Loading...
HomeMy WebLinkAboutNCG060023_DMR_20210607(T-0) Tyson June 7, 2021 Department of Environment and Natural Resources Division of Water Quality, Central Files 1617 Mail Service Center Raleigh, NC 27699 -1617 RE: Tier Two Monthly Discharge Report Tyson Farms, Inc. Monroe, Union County, North Carolina General Permit Number; NCG06000 p'�'av:A3 Dear Sir/Madam: juil 14 Z021 CENTRAL FILES DWR SECTION Per the requirements of General Permit No. NCG060000, enclosed are two copies of the monthly discharge report for outfall #007. Outfall #7, which is the discharge from the on property stormwater pit, was above the COD and TSS benchmarks for two consecutive sampling periods placing this location in Tier Two. Monthly sampling for COD and TSS is being conducted at outfall #7. If you have any questions, please contact Katelyn Stroud at (704) 296-4959 or via email at Katelyn.stroud @tyson.com. Sincerely, onathan dwards omplex anager Tyson Farms, Inc. Monroe, NC Complex 233 S. Secrest Ave., Monroe NC 28112 (704) 296-49oo Fax: (704) 296-4904 A-w-w.tysonfoods.corn STORMWATER DISCHARGE MONITORING REPORT for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG060000 Date submitted 6/7/20 CERTIFICATE OF COVERAGE NO. NCG06 0 0 2 3 FACILITY NAME Tyson Farms, Inc. COUNTY Union PERSON COLLECTING SAMPLES Katelyn Stroud LABORATORY PAR Labs Lab Cert. # 20 RECEIVED JUN 1. 4 2021 CENT['<AL FILES DWR SE-CTION Part A: Stormwater Benchmarks and Monitorint= Results SAMPLE COLLECTION YEAR 2021 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or 0 Monthly' month DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other FACILITY ACTIVITIES INCLUDE (check all that apply): l■❑ use/process meats * use animal fats/byproducts PLEASE REMEMBER TO SIGN ON THE REVERSE 4 Total event rain foil Z or n No discharge this ioeriod3 Outfall No. Date Sample Collected, mo/dd/yr TSS, mg/L pH, Standard units COD, mg/L Oil and Grease, mg/L Fecal Coliform, Colonies per 100 ml Enterococci, Colonies per 100 ml Benchmark - 100 or 504 Within 6.0-9.0 120 30 10001 5001 Parameter Cade - C0530 00400 00340 00556 31616 61211 C07 5.12.2021 270 6.77 125 15 21 009 5.12.2021 32 7.04 57 <5.3 6 010 5.12.2021 14 7.02 21 <5.3 <2 1 Only applies to facilities that use/process meats. 2The total precipitation must be recorded using data from an on -site rain gauge. 'For sampling periods with no discharge at aM outfalls. You must still submit this discharge monitoring report with a checkmark here. 4See General Permit text, Table 1, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new oil per month? ■❑ yes ❑ no (± yes, complete Part B) Permit Date: 11/1/2018-05/31/2021 SWU-249, Last Revised 11/5/2018 Page 1 of 2 Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new motor oil/month. Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, inches' New Motor Oil or Hydraulic Oil Usage Non-Polar,b&G/Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - - 15 r0i g/L 100 mg/L or 50 mg/V Parameter Code - 46529 NCOIL 00452 C0530 010 5.12.2021 .4 1,100 gal <5.3 14 Footnotes from Part A also apply to Part B *FOR PART A AND PART B MONITORING RESULTS: * A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ❑ NO REGIONAL OFFICE CONTACT NAME: Mail an original copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the tab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisD=ent for knowing violations." (Z,-�,q�L (2 -zr Sig ature of Oermittee Date SWU-249, Last Revised 11/5/2018 Page 2 of 2 AL PROM PT•ACCU RATE -RE LIABLE LABORATORIES) INC WW W.PAIU ABS.COM REPORT OF ANALYSES Attn: RONALD SELL TYSON FOODS-MONROE PO BOX 965 MONROE, NC 28110-0965 PROJECT NAME: MAY 21 DATE: 05/24/21 SAMPLE NUMBER- 141684 SAMPLE ID- STORMWATER #7 SAMPLE MATRIX- WW DATE SAMPLED- 05/12/21 TIME SAMPLED- 1020 DATE RECEIVED- 05/12/21 SAMPLER- RS RECEIVED BY- DJ TIME RECEIVED- 1505 DELIVERED BY- RB TYPE SAMPLE- Grab Page 1 of 3 ANALYSIS ANALYSIS METHOD DATE TIME BY RESULT UNITS FIELD TEMPERATURE THERM. 05/12/21 1020 RB 17.3 degrees C pH VALUE SM 4500H-B 05/12/21 1020 RB 6.77 units CHEM.OXY.DEMAND EPA 410.4 05/19/21 0650 CT 125 mg/L FECAL COLIFORM SM 9222 D 05/12/21 1520 RE 21 coi/100mLs OIL & GREASE EPA 1664 05/19/21 0845 CT 15 mg/L TOTAL SUSPENDED SOLIDS SM 2540 D 05Y17121 0815 DJ 270 rag/L LABORATORY DIRECTOR 2217 Graham Park Drive • Charlotte, NC 28273 Phone: (704) 588-8333 • Fax: (704) 588-8335 PLLR PROMPT. ACCN RATE. RELIABLE ]LABORATORIES, INC WWW.PARLABS.CONI REPORT OF ANALYSES Attn: RONALD BELL TYSON FOODS-MONROE PO BOX 965 MONROE, NC 28110-0965 PROJECT NAME: MAY 21 DATE: 05/24/21 SAMPLE NUMBER- 141685 SAMPLE ID- STORM -WATER #9 SAMPLE MATRIX- WW DATE SAMPLED- 05/12/21 TIME SAMPLED- 1010 DATE RECEIVED- 05/12/21 SAMPLER- RB RECEIVED BY- DJ TIME RECEIVED- 1505 DELIVERED BY- RB TYPE SAMPLE- Grab Page 2 of 3 ANALYSIS ANALYSIS METHOD DATE TIME BY RESULT UNITS FIELD TEMPERATURE THERM. 05/12/21 1010 RB 18-6 degrees C pH VALUE SM 450OH-B 05/12/21 1010 RB 7.04 units CHEM.OXY.DEMAND EPA 410.4 05/19/21 0650 CT 57 mg/L FECAL COLIFORM SM 9222 D 05/12/21 1520 RE 6 0ol/100mLs OIL 8 GREASE EPA 1664 05/19/21 0845 CT c 5.3 mg/L TOTAL SUSPENDED SOLIDS SM 2540 D 05/17/21 0815 DJ 32 mg/L LABORATORY DIRECTOR 2217 Graham Park Drive • Charlotte, NC 28273 Phase: (704) 588-8333 • Fax: (704) 588-8335 PA&R PROMPT•ACCLI RATE • RELIABLE LABORATOILIES, IWC W W W.PARLABS.COM REPORT OF ANALYSES Attn: RONALD BELL TYSON FOODS-MONROE PO BOX 965 MONROE, NC 28110-0965 PROJECT NAME: MAY 21 DATE: 05/24/21 SAMPLE NUMBER- 1416B6 SAMPLE ID- STORMWATER 410 SAMPLE MATRIX- WW DATE SAMPLED- 05/12/21 TIME SAMPLED- 1030 DATE RECEIVED- 05/12/21 SAMPLER- RB RECEIVED BY- DJ TIME RECEIVED- 1505 DELIVERED BY- RB TYPE SAMPLE- Grab Page 3 of 3 ANALYSIS ANALYSIS METHOD DATE TIME BY RESULT UNITS FIELD TEMPERATURE THERM. 05/12/21 1030 RB 15.1 degrees C pH VALUE SM 450OH-B 05/12/21 1030 RB 7.02 units CHEM.OXY.DEMAND EPA 410.4 05/19/21 0650 CT 21 mg/L FECAL COLIFORM SM 9222 D 05/12/21 1520 RE < 2 col/100mLs OIL & GREASE EPA 1664 05/19/21 0845 CT < 5.3 mg/L TOTAL SUSPENDED SOLIDS SM 2540 D 05/17/21 0815 DJ 14 mg/L LABORATORY DIRECTOR?- 2217 Graham Park Drive • Charlotte, NC 28273 Phone: (704) 588-8333 - Fox. (704) 588-8335 May/12/2021 10-45-33 AM PAP . IABOR+ITpCl4.1NG www.padabs:sam Shipping: 2217 Graham Park Drive Charlotte, NC 28273 It a asnahl that a!! I affril ion be t:�oNna Elapartitrre a envkonmmr Company Mme (billInill Tyson Foods (Monroe' PO Box 965 City, State k zip tode Monroe, NC 28111 Point of Contact a Telephone Numb iieflRlti 6 Sample Taken By: PRINTED NAME Tyson Foods, Inc. 111 -111 .1111 1I1 CHAIN OF CUSTODY PAR Laboratories, Inc Phone (704) 588-8333 FaX p04) 588.8335 Mailing: PD Box 411483 Charlotte, NC 28241.1483 tad on Utle ah.* or Ow" eocurnent far soaptaaa by Par+ ubomWoss, trta end eut Nnrei TURE 7 —re.? - -w to —tar%f - ARE SAMPLES FOR STATE or EPA REPORTING? YES X NO 63errtpte Type: Dw ww rt.�c /w Hw sots oituf Sample Temp at time of sampling: • C Sarnpia 'tamp upon receipt." ���• C •`Field Preserved: Ye No Teflon LinsdZsro Headapaao: you No We Residual Chlorine checked at time of sampling (YIN): Dechlorination Necessary (YIN): nt Samp% I.D; 'ampt! LaMixt 1 Numbrrl camp Grob Pia"N. Slit Di— netwTi me altecGcn DaNYTErne wa equeatae r 41 X F 'i-a e oK W 4 hr 4417 7 �• /.� 04 fi COD'PH �+ ! t' r m +r P r 44 D * G r. s4- a^, yr r t0 ly s+15 r r.ti w,r kr rsorur4wa UiralFrfna R�Gavly Cy: �� DeIElTlnse ,/Li 12 0 -r-- allnq�ohacl by: Daislrlme Rs nr�d trr. % r DetefTime J C-Compodla Q-Gmb OW-OdnWng WatasubWw 4mWwstar OWMW-droandwatar Njbnttoring Well NW-Hozaraaut West*