HomeMy WebLinkAboutWQ0022876_Application (FTSE)_20030718T-TRACK APFUCATION forsGRAVITY SEVERS, PUMP STATIONS, AND FORCE MAINS PAGE 1 USE THE TAB KEY TO MOVE FROM FIELD TO FIELDI Application Number: (to be completed by DWQ) f,L)Q,Ooaa767. 1. Owner: Public Works Commission of the City of Fayetteville 1a. V— Full Legal Name (company, municipality, HOA, utility, etc.) 1 b. Joseph E. Glass, PE. Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for uthorize jig &ficials!) c. The legal entity who will own this system is: Individual 0 Federal a Municipality 0 State/County 0 Private Partn ld. P.O. Drawer 1089 Street Address hip 0 Corporation 0 Other (specify): le. Fayetteville City if. North Carolina State 1h. 910-223-4703 Telephone 11. 910-829-0203 Facsimile 1g. 28301 Zip Code ij. joe.glass@faypwc.com E-mail 2. Project (Facility) Information: 11. 2a. King's Grant Subdivision (Sections A, B and D-1) a., Brief Project Name (permit will refer to this name) 3. Contact Person: Pimna Chomchai, ICt 3a• The Rose Group, Inc. 2b. Cumberland County County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 910-323-3400 Phone Number 3c. pimna.chomchai@rosegrp.com E-mail 1. Project is is New El Modification (of an existing permit) If Modification, Permit No.: 2. Owner is Ei Public (skip to Item B(3)) El Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold facilities owned by a (must choose one) PAY TO THE ORDER OF THE ROSE GROUP.. ENGINEERS • PLANNERS • SURVEYORS RO.Box103 FayetteAle, NC 28302 THE SUM OF FOUR HUNDRED U.S. Dollars 00/100 ONLY NC DENR 225 Green Street Fayetteville, NC 28301-5043 C'efr c Hcv.‘ 64-3/4)6()ag-74° 44909 Bli&T Branch Banking and Trust Company 66-1121531 DATE 05/22/2003 THE ROSE GROUP. INC. AMOUNT $400.00 ,-,',-ACR 3 A 8. If the permitted flow is zero, indicate why: El interceptor Line - Flow will be permitted is subsequent permits that connect to this line El Flow has already been allocated in Permit No. EI Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 n State of North Carolina Department of Environment and Natural Resources Division of Water Quality FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure sewers systems are not to be included as part of this application package) INSTRUCTIONS: Indicate that you have included the following list of required application package items by checking the space provided next to each item. Failure to submit all required items will lead to your application being returned as incomplete or additional processing and review time. This form may be photocopied for use as an original. 1 I. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless you respond NO to Item B(12). tp II. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). ❑ III. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN) which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the CPCN or letter must match that provided in Item A(2a) of this application. ❑ IV. Operational Agreements — Submit one original and two copies of a properly executed operational agreement if the sewer extension will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be owned by a homeowners' association or developer (Item B(2b)). If the applicant is a homeowners' association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03. EVEN IF THE PROJECT WILL BE TURNED OVER TO A MUNICIPALITY, FORM DEV 02/03 IS REQUIRED. ❑ V. Flow Acceptance Letters — If the owner of the downstream sewers and/or WWTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and WWTF, if different. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/WWTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. [VI. Map — Submit an 8.5-inch by 11-inch copy of the portion of a 7.5-minute USGS Topographic Map along with this form. The map should identify the entire project area location as well as the closest downslope surface waters as clearly as possible. Each map portion must be labeled with the map name and number, the identified location, and be of clear and reproducible quality. For instance, if the project involves 4 miles of interceptor sewer that traverses over or near several different waterbodies (or counties, basins, etc.), the map should have location ID's for each different waterbody (where the sewer line is within 100 feet of such waterbody - see Instruction VII). `�,VII. Watershed Classifications — Section C \\ • If any portion of the project is within 100 feet of any down slope surface water, Section C must be completed for the pertinent sections. • If the entire project area is a minimum of 100 feet away from any down slope surface waters BUT there is a pump station involved where a history of power outage is to be used to provide adequate design storage instead of dual feed or permanent or portable generator, Section C must be completed to demonstrate that the closest down slope surface water is Class C (see 15A NCAC 2H .0219(h)(3)(D)). • Use the guidance document entitled, "Determining Watershed Classifications for Form FTA 02/03 (Fast -Track Sewer Systems)" available from http://h2o.enr.state.nc.us/ndpu or by contacting the appropriate regional office. INSTRUCTIONS FOR FORM FTA 02/03 ❑ VIII. Environmental Assessments — If this project is subject to an Environmental Assessment (EA) ]15A NCAC 01C .0500], this application can not be used. Send the project application on Form PSFMGSA 10/99 to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Applications can not be processed until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been issued. A copy is to be submitted with that permit application. If" IX. Certifications — Section D The application must be certified by both the applicant and a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(1b). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC 2H .0200, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. Certification by a PE who is unfamiliar with these documents is subject to NC Board referral. THE COMPLETED FTA 02/03 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $400 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 59 Woodfin Place Asheville, North Carolina 28801 (828) 251-6208 (828) 251-6152 Fax Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville, North Carolina 28301 (910) 486-1541 (910) 486-0707 Fax Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Mooresville Regional Office 919 N Main Street Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 571-4700 (919) 571-4718 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Washington Regional Office 943 Washington Square Mall Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 395-3900 (901) 350-2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Winston-Salem Regional Office 585 Waughtown Street Winston-Salem, North Carolina 27107 (336) 771-4600 (336) 771-4631 Fax Alamance, Allegheny, Ashe, Caswell, Davidson, David, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin For more information, visit our web site at: http://h2o.enr.state.nc.uslndpul INSTRUCTIONS FOR FORM FTA 02/03 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 1 USE THE TAB KEY TO MOVE FROM FIELD TO FIELM! . Owner: Public Works Commission of the City of Fayetteville a. Application Number: �: (to be completed by DWQ) 6076 Full Legal Name (company, municipality, HOA, utility, etc.) . '' 1b. Joseph E. Glass, PE. i I Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for utho�-izedi nilg Officials!) c. The legal entity who will own this system is: 0 Individual 0 Federal El Municipality 0 State/County ❑ Private Partn 1d. P.O. Drawer 1089 Street Address hip 0 Corporation 0 Other (specify): le. Fayetteville City IH a if. North Carolina State lh. 910-223-4703 Telephone 1 i. 910-829-0203 Facsimile 1 g. 28301 Zip Code 1 j. joe.glass@faypwc.com E-mail 2. Project (Facility) Information: 2a. King's Grant Subdivision (Sections A, B and D-1) 2b. Cumberland County Brief Project Name (permit will refer to this name) 3. Contact Person: Pimna Chomchai, 3a. The Rose Group, Inc. County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 910-323-3400 Phone Number 3c. pimna.chomchai@rosegrp.com E-mail ''1. Project is la New ❑ Modification (of an existing permit) If Modification, Permit No.: 2. Owner is Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: ❑ Retaining Ownership (i.e. store, church, single office, etc.) ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 2b. If sold facilities owned by a (must choose one) ❑ Public Utility (Instruction III) ❑ Homeowner Assoc./Developer (instruction IV) Public Works Commission of The City of Fayetteville Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Cross Creek Water Treatment Plant 4b.NC 0023957 Name of WWTF WWTF Permit No. 0 Z 5a. Same as #3 15b. Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer £. The origin of this wastewater is (check all that apply): 2 W m • • (Residential Subdivision ❑ Apartments/Condominiums ❑ Mobile Home Park ❑ School ❑ Restaurant ❑ Office ❑ Car Wash ❑ Institution ❑ Hospital ❑ Church ❑ Nursing Home ❑ Other (specify): 100 % Domestic/Commercial Industrial % Other (specify): 7. Volume of wastewater to be permitted in this project: 23,76° gallons per day 8. If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 2 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3). There will be 66 residential lots in the subdivision; 360 gal/day/lot x 66 residential lots = 23,760 gal/day 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main 8-inch 4,618 Gravity 15- inch 126 Gravity 2 z 0 Z ENTER TOTAL LINE LENGTH IN MILES 0.9 mile 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (as shown on plans) Design Flow (MGD) Operational Point GPM @ TDH Power Reliability Option (dual line feed, permanent generator w/ATS, portable generator w/autodialer, wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? E Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? El Yes ❑ No ❑ N/A Sedimentation and Erosion Control Plan? ❑ Yes g No ❑ N/A Stormwater? ❑ Yes ❑ No a N/A FTA 02/03 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: ❑ A Watershed Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND A Watershed Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map Name of Waterbody McPherson Creek County Cumberland River Basin Cape Fear Waterbody Stream Waterbody Index Classification 18-24-3-(1) WS-1V 0 Submit the 8.5" x 11" topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: i attest that this application for King's Grant Subdivision (Sections A, B and D-1) has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being retumed as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violati Signinfficia Signature Date Professional Engineer's Certification: King's Grant Subdivision (Sections A, B and D-1) 1 attest that this application for has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. a. Pimna Chomchai, PE. Professional Engineer Name 2b. The Rose Group, Inc. Engineering Firm 2c. P.O. Box 103 Gillespie Street Address 2d. Fayetteville 2e. NC City 2g. 910-323-3400 2h. 910-323-1028 Telephone Facsimile 2f. 28302 State Zip 2i. pimna.chomchai@rosegrp.com E-mail '�H CARD O�.�FESS/0••.;"i :Q SEAL'e: 28459 yG.rP '9 CHOM w i/ g/o) Seal, Signature & Date FTA 02/03 Name of Stream Description Curr. Class Date Prop. Class Basin Stream Index # CAPE FEAR RIVER Carvers Creek (Cypress Lake) West Prong Carvers Creek North Prong Carvers Creek (Currin Lake) /McPherson Creek V (College Lake) McPherson Creek (Wooded Lake) Greens Creek (Holmes Pond) Evans Lake CAPE FEAR RIVER CAPE FEAR RIVER Cross Creek (Big Cross Creek) (Texas Pond, Smith Lake, Rose Lake) Unnamed Tributary near Rosehill Road (Country Club Lake) Unnamed Tributary near Rosehill Road From a point 8.2 miles WS-IV upstream of Cravers Creek to a point 0.5 mile upstream of City of Fayetteville water supply intake From source to Cape Fear River From source to Carvers Creek From source to Carvers Creek From source to dam at College Lake From dam at College Lake to Carvers Creek From source to McPherson Creek Entire lake and connecting stream to Cape Fear River WS-IV,B WS-IV WS-IV WS-IV WS-IV,B WS-IV,B WS-IV 08/03/92 08/03/92 08/03/92 08/03/92 08/03/92 08/03/92 08/03/92 08/03/92 From a point 0.5 mile WS-IV;CA 08/03/92 upstream of City of Fayetteville water supply intake to City of Fayetteville water supply intake From City of Fayetteville water supply intake to mouth of Hammond Creek C From source to a point WS-IV 0.5 mile upstream of water supply intake at Murchison Road in Fayetteville 04/01/59 08/03/92 From source to dam at WS-IV,B 08/03/92 Country Club Lake From dam at Country Club Lake to Cross Creek WS-IV 08/03/92 Cape Fear 18-(23.5) Cape Fear 18-24 Cape Fear 18-24-1 Cape Fear 18-24-2 Cape Fear Cape Fear Cape Fear Cape Fear 18-24-3-(1) 18-24-3-(2) 18-24-3-3 18-25 Cape Fear 18-(25.5) Cape Fear 18-(26) Cape Fear 18-27-(1) Cape Fear 18-27-2-(1) Cape Fear 18-27-2-(2) Page 2 of 6 REQUIREMENTS & SPECIFICATIONS FOR SEWER MAIN EXTENSIONS FOR THE PUBLIC WORKS COMMISSION FAYETTEVILLE, NORTH CAROLINA CUMBERLAND COUNTY PROJECT: King's Grant Phase I DATE SUBMITTED July 15, 2003