When you subtract the 100-ft buffer along Stewart Creek and the existing mill footprint, the developable area is only 16-acres. Flood plain and required roadway network improvements further reduces the developable area. 1 Significant grading improvements required for floodplain development to increase the developable area to 15.5 acres. The attached exhibit shows the developable areas in the sites existing condition. The 2.35 acres that are hatched is an approximate area we are able to unlock with the floodplain and stewart creek improvements. 3) The stream still handles runoff and discharge and rather than runoff be collected in a "sterile" pipe and move downstream, some remediation is possible a. Rerouting the stream is likely the best scenario from a stormwater quality perspective. We will be reducing the impervious mixing with this stream water in actuality. 4) The site is already level, I am not sure how this area is needed other than a place for fill dirt. a. Attached red are cut areas blue are fill areas. The building footprints are a little different as the architect has helped truth them up. 5) Low quality stream is better than no stream. Like low quality housing is better than no housing. Being a bit snarky, but the point is, it is still a natural feature and continuing to fill, and the reason is low quality/function is not a strong reason. Piping a stream still has an impact on the stream. a. The stream is currently piped under the existing paving field. There is a large sink hole in the center of the site that has exposed stormwater pipes and sanitary sewer pipes. (Per our discussion earlier, please find the attached photos of the "pit"). b. Re-routing the stream around the site in my opinion is better from a water quality standpoint and will help prevent accidental mixes of the brown stuff with the water. 6) Maybe the city will give a variance on building height? To allow more floors for retail and housing? a. We cannot go higher with any structures that would affect the visual integrity of the National Register -listed Mill, per NCSHPO. b. Any additional height also changes the construction type which dramatically increases costs associated with construction. 7) Are they collecting upgrading runoff (that the channel handles) and treating it? a. The plan is to permanently bypass the stormwater and treat impervious areas onsite for the additional stormwater flows. R. Blake Day, P.E. (NC, SC, TX) Kimley-Horn 1 200 South Tryon Street, Suite 200, Charlotte, NC 28202 Direct: (704) 319-5691 'Mobile: (704) 804-99571 Main: (704) 333-5131 Celebrating 13 years as one of FORTUNE's 100 Best Companies to Work For The electronic data files ("Files') furnished by Kimley-Horn and Associates, Inc. to the intended receiver of the Files ("Receiving Party') are provided only for the convenience of Receiving Party and only for its sole use.Receiving Party agrees that by opening the attachment(s) containing the files Receiving Party shall be bound by and subject to the terms of this notice.ln the case of any defects in the Files 2 or any discrepancies between the Files and the hardcopy of the Files prepared by Kimley-Horn, the hardcopy shall govern. Only printed copies of documents conveyed by Kimley-Horn may be relied upon. Any use of the information obtained or derived from these electronic files will be at the Receiving Party's sole risk. Because data stored in electronic media format can deteriorate or be modified inadvertently or otherwise without authorization of the data's creator, the Receiving Party agrees that it has 60 days to perform acceptance tests, after which it shall be deemed to have accepted the data transferred. Receiving Party accepts the Files on an "as is" basis with all faults. There are no express warranties made by Kimley-Horn with respect to the Files, and any implied warranties are excluded. From: Johnson, Alan <alan.johnson@ncdenr.gov> Sent: Tuesday, May 11, 2021 3:25 PM To: Tinklenberg, Chris <Chris.Tinklenberg@kimley-horn.com> Cc: Roden Reynolds, Bryan K CIV (USA) <Bryan.K.RodenReynolds@usace.army.mil>; Perez, Douglas J <doug.perez@ncdenr.gov> Subject: RE: [External] RE: Savona DWR # 20-1685, SAW 2020-02248 1) The stream is there, so that should go into the process of deliberating whether a project is viable or not with the area of concern. I find it hard to believe that one building affects the entire project. Profit depends on one building. 2) It is approximately a 1.5 acre area, mostly covered in parking and also reduced by setbacks. The total site is approx. 28 acres. Hard to see how avoidance and minimization is being met or being considered. The stream still handles runoff and discharge and rather than runoff be collected in a "sterile" pipe and move downstream, some remediation is possible 3) The site is already level, I am not sure how this area is needed other than a place for fill dirt 4) Low quality stream is better than no stream. Like low quality housing is better than no housing. Being a bit snarky, but the point is, it is still a natural feature and continuing to fill, and the reason is low quality/function is not a strong reason. Piping a stream still has an impact on the stream. 5) Maybe the city will give a variance on building height? To allow more floors for retail and housing? 6) Are they collecting upgrading runoff (that the channel handles) and treating it? Alan DWR DI -vision of Water Resources Alan D Johnson — Senior Environmental Specialist NC Dept. of Environment & Natural Resources (NCDENR) Division of Water Resources - Water Quality Regional Operations 610 East Center Ave., Suite 301, Mooresville, NC 28115 Phone: (704) 235-2200 Fax: (704) 663-6040 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. 3 From: Tinklenberg, Chris [mailto:Chris.Tinklenberg@kimley-horn.com] Sent: Tuesday, May 11, 2021 1:34 PM To: Johnson, Alan <alan.johnson@ncdenr.Rov> Cc: Roden Reynolds, Bryan K CIV (USA) <Bryan.K.RodenReynolds@usace.army.mil> Subject: [External] RE: Savona DWR # 20-1685, SAW 2020-02248 CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Hey Alan — in case you missed our correspondence with WRC, I've attached it for reference. Our response discusses parking including our rezoning request to minimize the required parking for the residential piece from 1:1 to 0.6:1. The thought is that parking can be shared by both the full-time residence as well as daily patrons of the Mill. This keeps us completely out of the 100-ft buffer of Stewart Creek and provides the necessary area for the riparian buffer enhancement and preservation. The parcel immediately to the east of your recommended building location is not part of this development, so the building would have to be fully within the triangular area, immediately adjacent to Stewart Creek and within the 100-ft buffer. This would also require additional buffer impacts for infrastructure, i.e. parking, on - site roadway connections, utilities which just wouldn't work given there's only 50-ft between Stewart Creek and the adjacent un-owned parcel (see snip below). Additionally, this is area is 5-ft below the base flood elevation. 4 Avoiding the impact by eliminating the building and associated parking would kill the site financially, both from an engineering/earthwork balance perspective as well as the loss of units for the developer to sell. Please keep in mind, that while the stream conveys perennial flow, most of the drainage originates from urban runoff and is discharged into the storm sewer system where it's daylighted for a short section above Turner Avenue and in this particular area in the northeastern corner of the site. The riparian area is almost exclusively made up of invasive species. From a quality/functional standpoint, stream function is extremely low. Let me know if you have any other questions or concerns. Thanks, Chris Chris Tinklenberg, PWS Kimley-Horn 1200 South Tryon Street, Suite 200, Charlotte, NC 28202 Direct: 704 409 1802 I Mobile: 910 538 9836 From: Johnson, Alan <alan.johnson@ncdenr.gov> Sent: Tuesday, May 11, 2021 8:49 AM To: Tinklenberg, Chris <Chris.Tinklenberg@kimley-horn.com> Cc: Roden Reynolds, Bryan K CIV (USA) <Bryan.K.RodenReynolds@usace.army.mil> Subject: Savona DWR # 20-1685, SAW 2020-02248 I am concerned that no consideration was given to avoidance and minimization. It appears that RES 0-1A could easily be moved to the other side of the project area (and associated parking) or omitted altogether to prevent the ongoing loss of a perennial channel. Much of the project appears to be made up of parking. Minor reduction is building sq footage could easily reduce the parking required in this area as well. Part of redevelopment, should include the redevelopment of natural areas. 5 DWR Division of Water Resources Alan D Johnson — Senior Environmental Specialist NC Dept. of Environment & Natural Resources (NCDENR) Division of Water Resources - Water Quality Regional Operations 610 East Center Ave., Suite 301, Mooresville, NC 28115 Phone: (704) 235-2200 Fax: (704) 663-6040 6 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. n LU LL V) LU J J LU N N cC i �r/r ri rrrr�i��/ i It a RELOCATION OF DRIVEWAY LIKELY REQUIRED. TO BE COORDINATED WITH COOT. EXISTING OFFSITE RUN-ON: APPROXIMATELY 34 0-53 0 ACRES RELOCATION OF EXISTING WATERLINE APPURTENANCES GA5 ALONG TURNER AVENUE. BLAZES BREWING " \ ♦ / I / �- ��A _ DEVELOPMENT TO CONNECT TO EXISTING WATER LINE TO BE PROPOSED GREEN WAY TO \^ \ i -'s - - / FACILITATE PEDESTRIAN TRAFFIC ss�ss Is��ss s I RELOCATED/ADJUSTED. ADDITIONAL ' a•` \\ '' WATERLINE APPURTENANCES ARE EXISTING FEMA COMUNITY A EXPECTED TO BE REQUIRED. NE TO BE - - / /'�I ENCROACHMENT LINE / E \ CLOMRILOMR MAY BE REQUIRED. EXISTING MILL 200,000 SF / EXISTING WATER LI S. TURNER AVENUE RELOCATED/ADJUSTED. ADDITIONAL \\\ I IIL \ 1 `1�\\ j WATERLINE APPURTENANCES ARE--- -- AA L= �� J I EXPECTED TO BE REQUIRED.ps - - EXISTING STORMWATER EXISTING STORMW "TER TO BE ADJUSTED OR REMOVED. TO BE ADJUSTED OR I REMOVED. ti / �Ay�66 I APPROXIMATE LOCATION _ r-� �/ /// / I �I / r J. OF EXISTING STREAM /%�i MODIFICATION OF CHAMBERLAIN AVENUE, REDUCE TO AND WETLAND i REMOVE EXISTING STORMWATER // / / �_- TWO 10' LANESAND PROVIDE STREETCAPE AND AND PROVIDE BYPASS STORMWATER PIPES ALONG TURNER AVENUE SIDEWALK. SIDEWALK TO BE LOCATED ON BOTH SIDES I V A VI �� 1 v 1 OF THE STREET WHERE FEASIBLE. I f /;:Vl STORMWATER PIPES TO - - = / / \/�� s I� T / / ) BE REMOVED/REROUTED�" / I I °„ ADJUSTMENT/RELOCATION OF �\ \ -/ �_ EXISTING UTILITIES LIKELY REQUIRED. ( °�, -� I / / \ t bw"_� �.� iI /� =�-1 ��. Il► � — � ( °- _ , UJI / � I � / � � �� � / I / l � l) 4 1 / ' EXISTING BUILDING Uj>v 1 '" III / / ♦ /♦ ' / ��1 �� TO REMAIN. � / ♦ I N '� \ WIDENING OF S. GARDNER AVENUE AS L..I/ SUGGESTED PER THE TIS PREPARED Cal BY DRG. REFER TO THE CONDITIONAL - l REZONING NOTES. \ fl,EXISTING SANITARY I I , / / / / ,'cs>>• `- / (-off �) \ / �I ' -� d�.��Il�I _ I l 11 h, Ilrlll PROPOSED STREAM IMPROVEMENTS, TO BE RIGHT OF WAY ACQUISITION MAY BE REQUIRED. TO BE �t I �SEWER TO BE I / // / / / y' ; /� o I / I -/ a") ' I 11 "IIl'/l' CONSTRUCTED BY MECKLENBURG COUNTY RELOCATED TO I ' ` \�� II I /lI' l _ ' / I /( / F` \ ` \ I - -•� I )1 ) I II 1 DESIGNED BY KIMLEY-HORN. COORDINATED WITH COOT DURING PERMITTING. - 1 PRIVATE STREET EXTENSION U �� �) S. GARDNER AVENUE - ----- _____'-_ I ► �� a ° v `1 ; ; �'41 ;!� / — ICI I I n -` v ' � - / � 111 \ e ( I / /}p4I I III PROPOSED GREENWAY, TO BE I' \ I' / / III' III CONSTRUCTED BY MECKLENBURG COUNTY DESIGNED BY KIMLEY-HORN. - � MODIFICATION OF GARDNER AVENUE, REDUCE 1 I1\ III \�AAy TO TWO 10' LANES AND PROVIDE STREETCAPE /�,--- \ I I 1 „� u o • \ 1 / /' (I '( 1( I I \ AND SIDEWALK. SIDEWALK TO BE LOCATED d 1 / ROTH SIIIFS CIF THE STRFFT WHFRF FFASIRI F '_� � � � I� / / 1 (11 I �1 PoI °j^��_ \- \\ //i I � 11/ �1 / / / P - I ,� ( 6 III//J//)II �, \ \\ _ / I I 1 _ II 'r/' I� ��\ • DEVELOPMENT LIMITS LIKELY POSSIBLE UP TO 1'v If I v / / THIS LINE WITH ADDITIONAL FLOOD ANALYSIS AND CLOMR/LOMR PERMITTING (12-24 MO) 0vv 1 I I I I I I PUBLIC RIGHT OF WAY 1 I I A I I I PROPERTY NOT A PART OF \; I \ I I I ( EXTENSION I - I I COMMUNITY 1 "Ill I THE PROPOSE DEVELOPMENT PLAN AT 11 \ I I 1 I \� a.l II�) THIS TIME. , I, i 1! I 'R i'' 1 '4d,. . -_� _ 1 ��1�1 %I I I I ` 1 / l 1 1 LI l l I II�II/l III 11, FN('.Rf)0CHI,dFNT I IMP I \ 1 I / � � I ( I I� / / / / / � MAY DEVELOP UP TO 1 I I � // / THIS LINE BY RIGHT. r/ ,, DEVELOPABLE AREA: ±g.34 ACRES EXISTING 36" WATER TRANSMISSION / / VI \ �� II _ A A \ "e i / III / ' V A\, //�///I I/ FEMA FLOOD ENCROACHMENT LINE. i ^' LINE. TO BE FIELD LOCATED. PROPOSED n DEVELOPMENT UP TO THIS LINE IS LIKELY MODIFICATION MAY BE REQUIRED. I I �/ III I / / ♦ \ \ 1 / / /� l/ 111 �/ - /i �/ /` //r I I 1 POSSIBLE WITH ADDITIONAL FLOOD ANALYSIS ��� AND FLOOD PLAIN DEVELOPMENT PERMITTING I a .ay v PRIVATE STREET EXTENSION. \ \ �, I / / / \\ !- ALIGNMENT MAY BE MANIPULATED FROM ''� ' ,'//' / `_ I / / I // \ - - r ✓ WHAT IS SHOWN. BUILD FRONTAGE ABUT THIS LINE. 1 EXISTING 24' SANITARY SEWER LINE, TO I I 1 Ip� i __ - / I / -- / ,\ � , ( INCREASE DEVELOPABLE LIMITS RELOCATION IS I I 1 LIKELY REQUIRED. TO BE DESIGED, PERMITTED 1 ,A,ND CONSTRI_ICTFD PFR (.HAR'-OTTF WATER REQUIREMENTS. .0_ .0 ((( A/I SANITARY 24" SEWER MAYBE RELOCATED TO 1'i l I i vI INCREASE DEVELOPABLE AREA. -_---- -`- I� �/ �_1 -_ II I �\� ------------- sa°a1 ,r •°a°v I o s � Ii ��.- , � � _ -� 7 °ate I RELOCATE EXISTING POWER POLES, TO BE COORDINATED WITH THE UTILITY SERVICES PROVIDER. (IN FUTURE 1 i V/�i�'� ' MP P°°a / / o / \ \ \ EXISTING WATER TRANSMISSION Lu PHASE) / \ LINE. TO BE FIELD LOCATED. ASSUME 20'/ "�� �� �� ' �i%°�' OF UNDISTURBED AREA ON BOTH SIDES. I;- II i x EXISTING STORMWATER TO BE DESIGNED FOR PROPOSED CHAMBERLAIN IMPROVEMENTS. 4 111�V PROPOSED PEDESTRIAN ACCESS TO BE PROVIDED AS REQUIRED PER THE _\\ I AV 1 11 II1111i /- CONDITIONS OF THE REZONING. — — I \vI % 111�I III \I � � � i� i/1�11 I 1 i 1 % - ����!�i%%/ ' � ✓l �'� iii / �i/'/ �/ PROPOSED PEDESTRIAN REFUGE TO BE PROVIDED AS REQUIRED CONDITIONS OF THE REZONING. 1 p_ _ oe or GRAPHIC SCALE IN FEET iii i� v i \ice/ ' i/ ✓ „�,��� � Know what's below. Call before you dig, Irl w Ld Q .m N O N L U Z °D N O c W U Z Lj Q U O O (n Of Q O N (n = U O Q U I Z O 0 O IM7 0O L� Z O 17 = N I W Z J�O O W Z Lj = U Z J 0 7 _j Z 0 O Y Of O N = � O N O Q v/ O O N r-Mr-LIIVIIIVHRT I I NOT FOR CONSTRUCTION U O LJJ O � Y O O N w N Q CN NN CD Z O Q W Q U co } °° o Z (n w 0 } m Z a of 0 m w = U W O 0. Q n `0001 W� J En Om J - W `v' / ' W W 0 Q Z J Q J U z J � O O I_L_I O All _j v) _ U O U SHEET NUMBER EX-3 -iis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Horn and Associates, Inc. Elevations Table Number Minimum Elevation Maximum Elevation Area Color 1 —20.00 —15.00 10942.78 2 —15.00 —10.00 23015.42 3 —10.00 —5.00 102509.78 4 —5.00 —0.50 247633.41 5 —0.50 0.50 136645.10 6 0.50 5.00 333359.66 7 5.00 10.00 125111.67 8 10.00 15.00 3823.70 9 15.00 20.00 2.17