HomeMy WebLinkAbout780015_Compliance Inspection_20210601Division of Water Resources
Division of Soil and Water Conservation
Other Agency
Facility Number: 780015
Facility Status: Active
Permit: AWS780015 Denied Access
Inspection Type: Compliance Inspection Inactive Or Closed Date:
Reason for Visit: Routine
Date of Visit: 06/01/2021
Farm Name: Farm 7442
County:
Robeson
Region:
Entry Time: 08:00 am Exit Time: 4:00 pm Incident #:
Owner: Murphy -Brown LLC
Mailing Address: PO Box 487
Owner Email:
Fayetteville
Phone: 910-296-1800
Warsaw NC 283980487
Physical Address: Sr1980 2673-B Oakland Rd Saint Pauls NC 28384
Facility Status:
Location of Farm:
Compliant Not Compliant
Integrator:
Latitude:
95 south from fayetteville. left on 1726 to 1980. farm on left 1.5 miles.
Murphy -Brown LLC
34° 49' 32"
Longitude: 78° 56' 37"
Question Areas:
▪ Dischrge & Stream Impacts
▪ Records and Documents
▪ Waste Col, Stor, & Treat
▪ Other Issues
Waste Application
Certified Operator:
Secondary OIC(s):
Gearld Knight
Operator Certification Number: 995580
On -Site Representative(s): Name Title Phone
24 hour contact name Mike Cudd
On -site representative Mike Cudd
Primary Inspector:
Inspector Signature:
Secondary Inspector(s):
Katie Fontenot
Phone: 910-433-3327
Date:
Inspection Summary:
#15. cut and spray the spray fields it needs weed control.
Page 1 of 5
Permit: AWS780015
Inspection Date: 06/01/21
Owner: Murphy -Brown LLC
Facility Number: 780015
Inspection Type: Compliance Inspection Reason for Visit: Routine
Waste Structures
Type
Identifier
Effective
Date
Built
Date
Closed Designated
Date Freeboard
Observed
Freeboard
Lagoon
7442-1
11/29/2005
D1/01/1993
20.04
56.00
Lagoon
7442-2
06/07/2006
D1/01/1993
19.92
50.00
Lagoon
7442-3
06/07/2006
19.50
Lagoon
7442-4 ISOLATION
06/07/2006
19.50
Lagoon
7442HB
06/19/1995
19.50
67.00
Lagoon
7442N
03/04/2005
19.50
Lagoon
7442S
03/04/2005
19.50
Lagoon
ISOLATION
11/29/2005
19.50
Page 2 of 5
Permit: AWS780015
Inspection Date: 06/01/21
Owner: Murphy -Brown LLC
Facility Number: 780015
Inspection Type: Compliance Inspection Reason for Visit: Routine
Discharges & Stream Impacts
1. Is any discharge observed from any part of the operation?
Discharge originated at:
Structure
Application Field
Other
a. Was conveyance man-made?
b. Did discharge reach Waters of the State? (if yes, notify DWQ)
c. What is the estimated volume that reached waters of the State (gallons)?
d. Does discharge bypass the waste management system? (if yes, notify DWQ)
2. Is there evidence of a past discharge from any part of the operation?
3. Were there any observable adverse impacts or potential adverse impacts to Waters of the
State other than from a discharge?
Waste Collection, Storage & Treatment
4. Is storage capacity less than adequate?
If yes, is waste level into structural freeboard?
5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ larc
trees, severe erosion, seepage, etc.)?
6. Are there structures on -site that are not properly addressed and/or managed through a
waste management or closure plan?
7. Do any of the structures need maintenance or improvement?
8. Do any of the structures lack adequate markers as required by the permit? (Not applicablE
to roofed pits, dry stacks and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require
maintenance or improvement?
Waste Application
10. Are there any required buffers, setbacks, or compliance alternatives that need
maintenance or improvement?
11. Is there evidence of incorrect application?
If yes, check the appropriate box below.
Excessive Ponding?
Hydraulic Overload?
Frozen Ground?
Heavy metals (Cu, Zn, etc)?
PAN?
Is PAN > 10%/10 lbs.?
Total Phosphorus?
Failure to incorporate manure/sludge into bare soil?
Outside of acceptable crop window?
Evidence of wind drift?
Application outside of application area?
Yes No NA NE
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
Yes No NA NE
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
Yes No NA NE
❑ • ❑ ❑
❑ • ❑ ❑
Page 3 of 5
Permit: AWS780015
Inspection Date: 06/01/21
Owner: Murphy -Brown LLC
Facility Number: 780015
Inspection Type: Compliance Inspection Reason for Visit: Routine
Waste Application
Crop Type 1
Crop Type 2
Crop Type 3
Crop Type 4
Crop Type 5
Crop Type 6
Soil Type 1
Soil Type 2
Soil Type 3
Soil Type 4
Soil Type 5
Soil Type 6
14. Do the receiving crops differ from those designated in the Certified Animal Waste
Management Plan(CAWMP)?
15. Does the receiving crop and/or land application site need improvement?
16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre
determination?
17. Does the facility lack adequate acreage for land application?
18. Is there a lack of properly operating waste application equipment?
Records and Documents
19. Did the facility fail to have Certificate of Coverage and Permit readily available?
20. Does the facility fail to have all components of the CAWMP readily available?
If yes, check the appropriate box below.
WUP?
Checklists?
Design?
Maps?
Lease Agreements?
Other?
If Other, please specify
21. Does record keeping need improvement?
If yes, check the appropriate box below.
Waste Application?
Weekly Freeboard?
Waste Analysis?
Soil analysis?
Waste Transfers?
Weather code?
Yes No NA NE
Bermuda Grass (Hay,
Pasture)
Small Grain (Wheat, Barley,
Oats)
Wagram loamy sand, 0 to
6% slopes
Norfolk and Faceville soils,
6 to 10% sl
❑ • ❑ ❑
• ❑ ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
Yes No NA NE
❑ • ❑ ❑
❑ • ❑ ❑
Page 4 of 5
Permit: AWS780015
Inspection Date: 06/01/21
Owner: Murphy -Brown LLC
Facility Number: 780015
Inspection Type: Compliance Inspection Reason for Visit: Routine
Records and Documents
Rainfall?
Stocking?
Crop yields?
120 Minute inspections?
Monthly and 1" Rainfall Inspections
Sludge Survey
22. Did the facility fail to install and maintain a rain gauge?
23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipmen
(NPDES only)?
24. Did the facility fail to calibrate waste application equipment as required by the permit?
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the
appropriate box(es) below:
Failure to complete annual sludge survey
Failure to develop a POA for sludge levels
Non -compliant sludge levels in any lagoon
List structure(s) and date of first survey indicating non-compliance:
26. Did the facility fail to provide documentation of an actively certified operator in charge?
27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification?
Other Issues
28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document
and report mortality rates that exceed normal rates?
29. At the time of the inspection did the facility pose an odor or air quality concern? If yes,
contact a regional Air Quality representative immediately.
30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit
(i.e., discharge, freeboard problems, over -application)
31. Do subsurface tile drains exist at the facility?
If yes, check the appropriate box below.
Application Field
Lagoon / Storage Pond
Other
If Other, please specify
32. Were any additional problems noted which cause non-compliance of the Permit or
CAW M P?
33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative?
34. Does the facility require a follow-up visit by same agency?
Yes No NA NE
El
El
El
El
El
❑ • ❑ ❑
El
El
El
Yes No NA NE
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
Page 5 of 5