Loading...
HomeMy WebLinkAboutNCG030130_2021 DMR_20210603SHIELD ENGINEERING May 24, 2021 Mr. Ryan Pennington Gastonia Components and Logistics Daimler Trucks North America, LLC 1400 Tulip Drive Gastonia, NC 28052 Subject: Semi -Annual Sampling -- May 2021 NPDES General Permit No. NCC030000 - CoC No. NCG030130 Daimler Trucks, Gastonia Components and Logistics, LLC 1400 Tulip Drive Gastonia, North Carolina Shield Project No. 1140099-09 Dear Mr. Pennington: Shield Engineering, Inc. (Shield) successfully collected the semi-annual stormwater samples for Stormwater Discharge Outfall (SDO) #002 at the Daimler Trucks Gastonia facility during the month of May 2021. During the May 3'4 sampling event, Shield's measurement for pH was 7.5 at SDO #002. The Qualitative Monitoring Report and a partially completed Discharge Monitoring Report (DMR) form are attached to this cover letter. In addition, the analytical results for the stormwater samples collected during the qualifying storm events are attached to this cover letter. Results from the May 3`d sampling event show an exceedance of TSS at SDO #002. The rain event on May V did not produce enough rain in order to collect the semi-annual stormwater samples for Stormwater Discharge Outfall SDO #003. Shield will continue to monitor daily weather conditions and continue coordination of appropriate staff and resources to collect stormwater samples at this outfall, for the 1" semi-annual period (January — June 2021). Note that SDO #001 was sampled for the 1 S` semi-annual period in January 2021. The person designated to act as the permittee by Daimler Trucks — Gastonia Facility should sign page 1 of the attached DMR. The signed DMR form should then be mailed to the regulatory agency regional office at Mooresville, NC. Shield greatly appreciates the opportunity to provide environmental services to Daimler Trucks of North America. If you have any questions in reference to this document or require further information, please feel free to contact either of the undersigned at (704) 394-6913. Respectfully, SHIELD ENGINEERING, INC. f Magdaline zannis Senior Project Manager Melinda �Grec�ncj Senior Engineer e2crtL. Griffin, PE President/CEO Attachments: Stormwater DMR, Qualitative Monitoring Report, Analytical Results 4301 Taggart Creek Road www.shieldenpineering.com Telephone 704.394.6913 Charlotte, NC 28208 NCDEQ Division of Energy, Mineral and Land Resources 5tormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions J Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit ❑ata Monitoring Report (OMR) Upload form within li 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0130 Facility Name: Daimler Trucks - Gastonia Facility County: Gaston Person Collecting Samples: TJ Gladden Laboratory Name: Pace Analytical Laboratory Cert. No.: 329 -- i Discharge during this period: El Yes No (if no, skip to signature and date) i Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ❑ Yes R1 No — if If so, which Tier (1, ll, or 11I)? A copy of this DMR has been uploaded electronically via htt s: edocs-den. nc.gov_jForms/5W-DMR ❑ Yes C] No DateUploaded: (� f 3�2� Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall001 Outfall002 Outfall003 f outfaii Cade Outfall N/A Receiving Stream Class T C C C N/A Uate Sample Collected MM/DD/YYYY NA 5/3/2021 NA 46529 24-Hour Rainfall in inches 0.76 ~ C0530 T5S in mg/L (100 or 51D`) 210 00400 pH in standard units (6.0 — 9.0) 7.5 0.0072 01119 Copper, total recoverable in mg/L (O.o10} 0096 01051 Lead, total recoverable in mg/ L ~0 _ _(0.075) i 01094 Zinc, total recoverable in mg/ L ❑ 029 i {0.126) 78141 Total Toxic Organics (TTO) in mg/L(1) a0,19704 (if required) c5.0 DOS 5Z 1 _ Non -Polar 0il & Grease in mg/L(15) Additional parameters for outfalls in drainage areas that use >55 gallons per month of new hydraulic oil on average NCOIL Estimated New Motor/Hydraulic Oil NA NA NA I Usage in gal/month - uottaIIs to ❑utstarid ing Resource waters (0RW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. Ail other water classifications have a benchmark of 100 mg/L Cotes (optional)^Benchmark exceedance for T55 (Outfall 002) "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false informatioryry�ing [he possibility of fines and imprisonment for knowing violations." 1 3 z Signature of Per rttee or Delegated Authorized Individual D to Email Address Phone Number Total Toxic Organics Certification: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no leak, spill, or dumping of concentrated toxic organics into the stormwater or onto areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. i further certify that this facility is implementing all the provisions of the Solvent Man�-RlarLided in the Stormwaier Palfution Prevention Plan." _ 4 ature of Permittee or Delegated Authorized Individual pat Email Address Phone Number