Certificate of Coverage No. NCG03 0698
Person Collecting Samples: Jason Haire
Facility Name: Caterpillar Inc.
Laboratory Name: Pace Analytical Services, LLC
Facility County: Lee
Laboratory Cert. No.:12, 40 , 633
Discharge during this period: r❑ Yes ❑ No (if no, skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ❑ Yes 0 No
If so, which Tier (I, II, or III)?
A copy of this DMR has been uploaded electronically via https.1/edocs.deg-nc.govlFormsl5W-DMR ❑✓ Yes []No
Date Uploaded: 05/28/2021
Analytical Monitoring Requirements for OutfaIIs with industrial Activities — Benchmarks in (Red)
Parameter
Code
Parameter
Outfall 1
Outfall 2
Outfall
Outfall
Outfall
N/A
Receiving Stream Class
C
C
N/A
Date Sample Collected MM/DD/YYYY
05/12/2021
05/12/2021
46529
24-Hour Rainfall in inches
0.09
0.09
C0530
TSS in mg/L (100 or 50*)
9.6 mglL
51.0 mg/L
00400
pH in standard units (6.0 — 9.0)
8.0
7.5
01119
Copper, total recoverable in mg/L
<0 005 mg/L
<0.005 mg/L
(0.010)
01051
Lead, total recoverable in mg/ L
¢0.005 mg/L
<0.005 mg/L
(0.075)
01094
Zinc, total recoverable in mg/ L
0.056 mg/L
<0.01 mg/L
(0.126)
78141
Total Toxic Organics "0) in mg/L(1)
N/A
N/A
(if required)
00552
Non -Polar Oil & Grease in mg/L (15)
<5.0 mg/L
r5.6 mgJL
Additional parameters for outfa[is in drainage areas that use >55 gallons per month of new hydraulic oil on average
NCOIL
Estimated New Motor/Hydraulic Oil
T
I
Usage in gal/month
* OutfaIIs to ❑utstanding Resource Waters (0RW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark T55 limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L
Notes (optional):
"i certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the p on or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted,
it , the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false infer Cott 1AcludiU th"ossibility of fines and imprisonment for knowing violations."
5ignat'bre of Perm
Email Address
Authorized Individual
/a 2elo2:p2-
Dat
Phone Number
Total Toxic Organics Certification:
"Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring
requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no leak, spill, or dumping of
concentrated toxic organics into the stormwater or onto areas which are exposed to rainfall or stormwater runoff has occurred since
filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the Solvent
Man�geme t Plan included in the Stormwater Pollution Prevention Plan."
_)
Signature of Permittee or Delegated Authorized Individual Date
Email Address Phone Number