Loading...
HomeMy WebLinkAboutWQ0030538_Regional Office Historical File Pre 2018 (2)NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H, Sullins Dee Freeman Director Secretary Governor Mr. David Kraus, City Manager City of Mount Holly 131 South Main Street PO Pox 406 Mount Holly, NC 28120 December 2, 2009 Subject: Permit. No. WQ0030538 Modification Water's Edge Wastewater Collection System Extension Gaston County, North Carolina Dear Mr. Kraus, In accordance with your complete application received on November 19, 2009, we are forwarding herewith Permit No. WQ0030538 dated December 2, 2009, to the City of Mount Holly for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Perrnit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0493 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting, of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application, It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Region atl C•t*ice ocabon: 610 East Center Ave..„ Suite 301 Mooresrflte, NC 28115 E one° (;704) 663-1699 t Fax (704) 6636040 1 Customer. Service., 1-877-623 4 Onn Ni r1hC holing l Mr, Garbark, Face 2 September 1, 20C9 In accordance with the provisions of Article 21 of Chapter 143, General Statutes ofNorm Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 6,821 linear feet of 8-inch gravity sewer and the discharge of 85,500 gallons per day of domestic wastewater into the existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be reated in the Mount Holly VWTP (NPDES No.NC0021156) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system is the complete responsibility of Mount Holly. Mount Holly must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and their collection system permit WQCS00059. if any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall be final and binding If you need additional information concerning this matter, please contactDee Browder at (704) 663-1699. Sincerely, for o een H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Surface Water Protection Central Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21._ .0200 or the surface water standards in 15A NCAC 2B ,0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Purnp stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year, g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215,1C 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate, The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification farm attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable, 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities; Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215,6A through §143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily; including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 28 .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 28.0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report, Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 3 3-03 or (919) 733-33 0 Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS -SS (or the most current Division approved form), within five days following first knowledge of the occurrence, This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form S-SS (or the most current Division approved forrrr) can also be completed to show that the SSO was beyond control. Permit issued this the 2nd day of December, 2009, NORTH A Ll ENVIRONMENTAL MANAGEMENT COM1 ISS1 N Coieen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management orr miss or PermttNu a rWQ0030538 Modification Fast Track. Engineering Certification Permit No, WQ0030538 Modification December 2, 2.009 Owner/WQCS/WNTP PE David Kraus,City Manager Byran Metzler Mount Hotly Turnbull Metzler Design 131 South Main Street 1001 Morehead Square Dr, Suite 530 Mount Holly,, NC 28120 Charlotte, NC 28203 Complete and subrnit this form to the permit issuing regional office with the following One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater c ollection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of thus project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resultin in noncom Hance with thesis ermlt, re uiations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial [j Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (El ,periodically, E weekly, 0 full time) the construction of W.ater's Edge, a Gasen County project for the Permitted, hereby state that, to the best of my abilities., due care and diligence was used in the observation of the construction such that the construction was observed to be built. within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 a.s applicable,, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2.000 as applicable, and other supporting materials North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit andshall subject the Permittee to appropriate enforcement actions, z 0 0 Mailing Address lf. NC State USE THE TAB KEY TO MOVE FROM HELD TO FIELD! Owner/Permittee: la: The City of Mount Holly_ Full Legal Name (company, municipality, HOA, utility, etc. lb David Kraus, C_tyi Manager Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials!) The legal entity who will own this system is: El Individual Z Federal Municipality E3 State/County I] Private Partnership Z Corporation El Other (specify): Application Number: (to be completed by DWQ) id 131 South Main Street, PO Box 406 0 1 bi, 704-827-393 1 i, 704-822-2933 Telephone Facsimile 0 2 Project (Facility) Information: 2a. Water's Edge SanitarySewer a. Brief Project Name (permit will refer to this name) CL < 3 Contact Person: 4 3a, Erni!y_ Perry, El — Turnbull Metzler Design Name and Affiliation of Someone Who Can Answer Ques 3b 704-529-6500 z 0 0 z u. Phone Number le, t Holly City 1g, 28120 Zip Code lj david.kraus@mtholly.us E-mad 2b. Gaston__ County Where Project is Located ons About this Application 3c. eperry@turnbullmetzlercom 1. Project is El New Z Modification (of an existing permit) If IVIodification, Permit No,: WQ0030538 2. Owner is Public (skip to !teal B(3)) 2a. If private, applicant will be: El] Retaining Ownership (i.e, store, church, single office, etc.) or Leasing units (lots, townhomes etc - skip to Item 8(3)) LI Selling units (lots, (ownhomes, etc. - go to Item 8(2b)) 3, City of Mount Holly Ei Private (go to Item 2(a)) 2b if sold, facilities owned by a (must choose p_ne) Public Utility (Instruction C) 11 Homeowner Assoc./Developer (Instruction D) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Mount Holly_Wastewater Treatment Plant Name of WVVTF 5a, City of Mounl_Holly ___ 5b. 8 1 Gravity 15c. Owner of Downstream Sewer 1Receiving Sewer Sizelp Force Main i Permit # of Downstream Sewer (Instruction E) The origin of this wastewater is (check all that apply): Residential Subdivision [1] Apartments/Condominiums LI Mobile Home Park LIJ School [I] Restaurant El Office 4b, NC0021156 MUTT Permit No El Retail (Stores, shopping centers) institution LI Hospital LI Church El Nursing Home LI Other (specify): 7, Volume of wastewater to be allocated or permitted for this particular project: 2 *Do not include future flows or previously permitted allocations 8: If the permitted flow is zero, indicate why: Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line LJ Flow has already been allocated in Permit No, El Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) 100 % Domestic/Commercial °./0 Industrial (attach description) (RO: contact your Regional Office Pretreatment staff) % Other (specify): gallons per day FIA12107 9 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7) Values other than that in 15A NCAC 2T ,0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T ,0114 (f). 8 Additional Townhome Residences x 300 GPD/residence = 2,400 GPD (Approximately 2 5 bedrooms per residence) 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8" Length (feet) 6,821 LF 95 LF New Gravity or Additional Force Main Gravity FM (Individual Unit Grinder Pumps) 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow Power Reliability Option Operational Point (MGD) 1 - permanent generator w/ATS; Force Main Size Force Main Length GPM @TDH 2 - portable generator w/MTS Pump Station Location ID Design Flow (MGD) (self chosen - as shown on plans/map for reference) Power Reliability Option Operational Point GPM @TDH 1 2permanent generator MATS; Force Main Size Force Main Length - portable generator w/MTS Pump Station Location Design Flow (MGD) Operational Point GPM @TDH (self chosen - Power Reliability Option - permanent generator w/ATS; 2 - portable generator w/MTS as shown on plans/map for reference) Force Main Size Force Main Length 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? r,1 Yes El No If Yes, permit number of 2nd treatment facility (RO - if "yes" to 8,12 please contact the Central Office PERCS Unit) 13, Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? E] Yes El No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 2 '0 7 14. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 4D1Certification? 0 Yes El No N/A Sedimentation and Erosion Control Plan? Stormwater? Yes 0 No 0 N/A Yes 0 No 0 N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T 0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: 0 and provide details la Owner/Permittee's Certification. (Signature of Signing Official and Project Name) I„ _Eric Davis attest that this application for Waters Edge Sanitary SewerSj?stem has been reviewed by me and is accurate and complete to the best of my knowledge„ I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor; which may include a fine not to exceed $70,000 as well as civil penalties up to $25;000 per violation. Signing Offlcia! Sign tur Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY co TO OTHER UTILITIES, DESIGN CALCULATIONS ETC. REFER TO 15A NCAC 02T ,0305 0 I— 2, Professional Engineer's Certification: (Signature of Design Engineer and Project Name) (.3 I, _Bryan C. Metzler, PE attest that this application for WaterSEd_ge Sant has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge, I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Cnteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Purnp Stations and Fame Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC Genera/ Statutes /43-215.6A and 1,43-215.6B, any person who knowingly makes any fa/se statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Bryan C. Metzler Professional Engineer Name 2b. Turnbull Metzler Design Engineering Firm 2c. 1001 Morehead Square Drive, Suite 530 Mailing Address 2d Charlotte City 2e, NC 2f: 28203 State Zip 2g 704-529-6500 2h 704-522-0882 2i, bmetzlerturnbuUmetzler,co Telephone Facsimile E-mail NC PE Seal, Signature & Date ET'A I 2/07 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow TracldngfAcceptance for Sew r Extension Permit Applications (FTSE—45/07) Project Applicant Name: ri Project Name for which flow is being requested: !N Amount of flow requested for this project: 0, 60 I. Complete this section only if you are the owner of the wastewater treatment plant. WWTP Facility Name: WWTP Facility Permit #: 5l, WWTP facility's permitted flow WWTP facility's actual flow Obligated flow not yet tributary to the WWTP Total actual and obligated flows to the facility Total flow for this specific request Remaining capacity = [Permitted flow —(total actual + obligated + requested)] II. Complete this section for each pump station you are responsible for along the route of thi proposed wastewater flow, List pump stations located between the project connection point and the WWTP Pump Station Name Capacity Certification Statement: .--► e s /47-i Clt , certify that the addition of the volume of wastewater to be permitted in this project has een evaluated along the route to the receiving wastewater treatment facility and that the flow from this project will not cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant. This certification applies to those items listed above in Sections I and II for which I am the responsible a Signature of this form indicates acceptance of this wastewater flow. Signing •'eial Signature r Date Permit Number' Q0030 ntrdl Files: ,APS S Permit Tracking Slip 2102/09 Program Category Non -discharge Status Project Type Active Mai o modification Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, Pressure Sewer 1,10 Individual Extensions PrimaryReviewer marcia.allocco Coastal SW Pule Pe Flow 83 Fe Facility Name ater°s Edge nation Address Owne Permit Contact Affiliation Major/ inor Region Minor Mooresville, County Gaston Facility Cc rtlt» t Affiliation Owner Name City of Mount Holly /Events Owner Type Government- Municipal Owner Affiliation Eric Davis City Manager PO Box 406 Mount Holly NC 23120 Scheduled °rig Issue App Received Draft I Issuance Public Notice Issue Effective Expiration 0 /02/06 10r" f 12/02/09 12/02/09 Regulated Activities Subdivision Wastewater il9eotion Out P t t diReceived Events Additional inforration received Additional information requested Additional iraforrrratlon received Additional snforrrratlon received Additional info on requested Additional inforiration requested Additional information received 10/23/09 11 i1 /09 11 /19/09 taterbody Name index Number Current Class Subbasin 01f25/2010 14:49 70482732 CITY OF MT HOLLY FADE 0B N December 2, 2009 Owner/WQCSAMATTP David Kraus, City Manager Mount. Holly 131 South Main Street Mount Holly, NC 2S120 .a By Turnbull Meier Design 1 001 Morehead Square Dr, Suite 530 Charlotte, ND 28203 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (pion & profile views of sewer lines) of the wastewater collection system extensions Supporting design calculations (selected pumps, system curve, operating point, avalfable storage If portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to tfte project ehestlld be clearly identified on the record ,drawings or in wrttts m d` i are r i f [ usages resuitirty irs now r rgoliarrce with thle_or" urn des This project shell not be considered corrrptete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, It le highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. EN y form. Permit igrus or Partied D Final as a duly registered Professi+arret Engineer in th State of t Iorth Carolina, having been authorized to observe ( pe radically, 0 weekly, 0 full 'time) the construction of Water's Edge, a Gaston County project for the Permitted, hereby state that, to the best of my abilities, due care and dltigence was used in the observation cf the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1995 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materiels. I ii I , ? 7 LE 8`f 904trAitYSti.verb i 0..ex,,,,,,, V ; 100 05., 1ii3-l8.7 North Caroline Professional Engineer's steal, signature, and date GAR The perP°nittre i responsible for tract wastewater flow made tributary to the Engineer's Certification shell be consi enfarcernent actions SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NG 28115 partial certifinanions up until a final certification is re &veed, Arty water collection system extension prior to completion of this d a violation of the permit and shall subject the Perrrrlttes to appropriate Danny Jackson, City Manager Fast Track Engineering Certification -Yr 400 E. Central Ave, Permit No. WQ0030538 Modification Mount Holly, NC 28120 December 2, 2009 OwnerNVQCS/WWTP Mount Holly, NC 28120 Evan Mooney, PE Merrick & Company 1001 Morehead Square Dr, Suite 530 Charlotte, NC 28203 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be dearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria, This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Ej Partia EJ Final Partial Certification includes: 147.40 LF of 8" ' DIP from Ex. MH26D to MH 26E. This line serves the 6 units of Building 29, I, Evan Mooney, PE , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (Ej periodically, Ej weekly, C full time) the construction of Water's Edge, a Gaston County project for the Permitted, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, 000 MERRICK o No 000 & COMPANY TRANSMITTAL To: NCOEQ Mooresville Regional Office c/a Barry Love 610 East Center Avenue, Suite 301 Mooresville, NC 28115 (704) 235-2143 Quantity Description 1 As -built plan sheet 1 Partial certification document Remarks Date: 12/6/2017 Document: Wastewater Partial Certification Ref,: Waters Edge Job #: 65119414-00 Sent Via: Courier Please find attached wastewater partial certification for Waters Edge project. If you have any questions, please feel free to call me 704-612-0702 or send an email, justin.mcdonald@merrick.com. I appreciate your time!! Respectfully submitted, Merrick & Company Received by By: f ON A Ju cDonald, El — CivEngineer I Date: Time: Merrick & Company — Charlotte 1001 Morehead Square Drive Charlotte, NC ,28203 704-529-6500 RECEiVEL N Fast Track Engineering Certification Permit No. WQ0030538 Modification December 2, 2009 Owner/VVQCS/WWTP City Manager Mount Holly 131 South Main Street Mount Holly, NC 28120 Danny Jackson Q IR PE Robert Tripp IV Merrick & Company 1001 Morehead Square Dr. ,Suite 530 Charlotte, NC 28203 Complete and submit this form to the permit issuing regional office with the following; One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial 0 Final 1, Robert E. Tripp IV as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ( periodically, 0 weekly, 0 full time) the construction of Waters Edge, a Gaston County project for the Permitted, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEAL, 23505 SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Certification to include: Manholes 13 and 13a 409.39 LF of 8" PVC