Loading...
HomeMy WebLinkAbout20210513 Ver 1_USACE More Info Requested_20210602Strickland, Bev From: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Sent: Wednesday, June 2, 2021 10:24 AM To: Homewood, Sue; Sydni Law Subject: [External] RE: Wexford SD - Request for Additional Information Follow Up Flag: Follow up Flag Status: Flagged CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Good Morning, Sydni: Please copy the USACE on your response to NCDWR. Also, please address the following: 1) How would the stream in Impact Area 1 be protected during construction? Similar projects often utilize a stream pump -around or similar measure to protect downstream areas from sedimentation during construction. 2) Impact Area 2 — similar concern. The proposed culvert would be buried approximately 1 foot below the existing grade within a wetland and at a 4.77 percent slope. Riprap proposed at the outlet of this culvert is presumably proposed to abate anticipated scour. We are concerned about preserving soil hydrology within the upslope wetland. Please address these concerns, and be aware that offsetting indirect impacts may be required for all upslope wetland areas. Also please note the north arrow may be incorrect on the impact detail. 3) Lots north of Impact Area 2 (refer to Overall Impact Map 2 (CWI-1.2) appear to show irregular fill slopes abutting the wetland edge, and bold lines that may indicate retaining wall (?) impacts within wetlands. Please provide additional detail to document no impact would result in these areas, including any permanent or temporary measures proposed to inform construction activities onsite. Thanks — please let me know if there are questions. Christopher D. Hopper Regulatory Specialist U.S. Army Corps of Engineers Regulatory Division 3331 Heritage Trade Drive, Suite 105 Wake Forest, NC 27587 (919) 554-4884, Ext. 35 We would appreciate your feedback on how we are performing our duties. Our automated Customer Service Survey can be accessed by copying and pasting the following link into your web browser: https://regulatory.ops.usace.army.mil/customer-service-survey/. Thank you for taking the time to visit this site and complete the survey. From: Homewood, Sue <sue.homewood@ncdenr.gov> Sent: Tuesday, June 1, 2021 10:07 PM To: Sydni Law <Sydni.Law@timmons.com> Cc: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Subject: [Non-DoD Source] Wexford SD 1 Hello Sydni, I have reviewed the PCN for Wexford (Manning Ave) and have one concern. We have revised our standard "culvert burial" requirement for pipes on steep slopes and to prevent the risk of causing headcuts in the channel we request that if the culvert slope cannot reasonably be reduced then the culvert be installed "at grade". Please see Condition 11 in the GC4256 as an example. Please revise the plans accordingly and submit new plan sheets (only pages with changes please). I will consider the application on hold until receipt of the updated plan sheets. Please let me know if you have any questions or comments, Thanks, Sue Homewood Division of Water Resources, Winston Salem Regional Office Department of Environmental Quality 336 776 9693 office 336 813 1863 mobile Sue.Homewood@ncdenr.gov 450 W. Hanes Mill Rd, Suite 300 Winston Salem NC 27105 2