Loading...
HomeMy WebLinkAbout20161072 Ver 2_Riparian Buffer Authorization Request_20210607Buffer Authorization Application Form 15ANCPG 02B .0233 (8)(b), .0243 (8)(b), .0250 (11)(b), .0259 (8)(b), .0267 (11)(c), .0607 (e)(2) Buffer Authorization Online Form - Update 10/23/2018 Water Resources ENVIRONMENTAL QUALITY Original Submittal 6/7/2021 A. Owner/Applicant Information General Information Primary Contact Email:* Who is submitting the application?* 1. Property Owner Information: la. Name on Recorded Deed:* 1b. Responsible Party: lc. Mailing Address:* Id. Telephone:* (919)291-6738 3. Agent Information: 3a. Name: 3b. Company Affiliation: sydni.law@timmons.com Please list the contact person's email for questions or payrrent on this project if needed. r Owner r Applicant other than Owner 17 Agent GFR Properties, LLC Geff Rucker (for Corporations) Street Address 1418 Aversboro Road Address Line 2 Clty State / Ftovince / Region Garner NC Fbstal / Zip Code Country 27529-3981 US 3c. Mailing Address: Street Address Address Line 2 aty Fbstal / Zip Code 3d. Telephone: 1e. Email Address:* gruckerhomes@gmail.com 3e. Email Address: State / Ftovince / Region Country 3f. Attach a signed and dated copy of the agent aick the upload button or drag and drop files here to attach docurrent authorization form. FDFCnly B. Project Information and Prior Project History 1. Project Information la. Name of Project:* Leighson Landing (Subdivision, facility, or establishment nave) 1b. Is this a publicly -funded transportation project?* f Yes C- No Id. Subdivision Name: Leighson Landing le. Nearest Municipality: Garner If. Property Size: 1.66 acres lg. County (or Counties) where the project is located:* Wake 1h. PropertylD# 1710374934 Tax RN or Parcel id 1 i. Deed Information Date of Purchase 6/25/2003 Type of Book Book# Page# Deed 010219 01519 Map J 1j. Attach a copy of the recorded map that indicates when the lot was last platted. dick the upload button or drag and drop files here to attach document FDF only 1k. How would you like to provide the Latitude and Longitude information?* r Address Lookup F Manually Latitude * 35.694537 Longitude * 11. Is the project located in any of North Carolina's twenty coastal counties?* r Yes 4 No 2. Surface Waters 2a. Name of the nearest body of water to proposed project:* Reedy Branch 2b. Water Quality Classification of nearest receiving water:* WS-III; NSW -78.617918 2c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property:* 21 (linear feet only) 3. Project Description: 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: The project site encompasses approximately 1.66 acres located to the south of Poole Drive, west of Aversboro Road in Garner, Wake County, North Carolina. The project site is currently undeveloped with successional forest approximately 10 to 15 years in age located across the majority of the site, with older mixed hardwood forests located along the western site boundary. A delineation of the site was completed by Timmons Group on March 23, 2021, which identified one main stream segment along the northwestern site boundary and continuing off -site within 50-ft of the western boundary. A smaller stream segment flows east to west from an off -site culvert into the stream feature in the northwestern corner of the site. No wetland features were identified within the site. The proposed project will avoid impacts to the aforementioned stream features and result in minor impacts to stream buffers within the southwestern portion of the site. 3b. Attach an 8 1/2 x 11 excerpt from the most recent version of the USGS topographic map indicating the location of the site. Click the upload button or drag and drop files here to attach docurrent Figure 1 - VIC.pdf 931.46KB IMF only 3c. Attach an 8 1/2 x 11 excerpt from the most recent version of the published County NRCS Soil Survey Map depicting the project site. Click the upload button or drag and drop files here to attach docurrent Figure 5 - NRCS.pdf FDF only 4. Proposed Activity 688.2KB Provide a detailed description of the proposed activity including its purpose and include the type of equipment to be used:* The purpose of the proposed project is to construct an affordable and family - friendly residential subdivision with community cohesion and the necessary amenities within the southern section of the Town of Garner, designed to provide housing to the southeastern portion of Wake County, North Carolina. Attach a site plan as applicable to the project: Oickthe upload button or drag and drop files here to attach docurrent Leighson Landing_Proposed Site Plans.pdf Figure 7 - WTIM.pdf ItF only 5. Jurisdictional Determinations 2.39MB 1.27MB 5a. Have jurisdictional wetlands or stream determinations by the Corps or State been requested or obtained for this property/project (including all prior phases) in the past?* 5b. Who did the determination on the jurisdictional areas? Who did the determination? List name if known Date Attach Corps David Bailey (IVnrre if known) 04/29/2021 Leighson Landing_SAW- 2021-00877 Confirmation.p.. 118.9.. Figure 6 - WTDM.pdf 2.93M. pdf oriN State Andrew Kiley (N}arre f (mown) 05/27/2021 Leighson Landing_Buffer Determination Letter.pdf pdf only 2.43M. *** Please include the date of the determination and upload a copy of the determination. Comments: 6. Project History 6a. Have permits or certifications been requested or obtained for this project (including all prior phases) in the past?* ✓ Yes ✓ No 7. Future Project Plans 7a. Is this project a phased project?* C. Proposed Impacts Inventory Buffer Impacts c Yes CD No Project is in which protected Basin?* t: Neuse River Basin (15A NCAC 02B.0233) C' Catawba River Basin (15A NCAC 02B.0243) ✓ Randleman Lake Watershed (15A NCAC 02B.0250) ✓ Tar -Pamlico River Basin (15A NCAC 02B.0259) ✓ Jordan Lake Watershed (15A NCAC 02B.0267) ✓ Goose Creek Watershed (15A NCAC 02B.0606 & 15A NCAC 02B.0607) Individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. Site# -Reason Stream Name Buffer Impact* Impact Type* Zone 1 Zone 2 Impact 1 (SCM Conveyance) Map label (e.g. Read dossing 1) A (UT to Swift Creek) Permanent (P) Ibrmor Tenp Allowable w/ mitigation 51.00 Square Fit 0.00 Square Feet Impact 1 (SCM Conveyance) Map label (e.g. Read Crossing 1) A (UT to Swift Creek) Permanent (P) 1=brmor Tenp Allowable 0.00 Square Feet 684.00 Square Feet Total Zone 1 Impacts: 51.00 Total Zone 2 Impacts: 684.00 Total Buffer Impacts: 735.00 Comments: The proposed Leighson Landing residential development will consist of 4 multi- family housing buildings with a total of approximately 12 townhome units and associated amenities, including roadway, stormwater control measures (SCMs), and utility improvements (i.e. public water supply and sanitary sewer alignment). The proposed project requires installation of SCMs to treat the drainage area in compliance with the Town of Garners state -approved stormwater program. As a result, one bioretention pond, located in the southwestern corner of the site, is proposed with a drainage conveyance and riprap dissipater pad to treat stormwater from the project drainage area and allow for diffuse flow into Zone 1 of the riparian buffer. The proposed drainage conveyance will also provide a bypass of existing stormwater drainage from off -site areas upslope of the site. Stormwater conveyed through the bypass from off -site areas will not be treated by the proposed SCM. The proposed impact will result in 684-sq.ft. of permanent Zone 2 and 51-sq.ft. of permanent Zone 1 buffer impacts. Impacts to Zone 2 are Allowable, while impacts to Zone 1 are allowable with mitigation since the impact will require vegetation removal for riprap pad installation. No additional impacts to Waters of the US are proposed. The proposed project is a single and complete phase with appropriate land use control measures in place for specific areas which require them. Traditional equipment will be used consisting of front-end loaders, bulldozers, paving equipment, graders, and earth movers. D. Impact Justification and Mitigation 1. Avoidance and Minimization la. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project.* Impacts to jurisdictional features have been avoided and minimized to the maximum extent practicable by incorporating resourceful site planning, including the utilization of the wetland delineation to adjust the layout to avoid and minimize impacts. Avoidance and minimization measures were also accomplished during the design phase of the project. The proposed impacts are required in order for the project's goals to be realized. The proposed bioretention pond and new stormwater conveyance are required by the Town of Garner's state -approved stormwater management plan to treat stormwater from the drainage area before being discharged to nutrient sensitive waters. Additional impacts to riparian buffers were avoided by bypassing stormwater flow from upstream properties through the site to the proposed stormwater conveyance, reducing the necessary number of conveyances through the riparian buffer. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques.* Proper sedimentation and erosion control methods will be utilized during all phases of construction and installation as described in accordance with the requirements of the North Carolina Department of Environment and Natural Resources: Erosion Control Planning and Design Manual (May 2013) and local codes. All work will take place during dry conditions and can be facilitated from high, non -jurisdictional, stable ground. The contractor shall install silt fence, inlet protection, sediment traps, diversion ditches, temporary coffer dams, tree protection, and clearing only as necessary to install devices. All erosion and sediment control measures will be checked for stability and operation following every runoff producing rainfall, but in no case less than once every week. Any needed repairs will be made immediately to maintain all measures designed. An erosion control inspections report is required and will be kept by the owner's representative. Temporary seeding and permanent seeding plans are included to restore impacted areas. The project will meet all relative requirements of Best Management Practices and Engineered Stormwater Control Structures as outlined through State and Local Stormwater Rules. Measures will be taken to prevent oil, tar, trash, debris, and other pollutants from entering the adjacent jurisdictional features. Any excess excavated materials not utilized as back fill will be placed and contained within upland areas and permanently stabilized to prevent erosion into adjacent jurisdictional features. Therefore, stockpiling of excavated material within jurisdictional Waters of the US will be strictly prohibited as part of the construction of this project. All project construction activities initiated within jurisdictional Waters of the US will be carried to completion in an expeditious manner to minimize the period of disturbance within the jurisdictional streams. Disturbed portions of Zone 1 and Zone 2 will be seeded and stabilized immediately following disturbance. 2. Buffer Mitigation 2a. The table below identifies the square footage of impact to each zone of the riparian buffer and the required mitigation. Zone 1 Total Impact Multiplier Required Mitigation 51.00 Square Feet 3 153 Square Feet Zone 2 Total Impact Multiplier Required Mitigation 0.00 Square Feet 1.50 0.00 Square Feet 2b. What is the mitigation plan proposed for this project?* ▪ Payment to private mitigation bank ❑ Payment to Division of Mitigation (DMS) ❑ Permittee responsible mitigation 2e. Attach statement of availability from mitigation provider.* aick the upload button or drag and drop files here to attach docurrent RES Buffer SOA - Leighson Landing.pdf 119.18KB FwF only 2g. Comments: E. Diffuse Flow Plan Payment to a private mitigation bank, Resource Environmental Solutions, LLC (RES) for the required amount of credits. la. What type of SCM are you providing?* ✓ Level Spreader ✓ Vegetated Conveyance (lower SHWT) ✓ Wetland Swale (higher SHWT) ✓ Proposed project will not create concentrated stormwater flow through the buffer rJ Other SCM that removed minimum of 30% nitrogen 1b. Describe how diffuse flow will be maintained:* The SCM depicted on sheet C3.0 of the attached plans will control flow leaving the site. The post -development flow from the SCM is providing non -erosive flow with riprap at the culvert outlet. lc. Diffuse Flow Documentation* F. Supplementary Information Environmental Documentation Click the upload button or drag and drop files here to attach docurrent Leighson Landing_Proposed Site Plans.pdf 2.39MB Figure 7 - WTIM.pdf 1.27MB FEF only la. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land? ✓ Yes C' No Violations 2a. Is the site in violation of DWR Wetland Rules (15A NCAC 02H .0500), Isolated Wetland Rules (15A NCAC 02H .1300), DWR Surface Water or Wetland Standards, or Riparian Buffer Rules (15A NCAC 02B .0200)? 2b. Is this an after -the -fact buffer authorization application? 6- No G. Additional Information Please upload any additional information you would like the Division to consider during application review. Additional Attachments: Additional Comments: H. Sign and Submit aick the upload button or drag and drop files here to attach docun ent FEF only By digitally signing below, I certify that: o I have given true, accurate, and complete information on this form; • I agree that submission of this form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act") o I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); o I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND • I intend to electronically sign and submit the application form." Print Name:* Sydni L. Law Signature Submission Date: 06/07/2021 (Auto populated field) Initial Review Is this accepted into the review process?* Is this project a public transportation project? * e Yes O No O Yes e No ID#* 20161072 Version:* 2 Select Reviewer: Stephanie Goss:eads\szgoss Select Reviewing Office * Raleigh Regional Office - (919) 791-4200 Has payment been received?* ( No Payment Needed ✓ Fee Received ✓ Need Fee - send electronic notification fires EBX Buffer Mitigation Banks Statement of Availability June 4, 2021 NC Division of Water Resources Joshua Brigham 512 N. Salisbury St. Archdale Building, 9th floor Raleigh, NC 27604 Re Project: Leighson Landing This document confirms that the GFR Properties, LLC (Applicant) for the Leighson Landing (Project) has expressed an interest to utilize 153.00 Square Feet of Riparian Buffer Mitigation Credits from one or both of the following banks, EBX-Neuse I, LLC Neuse Riparian Buffer Umbrella Mitigation Bank or EBX Upper Neuse Riparian Buffer Umbrella Mitigation Bank. Specific bank sites that will be debited will either be Buffalo Branch, Bucher, Selma Mill, Cedar Grove, Polecat, Stone Creek, Hannah Bridge, Meadow Spring, Poplar Creek, Uzzle and/or Hatley, all located in HUC 03020201. As the official Bank Sponsor, EBX-Neuse I, LLC and EBX, attests to the fact that mitigation is available for reservation at this time. These mitigation credits are not considered secured, and consequently are eligible to be used for alternate purposes by the Bank Sponsor, until payment in full is received from the Applicant resulting in the issuance of a Mitigation Credit Transfer Certificate by the bank acknowledging that the Applicant has fully secured credits from the bank and the Banker has accepted full responsibility for the mitigation obligation requiring the credits/units. The Banker will issue the Mitigation Credit Transfer Certificate within three (3) days of receipt of the purchase price. Banker shall provide to Applicant a copy of the Mitigation Credit Transfer Certificate and a documented copy of the debit of credits from the Bank Official Credit Ledger(s), indicating the permit number and the resource type secured by the applicant. A copy of the Mitigation Credit Transfer Certificate, with an updated Official Credit Ledger will also be sent to regulatory agencies showing the proper documentation. Please contact me at 919-209-1075 or cparker@res.us if you have any questions or need additional information. Best Regards, Caitlan B. Parker Resource Environmental Solutions, LLC 701 E. Bay Street, Suite 306 Charleston, SC 29403 Bank Sponsor — EBX-Neuse I, LLC or Environmental Banc & Exchange (EBX) Path: Y:\805\37931 - Leighson Landing\GIS\37931-JD-VIC.mxd FRANCES DR pooLE DP ~rWOOD DR Site limits are survey located by Timmons Group. Topographic imagery from USGS. wADE AVE PHILLIP ST -57 -17 BERKSHIRE DR cl BEELEAPIS m<. Site Limits HEATHER PARK DP Av ersboro : Elem Sch LAWNDALE ST LAKESIDE lR LEIGHSON LANDING WAKE COUNTY, NORTH CAROLINA FIGURE 1: VICINITY MAP TIMMONS GROUP JOB NUMBER: 37931 PROJECT STUDY LIMITS: 1.66ACRES LATITUDE: 35.694537 LONGITUDE: -78.617918 TIMMONS GROUP ••••••a YOUR VISION ACHIEVED THROUGH OURS. I U.S.G.S. QUADRANGLE(S): GARNER DATE(S): 2019 WATERSHED(S): UPPER NEUSE (NEUSE RIVER BASIN) HYDROLOGIC UNIT CODE(S): 03020201 ese p ans an. associate. •ocuments are t e exc usrve property o ♦V.' •.U• an• may not e repro uce in w o e or in part an s a not e use. or any purpose w atsoever, Inc usrve, •ut not • limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. Path: Y:1805\37931 - Leighson Landing \GIS137931-JD-NRCS.mxd LEIGHSON LANDING WAKE COUNTY, NORTH CAROLINA FIGURE 5: NRCS MAP TIMMONS GROUP JOB NUMBER: 37931 PROJECT STUDY LIMITS: 1.66ACRES LATITUDE: 35.694537 LONGITUDE: -78.617918 Th ese p ans an ocuments are the exclusive property of TIMMONS GROUP and may not be reproduced in whole limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. TIMMONS GROUP YOUR VISION ACHIEVED THROUGH OURS. U.S.G.S. QUADRANGLE(S): GARNER DATE(S): 2019 WATERSHED(S): UPPER NEUSE (NEUSE RIVER BASIN) HYDROLOGIC UNIT CODE(S): 03020201 d shall no[ be used fo • d associated d or in part an r any purpose whatsoever, inclusive, but not mmc alga riallanaralEiga ilia Resource Identification A Total PF0 (sq ft) PSS (sq ft) Total Wetland Area = Total Stream Area = Total Stream Length= PEM (sq ft) POW (sq 0 sgft 68 sgft 21 If Confirmation R3 (Iry 14 21 R4 (Iry Rfi Of/ 0.00 ac 0.00 ac Ditch Of/ Stream (sq ft) 54 14 fib Resource Description Notes' NT/NV NT/NV T=Tidal; NT=Non-tidal; V=Vegetated; NV=Non-Vegetated, PFO=Palustrine Forested Wetland; PSS=Palustrine Scrub -Shrub Wetland; PEM=Palustrine Emergent Wetland; POW= Palustrine Open Water; EMS Estuarine Intedidal Wetlands; R3= Upper Perennial Streams; R4=Intermittent Streams; R6 = Ephemeral Streams Legend "(Project Study Limits - 1.66 Acres © Stream Identifier © Wetland Identifier Flag 4 Field Data Station Stream Buffer Perennial Stream (R3) Culvert Topographic Contours Major - 10 Feet Minor - 1 Foot 1. Waters of the U.S. within the project study limits have been located using submeter, Bluetooth GPS antennas by Timmons Group. 2. Waters of the U.S. have not been confirmed by the U.S. Army Corps of Engineers until stamped. 3. Project limits are survey located by Timmons Group. 4. Topography based on USGS LiDAR. 5. Cowardin Stream Classifications are based on NC DWQ Stream Identification form version 4.11. 0 20 40 Feet 80 ... • • ••• TIMMONS GROUP TOUR VISION ACHIEVED THROUGH OURS. Confirmation #: SAW-2021-00877 Confirmation Date: April 29, 2021 x a 5 • • w • • NVAMEOZ1 *-14:1191EOZ a DATE 03/30/2021 DRAWN BY K. SCHMIDT DESIGNED BY K. SCHMIDT CHECKED BY S. LAW SCALE 1 "=40' gNIMMaa►il WilmRWe1miTiVil nazi 4101Will iEC0I0AM JOB NUMBER 37931 SHEET NO. 1 OF 1 Impacts Table Impact ID Stream Buffer (sq. ft) Zone 1 Zone 2 Temporary Permanent Temporary Permanent 1 51 684 Total 0sgft 51 sq ft 0sgft 684sgft 0.00 ac 0.001 ac 0.00 ac 0.02 ac Legend LOD aol LOD Project Study Limits - 1.66 Acres Limits of Disturbance - 1.47 Acres O Stream Buffer Impact - Stream Buffer Culvert Perennial Stream (R3) Zone 1 Impact Zone 2 Impact Existing Grading Proposed Sanitary Sewerpipe Proposed Stormpipe -------- Proposed Waterline Proposed Grading Proposed RIPRAP 0 \,.00 v.00 v.00 0 f •• • • • • • • • 0 D 0 z 0 YOUR VISION ACHIEVED THROUGH OURS. .timmons.com PROJECT NAME & LOCATION 0 z 0 z J z 0 co 0 W J • z z0 O < 00 O z DATE 05/27/2021 PROJECT NUMBER 37931 PROJECT NAME LEIGHSON LANDING DESIGNED BY / DRAWN BY A. MEHFOUD 1. Waters of the U.S. within the project study limits have been located using submeter, Bluetooth GPS antennas by Timmons Group. 2. Waters of the U.S. have not been confirmed by the U.S. Army Corps of Engineers. 3. Project limits are approximate. 4. Topography based on USGS Li DAR. 5. Cowardin Stream Classifications are based on NC DWQ Stream Identification form version 4.11. These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. REVISIONS a MM/DD/YY DESCRIPTION DRAWING DESCRIPTION FIGURE 7: WETLANDS AND WATERS IMPACTS MAP (F) SCALE (FEET) 0 20 40 PLANS PRINTED AS 11X17 ARE HALF SCALE SCALE H:1 "=20' SHEET NUMBER 1 Y:\805\37931 - Leighson Landing\GIS\WTIM\37931-PERM-WTIM.mxd Impacts Table Impact ID Stream Buffer (sq. ft) Zone 1 Zone 2 Temporary Permanent Temporary Permanent 1 51 684 Total 0sgft 51 sq ft 0sgft 684sgft 0.00 ac 0.001 ac 0.00 ac 0.02 ac Legend LOD aol LOD Project Study Limits - 1.66 Acres Limits of Disturbance - 1.47 Acres O Stream Buffer Impact - Stream Buffer Culvert Perennial Stream (R3) Zone 1 Impact Zone 2 Impact Existing Grading Proposed Sanitary Sewerpipe Proposed Stormpipe -------- Proposed Waterline Proposed Grading Proposed RIPRAP 0 \,.00 v.00 v.00 0 f •• • • • • • • • 0 D 0 z 0 YOUR VISION ACHIEVED THROUGH OURS. .timmons.com PROJECT NAME & LOCATION 0 z 0 z J z 0 co 0 W J • z z0 O < 00 O z DATE 05/27/2021 PROJECT NUMBER 37931 PROJECT NAME LEIGHSON LANDING DESIGNED BY / DRAWN BY A. MEHFOUD 1. Waters of the U.S. within the project study limits have been located using submeter, Bluetooth GPS antennas by Timmons Group. 2. Waters of the U.S. have not been confirmed by the U.S. Army Corps of Engineers. 3. Project limits are approximate. 4. Topography based on USGS Li DAR. 5. Cowardin Stream Classifications are based on NC DWQ Stream Identification form version 4.11. These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. REVISIONS a MM/DD/YY DESCRIPTION DRAWING DESCRIPTION FIGURE 7: WETLANDS AND WATERS IMPACTS MAP (F) SCALE (FEET) 0 20 40 PLANS PRINTED AS 11X17 ARE HALF SCALE SCALE H:1 "=20' SHEET NUMBER 1 Y:\805\37931 - Leighson Landing\GIS\WTIM\37931-PERM-WTIM.mxd S:\332\37931-Leighson_Landing\DWG\Sheet\CD\37931-332-CVR-COVR.dwg I Plotted on 5/13/2021 2:28 PM I by Alex May GENERAL NOTES 1. ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE TOWN OF GARNER AND THE STATE OF NORTH CAROLINA STANDARDS AND SPECIFICATIONS. 2. CONTRACTOR SHALL HAVE NORTH CAROLINA ONE CALL (811) LOCATE ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. 3. CONTRACTOR SHALL VERIFY THE LOCATION AND DEPTH OF ALL EXISTING UTILITIES AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO BEGINNING CONSTRUCTION. 4. ALL CONSTRUCTION SHALL CONFORM TO A.D.A. STANDARDS. 5. CONTACT THE NORTH CAROLINA ONE CALL CENTER PRIOR TO DOING ANY DIGGING. 1 00-•3 -49 6. 'LEASE CONTACT TOWN OF ARNEENGINEE'ING D PA'TMEN A ENG-INSPECTIONS@GARNERNC.GOV TO SCHEDULE A PRE -CONSTRUCTION MEETING PRIOR TO OBTAINING BUILDING PERMITS FOR THIS PLAN. INFRASTRUCTURE INSPECTION TABLE CITY OF RALEIGH PUBLIC UTILITIES (6" DIP) PUBLIC WATERMAIN (LF): (10" PVC) PUBLIC SEWERMAIN (LF): (SIZE) PRIVATE WATERMAIN (LF): (SIZE) PRIVATE SEWERMAIN (LF): WATER STUBS/TIES: (3/4") WATER METER FOR DOMESTIC: (SIZE) WATER METER FOR IRRIGATION: SEWER STUBS (4" SERVICES): 312 323 N/A N/A 15 14 N/A 4 KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. LEIGHSON LANDING SITE PLAN MODIFICATION 0 POOLE DRIVE TOWN OF GARNER WAKE COUNTY, NORTH CAROLINA INFRASTRUCTURE INSPECTION TABLE TOWN OF GARNER ENGINEERING PUBLIC STREETS (LF): PUBLIC SIDEWALK (LF): STORMWATER CONTROL MEASURES: N/A 12 1 ARCHITECT CONTACT D&L DESIGN GROUP, INC. PO BOX 445 GARNER, NC 27529 PH. (919) 662-9316 VICINITY MAP NTS OWNER CONTACT GEFF RUCKER HOMES, INC GEFF RUCKER 1418 AVERSBORO ROAD, SUITE 202 GARNER, NC 27529 P H . (919)291-6738 ATTENTION CONTRACTORS THE CONSTRUCTION CONTRACTOR RESPONSIBLE FOR THE EXTENSION OF WATER, SEWER AND/OR REUSE, AS APPROVED IN THESE PLANS, IS RESPONSIBLE FOR CONTACTING THE PUBLIC UTILITIES DEPARTMENT AT (919) 996-4540 AT LEAST TWENTY FOUR HOURS PRIOR TO BEGINNING ANY OF THEIR CONSTRUCTION. FAILURE TO NOTIFY BOTH CITY DEPARTMENTS IN ADVANCE OF BEGINNING CONSTRUCTION, WILL RESULT IN THE ISSUANCE OF MONETARY FINES, AND REQUIRE REINSTALLATION OF ANY WATER OR SEWER FACILITIES NOT INSPECTED AS A RESULT OF THIS NOTIFICATION FAILURE. FAILURE TO CALL FOR INSPECTION, INSTALL A DOWNSTREAM PLUG, HAVE PERMITTED PLANS ON THE JOBSITE, OR ANY OTHER VIOLATION OF CITY OF RALEIGH STANDARDS WILL RESULT IN A FINE AND POSSIBLE EXCLUSION FROM FUTURE WORK IN THE CITY OF RALEIGH. Sheet List Table Sheet Number Sheet Title CVR COVER SHEET C1.0 EXISTING CONDITIONS AND DEMOLITION PLAN C2.0 SITE PLAN C3.0 GRADING AND STORM DRAINAGE PLAN C3.1 PLAN AND PROFILES C3.2 PLAN AND PROFILES C4.0 EROSION CONTROL PLAN - PHASE 1 C4.1 EROSION CONTROL PLAN - PHASE 2 C5.0 UTILITY PLAN C6.0 LANDSCAPE PLAN C6.1 LANDSCAPE DETAILS C7.0 DETAILS C7.1 DETAILS C7.2 DETAILS C7.3 DETAILS C7.4 DETAILS C7.5 DETAILS SHEET 1 OF 1 SITE LIGHTING PLAN SHEET 1 OF 4 BUILDING ELEVATIONS SHEET 2 OF 4 BUILDING ELEVATIONS SHEET 3 OF 4 BUILDING ELEVATIONS SHEET 4 OF 4 BUILDING ELEVATIONS SITE DATA TABLE PROJECT NAME: LEIGHSON LANDING TOWNSHIP: ST. MARY'S ZONING: MF-2 (MULTIFAMILY RESIDENTIAL) CURRENT USE: VACANT PROPOSED USE: TOWNHOMES RIVER BASIN: NEUSE SWC: INS -III; NSW WATERSHED: SWIFT CREEK CIVIL ENGINEER TIMMONS GROUP PATRICK BARBEAU, P.E. 5410 TRINITY RD. STE 102 RALEIGH, NC 27607 PH. (919) 866-4951 PATRICK.BARBEAU@TIMMONS.COM PRELIMINARY - NOT RELEASED FOR CONSTRUCTION ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF GARNER, CITY OF RALEIGH, NCDEQ AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS /A , FNGINE...: Q..: 05�7��2027 THIS DRAWING PREPARED AT THE CORPORATE OFFICE YOUR VISION ACHIEVED THROUGH OURS. REVISION DESCRIPTION 0 a LL 0 0 REVISED PER TOWN OF GARNER COMMENTS w VD ti O VD rn O rn ti O VD O O O 0 C 0 0 Ln DATE 06/17/2019 • • • • • • • • • Z 0 DRAWN BY 332 DESIGNED BY 332 CHECKED BY P. BARBEAU SCALE z 0 z J z 0 w J GARNER DISTRICT - WAKE COUNTY - NORTH CAROLINA COVER SHEET JOB NO. 37931 SHEET NO. CVR 0 C ai N U tts a) O rn to 0 Q 0_ C 0 a) 0 C C 0_ .c 0 0 c 0• O 2 CD 0_0) cD o o � E� -D C N O C a O D U o C • W (0 In Zw o N �a) o,a Q Q0) c .>_ .- (( X C N O O 112N � c w 0 a)o E0 0C U N U c• cb o c- - o O -D to • O C • U a a..) -0 (1)▪ E L_ S:\332\37931-Leighson_Landing\DWG\Sheet\CD\37931-332-C1.0-EXIS.dwg 1 Plotted on 5/13/2021 4:55 PM 1 by Alex May / / / / / / / / / INV, IN / //MH =280.31' / RIM=286.37'` / / / / / / co / / INV, IN �/sq,y =282.17' / / 1' / / / / co 1' / EX, 8' W/L i %%i % / /� j /// / Nl/ i oNP// / / / / /ti 40' UTILITY EASEMENT / / / / co (TOWN OF GARNER / (ZONED MF-2) / PIN 1710 37 2431/ USE: VACANT / EIP / EX. 30" C&G W EXISTIN SAN 8'3U, �00 y g0 r�- -287Or/ - KIMBERL Y WEBB (ZONED NC) PIN 1710 38 5288 C-STORE TBM: TOP FH ELEV=292.83' i 7I STORM MANHOLE RIM=290,16'�- INV, 61_ ._IN 18"RC�Y�1>86,30' -INV, I 6 CP=283,31' _.Nk> UUT 36"RCP=283,17'� W SEWEFZ '�sA�m • 8"P�sAN�' 2�' D01, %-o STORM MH MH RIM: 291.24' / o)ti' IN V IN N: 282.79'=' IN V IN E: 283.79' SIpEWALK l IN V OUT.• 282.66' E c 1g 1 INV=282.317� 1 EX. FES 3 �Q INV=283,03 /�0 o INV IN (SOUTH): 283.55 INV OUT: 282.97/ / / / EIP N. cO /11 / I / / / / "RCP INV=284.61' LEGEND SAN -IN MC 711 vv- PROPERTY BOUNDARY RIPARIAN BUFFER EXISTING SANITARY SEWER EXISTING STORM EXISTING WATER LINE OVERHEAD POWER LINE EXISTING CATCH BASIN EXISTING YARD INLET EXISTING SSMH EXISTING FIRE HYD. EXISTING WATER VALVE k co co / / - 290 - GUY DO1 GA WIRE > DB: 010219, Pg: 01519 1.67 AC (ZONED MF-2) 2,97 / / . / / 1 Iv 1 I clf• ___.________ _____ ____------ _____ _____ ofve ______ _____ 00170,35 9-9) sANI •42- OH P /I* / DO2 /44LNV OUT 181RCP=286.77' / wv GEORGETOWNE MANOR PHASE II, SECTION "C" (ZONED MF-2) k co • 20' TOWN OF GARNER DRAINAGE & UTILITY CJ EIP OF LINE k co Lu Lu L / DO1 C\A TV .."").9,4/v PED. C.M.R. & ASSOCIATES USE: OFFICE BUILDING MH INV, OUT=288.52' PP / ELEQ BdX z5 'Bs INTERSECTION OF POOLE DR. g< AVERSBORO RD. CO & ASSOCIATES B.O.M. 1984, PG 645 VACANT / EXISTING 4" WATER VALVE LOCATION TO BE VERIFIED PRIOR TO CONSTRUCTION RELOCATE AS NEEDED TO KEEP LINE ACTIVE TRANS- DO1 *A.- YARD INLET "RCP INV=291.31' DO1 SERVICE AVERSBORO ROAD OFFICE CENTER, LLC USE: OFFICE BUILDING 20' TOWN OF GARNER DRAINAGE & UTILITY EASEMENT ' 20' UTILITY EASEMENT -2 g) cp TOP: 305.90 TRANS- INV IN (NORTH): 301.40 INV IN (EAST): 300.65 INV IN (SOUTH): 297.73 INV OUT: 297.72 218,18' EPK EIP SURVEY NOTES: 1. ON SITE BOUNDARY, TOPOGRAPHY AND PLANIMETRIC INFORMATION IS TAKEN FROM A SURVEY BY B.L. SCOTT LAND SURVEYING DATED MARCH 7TH, 2016. OFFSITE TOPOGRAPHY AND PLANIMETRIC INFORMATION FROM OTHER SOURCES AND HAS NOT BEEN FIELD VERIFIED BY TIMMONS GROUP. 2. ALL DISTANCES SHOWN ON SURVEY ARE HORIZONTAL GROUND DISTANCES UNLESS OTHERWISE NOTED. 3. THIS SURVEY DOES NOT REPRESENT A TITLE SEARCH BY THIS FIRM. 4. BASIS OF BEARING SHOWN HEREON IS NC GRID NAD 83 (NSRS 2007). 5. VERTICAL DATUM SHOWN HEREON IS NAVD88. 6. OTHER SOURCES OF INFORMATION INCLUDE XXX. 7. NOT LOCATED IN FLOOD HAZARD AREA PER FEMA MAP #3720171000J (EFFECTIVE 05-02-2006). 8. RECORDED PROPERTY DATA: 8.1. BM 1984 PG 00503 8.2. DB 10219 PG 1519-1523 9. EXISTING IMPERVIOUS AREA = 0.00 ACRES 10. THE UTILITIES ON THESE PLANS ARE APPROXIMATE ONLY, AND ARE NOT ACCURATE FOR CONSTRUCTION PURPOSES. FOR FIELD MARKS CALL 811. DEMOLITION NOTES 1. ALL UTILITIES OR STRUCTURES NOT INDICATED FOR REMOVAL OR MODIFICATION ARE TO REMAIN AND BE PROTECTED FROM DAMAGE. 2. CONTRACTOR TO OBTAIN, REFERENCE, AND UTILIZE ALL AVAILABLE ENVIRONMENTAL REPORTS (PHASE 1 ESA, ASBESTOS, ETC.) FROM DEVELOPER. 3. ALL WASTE MATERIAL GENERATED FROM CLEARING AND DEMOLITION ACTIVITIES SHALL BE DISPOSED OF OFF -SITE IN ACCORDANCE WITH ALL APPLICABLE RULES AND REGULATIONS. 4. REMOVE/ DEMOLISH/ ABANDON AFTER EROSION CONTROL MEASURES ARE IN PLACE AN APPROVAL OF THE INSPECTOR. REFER TO EROSION CONTROL PLAN. 5. REMOVE TOPSOIL AND STOCKPILE APPROPRIATELY ON -SITE. ON -SITE TEMPORARY STOCKPILES SHALL BE LOCATED WITHIN CONSTRUCTION LIMITS. 6. DO NOT INTERRUPT EXISTING UTILITIES SERVICING FACILITIES OCCUPIED BY THE OWNER OR OTHERS EXCEPT WHEN PERMITTED UNDER THE FOLLOWING CONDITIONS AND THEN ONLY AFTER ARRANGING TO PROVIDE ACCEPTABLE TEMPORARY UTILITY SERVICES. (1) NOTIFY OWNER NOT LESS THAN ONE WEEK IN ADVANCE OF PROPOSED UTILITY INTERRUPTIONS. (2) DO NOT PROCEED WITH UTILITY INTERRUPTIONS WITHOUT RECEIVING OWNER WRITTEN PERMISSION. (3) COORDINATE ALL UTILITY RELOCATION WITH APPROPRIATE UTILITY PROVIDER. 7. ALL PAVEMENT OR CONCRETE TO BE REMOVED SHALL BE SAW CUT TO PROVIDE A STRAIGHT AND UNIFORM JOINT WITH NEW CONSTRUCTION. ANY EXISTING PAVEMENT, SIDEWALK, CURB & GUTTER, ETC. THAT MUST BE REMOVED TO ALLOW NEW CONSTRUCTION SHALL BE REMOVED TO ALLOW NEW CONSTRUCTION SHALL BE REMOVED AND REPAIRED PER THE SPECIFICATIONS AND DETAILS OR TO MATCH EXISTING CONDITIONS (WHETHER OR NOT SHOWN ON THE DRAWINGS TO BE REMOVED). UTILITY INSTALLATIONS MAY UTILIZE OPEN CUT OF PAVEMENTS UNLESS INDICATED OTHERWISE. TRENCH IN EXISTING ASPHALT SHALL BE PATCHED PER PAVEMENT REPAIR DETAIL. 8. PROTECT ALL ADJACENT PROPERTIES, THE GENERAL PUBLIC AND ALL OF THE OWNER'S FACILITIES. SHOULD DAMAGE OCCUR, NOTIFY ARCHITECT IMMEDIATELY. 9. SUBSURFACE FEATURES ARE SHOWN IN APPROXIMATE LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE UTILITY EXPLORATION TO DETERMINE UTILITY LOCATIONS AND DEPTHS. 10. THE CONTRACTOR SHALL USE NC ONE CALL (811) TO LOCATE ALL UNDERGROUND UTILITIES. 11. CONTRACTOR TO VERIFY LOCATIONS AND SIZES OF ALL EXISTING FEATURES PRIOR TO COMMENCEMENT OF CONSTRUCTION. REPAIR AND REPLACE ANY DAMAGES TO EXISTING UTILITIES RESULTING FROM CONSTRUCTION. 12. CONTRACTOR IS RESPONSIBLE FOR REMOVING OR ABANDONING ALL EXISTING UTILITIES AND STRUCTURES REQUIRED TO COMPLETE SITE CONSTRUCTION, EITHER ONSITE OR IN PUBLIC ROW, IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS. 13. WATER AND SEWER ABANDONMENT SHALL BE DONE IN ACCORDANCE WITH XXXXX STANDARDS INCLUDING DISCONNECT FROM THE MAIN AND REMOVAL OF SERVICES FROM THE RIGHT-OF-WAY. 14. ANY EXISTING UNIDENTIFIED SEPTIC SYSTEMS AND WELLS FOUND ON SITE SHALL BE REMOVED OR ABANDONED IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS AT NO CHARGE TO THE OWNER 15. VERIFY ALL ILLUSTRATED KNOWN UNDERGROUND ELEMENTS. EXERCISE REASONABLE EFFORTS TO PROTECT ANY UNKNOWN UNDERGROUND ELEMENTS. NOTIFY THE ARCHITECT IMMEDIATELY IF UNKNOWN ELEMENTS ARE DISCOVERED THAT WOULD NECESSITATE MODIFICATION TO THE PROPOSED DESIGN. 16. CONTRACTOR SHALL COORDINATE ALL CONNECTIONS, RELOCATION AND DEMOLITION WORK WITH THE APPROPRIATE COMPANY OR JURISDICTION HAVING AUTHORITY AND SHALL OBTAIN ANY PERMITS AS REQUIRED. 17. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE, AND OSHA REGULATIONS. 18. EXISTING MANHOLES, VALVE BOXES, VAULTS, CLEANOUTS, UTILITY POLES ETC. TO REMAIN WITHIN THE GRADING LIMITS SHALL BE ADJUSTED AS NEEDED TO FUNCTION PROPERLY WITH THE PROPOSED FINISHED GRADES (WHETHER OR NOT INDICATED TO BE MODIFIED). 19. GENERAL CONTRACTOR TO COORDINATE ALL PEDESTRIAN ACCESS PATHS, LOCATIONS, LIGHTING ETC. WITH THE DEVELOPER. 20. CONTRACTOR SHALL NOTIFY APPROPRIATE DEPARTMENTS PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT-OF-WAY. DEMOLITION KEYNOTES NUMBER DESCRIPTION DO1 EXISTING FEATURE TO REMAIN. DO2 REMOVE EXISTING FEATURE IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS. CONTRACTOR TO COORDINATE AS NEEDED WITH LOCAL MUNICIPALITY, INSPECTORS, AND/OR UTILITY COMPANIES. DO3 EXISTING SIDEWALK TO BE REMOVED DO4 EXISTING CURB AND GUTTER TO BE SAWCUT AND REMOVED DEVELOPER TO COORDINATE REMOVAL OF ON -SITE FENCES AS NEEDED LINE DATA NUMBER BEARING DIST. SCALE 1"=20' PRELIMINARY - NOT RELEASED FOR CONSTRUCTION ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF GARNER, CITY OF RALEIGH, NCDEQ AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS 05/741/202, E cri LU LU eL rie cp tip -to co o o LU ri YOUR VISION ACHIEVED THROUGH OURS. REVISION DESCRIPTION Lu Lu Lu Lu Lu Lu Lu Lu Lu Lu Lu Lu Lu REVISED PER TOWN OF GARNER COMMENTS Lu 00 DATE 06/17/2019 • • • • • • • • • DRAWN BY 332 DESIGNED BY 332 CHECKED BY P. BARBEAU SCALE 121 Z 1-1 Lu 0 Ln LLI EXISTING CONDITIONS AND DEMOLITION JOB NO. 37931 SHEET NO. ai 0 tts tts CC W -Fp OD CD 0 oc o tcs tts tts GRADING AND STORM DRAINAGE NOTES S:\332\37931-Leighson_Landing\DWG\Sheet\CD\37931-332-C3.0-GRAD.dwg I Plotted on 5/13/2021 2:31 PM I by Alex May / EX. 30" C&G EX, 0 W/L �� - / �"/mac / _� �� / i / / / /- W ( . , / / \' EX IN SAN TBM: TOP FH ELEV=292,83' STORM MANHOLE RIM=290,16'� INV, J�N�18"RC�Y\1186,30' ro ENV, I 3& RCP=283,31' 4 �Nk�❑UT 36"RCP=283,1711 W A VC SANITARY wE� �S co EWA�K V----- L-----0HP- EX. FES7 / / / / / / co co i // / 0 / j/ 1 lot i i // /I i 1 II 11 1/1i III Wy iii 40' UTILITY EASEMENT CLASS 'A' RIPRAP -...784/1/ li 1 i -;-________ _.% i CLEANOUT / 8" HDPE ROOF DRAIN AT MIN. 1% SLOPE JB101 TW BW FE100 NIT 01 FFE: 293.70 BW TW CLASS 'A' RIPRAP TW vv , , _____- , , ______ \''' ?001.- , 9_9) ocoo, sAN_____ __ _____ As NI- --9'._ ---- -- nil AoullINR „\ GNp I I GO1 <zliaar''w TW BW CLASS 'A' RIPRAP FFE: 295.50 FFE: 295.50 11111111i1I91101 tip IF FFE: 295.50 1\-r-A0111:1171:1\194p HP 111111104 IGND FFE: 295.50 FFE: 295.50 FFE: 295-:50 20' TOWN OF GARNER DRAINAGE & UTILITY EASEMENT (BM1984; PG503) 1,40 SIDIKt IN POWER/ POLE co EXISTING 4" WATER VALVE LOCATION TO BE VERIFIED PRIOR TO CONSTRUCTION RELOCATE AS NEEDED TO KEEP LINE ACTIVE EXISTING SSWR MH TO REMAIN EXISTING YARD INLET TO REMAIN ARD INLET P INV=291.31' 20' TOWN OF GARNER DRAINAGE & UTILITY EASEMENT c!) 20' UTILITY EASEMENT CD 1. CONTRACTOR SHALL CALL "NORTH CAROLINA ONE CALL" (811) AT LEAST 3-12 BUSINESS DAYS PRIOR TO DIGGING TO HAVE EXISTING UTILITIES LOCATED. REPORT ANY DISCREPANCIES TO THE ENGINEER. 2. CONTRACTOR TO COORDINATE ACTIVITIES WITH UTILITY COMPANIES INVOLVED IN ANY RELATED RELOCATION (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 3. EXISTING UTILITIES SHOWN ARE BASED ON FIELD SURVEYS AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 4. THE CATCH BASINS AND YARD INLETS SHALL BE CONSTRUCTED IN THE LOCATIONS SHOWN UNLESS OTHERWISE DIRECTED BY THE ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR REPORTING ANY DISCREPANCIES IN THE CATCH BASIN ELEVATIONS OR THE PROPOSED PIPE SLOPES TO THE ENGINEER. THE CONTRACTOR IS ALSO RESPONSIBLE TO REPORT ANY CONFLICTS BETWEEN ANY UTILITY, STORM DRAIN LINE, WATER LINE, SEWER LINE OR ANY OTHER PROPOSED OR EXISTING STRUCTURE TO THE ENGINEER. 5. A LAND DISTURBING PERMIT WILL BE REQUIRED PRIOR TO THE COMMENCEMENT OF ANY LAND -DISTURBING ACTIVITIES. 6. ALL EXISTING VAULTS, MANHOLES, STORM DRAIN STRUCTURES, VALVE BOXES, CLEANOUTS, ETC. SHALL BE ADJUSTED AS NEEDED TO MATCH FINISHED GRADE. 7. ALL BACKFILL, COMPACTION, SOILS TESTING, ETC. SHALL BE PERFORMED BY THE OWNER'S INDEPENDENT TESTING LABORATORY. 8. ALL SPOT ELEVATIONS INDICATED ARE AT TOP OF CURB UNLESS NOTED OTHERWISE. ALL ELEVATIONS ARE BASED ON VERTICAL DATUM NAVD88. 9. A PRE -CONSTRUCTION MEETING MUST BE SCHEDULED PRIOR TO ANY WORK, GRADING OR INSTALLATION OF EROSION CONTROL MEASURES. 10. ALL HANDICAP PARKING SPACES AND STRIPED ACCESSIBILITY AISLES ARE TO HAVE NO MORE THAN A 1:50 (2.0%) SLOPE IN ALL DIRECTIONS. ALL SIDEWALKS ARE TO HAVE NO MORE THAN A 1:20 (5.0%) SLOPE FOR THE LENGTH OF THE SIDEWALK AND NO MORE THAN A 1:50 (2.0%) SLOPE FOR THE WIDTH OF THE SIDEWALK. 11. CONTRACTOR TO IDENTIFY ALL NECESSARY SPILL CURB SECTION LOCATIONS AND INSTALL TO ENSURE POSITIVE DRAINAGE TO STORM STRUCTURES. 12. IF CONTRACTOR NOTICES ANY DISCREPANCIES IN ANY OF THESE SLOPE REQUIREMENTS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNER PRIOR TO POURING ANY CONCRETE SO THAT A SOLUTION CAN BE FOUND. 13. SPOT ELEVATIONS ARE GIVEN AT THE MAJORITY OF THE MAJOR BREAK POINTS BUT IT SHOULD NOT BE ASSUMED THAT ALL NECESSARY SPOT ELEVATIONS ARE SHOWN. DUE TO SPACE LIMITATIONS, THERE MAY BE OTHER CRITICAL SPOTS NOT LABELED THAT SHOULD BE TAKEN INTO CONSIDERATION. THE CONTRACTOR SHALL REVIEW THE GRADING PLAN IN DETAIL AND SHALL ENSURE THAT ALL CRITICAL GRADE POINTS ARE STAKED AND FOLLOWED TO PROVIDE POSITIVE DRAINAGE. 14. EXISTING VEGETATION WITHIN TREE PROTECTIVE AREAS SHALL REMAIN UNDISTURBED UNLESS NOTED OTHERWISE. ANY AND ALL LANDSCAPING AND EXISTING TREES AND SHRUBS TO REMAIN WHICH ARE DAMAGED DURING DEMOLITION OR CONSTRUCTION SHALL BE REPLACED BY THE CONTRACTOR USING A LICENSED LANDSCAPE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 15. THE GRADING CONTRACTOR SHALL COMPLY WITH ALL STATE CODES IN OBSERVING EROSION CONTROL MEASURES BOTH ON AND OFF -SITE. THE GRADING CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL DEVICES AFTER EACH RAINFALL EVENT OR AS DIRECTED BY THE EROSION CONTROL INSPECTOR OR THE ENGINEER. 16. THE GRADING CONTRACTOR SHALL BE RESPONSIBLE FOR OFF -SITE DISPOSAL OF ALL CLEARING AND GRADING WASTE MATERIALS GENERATED DURING CONSTRUCTION AND FOR OBTAINING ALL APPLICABLE PERMITS FOR OFF -SITE STOCKPILES AND/OR WASTE AREAS. 17. ALL CATCH BASINS MUST BE MARKED "DUMP NO WASTE DRAINS TO STREAM" OR 18. CONTRACTOR TO ENSURE ACCESS EASEMENTS AND ASSOCIATED STREETS ARE FULLY MAINTAINED FOR REASONABLE ACCESS BY MAINTENANCE PERSONNEL. 19. SITE IS NOT WITHIN A 100 YEAR FLOOD PLAIN PER FIRM MAP 3720171000J DATED MAY 2, 2006. 20. ALL STORM DRAIN PIPES SHALL BE PROTECTED WITH STONE FILTER PROTECTION AFTER STOPPAGE OF WORK EACH DAY 21. . ALL ROOF DRAINS SHALL BE DIRECTED TO THE STORM DRAIN SYSTEM. 22. ALL SLOPES TO BE VEGETATED WITH GRASS SHALL BE A MAXIMUM OF 3:1. 23. AT THE CONCLUSION OF THE PROJECT ALL SCMS INSTALLED ON -SITE SHALL BE CERTIFIED BY A DESIGN PROFESSIONAL AND THE TOWN OF GARNER ENGINEERING DEPARTMENT MUST RECEIVE ALL AS -BUILT DRAWINGS PRIOR TO RECEIVING THE CERTIFICATE OF OCCUPANCY. STORM STRUCTURE TABLE STR # TOP DESCRIPTION DI105 291.30 SLAB TOP YARD INLET EXYI 297.64 Existing Yard Inlet FE100 286.61 Flared End Section JB101 291.75 Junction Box JB102 291.65 Junction Box JB103 292.00 Junction Box JB104 293.63 Junction Box RS 288.34 Riser STORM PIPE TABLE PIPE # UPSTREAM INVERT DOWNSTREAM INVERT SLOPE LENGTH DIA MATERIAL 102-101 285.10 284.90 0.40% 50.22 LF 18" RCP 103-102 285.30 285.10 0.36% 55.14 LF 18" RCP 104-103 286.10 285.30 0.70% 114.03 LF 18" RCP 105-103 286.00 285.30 0.76% 91.70 LF 18" RCP EXYI-102 291.31 287.00 4.60% 93.63 LF 18" RCP RS-100 284.89 284.70 0.80% 23.63 LF 18" RCP RS-101 285.82 285.20 3.34% 18.54 LF 18" RCP STORM DRAINAGE NOTE LEGEND NOTE DESCRIPTION CB CATCH BASIN DI DROP INLET NI NYLOPLAST INLET YI YARD INLET JB JUNCTION BOX FE FLARED END SECTION XX" RCP CYLINDRICAL REINFORCED CONCRETE PIPE TEMPORARY TREE PROTECTION FENCE TPF -> -> -> -> -> - PERMANENT DITCH GRADING KEYNOTES NUMBER DESCRIPTION GO1 MAX 2% SLOPE IN ANY DIRECTION (TYP.) GO2 HVAC PAD TO BE AT 295.0' MIN. 0 SCALE 1"=20' PRELIMINARY - NOT RELEASED FOR CONSTRUCTION ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF GARNER, CITY OF RALEIGH, NCDEQ AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS \\\\:Issi///0/4///ii/4/ THIS DRAWING PREPARED AT THE CORPORATE OFFICE rsi rsi .12 - co rn u. co rsi co YOUR VISION ACHIEVED THROUGH OURS. REVISION DESCRIPTION a. CO a. a. 0 REVISED PER TOWN OF GARNER COMMENTS Lu 00 Ln DATE 06/17/2019 • • • • • • DRAWN BY 332 DESIGNED BY 332 CHECKED BY P. BARBEAU SCALE 0 GARNER DISTRICT - WAKE COUNTY - NORTH CAROLINA JOB NO. .379.31 SHEET NO. ai tts 17) 2 CD tts 45 fa o tcs tv -roc a)