HomeMy WebLinkAboutNCG030134_DMR_20210324Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted: 03/24/2021 CERTIFICATE OF COVERAGE NO. NCG030134 SAMPLE COLLECTION YEAR SAMPLE PERIOD —Jan-June July -Dec FACILITY NAME: Thermo Fisher Scientific (Asheville) LLC Or X Monthly: February COUNTY: Buncombe RECF P, SCHARGING TO CLASS C�RI ❑ HQW "X [Trout ❑ PNA PERSON COLLECTING SAMPLES: Jeremy Putnam, EHS ❑Zero -flow ❑Hater Supply ❑SA LABORATORY: Pace Analytical Lab Cert. # APR 0 5 2021 [7]Other Comments on sample collection or analysis: CENTRAL FILE, CVVR SECTION PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 - Part A: Stormwater Benchmarks and Monitoring Results ❑No discharge this period?' Outfall No. Date Sample P Collected 1 (mo/dd/yr) 24-hour rainfall amount, Inches Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks _ - 100 mg/L or 50 mg/O 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 Outfall1 02/26/2021 0.3 19.0 6.75 0.0057 <0.005 0.150 <5 N/A Outfail2 02/26/2021 0.3 40.8 6.6 0.0411 <0.005 0.241 <5 N/A Outfall3 02/26/2021 0.3 117.0 6.45 0.0556 0.0117 0.254 <5 N/A Outfall4 02/26/2021 10.3 111.9 6.4 <0.005 <0.005 0.189 <5 N/A Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469,31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Name (Print name) Tie rinttitle) Signature Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX me/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. nNo discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches" New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/ Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - - 15 mg/L 100 mg/L or 50 mg/V Parameter Code - 46529 NCOIL 00552 C0530 Footnotes from Part A also apply to Part B Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 2 of 3 FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES X NO IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES NO REGIONAL OFFICE CONTACT NAME: Ms. Laura Herbert (Asheville Regional Office) Mail an original copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am a#.arre that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee Date Permit Date: 11/1/2018-05/31/2021 11/1/2018 SWU-245, last revised Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted: 03/24/2021 CERTIFICATE OF COVERAGE NO. NCG030134 FACILITY NAME: Thermo Fisher Scientific (Asheville) LLC COUNTY: Buncombe PERSON COLLECTING SAMPLES: Jeremy Putnam, EHS LABORATORY: Pace Analytical Lab Cert. # Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR: 2020 SAMPLE PERIOD _Jan -June July -Dec Or X Monthly: January {g4SCHA,RGING TO CLASS n ORW n HQW nTrout n PNA E1 v 5 ❑❑ Zero -flow NaterSupply ]SA APR 0 5 2021 []Other GENT'I11�1­ PILES DWR u`CTION PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 - nNo discharge this period ?2 Outfall No. Date Sample Collected) (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons y Total Toxic Organics' Benchmarks - - 100 mg/L or 50 mg/L° 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 Outfall 1 Outfall 2 Outfall 3 Outfall 4 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution P ion Plan." t Name (Print name) Y\ itle (Print title) Signature Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX me/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. FINo discharge this period?Z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/ Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - - 15 mg/L 100 mg/L or 50 mg/O Parameter Code - 46529 NCOIL 00552 C0530 Footnotes from Part A also apply to Part B Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 2of3 FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES X NO IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES NO REGIONAL OFFICE CONTACT NAME: Ms. Laura Herbert (Asheville Regional Office) Mail an original cwv of this OW including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I a7� ware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." o4 a--��, Signature of Permittee Permit Date: 11/1/2018-05/31/2021 11/1/2018 Date SWU-245, last revised /�;a'ceAnalXical' www.pacelabs.com March 09, 2021 Mr. Jeremy Putnam Thermo Electron Corp. 275 Aiken Road Asheville, NC 28804 RE: Project: Feb.2021 SW 2126 Pace Project No.: 92524538 Dear Mr. Putnam: Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 Enclosed are the analytical results for sample(s) received by the laboratory on February 26, 2021. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNUNELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services -Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Chris Derouen christopher.derouen@pacelabs.com (828)254-7176 Project Manager Enclosures AEV.- REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. (828)254-7176 Page 1 of 13 01 Pace Analytical Services, LLC aAnaly�ical 2225 Riverside Dr. ce Ashevtlle, NC 28804 i wwr.pacelatrscoro (828)254-7176 CERTIFICATIONS Project: Feb.2021 SW 2/26 Pace Project No.: 92524538 Pace Analytical Services Charlotte 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Flodda/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 North Carolina Wastewater Certification M 40 South Carolina Certification M 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in fill, without the written consent of Pace Analytical Services, LLC. Page 2 of 13 ace I Analytical e wWW.PacclabLeam i SAMPLE ANALYTE COUNT Project: Feb.2021 SW 2126 Pace Project No.: 92524538 Pace Analytical Services, LLC 2225 Riverside Or. Asheville, NC 28804 (828)254-7176 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92524538001 1 EPA 1664E CJM 1 PASI-C EPA 1664B CJM 1 PASI-C EPA 200.7 Rev 4.4 1994 RDT 3 PASI-A SM 2540D-2011 RED 1 PASI-A 92524538002 2 EPA 1664E CJM 1 PASI-C EPA 1664B CJM 1 PASI-C EPA 200.7 Rev 4.4 1994 RDT 3 PASI-A SM 2540D-2011 RED 1 PASI-A 92524538003 3 EPA 1664B CJM 1 PASI-C EPA 1664E CJM 1 PASI-C EPA 200.7 Rev 4.4 1994 RDT 3 PASI-A SM 2640D-2011 RED 1 PASI-A 92524538004 4 EPA 1664B CJM 1 PASI-C EPA 1664E CJM 1 PASI-C EPA 200.7 Rev 4.4 1994 RDT 3 PASI-A SM 2540D-2011 RED 1 PASI-A PASI-A= Pace Analytical Services -Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 13 !;5'ceAna1Aca1* xwa.Pacelab cem ANALYTICAL RESULTS Project: Feb.2021 SW 2126 Pace Project No.: 92524538 Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Sample: 1 Lab ID: 92524538001 Collected: 02/26/21 12:45 Received: 02/26/21 13:45 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664E Pace Analytical Services - Charlotte Oil and Grease ND mg/L 5.0 1 03/09/21 10:17 1664 SGT-HEM, TPH Analytical Method: EPA 1664E Pace Analytical Services - Charlotte Total Petroleum Hydrocarbons ND mg/L 5.0 1 03/09/21 10:17 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Pace Analytical Services - Asheville Copper 5.7 ug/L 5.0 1 03/07/21 17:20 03/08/21 12:25 7440-50-8 Lead ND ug/L 5.0 1 03107/2117:20 03/08/2112:25 7439-92-1 Zinc 150 ug/L 10.0 1 03/07/21 17:20 03/08/21 12:25 7440-66-6 2540D Total Suspended Solids Analytical Method: SM 254OD-2011 Pace Analytical Services -Asheville Total Suspended Solids 19.0 mg/L 6.1 1 03/03/21 22:33 Sample: 2 Parameters HEM, Oil and Grease Oil and Grease 1664 SGT-HEM, TPH Total Petroleum Hydrocarbons 200.7 MET ICP Copper Lead Zinc 2540D Total Suspended Solids Total Suspended Solids Date: 03109/2021 04:16 PM Lab 1D: 92524538002 Collected: 02/26/21 13:00 Received: 02/26/21 13:45 Matrix: Water Results Units Report Limit DF Prepared Analyzed GAS No. Qual Analytical Method: EPA 1664E Pace Analytical Services - Charlotte ND mg/L 5.0 1 03/0912110:17 Analytical Method: EPA 1664E Pace Analytical Services - Charlotte ND mg/L 5.0 1 03/09/21 10:17 Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Pace Analytical Services - Asheville 41.1 ug/L 5.0 1 03/07/21 17:20 03/08/21 12:35 7440-50-8 ND ug/L 5.0 1 03/07/21 17:20 03/08/21 12:35 7439-92-1 241 ug/L 10.0 1 03/07/21 17:20 03/08/21 12:35 7440-66-6 Analytical Method: SM 254OD-2011 Pace Analytical Services - Asheville 40.8 mg/L 6.2 1 03/03/2122:34 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, L.L.C. Page 4 of 13 Pace Analytical Services, LLC /���alcemalytical Nevi eNCRiverside 04 Asheville, NC 28804 wcrw.pacalain=M (828)254-7176 ANALYTICAL RESULTS Project Feb.2021 SW 2/26 Pace Project No.: 92524538 Sample: 3 Lab ID: 92524538003 Collected: 02126/21 13:15 Received: 02/26/21 13:45 Matrix: Water Parameters Results Units Report Limit OF Prepared Analyzed GAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Oil and Grease NO mgiL 5.0 1 03/09/21 10:17 1664 SGT-HEM, TPH Analytical Method: EPA 1664E Pace Analytical Services - Charlotte Total Petroleum Hydrocarbons NO mg/L 5.0 1 03/09/21 10:17 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Pace Analytical Services - Asheville Copper 55.6 ug/L 5.0 1 03/07/21 17:20 03/08/21 12:38 7440-50-8 Lead 11.7 ug/L 5.0 1 03/07/21 17:20 03/08/21 12:38 7439-92-1 Zinc 254 ug/L 10.0 1 03/07/21 17:20 03/08/21 12:38 7440-66-6 2540D Total Suspended Solids Analytical Method: SM 254OD-2011 Pace Analytical Services - Asheville Total Suspended Solids 117 mg/L 25.0 1 03/03/21 22:34 Sample: 4 Parameters HEM, Oil and Grease Oil and Grease 1664 SGT-HEM, TPH Total Petroleum Hydrocarbons 200.7 MET ICP Lab lD: 92524538004 Collected: 02/26/21 13:30 Received: 02/26/21 13:45 Matrix: Water Results Units Report Limit OF Prepared Analyzed CAS No. Qua[ Analytical Method: EPA 1664B Pace Analytical Services - Charlotte NO mg/L 5.0 1 03/09/2110:17 Analytical Method: EPA 1664B Pace Analytical Services - Charlotte NO mg/L 5.0 1 03/09M 10:17 Analytical Method. EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Pace Analytical Services - Asheville Copper NO ug/L 5.0 1 03/07/21 17:20 03/08/2112:42 7440-50-8 Lead NO ug/L 5.0 1 03/07/21 17:20 03/08/21 12:42 7439-92-1 Zinc 189 ug/L 10.0 1 03/07/21 17:20 03/08/21 12:42 7440-66-6 2540D Total Suspended Solids Analytical Method: SM 254OD-2011 Pace Analytical Services - Asheville Total Suspended Solids 11.9 mg/L 3.5 1 03/03/21 22:35 Date: 03/09/2021 04:16 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 5 of 13 aceAnalytical 1WW.Pac*ItbSX0M QUALITY CONTROL DATA Project: Feb.2021 SW 2/26 Pace Project No.: 92524538 QC Batch: 604994 Analysis Method: EPA 1664B QC Batch Method: EPA 1664E Analysis Description: 1664 HEM, Oil and Grease Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92524538001, 92524538002, 92524538003, 92524538004 METHOD BLANK: 3187522 Matrix: Water Associated Lab Samples: 92524538001, 92524538002, 92524538003, 92524538004 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Oil and Grease mg/L ND 5.0 03/09/21 10:17 Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 {828}254-7176 LABORATORY CONTROL SAMPLE: 3187523 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Oil and Grease mg/L 40 32.0 80 78-114 MATRIX SPIKE SAMPLE: 3187524 92525094001 Spike MS MS % Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Oil and Grease mg/L ND 40 34.1 82 78-114 Results presented on this page are in the units Indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/0912021 04:16 PM without the written consent of Pace Analytical Services, I.I.C. Page 6 of 13 aOAnalytical e wiew.pacelabs com QUALITY CONTROL DATA Project: Feb.2021 SW 2/26 Pace Project No.: 92524538 QC Batch: 604999 Analysis Method: EPA 1664E QC Batch Method: EPA 1664B Analysis Description: 1664 SGT HEM, TPH Laboratory: Pace Analytical Services - Chedotte Associated Lab Samples: 92524538001, 92524538002, 92524538003, 92524538004 METHOD BLANK: 3187550 Matrix: Water Associated Lab Samples: 92524538001, 92524538002, 92524538003, 92524538004 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Petroleum Hydrocarbons mg/L ND 5.0 03/09/21 10:17 Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 LABORATORY CONTROL SAMPLE: 3187551 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Petroleum Hydrocarbons mg/L 20 12.9 64 64-132 MATRIX SPIKE SAMPLE: 3187552 92525094001 Spike MS MS % Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Total Petroleum Hydrocarbons mg/L ND 20 13.8 63 64-132 M1 Results presented on this page are In the units Indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03109/2021 04:16 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 13 1__5a'CeAnalytical'� yr pecelabs cam i QUALITY CONTROL DATA Project: Feb.2021 SW 2126 Pace Project No.: 92524538 QC Batch: 604799 Analysis Method: EPA 200.7 Rev 4.4 1994 QC Batch Method: EPA 200.7 Rev 4.4 1994 Analysis Description: 200.7 MET Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92524538001, 92524538002, 92524538003, 92524538004 METHOD BLANK: 3186433 Matrix: Water Associated Lab Samples: 92524538001, 92524538002, 92524538003, 92524538004 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Copper ug/L NO 5.0 03/08/2117:57 Lead ug/L NO 5.0 03/08/2117:57 Zinc ug/L NO 10.0 03/08/2117:57 Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 LABORATORY CONTROL SAMPLE: 3186434 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Copper ug/L 500 526 105 85-115 Lead ug/L 500 502 100 85-115 Zinc ug/L 500 497 99 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3186435 3186436 MS MSD 92524538001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Copper ug/L 5.7 500 500 411 422 81 83 70-130 3 Lead ug/L ND 500 500 401 412 80 82 70-130 3 Zinc ug/L 150 500 500 548 566 80 83 70-130 3 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3186437 3186438 MS MSD 92525328001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Copper ug/L 117 500 500 532 617 83 100 70-130 15 Lead ug/L ND 500 500 393 449 79 90 70-130 13 Zinc ug/L ND 500 500 450 527 81 97 70-130 16 Results presented on this page are In the emits Indicated by the "Units" column except where an alternate unit is presented to the right of the result REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/09/2021 04:16 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 13 5XAnalytical® www.pacelebeom i QUALITY CONTROL DATA Project: Feb.2021 SW 2/26 Pace Project No.: 92524538 Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QC Batch: 604031 Analysis Method: SM 254OD-2011 QC Batch Method: SM 254OD-2011 Analysis Description: 2540D Total Suspended Solids Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92524538001, 92524538002, 92524538003, 92524538004 METHOD BLANK: 3182324 Matrix: Water Associated Lab Samples: 92524538001, 92524538002, 92524538003, 92524538004 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Suspended Solids mg/L ND 2.5 03/03/21 22:27 LABORATORY CONTROL SAMPLE: 3182325 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mg/L 250 248 99 90-110 SAMPLE DUPLICATE: 3182588 92524582006 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 1420 1080 27 D6 SAMPLE DUPLICATE: 3182589 92524582007 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 6200 6750 8 Results presented on this pogo are in the units Indicated by the "Units" column except where an alternate unit is presented to the right of the result REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/09/2021 04:16 PM without the written consent of Pace Analytical Services, LLC. Page 9 of 13 aceAnalAcal a / wuw.pacelalrs cam QUALIFIERS Project: Feb,2021 SW 2/26 Pace Project No.: 92524538 DEFINITIONS OF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (826)254-7176 PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitdle by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS D6 The precision between the sample and sample duplicate exceeded laboratory control limits. M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/09/2021 04:16 PM without the written consent of Pace Analytical Services, L-C. Page 10 of 13 �;alceAnalytical www.paealehscom QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Project Feb.2021 SW 2126 Pace Project No.: 92524538 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92524538001 1 EPA 1664B 604994 92524538002 2 EPA1664B 604994 92524538003 3 EPA1664B 604994 92524538004 4 EPA1664B 604994 92524538001 1 EPA 1664B 604999 92524538002 2 EPA 1664B 604999 92524538003 3 EPA16648 604999 92524538004 4 EPA 1664E 604999 92524538001 1 EPA 200.7 Rev 4.4 1994 604799 EPA 200.7 Rev 4.4 1994 604802 92524538002 2 EPA 200.7 Rev 4.4 1994 604799 EPA 200.7 Rev 4.4 1994 604802 92524538003 3 EPA 200.7 Rev 4.4 1994 604799 EPA 200.7 Rev 4.4 1994 604802 92524538004 4 EPA 200.7 Rev 4.4 1994 604799 EPA 200.7 Rev 4.4 1994 604802 92524538001 1 SM 254OD-2011 604031 92524538002 2 SM 254OD-2011 604031 92524538003 3 SM 254OD-2011 6D4031 92524538004 4 SM 254OD-2011 6D4031 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/0912021 04:16 PM without the written consent of Pace Analytical Services, I.I.C. Page 11 of 13 X— so 0 — F T K A— 2. 'D m r x Cal a 0 CL p 0 CIO w I CV fJ cc ro M rr e44 Z 0 z o m 0 0 CL Wo 6 r ffin w tu EL E; cr c 71 LF at cu C4 0 - * r Am, (D S", m z In tv 0, Q M. 211 th C'L M M c CL z M, CL F.* 17 a, ir oz RL fb I\A -4- —4 4-L- FAr S 0 -74 rt C. ot-1, I L\I -TOW �MSMAdeA �01?A-f ul z '17 2 0 Cr La ry 51 vDOc- -0 tr w Cu IL 1 tr c CL 0 0 0 = m r , = * I IxI 1,• " 11 11 1,- ", " R M Q - UM M P. 4 Z P �F 91 — ;q rO c Ij -10 0 r, H O. Q c m a 0 En n m z 0 R 0 to to Z z: m Ir cr 7r z cz, M Z Z M z Page 12 of 1i - 'aCBARal)601 �- Document Name: Sample Condition Upon Receipt(SCUR) Document Revised: October 28, 2020 Page 2 of 2 Document No.: F-CAR-CS-033-Rev.07 g Authority: =Paceinas Quality Office *Check mark top half of box if pH and/or dechlorination is Project f WUP ; UZ5Z4538 verified and within the acceptance range for preservation PM: CDl Due Date: 03/12/21 samples. Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC, LLHg CLIENT: 93-Thermo "Bottom half of box is to list number of bottles Z a a a a y o K a z i Zq@ c o c N rvo Z CL v =`v v d v v T? °°' z` O= v E Z •_. > n c uO `c_ O M r: c n a O O ¢ V n c O ry 2 ? 7 7 C = 2 2 a _ = r ^' ,'Z„ x T rs^v c �L = •C ✓ L G L C Z J 2 Y I " a .n y E o q ¢ G q rJ r✓ c; °' q •G E 2 4 G N a E E E d N O Q O> C. r Vl C C C E J fie` 9 ,n J E E E E E E E E v u c E m E E E E `= a i =_ c E N N N i r, .Y In Q O O ✓ ti IN`' 2 N cL Q .7 a 7 a. 7 a 7 a a a. a -y t7 .4 m t� .- m t9 in LD ih O M t9 C- t9 01 r� i > N N v, m d > G aEi m m co m D m a. w m d d d d d d C } } 41i— T, 5 ( � • E 6 i 7 k 8 9 k I 10 1 11 1 12 pH Adjustment Log for Preserved Samples Sample t0 Type of Preservative pH upon receipt Date preservation adjusted Time preservation adjusted Amount of Preservative added Lot # r---...:u L. ---....i.,.m...-h r— inn nFWNR rprtification Office 0 e. Note: ,vuenever mere is a ciscrepancy attectmg rvonn Ld-owup lump„a„�- �o.,.,-ll-, _ v_,., Out of hold, incorrect preservative, out of temp, incorrect containers. Page 13 of 13 Thermo Rsher S C I E N T I F I C March 24, 2021 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: Stormwater Analytical Monitoring Results for Thermo Fisher Scientific, LLC I have attached the analytical monitoring results from stormwater sampling that was collected on February 26, 2021 at Thermo Fisher Scientific, LLC's four outfalls. Per our General Storm Water Permit No. NCG03000 requirements of monthly monitoring for applicable parameters during a storm event, I have sampled each outfall for copper, zinc, pH, lead, TSS, and Non -Polar Oil/Grease/TPH. Results show that TSS at one outfall, copper at two outfalls, and zinc at all four outfalls were above the benchmark values, as noted in Table 3 of the general storm water permit. All other results were below the benchmark values. We have implemented a Tier Three response for the site and Thermo Fisher Scientific, LLC has notified the Asheville Regional Office. Thermo Fisher Scientific, LLC is currently working with an environmental consultant to help achieve compliance with the benchmark values set forth in the facility's storm water permit. I have attached the completed Monitoring Report containing the monitoring results from the four outfalls. If you have any questions, please feel free to contact me at 828-658-2845. Jeremy Putnam Sr. EHS Manager Attachments: 1